975 resultados para ATRIAL-FIBRILLATION


Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: Experimental models have reported conflicting results regarding the role of dispersion of repolarization in promoting atrial fibrillation (AF). Repolarization alternans, a beat-to-beat alternation in action potential duration, enhances dispersion of repolarization when propagation velocity is involved. METHODS AND RESULTS: In this work, original electrophysiological parameters were analysed to study AF susceptibility in a chronic sheep model of pacing-induced AF. Two pacemakers were implanted, each with a single right atrial lead. Right atrial depolarization and repolarization waves were documented at 2-week intervals. A significant and gradual decrease in the propagation velocity at all pacing rates and in the right atrial effective refractory period (ERP) was observed during the weeks of burst pacing before sustained AF developed when compared with baseline conditions. Right atrial repolarization alternans was observed, but because of the development of 2/1 atrioventricular block with far-field ventricular interference, its threshold could not be precisely measured. Non-sustained AF was not observed at baseline, but appeared during the electrical remodelling in association with a decrease in both ERP and propagation velocity. CONCLUSION: We report here on the feasibility of measuring ERP, atrial repolarization alternans, and propagation velocity kinetics and their potential in predicting susceptibility to AF in a free-behaving model of pacing-induced AF using the standard pacemaker technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Atrial fibrillation (AF) is the most common arrhythmia and among the leading causes of stroke and heart failure in Western populations. Despite the increasing size of clinical trials assessing the efficacy and safety of AF therapies, achieved outcomes have not always matched expectations. Considering that AF is a symptom of many possible underlying diseases, clinical research for this arrhythmia should take into account their respective pathophysiology. Accordingly, the definition of the study populations to be included should rely on the established as well as on the new classifications of AF and take advantage from a differentiated look at the AF-electrocardiogram and from increasingly large spectrum of biomarkers. Such an integrated approach could bring researchers and treating physicians one step closer to the ultimate vision of personalized therapy, which, in this case, means an AF therapy based on refined diagnostic elements in accordance with scientific evidence gathered from clinical trials. By applying clear-cut patient inclusion criteria, future studies will be of smaller size and thus of lower cost. In addition, the findings from such studies will be of greater predictive value at the individual patient level, allowing for pinpointed therapeutic decisions in daily practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: While successful termination by pacing of organized atrial tachycardias has been observed in patients, single site rapid pacing has not yet led to conclusive results for the termination of atrial fibrillation (AF). The purpose of this study was to evaluate a novel atrial septal pacing algorithm for the termination of AF in a biophysical model of the human atria. METHODS AND RESULTS: Sustained AF was generated in a model based on human magnetic resonance images and membrane kinetics. Rapid pacing was applied from the septal area following a dual-stage scheme: (i) rapid pacing for 10-30 s at pacing intervals 62-70% of AF cycle length (AFCL), (ii) slow pacing for 1.5 s at 180% AFCL, initiated by a single stimulus at 130% AFCL. Atrial fibrillation termination success rates were computed. A mean success rate for AF termination of 10.2% was obtained for rapid septal pacing only. The addition of the slow pacing phase increased this rate to 20.2%. At an optimal pacing cycle length (64% AFCL) up to 29% of AF termination was observed. CONCLUSION: The proposed septal pacing algorithm could suppress AF reentries in a more robust way than classical single site rapid pacing. Experimental studies are now needed to determine whether similar termination mechanisms and rates can be observed in animals or humans, and in which types of AF this pacing strategy might be most effective.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multiple organization indices have been used to predict the outcome of stepwise catheter ablation in long-standing persistent atrial fibrillation (AF), however with limited success. Our study aims at developinginnovative organization indices from baseline ECG (i.e. during the procedure, before ablation) in orderto identify the site of AF termination by catheter ablation. Seventeen consecutive male patients (age60 ± 5 years, AF duration 7 ± 5 years) underwent a stepwise catheter ablation. Chest lead V6 was placedin the back (V6b). QRST cancelation was performed from chest leads V1 to V6b. Using an innovativeadaptive harmonic frequency tracking, two measures of AF organization were computed to quantify theharmonics components of ECG activity: (1) the adaptive phase difference variance (APD) between theAF harmonic components as a measure of AF regularity, and (2) and adaptive organization index (AOI)evaluating the cyclicity of the AF oscillations. Both adaptive indices were compared to indices computedusing a time-invariant approach: (1) ECG AF cycle length (AFCL), (2) the spectrum based organizationindex (OI), and (3) the time-invariant phase difference TIPD. Long-standing persistent AF was terminatedinto sinus rhythm or atrial tachycardia in 13/17 patients during stepwise ablation, 11 during left atriumablation (left terminated patients - LT), 2 during the right atrium ablation (right terminated patients -RT), and 4 were non terminated (NT) and required electrical cardioversion. Our findings showed that LTpatients were best separated from RT/NT before ablation by the duration of sustained AF and by AOI onchest lead V1 and APD from the dorsal lead V6b as compared to ECG AFCL, OI and TIPD, respectively. Ourresults suggest that adaptive measures of AF organization computed before ablation perform better thantime-invariant based indices for identifying patients whose AF will terminate during ablation within theleft atrium. These findings are indicative of a higher baseline organization in these patients that could beused to select candidates for the termination of AF by stepwise catheter ablation.© 2013 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rapport de synthèse « Faible prévalence de la fibrillation auriculaire chez des adultes asymptomatiques à Genève, Suisse » But : l'augmentation de la prévalence de la fibrillation auriculaire (FA) est dans les pays développés un problème de santé publique. L'ampleur de cette augmentation demeure cependant peu claire. L'objectif de ce travail est de déterminer la prévalence de la FA au sein d'un échantillon représentatif d'adultes asymptomatiques de plus de 50 ans. Méthode : entre janvier 2005 et décembre 2007, des individus résidants du canton de Genève et ayant déjà participé précédemment à une étude randomisée ont été invités pour un examen de contrôle. Le diagnostic de FA a été posé à l'aide d'un tracé électrocardiographique 6 pistes. Tous les tracés ont étés revus par un cardiologue. Les prévalences de FA ont ensuite été standardisées pour la distribution d'âge dans la population genevoise. Une prise de sang veineuse a été réalisée chez tous les participants après 8 heures de jeûne et la glycémie, la triglyceridémie, le cholestérol sérique total ainsi que le cholestérol HDL sérique ont été déterminés. Résultats : la participation a été de 72.8%. 29 cas de FA (22 hommes) ont été diagnostiqués parmi 3285 sujets (1696 hommes). La prévalence de la FA (95% Cl) était de 0.88% (0.86, 0.90). La prévalence standardisée pour l'âge était légèrement plus élevée [0.94% (0.91, 0.97), hommes: 1.23% (1.19, 1.27), femmes; 0.54% (0.47, 0.61)]. Les sujets avec une FA étaient plus âgés (72.1 vs. 63.1 ans, ρ < 0.0001), plus souvent de sexe masculin (75.9% vs. 50.4%, ρ = 0.0087), avaient un indice de masse corporelle plus élevé (27.9 vs. 25,9 kg/m2, ρ = 0.011), un périmètre abdominal plus important (98.8 vs. 90.2 cm, ρ = 0.0034), une tension artérielle diastolique plus élevée (80.9 vs. 75.7mmhg, ρ = 0.0093), un cholestérol sérique total plus bas (5.16 vs. 5.75mmol/L, ρ = 0.0019) et un HDL cholestérol sérique plus bas (1.31 vs. 1.48 mmol/L, ρ = 0.02). A l'anamnèse un antécédent « d'embolie artérielle » (cérébrale ou membres inférieurs) était significativement plus fréquent chez les sujets avec une FA (10.3 vs. 3.3%, ρ = 0.03). Conclusion : cette étude basée sur une population suisse asymptomatique montre une prévalence de la FA inférieure à 1%. Ces résultats sont moins alarmants que ceux obtenus lors de précédentes études.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose Multiple organization indices (OIs) have been used to predict the outcome of stepwise catheter ablation (step-CA) in long-standing persistent AF (pers-AF), however with limited success. Our study aims at developing innovative OIs from baseline (BL, before ablation) ECG in order to predict the outcome of step-CA. Methods Fourteen consecutive patients (pts) (60±5 y, AF duration 21±9 m) underwent a step-CA consisting in pulmonary veins isolation, left atrial (LA) defragmentation and linear ablations, and right atrial (RA) ablations if non terminated. Chest lead V6 was placed in the back (V6b). After QRST cancellation from chest leads V1 to V6b, two OIs were computed to quantify the harmonic components of ECG atrial activity: 1) phase difference variance (PD) between the AF harmonic components as a measure of AF regularity, and 2) adaptive OI (AOI) evaluating the time evolution of the AF harmonic components. Both indices were compared to classical ones: a spectrum-based OI (SOI) and ECG AF cycle length (AFCL). Results Pers-AF was terminated into sinus rhythm or atrial tachycardia in 10/14 pts during step-CA, 8 during LA (LT), 2 during RA (RT) ablation, and 4 were non terminated (NT). The figure shows that LT was best separated from RT/NT before ablation by AOI computed on lead V1 (A) and PD from lead V6b (B) as compared to SOI and AFCL respectively. Conclusion Our results suggest that adaptive OIs computed before ablation perform better than classical OIs for separating LT from RT/NT pts. These findings are indicative of a higher baseline organization in LT pts that could be used to select candidates for the restoration of sinus rhythm by step-CA.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intracardiac organization indices such as atrial fibrillation (AF) cycle length (AFCL) have been used to track the efficiency of stepwise catheter ablation (step-CA) of longstanding persistent AF, however with limited success. The morphology of AF activation waves reflects the underlying activation patterns. Its temporal evolution is a local organization indicator that could be potentially used for tracking the efficiency of step-CA. We report a new method for characterizing the structure of the temporal evolution of activation wave morphology. Using recurrence plots, novel organization indices are proposed. By computing their relative evolution during the first step of ablation vs baseline, we found that these new parameters are superior to AFCL to track the effect of step-CA "en route" to AF termination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chronic atrial fibrillation affects millions of people worldwide. Its surgical treatment often fails to restore the transport function of the atrium. This study first introduces the concept of an atrial assist device (AAD) to restore the pump function of the atrium. The AAD is developed to be totally implantable in the human body with a transcutaneous energy transfer system to recharge the implanted battery. The ADD consists of a motorless pump based on artificial muscle technology, positioned on the external surface of the atrium to compress it and restore its muscular activity. A bench model reproduces the function of a fibrillating atrium to assess the circulatory support that this pump can provide. Atripump (Nanopowers SA, Switzerland) is a dome-shaped silicone-coated nitinol actuator 5 mm high, sutured on the external surface of the atrium. A pacemaker-like control unit drives the actuator that compresses the atrium, providing the mechanical support to the blood circulation. Electrical characteristics: the system is composed of one actuator that needs a minimal tension of 15 V and has a maximum current of 1.5 A with a 50% duty cycle. The implantable rechargeable battery is made of a cell having the following specifications: nominal tension of a cell: 4.1 V, tension after 90% of discharge: 3.5 V, nominal capacity of a cell: 163 mA h. The bench model consists of an open circuit made of latex bladder 60 mm in diameter filled with water. The bladder is connected to a vertically positioned tube that is filled to different levels, reproducing changes in cardiac preload. The Atripump is placed on the outer surface of the bladder. Pressure, volume and temperature changes were recorded. The contraction rate was 1 Hz with a power supply of 12 V, 400 mA for 200 ms. Preload ranged from 15 to 21 cm H(2)O. Maximal silicone membrane temperature was 55 degrees C and maximal temperature of the liquid environment was 35 degrees C. The pump produced a maximal work of 16 x 10(-3) J. Maximal volume pumped was 492 ml min(-1). This artificial muscle pump is compact, follows the Starling law and reproduces the hemodynamic performances of a normal atrium. It could represent a new tool to restore the atrial kick in persistent atrial fibrillation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Atrial fibrillation (AF) is the most common cardiac arrhythmia. The risk of thromboembolic events is important, and at that time, there is no definite treatment for AF. Oral anticoagulation also represents a hemorrhagic risk factor. Ninety percent of atrial thrombi are located within the left atrial appendage. The percutaneous closure of this left atrial appendage with a device has been shown to decrease thromboembolic events even after interruption of oral anticoagulation as compared to warfarin in a recent randomized study. Recent data support this innovative technique as a reasonable alternative to long term anticoagulation in patients at high risk of bleeding.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

CONTEXT: A shortening of the atrial refractory period has been considered as the main mechanism for the increased risk of atrial fibrillation in hyperthyroidism. However, other important factors may be involved. OBJECTIVE: Our objective was to determine the activity of abnormal supraventricular electrical depolarizations in response to elevated thyroid hormones in patients without structural heart disease. PATIENTS AND DESIGN: Twenty-eight patients (25 females, three males, mean age 43+/-11 yr) with newly diagnosed and untreated hyperthyroidism were enrolled in a prospective trial after exclusion of heart disease. Patients were followed up for 16 +/- 6 months and studied at baseline and 6 months after normalization of serum TSH levels. MAIN OUTCOME MEASURES: The incidence of abnormal premature supraventricular depolarizations (SVPD) and the number of episodes of supraventricular tachycardia was defined as primary outcome measurements before the start of the study. In addition, heart rate oscillations (turbulence) after premature depolarizations and heart rate variability were compared at baseline and follow-up. RESULTS: SVPDs decreased from 59 +/- 29 to 21 +/- 8 per 24 h (P = 0.003), very early SVPDs (so called P on T) decreased from 36 +/- 24 to 3 +/- 1 per 24 h (P < 0.0001), respectively, and nonsustained supraventricular tachycardias decreased from 22 +/- 11 to 0.5 +/- 0.2 per 24 h (P = 0.01) after normalization of serum thyrotropin levels. The hyperthyroid phase was characterized by an increased heart rate (93 +/- 14 vs. 79 +/- 8 beats/min, P < 0.0001) and a decreased turbulence slope (3.6 vs. 9.2, P = 0.003), consistent with decreased vagal tone. This was confirmed by a significant decrease of heart rate variability. CONCLUSION: Hyperthyroidism is associated with an increased supraventricular ectopic activity in patients with normal hearts. The activation of these arrhythmogenic foci by elevated thyroid hormones may be an important causal link between hyperthyroidism and atrial fibrillation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: Surgical ablation procedures for treating atrial fibrillation have been shown to be highly successful. However, the ideal ablation pattern still remains to be determined. This article reports on a systematic study of the effectiveness of the performance of different ablation line patterns. METHODS AND RESULTS: This study of ablation line patterns was performed in a biophysical model of human atria by combining basic lines: (i) in the right atrium: isthmus line, line between vena cavae and appendage line and (ii) in the left atrium: several versions of pulmonary vein isolation, connection of pulmonary veins, isthmus line, and appendage line. Success rates and the presence of residual atrial flutter were documented. Basic patterns yielded conversion rates of only 10-25 and 10-55% in the right and the left atria, respectively. The best result for pulmonary vein isolation was obtained when a single closed line encompassed all veins (55%). Combination of lines in the right/left atrium only led to a success rate of 65/80%. Higher rates, up to 90-100%, could be obtained if right and left lines were combined. The inclusion of a left isthmus line was found to be essential for avoiding uncommon left atrial flutter. CONCLUSION: Some patterns studied achieved a high conversion rate, although using a smaller number of lines than those of the Maze III procedure. The biophysical atrial model is shown to be effective in the search for promising alternative ablation strategies.