987 resultados para ALVEOLAR PRESSURE MEASUREMENT
Resumo:
The use of a thermal buttocks manikin(1) was explored as a tool to standardize the evaluation of seat comfort. Thermal manikin buttocks were developed and calibrated thermally and anatomically to simulate the sensible heat transfer of a seated person and used to evaluate interface pressure distribution. In essence, the pressure maps of manikin buttocks with and without heating were compared to those of a seated person. The results of average pressure demonstrated that the thermal manikins have a better response in interface pressure measurement than manikins without heating.
Resumo:
This qualitative study was performed with 71 hypertensive patients, with the objectives to compare outpatient and home blood pressure monitoring (HBPM), to assess blood pressure control, and characterize white-coat hypertension. A nurse performed the outpatient blood pressure measurement. The home blood pressure monitoring was carried out over seven days. White-coat hypertension was quantified as a difference between the outpatient measurement and home blood pressure monitoring in the ranges from 1 to 5, 6 to 10 and > 10 mmHg. The outpatient blood pressure measurement was significantly higher (p<0.05) than the home blood pressure measurement. Pressure control corresponded to 9.9% in the outpatient measurement and 23.9% in the home blood pressure measurement. The white-coat effect > 10 mmHg was 57.7% for systolic and 32.4% for diastolic pressure, in the range from 6 to 10 mmHg. Home blood pressure measurement provided a better assessment of hypertensive patients' control.
Resumo:
BACKGROUND: Physiological data obtained with the pulmonary artery catheter (PAC) are susceptible to errors in measurement and interpretation. Little attention has been paid to the relevance of errors in hemodynamic measurements performed in the intensive care unit (ICU). The aim of this study was to assess the errors related to the technical aspects (zeroing and reference level) and actual measurement (curve interpretation) of the pulmonary artery occlusion pressure (PAOP). METHODS: Forty-seven participants in a special ICU training program and 22 ICU nurses were tested without pre-announcement. All participants had previously been exposed to the clinical use of the method. The first task was to set up a pressure measurement system for PAC (zeroing and reference level) and the second to measure the PAOP. RESULTS: The median difference from the reference mid-axillary zero level was - 3 cm (-8 to + 9 cm) for physicians and -1 cm (-5 to + 1 cm) for nurses. The median difference from the reference PAOP was 0 mmHg (-3 to 5 mmHg) for physicians and 1 mmHg (-1 to 15 mmHg) for nurses. When PAOP values were adjusted for the differences from the reference transducer level, the median differences from the reference PAOP values were 2 mmHg (-6 to 9 mmHg) for physicians and 2 mmHg (-6 to 16 mmHg) for nurses. CONCLUSIONS: Measurement of the PAOP is susceptible to substantial error as a result of practical mistakes. Comparison of results between ICUs or practitioners is therefore not possible.
Resumo:
The purpose of this single-center study was to report our initial experience with an implantable remote pressure sensor for aneurysm sac pressure measurement in patients post-endovascular aneurysm repair (EVAR) including short-term follow-up. A pressure sensor (EndoSure, Atlanta, GA) was implanted in 12 patients treated with different commercially available aortic endografts for EVAR. Pressure was read pre- and post-EVAR in the operating room. One-month follow-up (30 days +/- 6 days) was performed including sac pressure readings and IV contrast CT scans. Variables were compared using the paired Student's t test. An intraprocedure type-I endoleak and a type-III endoleak were successfully treated resulting in decreasing sac pressures. In all patients, post-EVAR systolic sac pressure decreased by an average of 33% (P = 0.005) compared to pre-EVAR measurements. One-month follow-up demonstrated a 47% decrease in systolic sac pressure (P = 0.05). On follow-up CT scans, the average maximum aneurysm diameter pre-EVAR was 6.3 +/- 1.6 cm and post-EVAR 6.0 +/- 1.7 cm (P=0.05). The diameter of the aneurysm sac was larger only in one patient with a type-III endoleak. Remote sac pressure measurement may provide important information in addition to imaging and may help to reduce the number of follow-up CT scans.
Resumo:
This thesis covers the correction, and verification, development, and implementation of a computational fluid dynamics (CFD) model for an orifice plate meter. Past results were corrected and further expanded on with compressibility effects of acoustic waves being taken into account. One dynamic pressure difference transducer measures the time-varying differential pressure across the orifice meter. A dynamic absolute pressure measurement is also taken at the inlet of the orifice meter, along with a suitable temperature measurement of the mean flow gas. Together these three measurements allow for an incompressible CFD simulation (using a well-tested and robust model) for the cross-section independent time-varying mass flow rate through the orifice meter. The mean value of this incompressible mass flow rate is then corrected to match the mean of the measured flow rate( obtained from a Coriolis meter located up stream of the orifice meter). Even with the mean and compressibility corrections, significant differences in the measured mass flow rates at two orifice meters in a common flow stream were observed. This means that the compressibility effects associated with pulsatile gas flows is significant in the measurement of the time-varying mass flow rate. Future work (with the approach and initial runs covered here) will provide an indirect verification of the reported mass flow rate measurements.
Resumo:
OBJECTIVE Little information is available on the early course of hypertension in type 1 diabetes. The aim of our study, therefore, was to document circadian blood pressure profiles in patients with a diabetes duration of up to 20 years and relate daytime and nighttime blood pressure to duration of diabetes, BMI, insulin therapy, and HbA1c. RESEARCH DESIGN AND METHODS Ambulatory profiles of 24-h blood pressure were recorded in 354 pediatric patients with type 1 diabetes (age 14.6 +/- 4.2 years, duration of diabetes 5.6 +/- 5.0 years, follow-up for up to 9 years). A total of 1,011 profiles were available for analysis from patients not receiving antihypertensive medication. RESULTS Although daytime mean systolic pressure was significantly elevated in diabetic subjects (+3.1 mmHg; P < 0.0001), daytime diastolic pressure was not different from from the height- and sex-adjusted normal range (+0.1 mmHg, NS). In contrast, both systolic and diastolic nighttime values were clearly elevated (+7.2 and +4.2 mmHg; P < 0.0001), and nocturnal dipping was reduced (P < 0.0001). Systolic blood pressure was related to overweight in all patients, while diastolic blood pressure was related to metabolic control in young adults. Blood pressure variability was significantly lower in girls compared with boys (P < 0.01). During follow-up, no increase of blood pressure was noted; however, diastolic nocturnal dipping decreased significantly (P < 0.03). Mean daytime blood pressure was significantly related to office blood pressure (r = +0.54 for systolic and r = +0.40 for diastolic pressure); however, hypertension was confirmed by ambulatory blood pressure measurement in only 32% of patients with elevated office blood pressure. CONCLUSIONS During the early course of type 1 diabetes, daytime blood pressure is higher compared with that of healthy control subjects. The elevation of nocturnal values is even more pronounced and nocturnal dipping is reduced. The frequency of white-coat hypertension is high among adolescents with diabetes, and ambulatory blood pressure monitoring avoids unnecessary antihypertensive treatment.
Resumo:
A simple analytical model for the train-induced flow and its effects on pedestrians is presented in this paper. The expressions developed for the induced air velocity and pressure on the pedestrian surface, as well as their dependence with time, are obtained from unsteady potential theory. The relevant parameters and their effects are analysed, in particular the sensitivity of the pressure coefficient and its rate of change on the train and pedestrian transverse size, the distance to the tracks and the pressure measurement location on the pedestrian surface. In spite of the extreme simplicity of the model and the expressions obtained, good correlation is observed with previously existing experiments. With this work, an absence of published studies concerning analytical approaches to the problem of vehicle-induced pressure on pedestrians is intended to be covered, allowing for simplified testing procedures.
Resumo:
The characterization of blood pressure in treatment trials assessing the benefits of blood pressure lowering regimens is a critical factor for the appropriate interpretation of study results. With numerous operators involved in the measurement of blood pressure in many thousands of patients being screened for entry into clinical trials, it is essential that operators follow pre-defined measurement protocols involving multiple measurements and standardized techniques. Blood pressure measurement protocols have been developed by international societies and emphasize the importance of appropriate choice of cuff size, identification of Korotkoff sounds, and digit preference. Training of operators and auditing of blood pressure measurement may assist in reducing the operator-related errors in measurement. This paper describes the quality control activities adopted for the screening stage of the 2nd Australian National Blood Pressure Study (ANBP2). ANBP2 is cardiovascular outcome trial of the treatment of hypertension in the elderly that was conducted entirely in general practices in Australia. A total of 54 288 subjects were screened; 3688 previously untreated subjects were identified as having blood pressure >140/90 mmHg at the initial screening visit, 898 (24%) were not eligible for study entry after two further visits due to the elevated reading not being sustained. For both systolic and diastolic blood pressure recording, observed digit preference fell within 7 percentage points of the expected frequency. Protocol adherence, in terms of the required minimum blood pressure difference between the last two successive recordings, was 99.8%. These data suggest that adherence to blood pressure recording protocols and elimination of digit preferences can be achieved through appropriate training programs and quality control activities in large multi-centre community-based trials in general practice. Repeated blood pressure measurement prior to initial diagnosis and study entry is essential to appropriately characterize hypertension in these elderly patients.
Resumo:
Central arterial waveforms and related indices of large artery properties can be determined with relative ease. This would make them an attractive adjunct in the risk stratification for cardiovascular disease. Although they have been associated with some classical risk factors and the presence of coronary disease, their prospective value in predicting cardiovascular outcomes is unknown. The present study determined the relative predictive value for cardiovascular disease-free survival of large artery properties as compared with noninvasive brachial blood pressure alone in a population of elderly female hypertensive subjects. We measured systemic arterial compliance, central systolic pressure, and carotid augmentation index in a subset of female participants in the Second Australian National Blood Pressure Study ( untreated blood pressure 169/88 +/- 12/ 8 mm Hg). There were a total of 53 defined events during a median of 4.1 years of follow-up in 484 women with complete measurements. Although baseline blood pressures at the brachial artery predicted cardiovascular disease-free survival ( hazard ratio [HR], 2.3; 95% CI, 1.3 to 4.1 for pulse pressure >= 81 versus < 81 mm Hg; P = 0.01), no such relation was found for carotid augmentation index ( HR, 0.80; 95% CI, 0.44 to 1.44; P value not significant) or systemic arterial compliance ( HR, 1.25; 95% CI, 0.72 to 2.16; P value not significant). Blood pressure, but not noninvasively measured central arterial waveforms, predict outcome in the older female hypertensive patient. Thus, blood pressure measurement alone is superior to measurement of arterial waveforms in predicting outcome in this group.
Resumo:
In order to report the outcome of a patient who developed compartment syndrome after South American rattlesnake (Crotalus durissus terrificus) envenomation, confirmed by subfascial pressure measurement and magnetic resonance imaging (MRI). A 63-year-old male was admitted 1 h after being bitten on the right elbow by a large snake, which was not brought for identification. Physical and laboratory features upon admission revealed two fang marks, local tense swelling, paresthesia, intense local pain, hypertension, coagulopathy, and CK = 1530 U/L (RV < 170 U/L). The case was initially treated with bothropic antivenom (80 mL, intravenously), with no improvement. Evolution within 13-14 h post-bite revealed generalized myalgia, muscle weakness, palpebral ptosis, and severe rhabdomyolysis (CK = 126,160 U/L) compatible with envenoming by C. d. terrificus. The patient was then treated with crotalic antivenom (200 mL, intravenously), fluid replacement, and urine alkalinization. Twenty-four-hour post-bite MRI showed marked muscular edema in the anterior compartment of the right forearm, with a high subfascial pressure (40 mmHg) being detected 1 h later. ELISA of a blood sample obtained upon admission, before antivenom infusion, revealed a high serum concentration of C. d. terrificus venom. No fasciotomy was performed and the patient was discharged seven days later without sequelae. Snakebite by C. d. terrificus with subfascial venom injection may lead to increased intracompartmental pressure.
Resumo:
Foram comparados dois métodos não-invasivos de medida da pressão arterial, o Doppler vascular e o oscilométrico, com o objetivo de estabelecer parâmetros que possam auxiliar no diagnóstico seguro da hipertensão arterial. Para tal, foram utilizados 45 cães, machos e fêmeas, distribuídos em três grupos de acordo com o peso, pequeno, médio e grande porte. Em cada animal, procedeu-se a mensuração por meio do Doppler vascular e, em seguida, do oscilométrico. Na obtenção da pressão arterial sistólica, não houve diferença entre os métodos nos três grupos de animais, porém, na obtenção da pressão arterial diastólica, houve diferença estatística entre o Doppler vascular e o oscilométrico nos grupos de animais de pequeno e médio porte. Pôde-se concluir que valores confiáveis de pressão sistólica podem ser obtidos tanto por meio do Doppler vascular quanto do oscilométrico. Os valores da pressão arterial diastólica obtidos pelos dois métodos não se correlacionam, principalmente nos animais de pequeno e médio porte.
Resumo:
The present study evaluated the effects of an intramuscular injection of Tityus serrulatus venom (TsV) (0.67 mu g/g) on lung mechanics and lung inflammation at 15, 30, 60 and 180 min after inoculation. TsV inoculation resulted in increased lung elastance when compared with the control group (p < 0.001): these values were significantly higher at 60 min than at 15 and 180 min (p < 0.05). Resistive pressure (Delta P(1)) values decreased significantly at 30, 60 and 180 min after TsV injection (p < 0.001). TsV inoculation resulted in increased lung inflammation, characterised by an increased density of mononuclear cells at 15, 30, 60 and 180 min after TsV injection when compared with the control group (p < 0.001). TsV inoculation also resulted in an increased pulmonary density of polymorphonuclear cells at 15, 30 and 60 min following injection when compared to the control group (p < 0.001). In conclusion, T serrulatus venom leads to acute lung injury, characterised by altered lung mechanics and increased pulmonary inflammation. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Purpose of review Swelling is inexorably linked to shock and resuscitation in trauma. In many forms, swelling complicates and interacts with traumatic injury to raise pressures in the abdomen, resulting in intraabdominal hypertension, which may overtly manifest as abdominal compartment syndrome (ACS) driving multiple organ failure. Despite renewed clinical interest in posttraumatic intraabdominal pressure, there remains a chiasm between knowledge of the risks and clinical interventions to mitigate them. This review provides a concise overview of definitions, risk factors, diagnosis and management using an illustrative trauma case. Recent findings Intraabdominal pressure commonly increases following trauma, wherein ACS may manifest earlier than generally appreciated and complicate other insults such as shock and hemorrhage. Contemporary resuscitation strategies may exacerbate intraabdominal hypertension, particularly massive crystalloid resuscitation. Although unproven, the recent transition to crystalloid restriction and high plasma resuscitation strategies may influence the prevalence of ACS. Nonetheless, aggressive intraabdominal pressure monitoring should be mandatory in the critically ill. Despite potential nonoperative options, decompressive laparotomy remains the only definitive but often morbid treatment. Summary ACS results from many dysfunctions acting in concert with each other in self-propagating vicious cycles. Starting with greater awareness, it is imperative that the growing knowledge should be translated into clinical practice.
Resumo:
Objective To evaluate the inter-rater reliability of the modified Oxford Grading Scale and the Peritron manometer. Design All participants were evaluated twice, first by one examiner and 30 days later by a second examiner. Measurements of vaginal squeeze pressure were compared with the results from the palpation test. Participants Nineteen women with a mean age of 23.7 years (range 21 to 28 years). Results Inter-rater reliability for vaginal palpation was fair (kappa = 0.33, 95% confidence interval 0.09 to 0.57). Using the Peritron manometer, the difference between examiners was less than 10 cmH(2)O in 11 of the 19 (58%) cases. The palpation test did not differentiate between weak, moderate, good and strong muscle contractions. This study found fair inter-rater reliability for the modified Oxford Grading Scale and moderate inter-rater reliability for the Peritron manometer. Conclusions The inter-rater reliability of vaginal squeeze pressure measurement using the Peritron manometer is acceptable and can be used in re-evaluations performed by different examiners in clinical practice. However, for research purposes, the ideal situation would be for a single examiner to assess and re-assess the subject. Vaginal palpation is important in the clinical assessment of correctness of a pelvic floor muscle contraction, but this study does not support the use of the modified Oxford Grading Scale as a reliable and valid method to measure and differentiate pelvic floor muscle strength. (C) 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Resumo:
Background: Ehrlichiosis is a multisystemic disease with the potential to cause cardiomyocyte injury in naturally infected dogs. Hypothesis: Myocardial injury occurs in dogs infected with Ehrlichia canis. Animals: One-hundred and ninety-four dogs from Brazil with clinical and laboratory abnormalities indicative of ehrlichiosis. Sixteen healthy dogs served as controls. Methods: Electrocardiogram, echocardiogram, noninvasive blood pressure measurement, and serum cardiac troponin I (cTnI) concentrations were evaluated. Serologic assays and PCR determined the exposure and infection status for E. canis, Anaplasma spp., Babesia canis vogeli, Bartonella spp., Borrelia burgdorferi, Dirofilaria immitis, Ehrlichia chaffeensis, Ehrlichia ewingii, Leishmania chagasi, and spotted-fever group Rickettsia. Dogs were assigned to groups according to PCR status: E. canis infected, infected with other vector-borne organisms, sick dogs lacking PCR evidence for infection, and healthy controls. Results: E. canis-infected dogs had higher serum cTnI concentrations than controls (median: 0.04 ng/dL; range 0.04-9.12 ng/dL; control median: 0.04 ng/dL; range: 0.04-0.10 ng/dL; P = .012), and acute E. canis infection was associated with myocardial injury (odds ratio [OR]: 2.67, confidence interval [CI] 95%: 1.12-6.40, P = .027). Severity of anemia was correlated with increased risk of cardiomyocyte damage (r = 0.84, P < .001). Dogs with clinical signs of systemic inflammatory response syndrome (SIRS) were at higher risk for myocardial injury than were other sick dogs (OR: 2.55, CI 95%: 1.31-4.95, P = .005). Conclusions and Clinical Importance: Acute infection with E. canis is a risk factor for myocardial injury in naturally infected Brazilian dogs. Severity of anemia and SIRS might contribute to the pathophysiology of myocardial damage.