941 resultados para Anterior Chamber


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To describe distributions of ocular biometry and their associations with refraction in 7- and 14-year-old children in urban areas of Anyang, central China. Methods: A total of 2271 grade 1 students aged 7.1 ± 0.4 years and 1786 grade 8 students aged 13.7 ± 0.5 years were measured with ocular biometry and cycloplegic refraction. A parental myopia questionnaire was administered to parents. Results: Mean axial length, anterior chamber depth, lens thickness, central corneal thickness, corneal diameter, corneal radius of curvature, axial length/corneal radius of curvature ratio, and spherical equivalent refraction were 22.72 ± 0.76 mm, 2.89 ± 0.24 mm, 3.61 ± 0.19 mm, 540.5 ± 31 μm, 12.06 ± 0.44 mm, 7.80 ± 0.25 mm, 2.91 ± 0.08, and +0.95 ± 1.05 diopters (D), respectively, in 7-year-old children. They were 24.39 ± 1.13 mm, 3.42 ± 0.41 mm, 3.18 ± 0.24 mm, 548.9 ± 33 μm, 12.03 ± 0.43 mm, 7.80 ± 0.26 mm, 3.13 ± 0.14, and −2.06 ± 2.20 D, respectively, in 14-year-old children. Compared with 7-year-old children, the older group had significantly more myopia (−3.0 D), longer axial length (1.7 mm), deeper anterior chamber depth (0.3 mm), thinner lens thickness (−0.2 mm), thicker central corneal thickness (10 μm), and greater axial length/corneal radius of curvature ratio (0.22) (all p < 0.001), as well as smaller corneal diameter (−0.03 mm, p = 0.02) and similar corneal radius of curvature. Sex differences were similar in both age groups, with boys having longer axial length (0.5 mm), deeper anterior chamber depth (0.1 mm), shorter lens thickness (0.03 mm), greater central corneal thickness (5 μm), greater corneal diameter (0.15 mm), and greater corneal radius of curvature (0.14 mm) than girls (all p < 0.01). The most important variables related to spherical equivalent refraction were vitreous length, corneal radius of curvature, and lens thickness. Conclusions: The 14-year-old group had larger parameter dimensions than the 7-year-old group except for corneal radius of curvature (unchanged) and lens thickness and corneal diameter (both smaller). Boys had large parameter dimensions than girls except for lens thickness (smaller). Axial length, corneal radius of curvature, and lens thickness were the most important determinants of refraction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose.: To develop three-surface paraxial schematic eyes with different ages and sexes based on data for 7- and 14-year-old Chinese children from the Anyang Childhood Eye Study. Methods.: Six sets of paraxial schematic eyes, including 7-year-old eyes, 7-year-old male eyes, 7-year-old female eyes, 14-year-old eyes, 14-year-old male eyes, and 14-year-old female eyes, were developed. Both refraction-dependent and emmetropic eye models were developed, with the former using linear dependence of ocular parameters on refraction. Results.: A total of 2059 grade 1 children (boys 58%) and 1536 grade 8 children (boys 49%) were included, with mean age of 7.1 ± 0.4 and 13.7 ± 0.5 years, respectively. Changes in these schematic eyes with aging are increased anterior chamber depth, decreased lens thickness, increased vitreous chamber depth, increased axial length, and decreased lens equivalent power. Male schematic eyes have deeper anterior chamber depth, longer vitreous chamber depth, longer axial length, and lower lens equivalent power than female schematic eyes. Changes in the schematic eyes with positive increase in refraction are decreased anterior chamber depth, increased lens thickness, decreased vitreous chamber depth, decreased axial length, increased corneal radius of curvature, and increased lens power. In general, the emmetropic schematic eyes have biometric parameters similar to those arising from regression fits for the refraction-dependent schematic eyes. Conclusions.: The paraxial schematic eyes of Chinese children may be useful for myopia research and for facilitating comparison with other children with the same or different racial backgrounds and living in different places.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The New Zealand White rabbit has been widely used as a model of limbal stem cell deficiency (LSCD). Current techniques for experimental induction of LSCD utilize caustic chemicals, or organic solvents applied in conjunction with a surgical limbectomy. While generally successful in depleting epithelial progenitors, the depth and severity of injury is difficult to control using chemical-based methods. Moreover, the anterior chamber can be easily perforated while surgically excising the corneal limbus. In the interest of creating a safer and more defined LSCD model, we have therefore evaluated a mechanical debridement technique based upon use of the AlgerBrush II rotating burr. An initial comparison of debridement techniques was conducted in situ using 24 eyes in freshly acquired New Zealand White rabbit cadavers. Techniques for comparison (4 eyes each) included: (1) non-wounded control, (2) surgical limbectomy followed by treatment with 100% (v/v) n-heptanol to remove the corneal epithelium (1-2 minutes), (3) treatment of both limbus and cornea with n-heptanol alone, (4) treatment of both limbus and cornea with 20% (v/v) ethanol (2-3 minutes), (5) a 2.5-mm rounded burr applied to both the limbus and cornea, and (6) a 1-mm pointed burr applied to the limbus, followed by the 2.5-mm rounded burr applied to the cornea. All corneas were excised and processed for histology immediately following debridement. A panel of four assessors subsequently scored the degree of epithelial debridement within the cornea and limbus using masked slides. The 2.5-mm burr most consistently removed the corneal and limbal epithelia. Islands of limbal epithelial cells were occasionally retained following surgical limbectomy/heptanol treatment, or use of the 1-mm burr. Limbal epithelial cells were consistently retained following treatment with either ethanol or n-heptanol alone, with ethanol being the least effective treatment overall. The 2.5-mm burr method was subsequently evaluated in the right eye of 3 live rabbits by weekly clinical assessments (photography and slit lamp examination) for up to 5 weeks, followed by histological analyses (hematoxylin & eosin stain, periodic acid-Schiff stain and immunohistochemistry for keratin 3 and 13). All 3 eyes that had been completely debrided using the 2.5-mm burr displayed symptoms of ocular surface failure as defined by retention of a prominent epithelial defect (~40% of corneal surface at 5 weeks), corneal neovascularization (2 to 3 quadrants), reduced corneal transparency and conjunctivalization of the corneal surface (demonstrated by the presence of goblet cells and/or staining for keratin 13). In conclusion, our findings indicate that the AlgerBrush II rotating burr is an effective method for the establishment of ocular surface failure in New Zealand White rabbits. In particular, we recommend use of the 2.5-mm rotating burr for improved efficiency of epithelial debridement and safety compared to surgical limbectomy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As the worldwide prevalence of diabetes mellitus continues to increase, diabetic retinopathy remains the leading cause of visual impairment and blindness in many developed countries. Between 32 to 40 percent of about 246 million people with diabetes develop diabetic retinopathy. Approximately 4.1 million American adults 40 years and older are affected by diabetic retinopathy. This glucose-induced microvascular disease progressively damages the tiny blood vessels that nourish the retina, the light-sensitive tissue at the back of the eye, leading to retinal ischemia (i.e., inadequate blood flow), retinal hypoxia (i.e., oxygen deprivation), and retinal nerve cell degeneration or death. It is a most serious sight-threatening complication of diabetes, resulting in significant irreversible vision loss, and even total blindness.

Unfortunately, although current treatments of diabetic retinopathy (i.e., laser therapy, vitrectomy surgery and anti-VEGF therapy) can reduce vision loss, they only slow down but cannot stop the degradation of the retina. Patients require repeated treatment to protect their sight. The current treatments also have significant drawbacks. Laser therapy is focused on preserving the macula, the area of the retina that is responsible for sharp, clear, central vision, by sacrificing the peripheral retina since there is only limited oxygen supply. Therefore, laser therapy results in a constricted peripheral visual field, reduced color vision, delayed dark adaptation, and weakened night vision. Vitrectomy surgery increases the risk of neovascular glaucoma, another devastating ocular disease, characterized by the proliferation of fibrovascular tissue in the anterior chamber angle. Anti-VEGF agents have potential adverse effects, and currently there is insufficient evidence to recommend their routine use.

In this work, for the first time, a paradigm shift in the treatment of diabetic retinopathy is proposed: providing localized, supplemental oxygen to the ischemic tissue via an implantable MEMS device. The retinal architecture (e.g., thickness, cell densities, layered structure, etc.) of the rabbit eye exposed to ischemic hypoxic injuries was well preserved after targeted oxygen delivery to the hypoxic tissue, showing that the use of an external source of oxygen could improve the retinal oxygenation and prevent the progression of the ischemic cascade.

The proposed MEMS device transports oxygen from an oxygen-rich space to the oxygen-deficient vitreous, the gel-like fluid that fills the inside of the eye, and then to the ischemic retina. This oxygen transport process is purely passive and completely driven by the gradient of oxygen partial pressure (pO2). Two types of devices were designed. For the first type, the oxygen-rich space is underneath the conjunctiva, a membrane covering the sclera (white part of the eye), beneath the eyelids and highly permeable to oxygen in the atmosphere when the eye is open. Therefore, sub-conjunctival pO2 is very high during the daytime. For the second type, the oxygen-rich space is inside the device since pure oxygen is needle-injected into the device on a regular basis.

To prevent too fast or too slow permeation of oxygen through the device that is made of parylene and silicone (two widely used biocompatible polymers in medical devices), the material properties of the hybrid parylene/silicone were investigated, including mechanical behaviors, permeation rates, and adhesive forces. Then the thicknesses of parylene and silicone became important design parameters that were fine-tuned to reach the optimal oxygen permeation rate.

The passive MEMS oxygen transporter devices were designed, built, and tested in both bench-top artificial eye models and in-vitro porcine cadaver eyes. The 3D unsteady saccade-induced laminar flow of water inside the eye model was modeled by computational fluid dynamics to study the convective transport of oxygen inside the eye induced by saccade (rapid eye movement). The saccade-enhanced transport effect was also demonstrated experimentally. Acute in-vivo animal experiments were performed in rabbits and dogs to verify the surgical procedure and the device functionality. Various hypotheses were confirmed both experimentally and computationally, suggesting that both the two types of devices are very promising to cure diabetic retinopathy. The chronic implantation of devices in ischemic dog eyes is still underway.

The proposed MEMS oxygen transporter devices can be also applied to treat other ocular and systemic diseases accompanied by retinal ischemia, such as central retinal artery occlusion, carotid artery disease, and some form of glaucoma.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aqueous humor is actively produced in the ciliary epithelium of the anterior chamber and has important functions for the eye. Under normal physiological conditions, the inflow and outflow of the aqueous humor are tightly regulated, but in the pathologic state this balance is lost. Aqueous outflow involves structures of the anterior chamber and experiences most resistance at the level of the trabecular meshwork (TM) that acts as a filter. The modulation of the TM structure regulates the filter and its mechanism remains poorly understood. Proteomic analyses have identified cochlin, a protein of poorly understood function, in the glaucomatous TM but not in healthy control TM from human cadaver eyes. The presence of cochlin has subsequently been confirmed by Western and immunohistochemical analyses. Functionally, cochlin undergoes multimerization induced by shear stress and other changes in the microenvironment. Cochlin along with mucopolysaccharide deposits have been found in the TM of glaucoma patients and in the inner ear of subjects affected by the hearing disorder DNFA9, a late onset, progressive disease that also involves alterations in fluid shear regimes. In vitro, cochlin induces aggregation of primary TM cells suggesting a role in cell adhesion, possibly in mechanosensation, and in modulation of the TM filter.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Punctate inner choroidopathy (PIC) is a relatively uncommon inflammatory multifocal chorioretinopathy that affects predominantly young myopic women. It is characterized by the presence of multiple, small, well-defined, yellow-white fundus lesions frequently limited to the posterior pole in the absence of flare and inflammatory cells in the anterior chamber or vitreous cavity. Most patients with PIC do not require treatment, as the disease does not often threaten vision; however, when subfoveal choroidal neovascular membrane (CNV) ensues, patients usually lose sight rapidly, requiring immediate care. Treatment modalities that have been used to manage patients with PIC and subfoveal CNV include systemic and local steroids, other immunosuppressant agents, laser photocoagulation, photodynamic therapy, submacular surgery and, most recently, anti-vascular endothelial growth factor therapy. To date, however, there is no clear consensus on the effective therapy. Further research into this area, as well as on the cause and possible predisposing factors for PIC, is warranted. © 2011 Elsevier Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To describe a new surgical approach in the management of pseudophakic malignant glaucoma. Design: Noncomparative case series. Participants: Five consecutive patients with pseudophakic malignant glaucoma. Methods: All patients underwent zonulo-hyaloido-vitrectomy. The procedure involves the performance of zonulectomy, hyaloidectomy, and anterior vitrectomy (zonulo-hyaloido-vitrectomy) through a peripheral iridectomy or iridotomy via the anterior chamber. Main Outcome Measures: Medications, visual acuity, intraocular pressure, and anterior and posterior segment findings were recorded before and after surgery. Results: Resolution of the malignant glaucoma was achieved in all cases. No recurrences were observed after a median follow-up of 5.5 months (range, 1-9 months). In one patient with extensive anterior synechiae, bleb failure occurred after the resolution of the malignant glaucoma. This patient was treated successfully with a guarded filtration procedure supplemented with 5-fluorouracil. No other complications were observed. Conclusions: Zonulo-hyaloido-vitrectomy via the anterior segment appears to be an alternative option in the treatment of patients with pseudophakic malignant glaucoma. © 2001 by the American Academy of Ophthalmology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE. To describe a new model of posterior capsule opacification (PCO) in rodents METHODS. An extracapsular lens extraction (ECLE), by continuous curvilinear capsulorrhexis and hydrodissection, was performed in 42 consecutive Brown Norway rats. Animals were killed at 0, 6, and 24 hours and 3, 7, and 14 days after surgery. Eyes were enucleated and processed for light microscopy and immunohistochemistry. RESULTS. In 34 (81%) of the animals the operated eye appeared well healed before death, with a clear cornea and a well-formed anterior chamber. In eight (19%) there was no view of anterior segment structures because of hyphema, fibrin, or corneal opacification. PCO was clinically evident 3 days after ECLE and was present in all animals at 2 weeks. Immediately after ECLE, lens epithelial cells (LECs) were present in the inner surface of the anterior capsule and lens bow. Twenty-four hours after surgery, LECs started to migrate toward the center of the posterior capsule. At 3 days, multilayered LECs, some spindle shaped, were present throughout the lens capsule. Capsular wrinkling was apparent. Lens fibers and Soemmering's ring were observed in all animals 14 days after surgery, indicating some degree of cellular differentiation. Activated macrophages were present in greater numbers at 3 and 14 days after surgery (P <0.05), when proliferation and migration of LECs appeared to be greatest, and lens fiber differentiation was evident, respectively. CONCLUSIONS. In rodents PCO occurs after ECLE and is associated with low-grade inflammation, mostly of mononuclear macrophages. Although no intraocular lens implantation was performed, this model appears to be valuable for studying the sequence of events that leads to PCO after cataract surgery and the extracellular matrix cues that promote lens fiber differentiation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To describe the clinical characteristics, natural course, and complications of a large group of patients with primary iris pigment epithelium (IPE) cysts. Design: Observational case series. Participants: Two hundred thirty-four patients with primary IPE cysts participated. Results: Primary IPE cysts were classified as central in 6 patients (3%), midzonal in 50 patients (21%), peripheral in 170 patients (73%), and dislodged in 8 patients (3%). Central (pupillary) IPE cysts were found only in males, peripheral IPE cysts were found most often in females (69%), and no gender predilection was detected for midzonal and dislodged IPE cysts. Central and peripheral IPE cysts occurred in young patients (mean age, 20 and 33 years, respectively), whereas midzonal and dislodged IPE cysts were seen in slightly older patients (mean age, 52 and 45 years, respectively). Central IPE cysts were visible when the pupil was not dilated and appeared most often as a round or collapsed brown lesion arising from the pupillary margin, most commonly superonasally. Midzonal IPE cysts were brown and fusiform, best visualized after pupillary dilation. Peripheral IPE cysts produced a characteristic bulging in the iris stroma near the iris root, but they were directly visible in only 78% of cases. After wide dilation and patient and slit-lamp positioning, they appeared as a round clear lesion behind the iris, most often in the inferotemporal quadrant. Finally, dislodged IPE cysts appeared as a brown oval lesion, free floating in the anterior chamber (12%) or in the vitreous (12%), or fixed in the anterior chamber angle (75%). One hundred twenty-four patients (53%) were followed for a mean of 35 months (range, 3 months-19 years). In these patients, complications associated with IPE cysts included lens subluxation in one case (1%), iritis in one case (1%), focal cataract in two cases (2%), glaucoma in two cases (2%), and corneal touch in five cases (4%). Conclusion: Primary IPE cysts have characteristic clinical features that serve to differentiate them from intraocular malignancies. Most cysts have a benign clinical course, and treatment is rarely necessary.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose. To identify changing trends in indications for penetrating keratoplasty and associated surgical procedures. Methods. Review of charts from all patients who underwent penetrating keratoplasty at Wills Eye Hospital from January 1, 1989 through December 31, 1995. Results. A total of 2,442 corneal transplants were performed in 2,186 patients. The leading indication for penetrating keratoplasty was pseudophakic corneal edema, accounting for 634 cases (26.0%); 54.7% of them were associated with anterior chamber intraocular lenses, 36.4% with posterior chamber intraocular lenses, and 3.1% with iris-fixated intraocular lenses. Regraft (17.8%), Fuchs' dystrophy (15.7%), and keratoconus (13.2%) followed pseudophakic corneal edema in frequency. Cataract extraction, with or without intraocular lens implantation, was combined with penetrating keratoplasty in 439 cases of 1,264 phakic eyes (34.7%). Intraocular lens exchange was performed in 285 of the 634 cases of pseudophakic cornea edema (44.9%). Conclusion. Pseudophakic corneal edema was the leading indication for penetrating keratoplasty, with an increasing number of cases associated with posterior chamber intraocular lenses during the study period (p = 0.001). The number of regrafts steadily increased between 1989 and 1995 (p = 0.001), being the second most common indication for corneal transplantation since 1992.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To report a new technique to correct tube position in anterior chamber after glaucoma drainage device implantation.

PATIENT AND METHODS: A patient who underwent a glaucoma drainage device implantation was noted to have the tube touching the corneal endothelium. A 10/0 polypropylene suture with double-armed 3-inch long straight needle was placed transcamerally from limbus to limbus, in the superior part of the eye, passing the needle in front of the tube.

RESULTS: The position of the tube in the anterior chamber was corrected with optimal distance from corneal endothelium and iris surface. The position remained satisfactory after 20 months of follow-up.

CONCLUSIONS: The placement of a transcameral suture offers a safe, quick, and minimal invasive intervention for the correction of the position of a glaucoma drainage device tube in the anterior chamber.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIM: To estimate the prevalence of primary angle closure glaucoma (PACG) in European derived populations.

METHOD: Systematic review and modelling of PACG prevalence data from population studies. PACG was defined according to the ISGEO definition requiring structural and/or functional evidence of glaucomatous optic neuropathy. Prevalence estimates were applied to the 2010 United Nations projected population figures to estimate case numbers.

RESULTS: The prevalence of PACG in those 40 years or more is 0.4% (95% CI 0.3% to 0.5%). Age-specific prevalence values are 0.02% (CI 0.00 to 0.08) for those 40-49 years, 0.60% (0.27 to 1.00) for those 50-59 years, 0.20% (0.06 to 0.42) for those 60-69 years and 0.94% (0.63 to 1.35) for those 70 years and older. Three-quarters of all cases occur in female subjects (3.25 female to 1 male; CI 1.76 to 5.94).

CONCLUSION: This analysis provides a current evidence-based estimate of PACG prevalence in European derived populations and suggests there are 130,000 people in the UK, 1.60 million people in Europe and 581,000 people in the USA with PACG today. Accounting for ageing population structures, cases are predicted to increase by 19% in the UK, 9% in Europe and 18% in the USA within the next decade. PACG is more common than previously thought, and all primary glaucoma cases should be considered to be PACG until the anterior chamber angle is shown to be open on gonioscopy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: To evaluate the outcome of Baerveldt implantation with adjunctive mitomycin-C in cases of complicated glaucoma. PATIENTS AND METHODS: The authors reviewed the charts of all patients who had undergone Baerveldt implantation with mitomycin-C between January 1993 and March 1995. Success was defined before data collection as an intraocular pressure (IOP) between 5 and 21 mm Hg, with or without medications. The success rate was calculated using the Kaplan-Meier actuarial method. RESULTS: Twenty-nine patients were identified. The mean preoperative IOP was 33.6 mm Hg, with an average of 2.0 antiglaucoma medications. The probability of success at 6 and 12 months for patients who received mitomycin-C during Baerveldt implantation was 82.4% and 73.3%, respectively. Choroidal effusion with a flat anterior chamber (10.3%), corneal edema (6.8%), and conjunctival erosion (6.8%) were the most frequent complications. CONCLUSION: In this retrospective series of complicated glaucoma, the implantation of a Baerveldt drainage device with adjunctive mitomycin-C had a satisfactory outcome. The complications encountered and the clinical efficacy were comparable to those of previously reported series in which mitomycin-C was not used.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Angle-closure glaucoma is a leading cause of irreversible blindness in the world. Treatment is aimed at opening the anterior chamber angle and lowering the IOP with medical and/or surgical treatment (e.g. trabeculectomy, lens extraction). Laser iridotomy works by eliminating pupillary block and widens the anterior chamber angle in the majority of patients. When laser iridotomy fails to open the anterior chamber angle, laser iridoplasty may be recommended as one of the options in current standard treatment for angle-closure. Laser peripheral iridoplasty works by shrinking and pulling the peripheral iris tissue away from the trabecular meshwork. Laser peripheral iridoplasty can be used for crisis of acute angle-closure and also in non-acute situations.

OBJECTIVES: To assess the effectiveness of laser peripheral iridoplasty in the treatment of narrow angles (i.e. primary angle-closure suspect), primary angle-closure (PAC) or primary angle-closure glaucoma (PACG) in non-acute situations when compared with any other intervention. In this review, angle-closure will refer to patients with narrow angles (PACs), PAC and PACG.

SEARCH METHODS: We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2011, Issue 12), MEDLINE (January 1950 to January 2012), EMBASE (January 1980 to January 2012), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to January 2012), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). There were no date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 5 January 2012.

SELECTION CRITERIA: We included only randomised controlled trials (RCTs) in this review. Patients with narrow angles, PAC or PACG were eligible. We excluded studies that included only patients with acute presentations, using laser peripheral iridoplasty to break acute crisis.

DATA COLLECTION AND ANALYSIS: No analysis was carried out as only one trial was included in the review.

MAIN RESULTS: We included one RCT with 158 participants. The trial reported laser peripheral iridoplasty as an adjunct to laser peripheral iridotomy compared to iridotomy alone. The authors report no superiority in using iridoplasty as an adjunct to iridotomy for IOP, number of medications or need for surgery.

AUTHORS' CONCLUSIONS: There is currently no strong evidence for laser peripheral iridoplasty's use in treating angle-closure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose. To evaluate agreement between clinical examination (slit lamp examination and gonioscopy) and ultrasound biomicroscopy (UBM) in characterizing various features of the anterior chamber angle and adjacent structures. Methods. Twenty-eight patients (51 eyes) with open angle glaucoma (14), closed angle glaucoma (4), narrow angle and/or plateau iris (10), who had undergone UBM between March 94 and September 95 were studied. Evaluated parameters included angle width, iris configuration and presence of angle closure. The UBMs were reviewed in a masked fashion. Results. In 87.8% of cases there was agreement (within 10 degrees) between gonioscopic and UBM estimates of angle width. In all cases with greater than 10 degrees difference (12.2%) the angle size estimated by UBM was less than that estimated clinically. Iris configuration was graded identically in 51% of cases; the majority of disagreements (76.1%) occurred in cases graded as "regular" by gonioscopy and as "steep" by UBM. Angle closure was judged to be present more frequently by UBM. Conclusions. UBM and gonioscopy do not necessarily yield identical values for angle width, iris configuration, and presence of angle closure.