978 resultados para Aleph Version 18


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Saúde Coletiva - FMB

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this methodological study was to translate, culturally adapt and assess the internal consistency and validity of the Spanish version of the "Spirituality Questionnaire". The sample comprised 204 young people between 18 and 25 years of age from two universities in Bogota. Cronbach's Alpha was used for reliability, while groups of experts and young people were used for construct validity. The reliability score of the total instrument was 0.88. The overall index of content validity corresponded to 0.90. Exploratory factor analysis showed that four factors explain 52.60% of the variance. The originally proposed theoretical model was confirmed and, in two dimensions, a different structure was proposed. In conclusion, the instrument "Spirituality Questionnaire" by Parsian and Dunning is reliable and valid in the Spanish version.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim. The aim of this study was to evaluate the internal reliability and validity of the BrazilianPortuguese version of Duke Anticoagulation Satisfaction Scale (DASS) among cardiovascular patients. Background. Oral anticoagulation is widely used to prevent and treat thromboembolic events in several conditions, especially in cardiovascular diseases; however, this therapy can induce dissatisfaction and reduce the quality of life. Design. Methodological and cross-sectional research design. Methods. The cultural adaptation of the DASS included the translation and back-translation, discussions with healthcare professionals and patients to ensure conceptual equivalence, semantic evaluation and instrument pretest. The BrazilianPortuguese version of the DASS was tested among subjects followed in a university hospital anticoagulation outpatient clinic. The psychometric properties were assessed by construct validity (convergent, known groups and dimensionality) and internal consistency/reliability (Cronbachs alpha). Results. A total of 180 subjects under oral anticoagulation formed the baseline validation population. DASS total score and SF-36 domain correlations were moderate for General health (r = -0.47, p < 0.01), Vitality (r = -0.44, p < 0.01) and Mental health (r = -0.42, p < 0.01) (convergent). Age and length on oral anticoagulation therapy (in years) were weakly correlated with total DASS score and most of the subscales, except Limitation (r = -0.375, p < 0.01) (Known groups). The Cronbachs alpha coefficient was 0.79 for the total scale, and it ranged from 0.76 (hassles and burdens)0.46 (psychological impact) among the domains, confirming the internal consistency reliability. Conclusions. The BrazilianPortuguese version of the DASS has shown levels of reliability and validity comparable with the original English version. Relevance to clinical practice. Healthcare practitioners and researchers need internationally validated measurement tools to compare outcomes of interventions in clinical management and research tools in oral anticoagulation therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Piezoelectric ceramics, such as PZT, can generate subnanometric displacements, bu t in order to generate multi- micrometric displacements, they should be either driven by high electric voltages (hundreds of volts ), or operate at a mechanical resonant frequency (in narrow band), or have large dimensions (tens of centimeters). A piezoelectric flextensional actuator (PFA) is a device with small dimensions that can be driven by reduced voltages and can operate in the nano- and micro scales. Interferometric techniques are very adequate for the characterization of these devices, because there is no mechanical contact in the measurement process, and it has high sensitivity, bandwidth and dynamic range. A low cost open-loop homodyne Michelson interferometer is utilized in this work to experimentally detect the nanovi brations of PFAs, based on the spectral analysis of the interfero metric signal. By employing the well known J 1 ...J 4 phase demodulation method, a new and improved version is proposed, which presents the following characteristics: is direct, self-consistent, is immune to fading, and does not present phase ambiguity problems. The proposed method has resolution that is similar to the modified J 1 ...J 4 method (0.18 rad); however, differently from the former, its dynamic range is 20% larger, does not demand Bessel functions algebraic sign correction algorithms and there are no singularities when the static phase shift between the interferometer arms is equal to an integer multiple of  /2 rad. Electronic noise and random phase drifts due to ambient perturbations are taken into account in the analysis of the method. The PFA nanopositioner characterization was based on the analysis of linearity betw een the applied voltage and the resulting displacement, on the displacement frequency response and determination of main resonance frequencies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In der vorliegenden Arbeit werden vom ALEPH-Detektor am Speicherring LEP des CERN in Genf genommene Datenmengen aus den Jahren 1997 bis 1999 analysiert und sowohl Kopplungsparameter am Drei-Eichbosonen-Vertex derW-Boson-Paarproduktion, als auch die Anteile longitudinal beziehungsweise transversal polarisierter W-Bosonen, bei Schwerpunktsenergien von 183 GeV bis 202 GeV bestimmt. Betrachtet wird der rein leptonische Zerfallskanal, in dembeide W-Bosonen in ein Elektron-Neutrino- oder ein Myon-Neutrino-Paar zerfallen, der einen geringen Wirkungsquerschnitt aufweist, aber eine klareDetektorsignatur. Die aufgezeichneten Ereignisse werden selektiert und dabei eine Reinheit von durchschnittlich 72% erreicht. Der Hauptuntergrund besteht aus W-Boson-Paaren, bei denen zumindest ein W-Boson in ein Tauon-Neutrino-Paarzerfällt. Dieser Kanal zeigt ein sehr signalähnliches Verhalten. Die selektierten Ereignisse werden kinematisch rekonstruiert, um die Winkelverteilungen der Zerfallsprodukte der W-Bosonen zu extrahieren. Aus den Polarwinkelverteilungen der geladenen Zerfallsprodukte der W-Bosonen werden die Anteile longitudinal beziehungsweise transversal polarisierterW-Bosonen durch Anpassung der theoretischen Vorhersage an die selektierten Daten bestimmt. Dabei wird gefunden, daß f? = (71,6 ? 6,4_{stat.} ? 3,7_{syst.}) % der produzierten W-Bosonen transversal polarisiert sind, in Übereinstimmung mit der Vorhersage des Standardmodells (75,1%). Dieser Wert ist ein erster Hinweis auf die Kopplungsparameter am Drei-Eichbosonen-Vertex. Die CP-erhaltenden allgemeinen Kopplungsparameter $g_{rm Z}^1$, $kappa_gamma$ und $lambda_gamma$ werden bestimmt zu: $g_{rm Z}^1 = {{1,19^{+0,13}_{-0,16}}_{stat.}} {^{+0,09}_{-0,09}}_{syst.}$,$kappa_gamma = {{1,06^{+0,27}_{-0,09}}_{stat.}} {^{+0,08}_{-0,08}}_{syst.}$,$lambda_gamma = {{0,16^{+0,11}_{-0,13}}_{stat.}} {^{+0,08}_{-0,08}}_{syst.}$. Das Standardmodell sagt $g_{rm Z}^1 = 1$, $kappa_gamma = 1$ und $lambda_gamma = 0$ voraus. Mit diesen Kopplungsparametern lassen sich das magnetischeDipolmoment und das elektrische Quadrupolmoment der W-Bosonen bestimmen zu: $mu_{rm W} = frac{e}{2m_{rm W}} cdot (2,22^{+0,31}_{-0,19})$,$q_{rm W} = - frac{e}{m_{rm W}^2} cdot (0,90^{+0,32}_{-0,18})$. Die Messung der Kopplungsparameter stellt einen wichtigen Test des minimalen Standardmodells dar. In einem Jahr wird es möglich sein, diesen Test mit allen Daten aus der Phase II des Betriebs von LEP durchzuführen und die Genauigkeit durch Kombination mit anderen LEP-Experimenten zu erhöhen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The assessment of executive functions is an area of study that has seen considerable development in recent years. Despite much research examining the validity of various measures of executive functions from both a direct and indirect format, little evidence exists in the extant literature evaluating the correspondence between these types of measures. The current study examined the extent of correspondence, comprising concurrent validity, between the Delis-Kaplan Executive Function System (D-KEFS) and the Behavior Rating Inventory of Executive Function ¿ Self-Report Version (BRIEF-SR). Participants included 30 undergraduate and high school students 18 years of age. Results indicated mixed evidence of concurrent validity between the two measures of executive functions. The findings obtained suggest both expected significant, negative correlation as well as lack of expected correlation between the measures. Suggestions for future research in the assessment of executive functions are discussed.