585 resultados para Adobe Photoshop
Resumo:
The aim of this study was to compare the efficacy of a direct clinical evaluation method with an indirect digital photographic method in assessing the quality of dental restorations. Seven parameters (color, occlusal marginal adaptation, anatomy form, roughness, occlusal marginal stain, luster, and secondary caries) were assessed in 89 Class I and Class II restorations from 36 adults using the modified US Public Health Service/Ryge criteria. Standardized photographs of the same restorations were digitally processed by Adobe Photoshop software, separated into the following four groups and assessed by two calibrated examiners: Group A: The original photograph displayed at 100%, without modifications (IMG100); Group B: Formed by images enlarged at 150% (IMG150); Group C: Formed by digital photographs displayed at 100% (mIMG100), with digital modifications (levels adjustment, shadow and highlight correction, color balance, unsharp Mask); and Group D: Formed by enlarged photographs displayed at 150% with modifications (mIMG150), with the same adjustments made to Group C. Photographs were assessed on a calibrated screen (Macbook) by two calibrated clinicians, and the results were statistically analyzed using Wilcoxon tests (SSPS 11.5) at 95% CI. Results: The photographic method produced higher reliability levels than the direct clinical method in all parameters. The evaluation of digital images is more consistent with clinical assessment when restorations present some moderate defect (Bravo) and less consistent when restorations are clinically classified as either satisfactory (Alpha) or in cases of severe defects (Charlie). Conclusion: The digital photographic method is a useful tool for assessing the quality of dental restorations, providing information that goes unnoticed with the visual-tactile clinical examination method. Additionally, when analyzing restorations using the Ryge modified criteria, the digital photographic method reveals a significant increase of defects compared to those clinically observed with the naked eye. Photography by itself, without the need for enlargement or correction, provides more information than clinical examination and can lead to unnecessary overtreatment.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The aim of this study was to assess the influence of the quantity of coloring agent on the bleaching efficiency of gels containing 35% H2O2. Sixty human third molars were sectioned mesiodistally, darkened in a coffee solution and sectioned in the occlusal-cervical direction, resulting in mesial (not bleached) and distal halves (bleached). They were distributed into three groups: Whiteness HP, Total Bleach, and Whiteform Perox Red Gel; and subdivided into four sub-groups: no coloring agent, manufacturer's standard, double the standard, and triple the standard. The gels were activated with light-ermitting diode/laser appliances. The images were analyzed with the Adobe Photoshop program (deltaEL*a*b*). The variation was submitted to the ANOVA test (two factors: type of gel and quantity of coloring agent) and Tukey test. Differences were observed for the quantity of coloring agent. The mean (+/-SD) was determined for each quantity of coloring used: no coloring agent -6.85 (+/-2.26)a, manufacturer's standard -794 (+/-2.55)ab, double the standard -8.65 (+/-2.47)b, triple the standard -9.05 (+/-2.72)b. In conclusion, the standard quantity of coloring agent did not provide significantly more intense bleaching than when it was completely absent. The use of double and triple the amount provided greater bleaching than that observed for the gel without coloring agent. No significant differences were observed between the tested gels.
Resumo:
This study investigated the biomechanical behavior of screwed partial fixed prosthesis supported by implants with different diameters (2.5 mm; 3.3 mm and 3.75 mm) by using a photoelastic analysis. Six photoelastic models were fabricated in PL-2 resin as single crowns or splinted 3-unit piece. Models were positioned in a circular polariscope and 100-N axial and oblique (45 degrees) loads were applied in the occlusal surface of the crowns by using a universal testing machine (EMIC). The stresses were photographically recorded and qualitatively analyzed using a software (Adobe Photoshop). Under axial loading, the number of fringes was inversely proportional to the diameter of the implants in the single crown models. In the splinted 3-unit piece, the 3.75-mm implant promoted lower number of fringes regardless of loading area application. Under oblique loading, a slight increase of fringes number was observed for all groups. The standard implant diameter promoted better stress distribution than the narrow and mini diameter implants. Additionally, the splinted crowns showed a more uniform stress distribution.
Resumo:
The aim of this study was to evaluate the influence of implant angulation and abutment type (UCLA and Estheticone) on stress distribution in screw-retained implant-supported prostheses through photoelasticity. Three models were fabricated with photoelastic resin PL-2 (Vishay, Micro-Measurements Group, Inc Raleigh, N.C., USA) containing one external hexagon implant with 3.75x10mm (Master screw, Conexão Sistemas de Prótese Ltda., Arujá, São Paulo) with 0°, 17° and 30° degrees and a screw-retained prostheses with UCLA and Estheticone abutments. The assembly was positioned in a circular polariscope; axial and oblique (45° degrees) loads of 100N were applied in fixed points on the occlusal crown surfaces by a universal testing machine. The stress generated was photographed and analyzed qualitatively with appropriate software (Adobe Photoshop®). The results demonstrated the same number of fringes for both abutment types for each angulation, with fringes increasing in the same way. A higher number of fringes were closer in the oblique loading mode. It was concluded that there was no significant difference in stress distribution in prostheses with UCLA and Estheticone abutments. Higher stress concentrations were observed with increased implant angulation. Stress concentration and intensity were higher in the oblique load than in axial load application.
Resumo:
Purpose: Ti-Ta alloys have high potential for dental application due to a good balance between high strength and low modulus. Absence of primary anchoring may occur when dental implants are installed immediately after tooth extraction. Tranexamic acid (TEA) is used to reduce fibrin degradation and can prevent early blood clot breakdown. The aim of this study was to evaluate the biocompatibility of Ti-30Ta implants associated or not with tranexamic acid and installed with compromised primary stability. Methods and materials: Fabricated were 20 implants of titanium ASTM F67 (Grade 4) and 20 implants of Ti-30Ta alloy with dimensions of 2.1 mm × 2.8 mm Ø. They were divided (n = 10) into Group I (Ti machined), Group II (Ti machined/tranexamic acid), Group III (Ti-30Ta alloy) and Group IV (Ti-30Ta/tranexamic acid) and were implanted in tibia (defects with 2.5 mm × 3.2 mm Ø) of 40 male rats (250 g). The surgical sites were rinsed with 5% tranexamic acid solution in Groups II and IV. The animals were euthanized at 45 days postoperative. The pieces were processed in methyl methacrylate (Stevenel's blue/Alizarin red). The percentage of peri-implant tissue repair was analyzed via images obtained by an optical microscope coupled to a digital camera using Leica software and Adobe Photoshop QWin. Data were analyzed statistically with a significance level of 5%. Results: Histomorphometric results showed 97.16% of bone-implant contact for group IV, 89.78% of bone contact for group III, 70.89% for group II and 61.59% of bone contact for group I. The statistical analyses demonstrated significant differences (P < 0.05) among group I and other groups. Conclusion: The results suggest that (a) Ti-30Ta promoted an increase of bone healing and apposition around implant; (b) tranexamic acid favored the stabilization of blood clot and bone formation.
Resumo:
Objective: To evaluate the degree of perception of laypersons, dental professionals, and dental students regarding dental esthetics in cases with mandibular central incisor extraction. Materials and Methods: Using a smile photograph of a person with normal occlusion and all teeth, modifications were made to reflect the extraction of a mandibular incisor of various compositions and sizes. For this purpose a program specifically for image manipulation (Adobe Photoshop CS3, Adobe Systems Inc) was used. After manipulation the images were printed on photographic paper, attached to a questionnaire and distributed to laypersons, dental professionals, and dental students (n = 90) to evaluate the degree of perception and esthetic using a scale of attractiveness, where 0 = hardly attractive, 5 = attractive, and 10 = very attractive. The differences between examiners were checked by the Mann-Whitney test. All the statistics were performed with a confidence level of 95%. Results: The results demonstrated the skill of the dental professionals and dental students in perceiving the difference between cases of normal occlusion and cases where an incisor was lacking (P < .05). The photograph in which the lateral incisors were shown to be larger than the central incisor was the one that obtained the highest value among the cases of extraction in all groups of evaluators. Conclusions: It can be concluded that dental professionals and dental students are more skillful at identifying deviation from normality. In addition, central incisor extraction should always be discarded when there are other treatment options available. (Angle Orthod. 2012;82:732-738.)
Resumo:
PURPOSE: To compare the direct and indirect radiographic methods for assessing the gray levels of biomaterials employing the Digora for Windows and the Adobe Photoshop CS2 systems. METHODS: Specimens of biomaterials were made following manusfacturer's instructions and placed on phosphor storage plates (PSP) and on radiographic film for subsequent gray level assessment using the direct and indirect radiographic method, respectively. The radiographic density of each biomaterial was analyzed using Adobe Photoshop CS2 and Digora for Windows software. RESULTS: The distribution of gray levels found using the direct and indirect methods suggests that higher exposure times are correlated to lower reproducibility rates between groups. CONCLUSION: The indirect method is a feasible alternative to the direct method in assessing the radiographic gray levels of biomaterials, insofar as significant reproducibility was observed between groups for the exposure times of 0.2 to 0.5 seconds.
Resumo:
This work is focused on the reconstruction of the intellectual biography of Francesco Platone de' Benedetti, prince of the Bologna's printers (1482-1486), that is the same with his typographical outputs. The research had been divided in two parts: the first, with his life, invesitigated by archive documents, and the second part, focused on the census of his editions, with a particular attention to his types. The research on the typographical types had been developed with Adobe Photoshop, that had allowed me to virtually reconstruct the cases of the Gotic and Roman types used by de' Benedetti.
Resumo:
Vast portions of Arctic and sub-Arctic Siberia, Alaska and the Yukon Territory are covered by ice-rich silty to sandy deposits that are containing large ice wedges, resulting from syngenetic sedimentation and freezing. Accompanied by wedge-ice growth in polygonal landscapes, the sedimentation process was driven by cold continental climatic and environmental conditions in unglaciated regions during the late Pleistocene, inducing the accumulation of the unique Yedoma deposits up to >50 meters thick. Because of fast incorporation of organic material into syngenetic permafrost during its formation, Yedoma deposits include well-preserved organic matter. Ice-rich deposits like Yedoma are especially prone to degradation triggered by climate changes or human activity. When Yedoma deposits degrade, large amounts of sequestered organic carbon as well as other nutrients are released and become part of active biogeochemical cycling. This could be of global significance for future climate warming as increased permafrost thaw is likely to lead to a positive feedback through enhanced greenhouse gas fluxes. Therefore, a detailed assessment of the current Yedoma deposit coverage and its volume is of importance to estimate its potential response to future climate changes. We synthesized the map of the coverage and thickness estimation, which will provide critical data needed for further research. In particular, this preliminary Yedoma map is a great step forward to understand the spatial heterogeneity of Yedoma deposits and its regional coverage. There will be further applications in the context of reconstructing paleo-environmental dynamics and past ecosystems like the mammoth-steppe-tundra, or ground ice distribution including future thermokarst vulnerability. Moreover, the map will be a crucial improvement of the data basis needed to refine the present-day Yedoma permafrost organic carbon inventory, which is assumed to be between 83±12 (Strauss et al., 2013, doi:10.1002/2013GL058088) and 129±30 (Walter Anthony et al., 2014, doi:10.1038/nature13560) gigatonnes (Gt) of organic carbon in perennially-frozen archives. Hence, here we synthesize data on the circum-Arctic and sub-Arctic distribution and thickness of Yedoma for compiling a preliminary circum-polar Yedoma map. For compiling this map, we used (1) maps of the previous Yedoma coverage estimates, (2) included the digitized areas from Grosse et al. (2013) as well as extracted areas of potential Yedoma distribution from additional surface geological and Quaternary geological maps (1.: 1:500,000: Q-51-V,G; P-51-A,B; P-52-A,B; Q-52-V,G; P-52-V,G; Q-51-A,B; R-51-V,G; R-52-V,G; R-52-A,B; 2.: 1:1,000,000: P-50-51; P-52-53; P-58-59; Q-42-43; Q-44-45; Q-50-51; Q-52-53; Q-54-55; Q-56-57; Q-58-59; Q-60-1; R-(40)-42; R-43-(45); R-(45)-47; R-48-(50); R-51; R-53-(55); R-(55)-57; R-58-(60); S-44-46; S-47-49; S-50-52; S-53-55; 3.: 1:2,500,000: Quaternary map of the territory of Russian Federation, 4.: Alaska Permafrost Map). The digitalization was done using GIS techniques (ArcGIS) and vectorization of raster Images (Adobe Photoshop and Illustrator). Data on Yedoma thickness are obtained from boreholes and exposures reported in the scientific literature. The map and database are still preliminary and will have to undergo a technical and scientific vetting and review process. In their current form, we included a range of attributes for Yedoma area polygons based on lithological and stratigraphical information from the original source maps as well as a confidence level for our classification of an area as Yedoma (3 stages: confirmed, likely, or uncertain). In its current version, our database includes more than 365 boreholes and exposures and more than 2000 digitized Yedoma areas. We expect that the database will continue to grow. In this preliminary stage, we estimate the Northern Hemisphere Yedoma deposit area to cover approximately 625,000 km². We estimate that 53% of the total Yedoma area today is located in the tundra zone, 47% in the taiga zone. Separated from west to east, 29% of the Yedoma area is found in North America and 71 % in North Asia. The latter include 9% in West Siberia, 11% in Central Siberia, 44% in East Siberia and 7% in Far East Russia. Adding the recent maximum Yedoma region (including all Yedoma uplands, thermokarst lakes and basins, and river valleys) of 1.4 million km² (Strauss et al., 2013, doi:10.1002/2013GL058088) and postulating that Yedoma occupied up to 80% of the adjacent formerly exposed and now flooded Beringia shelves (1.9 million km², down to 125 m below modern sea level, between 105°E - 128°W and >68°N), we assume that the Last Glacial Maximum Yedoma region likely covered more than 3 million km² of Beringia. Acknowledgements: This project is part of the Action Group "The Yedoma Region: A Synthesis of Circum-Arctic Distribution and Thickness" (funded by the International Permafrost Association (IPA) to J. Strauss) and is embedded into the Permafrost Carbon Network (working group Yedoma Carbon Stocks). We acknowledge the support by the European Research Council (Starting Grant #338335), the German Federal Ministry of Education and Research (Grant 01DM12011 and "CarboPerm" (03G0836A)), the Initiative and Networking Fund of the Helmholtz Association (#ERC-0013) and the German Federal Environment Agency (UBA, project UFOPLAN FKZ 3712 41 106).
Resumo:
Curimatídeos do gênero Cyphocharax Fowler, 1906 distribuem-se amplamente nas bacias hidrográficas da América do Sul, contudo essa ampla distribuição inequivale a quantidade de trabalhos relacionados ao gênero. Visto isso, objetivou-se contribuir ao conhecimento de Cyphocarax gouldingi (Vari, 1992) através da caracterização morfométrica de indivíduos coletados na microbacia do rio Praquiquara, localizado no médio Apeú, Amazônia Oriental. Para a determinação morfométrica da espécie, utilizou-se o software Adobe Photoshop CS6 Extended, mensurando os respectivos caracteres merísticos: comprimentos total, padrão, zoológico, cabeça e focinho, a medida da altura e o diâmetro do olho de 178 exemplares capturados entre os meses setembro (2014) e maio (2015). Verificou-se uma correlação forte positiva e alometria negativa, entre o comprimento total e as demais medidas externas, e observou a importância do rio Praquiquara durante o ciclo de vida da espécie. Conclui-se que as medidas morfométricas de C. gouldingi (1) satisfazem a estimação de comprimento total e (2) possibilitam o estudo sobre a dinâmica de crescimento da espécie estudada.
Resumo:
El proyecto consta de dos partes principales y dos anexos. La primera es teórica, en ella realizamos; a modo de introducción, un estudio sobre el tratamiento digital de la imagen, desarrollando las principales técnicas de tratamiento y análisis de imágenes que pudimos estudiar durante la carrera. Una vez desgranado el análisis nos centraremos en la correlación digital de imagen, su evolución y distintas técnicas, donde nos centramos en la correlación cruzada normalizada que usamos posteriormente para la correlación de imágenes con Matlab. La segunda parte consiste en la implementación de un sencillo programa mediante Matlab en el que podremos evaluar y analizar las diferencias entre dos o más imágenes, pudiendo observar gráficamente la desviación en milímetros entre varias imágenes y su dirección con vectores. Posteriormente analizamos los resultados obtenidos y proponemos posibles mejoras para futuros proyectos de correlación de imágenes digitales. Por último, incluimos un par de anexos en los que incluimos un tutorial para automatizar acciones con Adobe Photoshop para facilitar el pretratamiento de fotografías antes de analizarlas con el script y una posible práctica de laboratorio para futuros alumnos de la escuela utilizando nuestro script de Matlab. ABSTRACT. The project involves two main parts and two annexes. The first is theoretical, it performed; by way of introduction, a study on digital image processing, developing the main treatment techniques and image analysis we were able to study along our career. Once shelled analysis we will focus on digital image correlation, evolution and different techniques, where we focus on normalized cross-correlation which we use later for the correlation of images with Matlab. The second part is the implementation of a simple program using Matlab where we can evaluate and analyze the differences between two or more images and can graphically see the deviation in millimeters between various images and their direction vectors. Then we analyze the results and propose possible improvements for future projects correlation of digital images. Finally, we have a couple of annexes in which we include a tutorial to automate actions with Adobe Photoshop to facilitate pretreatment photographs before analyzing the script and a possible lab for future school students using our Matlab script.
Resumo:
The desire to create unique things and give free rain to one's imagination served as a powerful impetus to the development of digital art and design software. The commoner was the use of computers the wider variety of professional software was developed. Nowadays the creators and computer designers are receiving more and more new and advanced programs that allow their ideas becoming virtual reality. This research paper looks at the history of the development of graphic editors from the simplest to the most modern and advanced. This brief survey includes the history of different graphic editors’ creation, their features and abilities. This paper highlights the two basic branches of graphic editors – these that are in free use and commercial graphic editors design software. The researcher selected the most powerful and influential graphic editors design software brands like Paint.NET and GIMP among free software and commercial Adobe Photoshop. This paper also dwells upon the way digital art transferred from the exclusively professional business into the hobby for ordinary users. This research paper bears implications for those who are interested in features and potentiality of most popular graphic editors design software.
Resumo:
This presentation was given at the Panhandle Library Access Network's (PLAN) Innovation Conference: Digitization- Preserving the Past for the Future Conference on August 14th, 2015. The presentation uses a specific collection of directories as a case study of the complications librarians and archivists face in digitizing older materials that may also be quite large, such as a directory. Prime OCR and Abbyy Fine Reader are discussed and their pros and cons covered. Troubleshooting and editing with Adobe Photoshop is also discussed.
Resumo:
Today, an Australian parliamentary committee grilled the IT titans - Apple, Adobe, and Microsoft - on price discrimination against Australian consumers. The IT companies were evasive under questioning.