986 resultados para Acoustic Measurements.


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Radial profiles are reported of average and rms temperature in a propane flame for the first, second, and third acoustic modes at four different axial positions above the burner in a Rijke-tube combustor. Selected plots of the power spectral density (PSD) of temperature fluctuations are also reported. These radial profiles are then compared to similar ones made in the same flame, but in the absence of the acoustic field. Visual observations and photographs of the flame showed a remarkable change in flame height and structure with the onset of acoustic oscillations. This reduction in flame length, caused by the enhanced mixing due to the acoustic velocity fluctuations, gave rise to higher and lower average and rms temperatures near or well above the burner, respectively. In general, the PSD plots had a broad frequency content. The general trend was a decrease in magnitude with an increase in frequency. All cases presented broad-band peaks at around 5 Hz related to the flame flickering phenomenon. Preferred frequencies were observed in the oscillating PSD plots related to the fundamental frequency as well as subharmonics in the tube. (C) 2000 Elsevier B.V. Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The present study sought to assess nasal respiratory function in adult patients with maxillary constriction who underwent surgically assisted rapid maxillary expansion (SARME) and to determine correlations between orthodontic measurements and changes in nasal area, volume, resistance, and airflow. Twenty-seven patients were assessed by acoustic rhinometry, rhinomanometry, orthodontic measurements, and use of a visual analogue scale at three time points: before surgery; after activation of a preoperatively applied palatal expander; and 4 months post-SARME. Results showed a statistically significant increase (p < 0.001) in all orthodontic measurements. The overall area of the nasal cavity increased after surgery (p < 0.036). The mean volume increased between assessments, but not significantly. Expiratory and inspiratory flow increased over time (p < 0.001). Airway resistance decreased between assessments (p < 0.004). Subjective analysis of the feeling of breathing exclusively through the nose increased significantly from one point in time to the next (p < 0.05). There was a statistical correlation between increased arch perimeter and decreased airway resistance. Respiratory flow was the only variable to behave differently between sides. The authors conclude that the SARME procedure produces major changes in the oral and nasal cavity; when combined, these changes improve patients' quality of breathing.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The new Spanish Regulation in Building Acoustic establishes values and limits for the different acoustic magnitudes whose fulfillment can be verify by means field measurements. In this sense, an essential aspect of a field measurement is to give the measured magnitude and the uncertainty associated to such a magnitude. In the calculus of the uncertainty it is very usual to follow the uncertainty propagation method as described in the Guide to the expression of Uncertainty in Measurements (GUM). Other option is the numerical calculus based on the distribution propagation method by means of Monte Carlo simulation. In fact, at this stage, it is possible to find several publications developing this last method by using different software programs. In the present work, we used Excel for the Monte Carlo simulation for the calculus of the uncertainty associated to the different magnitudes derived from the field measurements following ISO 140-4, 140-5 and 140-7. We compare the results with the ones obtained by the uncertainty propagation method. Although both methods give similar values, some small differences have been observed. Some arguments to explain such differences are the asymmetry of the probability distributions associated to the entry magnitudes,the overestimation of the uncertainty following the GUM

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Impulse response measurements are carried out in laboratory facilities at Ecophon, Sweden, simulating a typical classroom with varying suspended ceilings and furniture arrangements. The aim of these measurements is to build a reliable database of acoustical parameters in order to have enough data to validate the new acoustical simulation tool which is under development at Danmarks Tekniske Universitet, Denmark. The different classroom configurations are also simulated using ODEON Room Acoustics software and are compared with the measurements. The resulting information is essential for the development of the acoustical simulation tool because it will enable the elimination of prediction errors, especially those below the Schroeder frequency. The surface impedance of the materials used during the experiments is measured in a Kundt’s tube at DTU, in order to characterize them as accurately as possible at the time of incorporation into the model. A brief study about porous materials frequently used in classrooms is presented. Wide diferences are found between methods of measuring absorption coefficients and local or extended assumptions. RESUMEN. Mediciones de Respuesta al Impulso son llevadas a cabo en las instalaciones con que cuenta la empresa Ecophon en su sede central de Hyllinge, Suecia. En una de sus salas, se recrean diferentes configuraciones típicas de aula, variando la altura y composición de los techos, colocando paneles absorbentes de pared e incluyendo diferentes elementos mobiliario como pupitres y sillas. Tres diferentes materiales absorbentes porosos de 15, 20 y 50 mm de espesor, son utilizados como techos suspendidos así como uno de 40 mm es utilizado en forma de paneles. Todas las medidas son realizadas de acuerdo al estándar ISO 3382, utilizando 12 combinaciones de fuente sonora y micrófono para cada configuración, así como respetando las distancias entre ellos establecidas en la norma. El objetivo de toda esta serie de medidas es crear una base de datos de parámetros acústicos tales como tiempo de reverberación, índice de claridad o índice de inteligibilidad medidos bajo diferentes configuraciones con el objeto de que éstos sirvan de referencia para la validación de una nueva herramienta de simulación acústica llamada PARISM que está siendo desarrollada en este momento en la Danmarks Tekniske Universitet de Copenhague. Esta herramienta tendrá en cuenta la fase, tanto en propagación como en reflexión, así como el comportamiento angulodependiente de los materiales y la difusión producida por las superficies. Las diferentes configuraciones de aula recreadas en Hyllinge, son simuladas también utilizando el software de simulación acústica ODEON con el fin de establecer comparaciones entre medidas y simulaciones para discutir la validez de estas ultimas. La información resultante es esencial para el desarrollo de la nueva herramienta de simulación, especialmente los resultados por debajo de la frecuencia de corte de Schroeder, donde ODEON no produce predicciones precisas debido a que no tiene en cuenta la fase ni en propagación ni en reflexión. La impedancia de superficie de los materiales utilizados en los experimentos, todos ellos fabricados por la propia empresa Ecophon, es medida utilizando un tubo de Kundt. De este modo, los coeficientes de absorción de incidencia aleatoria son calculados e incorporados a las simulaciones. Además, estos coeficientes también son estimados mediante el modelo empírico de Miki, con el fin de ser comparados con los obtenidos mediante otros métodos. Un breve estudio comparativo entre coeficientes de absorción obtenidos por diversos métodos y el efecto producido por los materiales absorbentes sobre los tiempos de reverberación es realizado. Grandes diferencias son encontradas, especialmente entre los métodos de tubo de impedancia y cámara reverberante. La elección de reacción local o extendida a la hora de estimar los coeficientes también produce grandes diferencias entre los resultados. Pese a que la opción de absorción angular es activada en todas las simulaciones realizadas con ODEON para todos los materiales, los resultados son mucho más imprecisos de lo esperado a la hora de compararlos con los valores extraidos de las medidas de Respuesta al Impulso. En salas como las recreadas, donde una superficie es mucho más absorbente que las demás, las ondas sonoras tienden a incidir en la superficie altamente absorbente desde ángulos de incidencia muy pequeños. En este rango de ángulos de incidencia, las absorciones que presentan los materiales absorbentes porosos estudiados son muy pequeñas, pese a que sus valores de coeficientes de absorción de incidencia aleatoria son altos. Dado que como descriptor de las superficies en ODEON se utiliza el coeficiente de absorción de incidencia aleatoria, los tiempos de reverberación son siempre subestimados en las simulaciones, incluso con la opción de absorción angular activada. Esto es debido a que el algoritmo que ejecuta esta opción, solo tiene en cuenta el tamaño y posición de las superficies, mientras que el comportamiento angulodependiente es diferente para cada material. Es importante destacar, que cuando la opción es activada, los tiempos simulados se asemejan más a los medidos, por lo tanto esta característica sí produce ciertas mejoras pese a no modelar la angulodependencia perfectamente. Por otra parte, ODEON tampoco tiene en cuenta el fenómeno de difracción, ni acepta longitudes de superficie menores de una longitud de onda a frecuencias medias (30 cm) por lo que en las configuraciones que incluyen absorbentes de pared, los cuales presentan un grosor de 4 cm que no puede ser modelado, los tiempos de reverberación son siempre sobreestimados. Para evitar esta sobreestimación, diferentes métodos de correción son analizados. Todas estas deficiencias encontradas en el software ODEON, resaltan la necesidad de desarrollar cuanto antes la herramienta de simulación acústica PARISM, la cual será capaz de predecir el comportamiento del campo sonoro de manera precisa en este tipo de salas, sin incrementar excesivamente el tiempo de cálculo. En cuanto a los parámetros extraidos de las mediciones de Respuesta al Impulso, bajo ninguna de las configuraciones recreadas los tiempos de reverberación cumplen con las condiciones establecidas por la regulación danesa en materia de edificación. Es importante destacar que los experimentos son llevados a cabo en un edificio construido para uso industrial, en el que, pese a contar con un buen aislamiento acústico, los niveles de ruido pueden ser superiores a los existentes dentro del edificio donde finalmente se ubique el aula. Además, aunque algunos elementos de mobiliario como pupitres y sillas son incluidos, en una configuración real de aula normalmente aparecerían algunos otros como taquillas, que no solo presentarían una mayor absorción, sino que también dispersarían las ondas incidentes produciendo un mejor funcionamiento del techo absorbente. Esto es debido a que las ondas incidirían en el techo desde una mayor variedad de ángulos, y no solo desde ángulos cercanos a la dirección paralela al techo, para los cuales los materiales presentan absorciones muy bajas o casi nulas. En relación a los otros parámetros como índice de claridad o índice de inteligibilidad extraidos de las medidas, no se han podido extraer conclusiones válidas dada la falta de regulación existente. Sin embargo, el efecto que produce sobre ellos la inclusión de techos, paneles de pared y mobiliario sí es analizada, concluyendo que, como era de esperar, los mejores resultados son obtenidos cuando todos los elementos están presentes en la sala en el mismo momento.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A methodology has been developed and presented to enable the use of small to medium scale acoustic hover facilities for the quantitative measurement of rotor impulsive noise. The methodology was applied to the University of Maryland Acoustic Chamber resulting in accurate measurements of High Speed Impulsive (HSI) noise for rotors running at tip Mach numbers between 0.65 and 0.85 – with accuracy increasing as the tip Mach number was increased. Several factors contributed to the success of this methodology including: • High Speed Impulsive (HSI) noise is characterized by very distinct pulses radiated from the rotor. The pulses radiate high frequency energy – but the energy is contained in short duration time pulses. • The first reflections from these pulses can be tracked (using ray theory) and, through adjustment of the microphone position and suitably applied acoustic treatment at the reflected surface, reduced to small levels. A computer code was developed that automates this process. The code also tracks first bounce reflection timing, making it possible to position the first bounce reflections outside of a measurement window. • Using a rotor with a small number of blades (preferably one) reduces the number of interfering first bounce reflections and generally improves the measured signal fidelity. The methodology will help the gathering of quantitative hovering rotor noise data in less than optimal acoustic facilities and thus enable basic rotorcraft research and rotor blade acoustic design.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The process of structural health monitoring (SHM) involves monitoring a structure over a period of time using appropriate sensors, extracting damage sensitive features from the measurements made by the sensors and analysing these features to determine the current state of the structure. Various techniques are available for structural health monitoring of structures and acoustic emission (AE) is one technique that is finding an increasing use. Acoustic emission waves are the stress waves generated by the mechanical deformation of materials. AE waves produced inside a structure can be recorded by means of sensors attached on the surface. Analysis of these recorded signals can locate and assess the extent of damage. This paper describes preliminary studies on the application of AE technique for health monitoring of bridge structures. Crack initiation or structural damage will result in wave propagation in solid and this can take place in various forms. Propagation of these waves is likely to be affected by the dimensions, surface properties and shape of the specimen. This, in turn, will affect source localization. Various laboratory test results will be presented on source localization, using pencil lead break tests. The results from the tests can be expected to aid in enhancement of knowledge of acoustic emission process and development of effective bridge structure diagnostics system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Managing the sustainability of urban infrastructure requires regular health monitoring of key infrastructure such as bridges. The process of structural health monitoring involves monitoring a structure over a period of time using appropriate sensors, extracting damage sensitive features from the measurements made by the sensors, and analysing these features to determine the current state of the structure. Various techniques are available for structural health monitoring of structures, and acoustic emission is one technique that is finding an increasing use in the monitoring of civil infrastructures such as bridges. Acoustic emission technique is based on the recording of stress waves generated by rapid release of energy inside a material, followed by analysis of recorded signals to locate and identify the source of emission and assess its severity. This chapter first provides a brief background of the acoustic emission technique and the process of source localization. Results from laboratory experiments conducted to explore several aspects of the source localization process are also presented. The findings from the study can be expected to enhance knowledge of the acoustic emission process, and to aid the development of effective bridge structure diagnostics systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The flood flow in urbanised areas constitutes a major hazard to the population and infrastructure as seen during the summer 2010-2011 floods in Queensland (Australia). Flood flows in urban environments have been studied relatively recently, although no study considered the impact of turbulence in the flow. During the 12-13 January 2011 flood of the Brisbane River, some turbulence measurements were conducted in an inundated urban environment in Gardens Point Road next to Brisbane's central business district (CBD) at relatively high frequency (50 Hz). The properties of the sediment flood deposits were characterised and the acoustic Doppler velocimeter unit was calibrated to obtain both instantaneous velocity components and suspended sediment concentration in the same sampling volume with the same temporal resolution. While the flow motion in Gardens Point Road was subcritical, the water elevations and velocities fluctuated with a distinctive period between 50 and 80 s. The low frequency fluctuations were linked with some local topographic effects: i.e, some local choke induced by an upstream constriction between stairwells caused some slow oscillations with a period close to the natural sloshing period of the car park. The instantaneous velocity data were analysed using a triple decomposition, and the same triple decomposition was applied to the water depth, velocity flux, suspended sediment concentration and suspended sediment flux data. The velocity fluctuation data showed a large energy component in the slow fluctuation range. For the first two tests at z = 0.35 m, the turbulence data suggested some isotropy. At z = 0.083 m, on the other hand, the findings indicated some flow anisotropy. The suspended sediment concentration (SSC) data presented a general trend with increasing SSC for decreasing water depth. During a test (T4), some long -period oscillations were observed with a period about 18 minutes. The cause of these oscillations remains unknown to the authors. The last test (T5) took place in very shallow waters and high suspended sediment concentrations. It is suggested that the flow in the car park was disconnected from the main channel. Overall the flow conditions at the sampling sites corresponded to a specific momentum between 0.2 to 0.4 m2 which would be near the upper end of the scale for safe evacuation of individuals in flooded areas. But the authors do not believe the evacuation of individuals in Gardens Point Road would have been safe because of the intense water surges and flow turbulence. More generally any criterion for safe evacuation solely based upon the flow velocity, water depth or specific momentum cannot account for the hazards caused by the flow turbulence, water depth fluctuations and water surges.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In natural waterways and estuaries, the understanding of turbulent mixing is critical to the knowledge of sediment transport, stormwater runoff during flood events, and release of nutrient-rich wastewater into ecosystems. In the present study, some field measurements were conducted in a small subtropical estuary with micro-tidal range and semi-diurnal tides during king tide conditions: i. e., the tidal range was the largest for both 2009 and 2010. The turbulent velocity measurements were performed continuously at high-frequency (50Hz) for 60 h. Two acoustic Doppler velocimeters (ADVs) were sampled simultaneously in the middle estuarine zone, and a third ADV was deployed in the upper estuary for 12 h only. The results provided an unique characterisation of the turbulence in both middle and upper estuarine zones under the king tide conditions. The present observations showed some marked differences between king tide and neap tide conditions. During the king tide conditions, the tidal forcing was the dominant water exchange and circulation mechanism in the estuary. In contrast, the long-term oscillations linked with internal and external resonance played a major role in the turbulent mixing during neap tides. The data set showed further that the upper estuarine zone was drastically less affected by the spring tide range: the flow motion remained slow, but the turbulent velocity data were affected by the propagation of a transient front during the very early flood tide motion at the sampling site. © 2012 Springer Science+Business Media B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In urbanised areas, the flood flows constitute a hazard to populations and infrastructure as illustrated during major floods in 2011. During the 2011 Brisbane River flood, some turbulent velocity data were collected using acoustic Doppler velocimetry in an inundated street. The field deployment showed some unusual features of flood flow in the urban environment. That is, the water elevations and velocities fluctuated with distinctive periods between 50 and 100 s linked with some local topographic effects. The instantaneous velocity data were analysed using a triple decomposition. The velocity fluctuations included a large energy component in the slow fluctuation range, while the turbulent motion components were much smaller. The suspended sediment data showed some significant longitudinal flux. Altogether the results highlighted that the triple decomposition approach originally developed for period flows is well suited to complicated flows in an inundated urban environment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. In isotropic materials, the speed of acoustic wave propagation is governed by the bulk modulus and density. For tendon, which is a structural composite of fluid and collagen, however, there is some anisotropy requiring an adjustment for Poisson's ratio. This paper explores these relationships using data collected, in vivo, on human Achilles tendon and then compares estimates of elastic modulus and hysteresis against published values from in vitro mechanical tests. Methods. Measurements using conventional B-model ultrasound imaging, inverse dynamics and acoustic transmission techniques were used to determine dimensions, loading conditions and longitudinal speed of sound in the Achilles tendon during a series of isometric plantar flexion exercises against body weight. Upper and lower bounds for speed of sound versus tensile stress in the tendon were then modelled and estimates of the elastic modulus and hysteresis of the Achilles tendon derived. Results. Axial speed of sound varied between 1850 and 2090 ms-1 with a non-linear, asymptotic dependency on the level of tensile stress (5-35 MPa) in the tendon. Estimates derived for the elastic modulus of the Achilles tendon ranged between 1-2 GPa. Hysteresis derived from models of the stress-strain relationship, ranged from 3-11%. Discussion. Estimates of elastic modulus agree closely with those previously reported from direct measurements obtained via mechanical tensile tests on major weight bearing tendons in vitro [1,2]. Hysteresis derived from models of the stress-strain relationship is consistent with direct measures from various mamalian tendon (7-10%) but is lower than previous estimates in human tendon (17-26%) [3]. This non-invasive method would appear suitable for monitoring changes in tendon properties during dynamic sporting activities.