Relevância:

100.00% 100.00%

Publicador:

Resumo:

An electronically tunable reflection polarizer which exploits the dielectric anisotropy of nematic liquid crystals (LC) has been designed, fabricated and measured in a frequency band centered at 130 GHz. The phase agile polarizing mirror converts an incident slant 45° signal upon reflection to right hand circular (RHCP), orthogonal linear (-45 °) or left hand circular (LHCP) polarization depending on the value of the voltage biasing the LC mixture. In the experimental set-up this is achieved by applying a low frequency bias voltage of 0 V, 40 V and 89 V respectively, across the cavity containing the LC material.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Detailed knowledge of fast electron energy transport following the interaction of ultrashort intense laser pulses is a key subject for fast ignition. This is a problem relevant to many areas of laser-plasma physics with particular importance to fast ignition and X-ray secondary source development, necessary for the development of large-scale facilities such as HiPER and ELI. Operating two orthogonal crystal spectrometers set at Bragg angles close to 45 degrees determines the X-ray s- and p-polarization ratio. From this ratio, it is possible to infer the velocity distribution function of the fast electron beam within the dense plasma. We report on results of polarization measurements at high density for sulphur and nickel buried layer targets in the high intensity range of 10(19) - 10(21) Wcm(-2). We observe at 45 degrees the Ly-alpha doublet using two sets of orthogonal highly-orientated pyrolytic graphite (HOPG) crystals set in 1(st) order for sulphur and 3(rd) order for nickel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lasers play an important role for medical, sensoric and data storage devices. This thesis is focused on design, technology development, fabrication and characterization of hybrid ultraviolet Vertical-Cavity Surface-Emitting Lasers (UV VCSEL) with organic laser-active material and inorganic distributed Bragg reflectors (DBR). Multilayer structures with different layer thicknesses, refractive indices and absorption coefficients of the inorganic materials were studied using theoretical model calculations. During the simulations the structure parameters such as materials and thicknesses have been varied. This procedure was repeated several times during the design optimization process including also the feedback from technology and characterization. Two types of VCSEL devices were investigated. The first is an index coupled structure consisting of bottom and top DBR dielectric mirrors. In the space in between them is the cavity, which includes active region and defines the spectral gain profile. In this configuration the maximum electrical field is concentrated in the cavity and can destroy the chemical structure of the active material. The second type of laser is a so called complex coupled VCSEL. In this structure the active material is placed not only in the cavity but also in parts of the DBR structure. The simulations show that such a distribution of the active material reduces the required pumping power for reaching lasing threshold. High efficiency is achieved by substituting the dielectric material with high refractive index for the periods closer to the cavity. The inorganic materials for the DBR mirrors have been deposited by Plasma- Enhanced Chemical Vapor Deposition (PECVD) and Dual Ion Beam Sputtering (DIBS) machines. Extended optimizations of the technological processes have been performed. All the processes are carried out in a clean room Class 1 and Class 10000. The optical properties and the thicknesses of the layers are measured in-situ by spectroscopic ellipsometry and spectroscopic reflectometry. The surface roughness is analyzed by atomic force microscopy (AFM) and images of the devices are taken with scanning electron microscope (SEM). The silicon dioxide (SiO2) and silicon nitride (Si3N4) layers deposited by the PECVD machine show defects of the material structure and have higher absorption in the ultra violet range compared to ion beam deposition (IBD). This results in low reflectivity of the DBR mirrors and also reduces the optical properties of the VCSEL devices. However PECVD has the advantage that the stress in the layers can be tuned and compensated, in contrast to IBD at the moment. A sputtering machine Ionsys 1000 produced by Roth&Rau company, is used for the deposition of silicon dioxide (SiO2), silicon nitride (Si3N4), aluminum oxide (Al2O3) and zirconium dioxide (ZrO2). The chamber is equipped with main (sputter) and assisted ion sources. The dielectric materials were optimized by introducing additional oxygen and nitrogen into the chamber. DBR mirrors with different material combinations were deposited. The measured optical properties of the fabricated multilayer structures show an excellent agreement with the results of theoretical model calculations. The layers deposited by puttering show high compressive stress. As an active region a novel organic material with spiro-linked molecules is used. Two different materials have been evaporated by utilizing a dye evaporation machine in the clean room of the department Makromolekulare Chemie und Molekulare Materialien (mmCmm). The Spiro-Octopus-1 organic material has a maximum emission at the wavelength λemission = 395 nm and the Spiro-Pphenal has a maximum emission at the wavelength λemission = 418 nm. Both of them have high refractive index and can be combined with low refractive index materials like silicon dioxide (SiO2). The sputtering method shows excellent optical quality of the deposited materials and high reflection of the multilayer structures. The bottom DBR mirrors for all VCSEL devices were deposited by the DIBS machine, whereas the top DBR mirror deposited either by PECVD or by combination of PECVD and DIBS. The fabricated VCSEL structures were optically pumped by nitrogen laser at wavelength λpumping = 337 nm. The emission was measured by spectrometer. A radiation of the VCSEL structure at wavelength 392 nm and 420 nm is observed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In seed storage research, moisture content can be maintained by providing a stable relative humidity (e.g. over saturated salt solutions) or by hermetic storage, but the two approaches provide different gaseous environments which might affect longevity. Seeds of timothy (Phleum pratense L.) and sesame (Sesamum indicum L.) were stored at 45 degrees C or 50 degrees C, respectively, with different moisture contents maintained by hermetic storage in laminated-aluminium-foil packets, or by desiccators above either saturated salt solutions or moistened silica gel. Seeds were withdrawn from storage at intervals from 1 to 28 d for up to 480 d and viability estimated. Within a species, the negative logarithmic relation between seed longevity and moisture content did not differ (P> 0.25, timothy; >0.05, sesame) between storage in desiccators over either moistened silica gel or saturated salt solutions, whereas the relation was much steeper (P< 0.005) in hermetic storage: longevity was similar at high moisture contents, but at low values much greater with hermetic storage. This effect of storage method on seed longevity's sensitivity to moisture content implies that oxygen is relatively more deleterious to seeds at lower than at greater moisture contents and confirms that hermetic storage is preferable for long-term seed storage at low moisture contents.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Previous assessment methods for PG recognition used sensor mechanisms for PG that may cause discomfort. In order to avoid stress of applying wearable sensors, computer vision (CV) based diagnostic systems for PG recognition have been proposed. Main constraints in these methods are the laboratory setup procedures: Novel colored dresses for the patients were specifically designed to segment the test body from a specific colored background. Objective: To develop an image processing tool for home-assessment of Parkinson Gait(PG) by analyzing motion cues extracted during the gait cycles. Methods: The system is based on the idea that a normal body attains equilibrium during the gait by aligning the body posture with the axis of gravity. Due to the rigidity in muscular tone, persons with PD fail to align their bodies with the axis of gravity. The leaned posture of PD patients appears to fall forward. Whereas a normal posture exhibits a constant erect posture throughout the gait. Patients with PD walk with shortened stride angle (less than 15 degrees on average) with high variability in the stride frequency. Whereas a normal gait exhibits a constant stride frequency with an average stride angle of 45 degrees. In order to analyze PG, levodopa-responsive patients and normal controls were videotaped with several gait cycles. First, the test body is segmented in each frame of the gait video based on the pixel contrast from the background to form a silhouette. Next, the center of gravity of this silhouette is calculated. This silhouette is further skeletonized from the video frames to extract the motion cues. Two motion cues were stride frequency based on the cyclic leg motion and the lean frequency based on the angle between the leaned torso tangent and the axis of gravity. The differences in the peaks in stride and lean frequencies between PG and normal gait are calculated using Cosine Similarity measurements. Results: High cosine dissimilarity was observed in the stride and lean frequencies between PG and normal gait. High variations are found in the stride intervals of PG whereas constant stride intervals are found in the normal gait. Conclusions: We propose an algorithm as a source to eliminate laboratory constraints and discomfort during PG analysis. Installing this tool in a home computer with a webcam allows assessment of gait in the home environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work aimed to study the reproduction and description of technique for digital sampling images during rats gait and determination of the sciatic functional index (SFI), through a glass walkway to obtain shoots with a digital camera. After controlled injury by strangulation of sciatic nerve, with 3mm of length, during 30 seconds, using hemostatic forceps, a group of 32 rats was performed 24 hours before the lesion which served as control and 24 hours, 7, 14 and 21 days after injury. The tests consisted in the filming and shooting each animal in order to observe the view from below (by a mirror to 45 degrees) and subsequently analyzed using the IMAGE-J program. Measures were taken from the lengths of the legs (right and left), and the distance between the ankle. In the analysis of IFC, values close to zero (0) suggest that the function of the sciatic nerve is still preserved and values coming from "less one hundred" (-100) indicate total loss of function. It was verified in this study that 24 hours before surgery the average SFI was -7.07 +/- 7.88 and 24 hours after injury these values rose to an average of -77.95 +/- 13.81, being about 10 times larger, where 78% of the animals showed 60 to 100% of functional loss in motor activity, demonstrated by the gradual recovery over the days analyzed, confirming the accuracy and effectiveness of the proposed methodology. These results suggest that studies can be conducted to simplify and reduce costs using the technique for digital images of footprints during rats gait in the laboratory.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To characterize patients according to gender, age category, internment time, diagnostical hypothesis and location of the pressure ulcer; to identify the susceptibility conditions, intrinsical and extrinsical factors present on ICU patients and to verify on the existence of association between the susceptibility conditions and the intrinsecal and extrinsecal factors on the occurrence of PU. Methods: It is a descriptive study, of longitudinal design of the panel type, with quantitative approach, performed on two ICU s of a private hospital located in Natal/RN, with 40 patients interned at these units. The data collection was performed on all three shifts through a structured observation and physical exam of the patients' skin form seeking to identify the presence of PU. Results: The greatest occurence of PU was on individuals of the male gender (70%) when compared to the female gender (30%), that difference being statistically significant (p=0,0267), with the male gender presenting 4,3 times greater chance of developing PU than the female; the predominant age category was from 60 years of age on (85%), 60,0% presented 1 to 2 PU s after 7 (seven) days of permanence in the ICU s, the predominant diagnostical hypothesis on the patients with PU were the respiratory diseases (42,3%) and the most frequent locations of PU were the sacral region (40,0%) and heels (36,0%). 25 PU s of stage I were diagnosed on 50,0% of the followed patients, with general incidence of 50,0% on both ICUs. from the 88 variables researched, 75 were identified on the patients from the study, being the predominant conditions (anemia, hypotension, leukocytosis, other diseases hypertension blood pressure, cardiac insuffience, pneumonia - and ansiolythic), the intrinsecal factors (diminished muscular strenght and/or mass, discrete edema, totally compromised mobile coordination and total inability for movement on the bed) and the extrinsecal factors (inadequate mattress type, permanence on a single position for >2 hours, shearing/friction force, bed clothes with folds that leave marks on the body, pressure force) predominated on patients with PU. The male gender variables (p=0,0267,OR=4,3), sedation (p=0,0006,OR=4,1), psychomotive agitation (p=0,0375,OR=5,8) and leukocytosis (p=0,0285,OR=5,0) presented a significant statistical diference when analyzed independently. We verified an association of 17,3%, statistically significant (p=0,0384), between the susceptibility conditions (anemia, leukocytosis and hypotension), the intrinsecal factors (age equal or above 60 years, diminished/absent pain sensibility and smooth, fine or delicate skin) and the extrinsecal factors (inadequate mattress, pressure forces, shearing/friction force, permanence on a single position for more than 2 hours, elevation between 30 to 45 degrees and inadequate bed clothes' conditions), with a chance ratio of 4,6 times the risk of occurrence of PU on the patients that presented the referred association. Conclusion: The incidence of PU detected on the ICU-interned patients was high and we made evident the existence of association between the susceptibility conditions, the intrinsecal and extrinsecal factors on the occurrence of PU s on the ICUinterned patients, and thus we accept the alternative hypothesis proposed on the study

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Silicon carbide (SiC) has been employed in many different fields such as ballistic armor, thermal coating, high performance mirror substrate, semiconductors devices, among other things. Plasma application over the silicon carbide ceramics is relatively recent and it is able to promote relevant superficial modifications. Plasma expander was used in this work which was supplied by nitrogen and switched by a capacitor bank. Nitrogen plasma was applied over ceramic samples for 20 minutes, in a total medium of 1440 plasma pulses. SiC ceramics were produced by uniaxial pressing method (40 MPa) associated to isostatic pressing (300 MPa) and sintered at 1950 degrees C under argon gas atmosphere. Silicon carbide (beta-sic - BF-12) supplied by HC-Starck and sintering additive (7.6% YAG - Yttrium Aluminum Garnet) were used in order to obtain the ceramics. Before and after the plasma application, the samples were characterized by SEM, AFM, contact angle and surface energy measurement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of high vigor seed constitutes basic and fundamental. Given the increasing development os the seeds industry and the improvement of vigor tests used to differentiate subtle variations in the quality of seeds of vegetable crops, is needed. The objective was to study variations in conducting the accelerated aging test, to verify their sensitivity for identifying different vigor levels of arugula seed. Were used the cultivars Cultivada and Gigante, using five lots of seeds for each. The seeds were subjected to the determination of water content, germination, first germination, emergence of seedlings and variations in the accelerated aging test, without salt solution ( traditional procedure) and with salt solution in 48, 72 and 96 hours; at 38 degrees C, 41 degrees C and 45 degrees C. The accelerated aging test in traditional procedure is not efficient to evaluation the vigor of arugula seeds. The accelerated aging test with saline solution using the combination 41 degrees C for 72 hours, was sensitive to evaluated of the physiological potential of arugula seeds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to obtain cellulases that improve the detergency of laundry detergent products, two alkalophilic microorganims, Bacillus sp B38-2 and Streptomyces sp S36-2, were isolated from soil and compost by incubating samples in enrichment culture medium containing CMC and Na2CO3 at pH9.6. It was found that they secrete a constitutive extracellular alkaline carboxymethyl cellulase (CMCase) in high quantity. The maximum enzyme activity was observed between 48hr to 72 hr at 30-degrees-C for the Streptomyces and between 72hr to 96hr at 35-degrees-C for the Bacillus. The optimum pH and temperature of the crude enzyme activities ranged from 6.0 to 7.0 at 55-degrees-C for the Streptomyces and 7.0 to 8.0 at 60-degrees-C for the Bacillus. Two crude CMCases activities were termostable at 45-degrees-C for 1hr and the both crude enzyme activities of the Bacillus as of the Streptomyces were stable at pH 5.0 to 9.0 after pH treatments in various buffer solutions at 30-degrees-C for 24hr.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rhizopus microsporus var. rhizopodiformis produced high levels of alpha-amylase and glucoamylase under solid state fermentation, with several agricultural residues, such as wheat bran, cassava flour, sugar cane bagasse, rice straw, corncob and crushed corncob as carbon sources. These materials were humidified with distilled water, tap water, or saline solutions-Segato Rizzatti (SR), Khanna or Vogel. The best substrate for amylase production was wheat bran with SR saline solution (1:2 v/v). Amylolytic activity was still improved (14.3%) with a mixture of wheat bran, corncob, starch and SR saline solution (1:1:0.3:4.6 w/w/w/v). The optimized culture conditions were initial pH 5, at 45 degrees C during 6 days and relative humidity around 76%. The crude extract exhibited temperature and pH optima around 65 degrees C and 4-5, respectively. Amylase activity was fully stable for 1 h at temperatures up to 75 degrees C, and at pH values between 2.5 and 7.5.