1000 resultados para Air defenses -- Canada


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bioaerosols are a subgroup of atmospheric aerosols and are often linked to the spread of human, animal and plant diseases. Bioaerosols also may play an indirect effect on environmental processes, including the formation of precipitation and alteration of the global climate through their role as nuclei for cloud droplet formation. Several types of biological organisms (e.g., fungi and bacteria) have been shown to be effective ice nuclei (IN) and cloud condensation nuclei (CCN). During 21 days in August 2013 we participated in a collaborative international campaign at a rural, coastal site near the village of Ucluelet on the west coast of Vancouver Island, British Columbia, Canada. The experiments were conducted as part of the NETCARE project (the NETwork on Climate and Aerosols: Addressing Key Uncertainties in Remote Canadian Environments), in part to examine cloud nuclei properties of marine aerosol. The study was conducted from a mobile trailer located approximately 100 m from the coast. A suite of aerosol instrumentation was operated for approximately one month. Key instruments utilized as a part of this thesis include the wideband integrated bioaerosol sensor (WIBS-4A) and the multiple orifice uniform deposition impactor (MOUDI) coupled with an off-line droplet freezing technique (DFT) for the measurement of ice nucleation activity of particles in immersion mode. The WIBS measures the concentration and properties of individual fluorescent particles suspended in the air, which can serve as a proxy for airborne biological particle content. Particles shown to be fluorescent by the WIBS instrument were divided into seven categories based on the pattern of fluorescence each particle exhibited in the three fluorescent channels. Results of the WIBS analysis show that the fluorescent particle concentration in the region correlated well with IN number. The fluorescent particle concentration correlated well with the number of particles shown to be ice active as a function of both particle size and freezing temperature. Correlations involving marine aerosols and marine biological activity indicate that the majority of IN measured at the coastal site likely are not from have marine sources.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thermally driven liquid-desiccant air-conditioners (LDAC) are a proven but still developing technology. LDACs can use a solar thermal system to reduce the operational cost and environmental impact of the system by reducing the amount of fuel (e.g. natural gas, propane, etc.) used to drive the system. LDACs also have a key benefit of being able to store energy in the form of concentrated desiccant storage. TRNSYS simulations were used to evaluate several different methods of improving the thermal and electrical coefficients of performance (COPt and COPe) and the solar fraction (SF) of a LDAC. The study analyzed a typical June to August cooling season in Toronto, Ontario. Utilizing properly sized, high-efficiency pumps increased the COPe to 3.67, an improvement of 55%. A new design, featuring a heat recovery ventilator on the scavenging-airstream and an energy recovery ventilator on the process-airstream, increased the COPt to 0.58, an improvement of 32%. This also improved the SF slightly to 54%, an increase of 8%. A new TRNSYS TYPE was created to model a stratified desiccant storage tank. Different volumes of desiccant were tested with a range of solar array system sizes. The largest storage tank coupled with the largest solar thermal array showed improvements of 64% in SF, increasing the value to 82%. The COPe was also improved by 17% and the COPt by 9%. When combining the heat recovery systems and the desiccant storage systems, the simulation results showed a 78% increase in COPe and 30% increase in COPt. A 77% improvement in SF and a 17% increase in total cooling rate were also predicted by the simulation. The total thermal energy consumed was 10% lower and the electrical consumption was 34% lower. The amount of non-renewable energy needed from the natural gas boiler was 77% lower. Comparisons were also made between LDACs and vapour-compression (VC) systems. Dependent on set-up, LDACs provided higher latent cooling rates and reduced electrical power consumption. Negatively, a thermal input was required for the LDAC systems but not for the VC systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Time series of brightness temperatures (T(B)) from the Advanced Microwave Scanning Radiometer-Earth Observing System (AMSR-E) are examined to determine ice phenology variables on the two largest lakes of northern Canada: Great Bear Lake (GBL) and Great Slave Lake (GSL). T(B) measurements from the 18.7, 23.8, 36.5, and 89.0 GHz channels (H- and V- polarization) are compared to assess their potential for detecting freeze-onset/melt-onset and ice-on/ice-off dates on both lakes. The 18.7 GHz (H-pol) channel is found to be the most suitable for estimating these ice dates as well as the duration of the ice cover and ice-free seasons. A new algorithm is proposed using this channel and applied to map all ice phenology variables on GBL and GSL over seven ice seasons (2002-2009). Analysis of the spatio-temporal patterns of each variable at the pixel level reveals that: (1) both freeze-onset and ice-on dates occur on average about one week earlier on GBL than on GSL (Day of Year (DY) 318 and 333 for GBL; DY 328 and 343 for GSL); (2) the freeze-up process or freeze duration (freeze-onset to ice-on) takes a slightly longer amount of time on GBL than on GSL (about 1 week on average); (3) melt-onset and ice-off dates occur on average one week and approximately four weeks later, respectively, on GBL (DY 143 and 183 for GBL; DY 135 and 157 for GSL); (4) the break-up process or melt duration (melt-onset to ice-off) lasts on average about three weeks longer on GBL; and (5) ice cover duration estimated from each individual pixel is on average about three weeks longer on GBL compared to its more southern counterpart, GSL. A comparison of dates for several ice phenology variables derived from other satellite remote sensing products (e.g. NOAA Interactive Multisensor Snow and Ice Mapping System (IMS), QuikSCAT, and Canadian Ice Service Database) show that, despite its relatively coarse spatial resolution, AMSR-E 18.7 GHz provides a viable means for monitoring of ice phenology on large northern lakes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Division 1 "prepared under Subcontract 669-1 with Stanford Research Institute [by] Lehigh University, the Institute of Research."

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In northern regions where observational data is sparse, lake ice models are ideal tools as they can provide valuable information on ice cover regimes. The Canadian Lake Ice Model was used to simulate ice cover for a lake near Churchill, Manitoba, Canada throughout the 2008/2009 and 2009/2010 ice covered seasons. To validate and improve the model results, in situ measurements of the ice cover through both seasons were obtained using an upward-looking sonar device Shallow Water Ice Profiler (SWIP) installed on the bottom of the lake. The SWIP identified the ice-on/off dates as well as collected ice thickness measurements. In addition, a digital camera was installed on shore to capture images of the ice cover through the seasons and field measurements were obtained of snow depth on the ice, and both the thickness of snow ice (if present) and total ice cover. Altering the amounts of snow cover on the ice surface to represent potential snow redistribution affected simulated freeze-up dates by a maximum of 22 days and break-up dates by a maximum of 12 days, highlighting the importance of accurately representing the snowpack for lake ice modelling. The late season ice thickness tended to be under estimated by the simulations with break-up occurring too early, however, the evolution of the ice cover was simulated to fall between the range of the full snow and no snow scenario, with the thickness being dependant on the amount of snow cover on the ice surface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Twelve year datasets of weekly atmospheric concentrations of alpha- and gamma-HCH were compared between the two Arctic monitoring stations of Alert, Nunavut, Canada, and Zeppelin Mountain, Svalbard, Norway. Time-series analysis was conducted with the use of dynamic harmonic regression (DHR), which provided a very good model fit, to examine both the seasonal behaviour in these isomers and the longer-term, underlying trends. Strong spatial differences were not apparent between the two sites, although subtle differences in seasonal behaviour and composition were identified. For example, the composition of gamma-HCH to total HCH (alpha + gamma) was greater at Zeppelin compared to Alert, probably reflecting this site's proximity to major use regions of lindane. Pronounced seasonality in air concentrations for gamma-HCH was marked by a 'spring maximum event' (SME), confirming earlier studies. For alpha-HCH, the SME was much weaker and only evident at Alert, whereas at Zeppelin, seasonal fluctuations for alpha-HCH were marked by elevated concentrations in summer and lower concentrations during winter, with this pattern most apparent for the years after 2000. We attribute this difference in spatial and temporal patterns to the Arctic oscillation. A similar climatic pattern was not evident at either site in the gamma-HCH data. Seasonally adjusted, long-term trends revealed declining concentrations at both sites for alpha- and gamma-HCH over the entire time-series. Recent legislation affecting lindane use appear to account for this decline in gamma-HCH, with little evidence of a delay or 'lag' between the banning of lindane in Europe (a main source region) or Canada, and a decline in air concentrations observed at both Arctic sites.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thermally driven liquid-desiccant air-conditioners (LDAC) are a proven but still developing technology. LDACs can use a solar thermal system to reduce the operational cost and environmental impact of the system by reducing the amount of fuel (e.g. natural gas, propane, etc.) used to drive the system. LDACs also have a key benefit of being able to store energy in the form of concentrated desiccant storage. TRNSYS simulations were used to evaluate several different methods of improving the thermal and electrical coefficients of performance (COPt and COPe) and the solar fraction (SF) of a LDAC. The study analyzed a typical June to August cooling season in Toronto, Ontario. Utilizing properly sized, high-efficiency pumps increased the COPe to 3.67, an improvement of 55%. A new design, featuring a heat recovery ventilator on the scavenging-airstream and an energy recovery ventilator on the process-airstream, increased the COPt to 0.58, an improvement of 32%. This also improved the SF slightly to 54%, an increase of 8%. A new TRNSYS TYPE was created to model a stratified desiccant storage tank. Different volumes of desiccant were tested with a range of solar array system sizes. The largest storage tank coupled with the largest solar thermal array showed improvements of 64% in SF, increasing the value to 82%. The COPe was also improved by 17% and the COPt by 9%. When combining the heat recovery systems and the desiccant storage systems, the simulation results showed a 78% increase in COPe and 30% increase in COPt. A 77% improvement in SF and a 17% increase in total cooling rate were also predicted by the simulation. The total thermal energy consumed was 10% lower and the electrical consumption was 34% lower. The amount of non-renewable energy needed from the natural gas boiler was 77% lower. Comparisons were also made between LDACs and vapour-compression (VC) systems. Dependent on set-up, LDACs provided higher latent cooling rates and reduced electrical power consumption. Negatively, a thermal input was required for the LDAC systems but not for the VC systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Greenhouses have become an invaluable source of year-round food production. Further development of viable and efficient high performance greenhouses is important for future food security. Closing the greenhouse envelope from the environment can provide benefits in space heating energy savings, pest control, and CO2 enrichment. This requires the application of a novel air conditioning system to handle the high cooling loads experienced by a greenhouse. Liquid desiccant air-conditioning (LDAC) have been found to provide high latent cooling capacities, which is perfect for the application of a humid greenhouse microclimate. TRNSYS simulations were undertaken to study the feasibility of two liquid desiccant dehumidification systems based on their capacity to control the greenhouse microclimate, and their cooling performance. The base model (B-LDAC) included a natural gas boiler, and two cooling systems for seasonal operation. The second model (HP-LDAC) was a hybrid liquid desiccant-heat pump dehumidification system. The average tCOPdehum and tCOPtotal of the B-LDAC system increased from 0.40 and 0.56 in January to 0.94 and 1.09 in June. Increased load and performance during a sample summer day improved these values to 3.5 and 3.0, respectively. The average eCOPdehum and eCOPtotal values were 1.0 and 1.8 in winter, and 1.7 and 2.1 in summer. The HP-LDAC system produced similar daily performance trends where the annual average eCOPdehum and eCOPtotal values were 1.3 and 1.2, but the sample day saw peaks of 2.4 and 3.2, respectively. The B-LDAC and HP-LDAC results predicted greenhouse temperatures exceeding 30°C for 34% and 17% of the month of July, respectively. Similarly, humidity levels increased in summer months, with a maximum of 14% of the time spent over 80% in May for both models. The percentage of annual savings in space heating energy associated with closing the greenhouse to ventilation was 34%. The additional annual regeneration energy input was reduced by 26% to 526 kWhm-2, with the implementation of a heat recovery ventilator on the regeneration exhaust air. The models also predicted an electrical energy input of 245 kWhm-2 and 305 kWhm-2 for the B-LDAC and HP-LDAC simulations, respectively.