995 resultados para Antenna measurement facilities


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is concerned with the implementation of a Mobile Broadband System, currently under research in Europe. We present a low-complexity, adaptive transceiver/antenna approach where simple, linear, phased arrays are adjusted under a transmission quality measurement provided by a decision-feedback equalizer. Several simulation results are presented and discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wireless networks have joined to the sports venues, offering to the public a set of facilities, such as the access to email, news, and also to use the social networking, uploading their photos. New challenges have emerged to provide Wi-Fi in this densely populated stadiums, such as increasing capacity and coverage. In this article, an access point antenna array to cover a sector of a stadium is presented. Its structure, designed in a low cost material allows to reduce the total manufacturing costs, an important factor due to the large number of antennas required in these venues. The material characteristic, the broad bandwidth of operation (300 MHz), along with to the low side lobe levels, important to reduce interference between sectors, makes this antenna well-positioned for wireless communications in these particular locals. (c) 2015 Wiley Periodicals, Inc. Microwave Opt Technol Lett 57:2037-2041, 2015.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Affiliation: Pierre Dagenais : Hôpital Maisonneuve-Rosemont, Faculté de médecine, Université de Montréal

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A quasi-optical interferometric technique capable of measuring antenna phase patterns without the need for a heterodyne receiver is presented. It is particularly suited to the characterization of terahertz antennas feeding power detectors or mixers employing quasi-optical local oscillator injection. Examples of recorded antenna phase patterns at frequencies of 1.4 and 2.5 THz using homodyne detectors are presented. To our knowledge, these are the highest frequency antenna phase patterns ever recovered. Knowledge of both the amplitude and phase patterns in the far field enable a Gauss-Hermite or Gauss-Laguerre beam-mode analysis to be carried out for the antenna, of importance in performance optimization calculations, such as antenna gain and beam efficiency parameters at the design and prototype stage of antenna development. A full description of the beam would also be required if the antenna is to be used to feed a quasi-optical system in the near-field to far-field transition region. This situation could often arise when the device is fitted directly at the back of telescopes in flying observatories. A further benefit of the proposed technique is simplicity for characterizing systems in situ, an advantage of considerable importance as in many situations, the components may not be removable for further characterization once assembled. The proposed methodology is generic and should be useful across the wider sensing community, e.g., in single detector acoustic imaging or in adaptive imaging array applications. Furthermore, it is applicable across other frequencies of the EM spectrum, provided adequate spatial and temporal phase stability of the source can be maintained throughout the measurement process. Phase information retrieval is also of importance to emergent research areas, such as band-gap structure characterization, meta-materials research, electromagnetic cloaking, slow light, super-lens design as well as near-field and virtual imaging applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Respiration chambers are one of the primary sources of data on methane emissions from livestock. This paper describes the results from a coordinated set of chamber validation experiments which establishes the absolute accuracy of the methane emission rates measured by the chambers, and for the first time provides metrological traceability to international standards, assesses the impact of both analyser and chamber response times on measurement uncertainty and establishes direct comparability between measurements made across different facilities with a wide range of chamber designs. As a result of the validation exercise the estimated combined uncertainty associated with the overall capability across all facilities reduced from 25.7% (k = 2, 95% confidence) before the validation to 2.1% (k = 2, 95% confidence) when the validation results are applied to the facilities’ data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report a measurement of the flux of cosmic rays with unprecedented precision and Statistics using the Pierre Auger Observatory Based on fluorescence observations in coincidence with at least one Surface detector we derive a spectrum for energies above 10(18) eV We also update the previously published energy spectrum obtained with the surface detector array The two spectra are combined addressing the systematic uncertainties and, in particular. the influence of the energy resolution on the spectral shape The spectrum can be described by a broken power law E(-gamma) with index gamma = 3 3 below the ankle which is measured at log(10)(E(ankle)/eV) = 18 6 Above the ankle the spectrum is described by a power law with index 2 6 followed by a flux suppression, above about log(10)(E/eV) = 19 5, detected with high statistical significance (C) 2010 Elsevier B V All rights reserved

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: The proportion of patients who die during or after surgery, otherwise known as the perioperative mortality rate (POMR), is a credible indicator of the safety and quality of operative care. Its accuracy and usefulness as a metric, however, particularly one that enables valid comparisons over time or between jurisdictions, has been limited by lack of a standardized approach to measurement and calculation, poor understanding of when in relation to surgery it is best measured, and whether risk-adjustment is needed. Our aim was to evaluate the value of POMR as a global surgery metric by addressing these issues using 4, large, mixed, surgical datasets that represent high-, middle-, and low-income countries. METHODS: We obtained data from the New Zealand National Minimum Dataset, the Geelong Hospital patient management system in Australia, and purpose-built surgical databases in Pietermaritzburg, South Africa, and Port Moresby, Papua New Guinea. For each site, we calculated the POMR overall as well as for nonemergency and emergency admissions. We assessed the effect of admission episodes and procedures as the denominator and the difference between in-hospital POMR and POMR, including postdischarge deaths up to 30 days. To determine the need for risk-adjustment for age and admission urgency, we used univariate and multivariate logistic regression to assess the effect on relative POMR for each site. RESULTS: A total of 1,362,635 patient admissions involving 1,514,242 procedures were included. More than 60% of admissions in Pietermaritzburg and Port Moresby were emergencies, compared with less than 30% in New Zealand and Geelong. Also, Pietermaritzburg and Port Moresby had much younger patient populations (P < .001). A total of 8,655 deaths were recorded within 30 days, and 8-20% of in-hospital deaths occurred on the same day as the first operation. In-hospital POMR ranged approximately 9-fold, from 0.38 per 100 admissions in New Zealand to 3.44 per 100 admissions in Pietermaritzburg. In New Zealand, in-hospital 30-day POMR underestimated total 30-day POMR by approximately one third. The difference in POMR if procedures were used instead of admission episodes ranged from 7 to 70%, although this difference was less when central line and pacemaker insertions were excluded. Age older than 65 years and emergency admission had large, independent effects on POMR but relatively little effect in multivariate analysis on the relative odds of in-hospital death at each site. CONCLUSION: It is possible to collect POMR in countries at all level of development. Although age and admission urgency are strong, independent associations with POMR, a substantial amount of its variance is site-specific and may reflect the safety of operative and anesthetic facilities and processes. Risk-adjustment is desirable but not essential for monitoring system performance. POMR varies depending on the choice of denominator, and in-hospital deaths appear to underestimate 30-day mortality by up to one third. Standardized approaches to reporting and analysis will strengthen the validity of POMR as the principal indicator of the safety of surgery and anesthesia care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: Most residents in residential aged care facilities are incontinent. This study explored how continence care was provided in residential aged care facilities, and describes a subset of data about staffs' beliefs and experiences of the quality framework and the funding model on residents' continence care.

Methods: Using grounded theory methodology, 18 residential aged care staff members were interviewed and 88 hours of field observations conducted in two facilities. Data were analysed using a combination of inductive and deductive analytic procedures.

Results: Staffs' beliefs and experiences about the requirements of the quality framework and the funding model fostered a climate of fear and risk adversity that had multiple unintended effects on residents' continence care, incentivising dependence on continence management, and equating effective continence care with effective pad use.

Conclusion: There is a need to rethink the quality of continence care and its measurement in Australian residential aged care facilities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The differential production cross section of electrons from semileptonic heavy-flavor hadron decays has been measured at midrapidity (\y\ < 0.5) in proton-proton collisions at root s = 7 TeV with ALICE at the LHC. Electrons were measured in the transverse momentum range 0.5 < p(t) < 8 GeV/c. Predictions from a fixed-order perturbative QCD calculation with next-to-leading-log resummation agree with the data within the theoretical and experimental uncertainties. DOI: 10.1103/PhysRevD.86.112007

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of event background fluctuations on charged particle jet reconstruction in Pb-Pb collisions at root s(NN) = 2.76 TeV has been measured with the ALICE experiment. The main sources of non-statistical fluctuations are characterized based purely on experimental data with an unbiased method, as well as by using single high p(t) particles and simulated jets embedded into real Pb-Pb events and reconstructed with the anti-k(t) jet finder. The influence of a low transverse momentum cut-off on particles used in the jet reconstruction is quantified by varying the minimum track p(t) between 0.15 GeV/c and 2 GeV/c. For embedded jets reconstructed from charged particles with p(t) > 0.15 GeV/c, the uncertainty in the reconstructed jet transverse momentum due to the heavy-ion background is measured to be 11.3 GeV/c (standard deviation) for the 10% most central Pb-Pb collisions, slightly larger than the value of 11.0 GeV/c measured using the unbiased method. For a higher particle transverse momentum threshold of 2 GeV/c, which will generate a stronger bias towards hard fragmentation in the jet finding process, the standard deviation of the fluctuations in the reconstructed jet transverse momentum is reduced to 4.8-5.0 GeV/c for the 10% most central events. A non-Gaussian tail of the momentum uncertainty is observed and its impact on the reconstructed jet spectrum is evaluated for varying particle momentum thresholds, by folding the measured fluctuations with steeply falling spectra.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ALICE experiment at the LHC has studied J/psi production at mid-rapidity in pp collisions at root s = 7 TeV through its electron pair decay on a data sample corresponding to an integrated luminosity L-int = 5.6 nb(-1). The fraction of J/psi from the decay of long-lived beauty hadrons was determined for J/psi candidates with transverse momentum p(t) > 1,3 GeV/c and rapidity vertical bar y vertical bar < 0.9. The cross section for prompt J/psi mesons, i.e. directly produced J/psi and prompt decays of heavier charmonium states such as the psi(2S) and chi(c) resonances, is sigma(prompt J/psi) (p(t) > 1.3 GeV/c, vertical bar y vertical bar < 0.9) = 8.3 +/- 0.8(stat.) +/- 1.1 (syst.)(-1.4)(+1.5) (syst. pol.) mu b. The cross section for the production of b-hadrons decaying to J/psi with p(t) > 1.3 GeV/c and vertical bar y vertical bar < 0.9 is a sigma(J/psi <- hB) (p(t) > 1.3 GeV/c, vertical bar y vertical bar < 0.9) = 1.46 +/- 0.38 (stat.)(-0.32)(+0.26) (syst.) mu b. The results are compared to QCD model predictions. The shape of the p(t) and y distributions of b-quarks predicted by perturbative QCD model calculations are used to extrapolate the measured cross section to derive the b (b) over bar pair total cross section and d sigma/dy at mid-rapidity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report a measurement of the proton-air cross section for particle production at the center-of-mass energy per nucleon of 57 TeV. This is derived from the distribution of the depths of shower maxima observed with the Pierre Auger Observatory: systematic uncertainties are studied in detail. Analyzing the tail of the distribution of the shower maxima, a proton-air cross section of [505 +/- 22(stat)(-36)(+28)(syst)] mb is found.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper a new 22 GHz water vapor spectro-radiometer which has been specifically designed for profile measurement campaigns of the middle atmosphere is presented. The instrument is of a compact design and has a simple set up procedure. It can be operated as a standalone instrument as it maintains its own weather station and a calibration scheme that does not rely on other instruments or the use of liquid nitrogen. The optical system of MIAWARA-C combines a choked gaussian horn antenna with a parabolic mirror which reduces the size of the instrument in comparison with currently existing radiometers. For the data acquisition a correlation receiver is used together with a digital cross correlating spectrometer. The complete backend section, including the computer, is located in the same housing as the instrument. The receiver section is temperature stabilized to minimize gain fluctuations. Calibration of the instrument is achieved through a balancing scheme with the sky used as the cold load and the tropospheric properties are determined by performing regular tipping curves. Since MIAWARA-C is used in measurement campaigns it is important to be able to determine the elevation pointing in a simple manner as this is a crucial parameter in the calibration process. Here we present two different methods; scanning the sky and the Sun. Finally, we report on the first spectra and retrieved water vapor profiles acquired during the Lapbiat campaign at the Finnish Meteorological Institute Arctic Research Centre in Sodankylä, Finland. The performance of MIAWARA-C is validated here by comparison of the presented profiles against the equivalent profiles from the Microwave Limb Sounder on the EOS/Aura satellite.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method to reduce truncation errors in near-field antenna measurements is presented. The method is based on the Gerchberg-Papoulis iterative algorithm used to extrapolate band-limited functions and it is able to extend the valid region of the calculated far-field pattern up to the whole forward hemisphere. The extension of the valid region is achieved by the iterative application of a transformation between two different domains. After each transformation, a filtering process that is based on known information at each domain is applied. The first domain is the spectral domain in which the plane wave spectrum (PWS) is reliable only within a known region. The second domain is the field distribution over the antenna under test (AUT) plane in which the desired field is assumed to be concentrated on the antenna aperture. The method can be applied to any scanning geometry, but in this paper, only the planar, cylindrical, and partial spherical near-field measurements are considered. Several simulation and measurement examples are presented to verify the effectiveness of the method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nowadays, more a more base stations are equipped with active conformal antennas. These antenna designs combine phase shift systems with multibeam networks providing multi-beam ability and interference rejection, which optimize multiple channel systems. GEODA is a conformal adaptive antenna system designed for satellite communications. Operating at 1.7 GHz with circular polarization, it is possible to track and communicate with several satellites at once thanks to its adaptive beam. The antenna is based on a set of similar triangular arrays that are divided in subarrays of three elements called `cells'. Transmission/Receiver (T/R) modules manage beam steering by shifting the phases. A more accurate steering of the antenna GEODA could be achieved by using a multibeam network. Several multibeam network designs based on Butler network will be presented