973 resultados para Acoustic radars


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acoustic emission avalanche distributions are studied in different alloy systems that exhibit a phase transition from a bcc to a close-packed structure. After a small number of thermal cycles through the transition, the distributions become critically stable (exhibit power-law behavior) and can be characterized by an exponent alpha. The values of alpha can be classified into universality classes, which depend exclusively on the symmetry of the resulting close-packed structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: We investigated the influence of beam modulation on treatment planning by comparing four available stereotactic radiosurgery (SRS) modalities: Gamma-Knife-Perfexion, Novalis-Tx Dynamic-Conformal-Arc (DCA) and Dynamic-Multileaf-Collimation-Intensity-Modulated-radiotherapy (DMLC-IMRT), and Cyberknife. MATERIAL AND METHODS: Patients with arteriovenous malformation (n = 10) or acoustic neuromas (n = 5) were planned with different treatment modalities. Paddick conformity index (CI), dose heterogeneity (DH), gradient index (GI) and beam-on time were used as dosimetric indices. RESULTS: Gamma-Knife-Perfexion can achieve high degree of conformity (CI = 0.77 ± 0.04) with limited low-doses (GI = 2.59 ± 0.10) surrounding the inhomogeneous dose distribution (D(H) = 0.84 ± 0.05) at the cost of treatment time (68.1 min ± 27.5). Novalis-Tx-DCA improved this inhomogeneity (D(H) = 0.30 ± 0.03) and treatment time (16.8 min ± 2.2) at the cost of conformity (CI = 0.66 ± 0.04) and Novalis-TX-DMLC-IMRT improved the DCA CI (CI = 0.68 ± 0.04) and inhomogeneity (D(H) = 0.18 ± 0.05) at the cost of low-doses (GI = 3.94 ± 0.92) and treatment time (21.7 min ± 3.4) (p<0.01). Cyberknife achieved comparable conformity (CI = 0.77 ± 0.06) at the cost of low-doses (GI = 3.48 ± 0.47) surrounding the homogeneous (D(H) = 0.22 ± 0.02) dose distribution and treatment time (28.4min±8.1) (p<0.01). CONCLUSIONS: Gamma-Knife-Perfexion will comply with all SRS constraints (high conformity while minimizing low-dose spread). Multiple focal entries (Gamma-Knife-Perfexion and Cyberknife) will achieve better conformity than High-Definition-MLC of Novalis-Tx at the cost of treatment time. Non-isocentric beams (Cyberknife) or IMRT-beams (Novalis-Tx-DMLC-IMRT) will spread more low-dose than multiple isocenters (Gamma-Knife-Perfexion) or dynamic arcs (Novalis-Tx-DCA). Inverse planning and modulated fluences (Novalis-Tx-DMLC-IMRT and CyberKnife) will deliver the most homogeneous treatment. Furthermore, Linac-based systems (Novalis and Cyberknife) can perform image verification at the time of treatment delivery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[Introduction (extrait)] Si l'on connaît généralement les revues systématiques dans le domaine médical ou des soins, l'évaluation de l'efficacité d'une intervention technique ou structurelle en dehors de ces domaines est moins connue. Le but est cependant similaire : quelles preuves a-t-on qu'une intervention soit efficace pour améliorer la santé de la population ou d'une personne ? L'article ci-dessous présente une revue systématique en prévention et santé publique

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The growth rate of acoustic tumors, although slow, varies widely. There may be a continuous spectrum or distinct groups of tumor growth rates. Clinical, audiologic, and conventional histologic tests have failed to shed any light on this problem. Modern immunohistochemical methods may stand a better chance. The Ki-67 monoclonal antibody stains proliferating cells and is used in this study to investigate the growth fraction of 13 skull base schwannomas. The acoustic tumors can be divided into two different growth groups, one with a rate five times the other. The literature is reviewed to see if this differentiation is borne out by the radiologic studies. Distinct growth rates have been reported: one very slow, taking 50 years to reach 1 cm in diameter, a second rate with a diameter increase of 0.2 cm/year, and a third rate five times the second, with a 1.0 cm increase in diameter per year. A fourth group growing at 2.5 cm/year is postulated, but these tumors cannot be followed for long radiologically, since symptoms demand surgical intervention. The clinical implications of these separate growth rates are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous research has provided inconsistent results regarding the spatial modulation of auditory-somatosensory interactions. The present study reports three experiments designed to investigate the nature of these interactions in the space close to the head. Human participants made speeded detection responses to unimodal auditory, somatosensory, or simultaneous auditory-somatosensory stimuli. In Experiment 1, electrocutaneous stimuli were presented to either earlobe, while auditory stimuli were presented from the same versus opposite sides, and from one of two distances (20 vs. 70cm) from the participant's head. The results demonstrated a spatial modulation of auditory-somatosensory interactions when auditory stimuli were presented from close to the head. In Experiment 2, electrocutaneous stimuli were delivered to the hands, which were placed either close to or far from the head, while the auditory stimuli were again presented at one of two distances. The results revealed that the spatial modulation observed in Experiment 1 was specific to the particular body part stimulated (head) rather than to the region of space (i.e. around the head) where the stimuli were presented. The results of Experiment 3 demonstrate that sounds that contain high-frequency components are particularly effective in eliciting this auditory-somatosensory spatial effect. Taken together, these findings help to resolve inconsistencies in the previous literature and suggest that auditory-somatosensory multisensory integration is modulated by the stimulated body surface and acoustic spectra of the stimuli presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acoustic waveform inversions are an increasingly popular tool for extracting subsurface information from seismic data. They are computationally much more efficient than elastic inversions. Naturally, an inherent disadvantage is that any elastic effects present in the recorded data are ignored in acoustic inversions. We investigate the extent to which elastic effects influence seismic crosshole data. Our numerical modeling studies reveal that in the presence of high contrast interfaces, at which P-to-S conversions occur, elastic effects can dominate the seismic sections, even for experiments involving pressure sources and pressure receivers. Comparisons of waveform inversion results using a purely acoustic algorithm on synthetic data that is either acoustic or elastic, show that subsurface models comprising small low-to-medium contrast (?30%) structures can be successfully resolved in the acoustic approximation. However, in the presence of extended high-contrast anomalous bodies, P-to-S-conversions may substantially degrade the quality of the tomographic images. In particular, extended low-velocity zones are difficult to image. Likewise, relatively small low-velocity features are unresolved, even when advanced a priori information is included. One option for mitigating elastic effects is data windowing, which suppresses later arriving seismic arrivals, such as shear waves. Our tests of this approach found it to be inappropriate because elastic effects are also included in earlier arriving wavetrains. Furthermore, data windowing removes later arriving P-wave phases that may provide critical constraints on the tomograms. Finally, we investigated the extent to which acoustic inversions of elastic data are useful for time-lapse analyses of high contrast engineered structures, for which accurate reconstruction of the subsurface structure is not as critical as imaging differential changes between sequential experiments. Based on a realistic scenario for monitoring a radioactive waste repository, we demonstrated that acoustic inversions of elastic data yield substantial distortions of the tomograms and also unreliable information on trends in the velocity changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hearing loss can be caused by a variety of insults, including acoustic trauma and exposure to ototoxins, that principally effect the viability of sensory hair cells via the MAP kinase (MAPK) cell death signaling pathway that incorporates c-Jun N-terminal kinase (JNK). We evaluated the otoprotective efficacy of D-JNKI-1, a cell permeable peptide that blocks the MAPK-JNK signal pathway. The experimental studies included organ cultures of neonatal mouse cochlea exposed to an ototoxic drug and cochleae of adult guinea pigs that were exposed to either an ototoxic drug or acoustic trauma. Results obtained from the organ of Corti explants demonstrated that the MAPK-JNK signal pathway is associated with injury and that blocking of this signal pathway prevented apoptosis in areas of aminoglycoside damage. Treatment of the neomycin-exposed organ of Corti explants with D-JNKI-1 completely prevented hair cell death initiated by this ototoxin. Results from in vivo studies showed that direct application of D-JNKI-1 into the scala tympani of the guinea pig cochlea prevented nearly all hair cell death and permanent hearing loss induced by neomycin ototoxicity. Local delivery of D-JNKI-1 also prevented acoustic trauma-induced permanent hearing loss in a dose-dependent manner. These results indicate that the MAPK-JNK signal pathway is involved in both ototoxicity and acoustic trauma-induced hair cell loss and permanent hearing loss. Blocking this signal pathway with D-JNKI-1 is of potential therapeutic value for long-term protection of both the morphological integrity and physiological function of the organ of Corti during times of oxidative stress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reaaliaikainen, ennakoiva kunnonvalvonta on erittäin tärkeä osa modernin tehtaan tai tuotantolinjan toimintaa. Diplomityön teettäjä haluaa edelleen kehittää akustiseen emissioon perustuvaa kunnonvalvonta järjestelmäänsä, jotta siitä olisi enemmän hyötyä asiakkaalle. Diplomityö sisältää johdannonakustiseen emissioon ja akustisiin emissio sensoreihin. Työn tavoitteena oli kehittää päätöksentekojärjestelmä, jota käytettäisiin työn teettäjän valmistamien sensoreiden antaman tiedon automatisoituun analysointiin. Työssä on vertailtu kolmea eri ohjelmistotoimittajaa ja heidän ohjelmiaan, ja tehty ehdotus hankittavasta ohjelmistosta. Lisäksi työssä on kehitetty ohjeita, joiden avulla ohjelmisto ohjelmoidaan tuottamaan reaaliaikaista tietoa ja huolto-ohjeita sen käyttäjille. Lisäksi työssä annetaan ehdotuksia kunnonvalvonta- ja päätöksentekojärjestelmän edelleen kehittämiseen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Five village soundscapes toim./ed. R. M. Schafer. kirjan liitteinä olevista CD-levyistä kaksi liittyy teokseen Acoustic environments in change ja kaksi teokseen Five village soundscapes. Five villages soundscapes. 1st ed. Vancouver : A.R.C. Publications, cop. 1977.

Relevância:

20.00% 20.00%

Publicador: