980 resultados para 3D scalar data


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Pampo oil field is located in the southwest of the trend Badejo-Linguado-Pampo in an accumulation of single - mixed trap: structural-stratigraphic-diagenetic. Its main reservoir is a coquina shell of bivalves (the lowest) in the Lagoa Feia Group. During the rift phase, the Badejo-Linguado-Pampo trend´s accumulations evolve according to three tectono-stratigraphic cycles. The first two cycles are formed by siliciclastic rocks with fining up sequences and carbonates coquinas bivalves. The youngest cycle related to Alagoas age is a transgressive event represented by the presence of an evaporitic layer in the top (anhydrite). This study aims to characterize the reservoir Coqueiros Formation based on the analysis of 2D and 3D seismic data and well data-correlation profiles. The structural map of the top of coquinas reservoir indicates a curvilinear contour of Pampo Fault as described on the literature. This fault was interpreted on seismic data as a basement´s high, and it doesn´t show influence on the horizons above the top of Lagoa Feia Group. The Pampo fault is responsible for the division of the field into two blocks: the hanginwall in the West and the footwall to the East. This division is well marked on the reservoir´s isopach map where a greater thickness of reservoir is observed on the lower block. In the Southeast extreme of Badejo-Linguado-Pampo trend, on Pampo Field, the thick siliciclastic´s interval ends laterally to the basement, and its lower´s cycle forms a wedge, as consequence the carbonate-coquina overlaps directly the basement. Another implication of the higher and distal position of Pampo field is that the third cycle is absent, truncated by the unconformity pre-Macaé Group (Albian)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the region of Badejo oil Ffeld (Campos Basin) lies an Lower Albian dolomitic layer that shows reservoir rock and seal conditions, among others and, it is occasionally karstified. This work applies geostatistical techniques of ordinary and indicatior kriging, in an attempt to determine a method that assists the analysis of different scenarios offered for petroleum drilling from a quantitative point of view this fact is justified, because there are different visions and strategies that would be adopted under different dolomite conditions (stable - low porosity and high density; reservoir - high porosity and medium density; instable - high porosity and low dentisty). The main objective is a methodological introduction that has not been tested in dolomites before aiming to characterize the distribution of the three conditions described above by ordinary and indicatior kriging, which was based on the obtained data from the dolomite layer identification through well logs interpretation and correlation, followed by seismic interpretation. In addition, it was generated structural contour maps, based on 2D and 3D seismic data interpretation, and then, seismic attributes maps were calculated, in order to transform them into pseudo-density maps, i.e., maps that correlate the density values with the attribute values. As primary results, structural contour maps and seismic attributes were obtained and ordinary and indicatior kriging maps were done, on which it is possible to interpret the distribution of the main reservoir and risk probability for drilling of exploration wells obtaining trends N35E and N10W direction for areas of stability or reservoir levels, while the central part of the map presents a higher risk for loss of drilling fluid. The cut-off values levels were based on the values of first and third quartiles of cumulative histogram (instable and stable zones, respectively), as well as the reservoir level was set as the interval...

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The integration of CMOS cameras with embedded processors and wireless communication devices has enabled the development of distributed wireless vision systems. Wireless Vision Sensor Networks (WVSNs), which consist of wirelessly connected embedded systems with vision and sensing capabilities, provide wide variety of application areas that have not been possible to realize with the wall-powered vision systems with wired links or scalar-data based wireless sensor networks. In this paper, the design of a middleware for a wireless vision sensor node is presented for the realization of WVSNs. The implemented wireless vision sensor node is tested through a simple vision application to study and analyze its capabilities, and determine the challenges in distributed vision applications through a wireless network of low-power embedded devices. The results of this paper highlight the practical concerns for the development of efficient image processing and communication solutions for WVSNs and emphasize the need for cross-layer solutions that unify these two so-far-independent research areas.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Analyzing and modeling relationships between the structure of chemical compounds, their physico-chemical properties, and biological or toxic effects in chemical datasets is a challenging task for scientific researchers in the field of cheminformatics. Therefore, (Q)SAR model validation is essential to ensure future model predictivity on unseen compounds. Proper validation is also one of the requirements of regulatory authorities in order to approve its use in real-world scenarios as an alternative testing method. However, at the same time, the question of how to validate a (Q)SAR model is still under discussion. In this work, we empirically compare a k-fold cross-validation with external test set validation. The introduced workflow allows to apply the built and validated models to large amounts of unseen data, and to compare the performance of the different validation approaches. Our experimental results indicate that cross-validation produces (Q)SAR models with higher predictivity than external test set validation and reduces the variance of the results. Statistical validation is important to evaluate the performance of (Q)SAR models, but does not support the user in better understanding the properties of the model or the underlying correlations. We present the 3D molecular viewer CheS-Mapper (Chemical Space Mapper) that arranges compounds in 3D space, such that their spatial proximity reflects their similarity. The user can indirectly determine similarity, by selecting which features to employ in the process. The tool can use and calculate different kinds of features, like structural fragments as well as quantitative chemical descriptors. Comprehensive functionalities including clustering, alignment of compounds according to their 3D structure, and feature highlighting aid the chemist to better understand patterns and regularities and relate the observations to established scientific knowledge. Even though visualization tools for analyzing (Q)SAR information in small molecule datasets exist, integrated visualization methods that allows for the investigation of model validation results are still lacking. We propose visual validation, as an approach for the graphical inspection of (Q)SAR model validation results. New functionalities in CheS-Mapper 2.0 facilitate the analysis of (Q)SAR information and allow the visual validation of (Q)SAR models. The tool enables the comparison of model predictions to the actual activity in feature space. Our approach reveals if the endpoint is modeled too specific or too generic and highlights common properties of misclassified compounds. Moreover, the researcher can use CheS-Mapper to inspect how the (Q)SAR model predicts activity cliffs. The CheS-Mapper software is freely available at http://ches-mapper.org.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Navigated ultrasound (US) imaging is used for the intra-operative acquisition of 3D image data during imageguided surgery. The presented approach includes the design of a compact and easy to use US calibration device and its integration into a software application for navigated liver surgery. User interaction during the calibration process is minimized through automatic detection of the calibration process followed by automatic image segmentation, calculation of the calibration transform and validation of the obtained result. This leads to a fast, interaction-free and fully automatic calibration procedure enabling intra-operative

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Postmortem minimal invasive angiography has already been implemented to support virtual autopsy examinations. An experimental approach in a porcine model to overcome an initially described artificial tissue edema artifact by using a poly ethylene glycol (PEG) containing contrast agent solution showed promising results. The present publication describes the first application of PEG in a whole corpse angiographic CT examination. A minimal invasive postmortem CT angiography was performed in a human corpse utilizing the high viscosity contrast agent solution containing 65% of PEG. Injection was carried out via the femoral artery into the aortic root in simulated cardiac output conditions. Subsequent CT scanning delivered the 3D volume data of the whole corpse. Visualization of the human arterial anatomy was excellent and the contrast agent distribution was generally limited to the arterial system as intended. As exceptions an enhancement of the brain, the left ventricular myocardium and the renal cortex became obvious. This most likely represented the stage of centralization of the blood circulation at the time of death with dilatation of the precapillary arterioles within these tissues. Especially for the brain this resulted in a distinctively improved visualization of the intracerebral structures by CT. However, the general tissue edema artifact of postmortem minimal invasive angiography examinations could be distinctively reduced.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: A fully three-dimensional (3D) massively parallelizable list-mode ordered-subsets expectation-maximization (LM-OSEM) reconstruction algorithm has been developed for high-resolution PET cameras. System response probabilities are calculated online from a set of parameters derived from Monte Carlo simulations. The shape of a system response for a given line of response (LOR) has been shown to be asymmetrical around the LOR. This work has been focused on the development of efficient region-search techniques to sample the system response probabilities, which are suitable for asymmetric kernel models, including elliptical Gaussian models that allow for high accuracy and high parallelization efficiency. The novel region-search scheme using variable kernel models is applied in the proposed PET reconstruction algorithm. Methods: A novel region-search technique has been used to sample the probability density function in correspondence with a small dynamic subset of the field of view that constitutes the region of response (ROR). The ROR is identified around the LOR by searching for any voxel within a dynamically calculated contour. The contour condition is currently defined as a fixed threshold over the posterior probability, and arbitrary kernel models can be applied using a numerical approach. The processing of the LORs is distributed in batches among the available computing devices, then, individual LORs are processed within different processing units. In this way, both multicore and multiple many-core processing units can be efficiently exploited. Tests have been conducted with probability models that take into account the noncolinearity, positron range, and crystal penetration effects, that produced tubes of response with varying elliptical sections whose axes were a function of the crystal's thickness and angle of incidence of the given LOR. The algorithm treats the probability model as a 3D scalar field defined within a reference system aligned with the ideal LOR. Results: This new technique provides superior image quality in terms of signal-to-noise ratio as compared with the histogram-mode method based on precomputed system matrices available for a commercial small animal scanner. Reconstruction times can be kept low with the use of multicore, many-core architectures, including multiple graphic processing units. Conclusions: A highly parallelizable LM reconstruction method has been proposed based on Monte Carlo simulations and new parallelization techniques aimed at improving the reconstruction speed and the image signal-to-noise of a given OSEM algorithm. The method has been validated using simulated and real phantoms. A special advantage of the new method is the possibility of defining dynamically the cut-off threshold over the calculated probabilities thus allowing for a direct control on the trade-off between speed and quality during the reconstruction.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La embriogénesis es el proceso mediante el cual una célula se convierte en un ser un vivo. A lo largo de diferentes etapas de desarrollo, la población de células va proliferando a la vez que el embrión va tomando forma y se configura. Esto es posible gracias a la acción de varios procesos genéticos, bioquímicos y mecánicos que interaccionan y se regulan entre ellos formando un sistema complejo que se organiza a diferentes escalas espaciales y temporales. Este proceso ocurre de manera robusta y reproducible, pero también con cierta variabilidad que permite la diversidad de individuos de una misma especie. La aparición de la microscopía de fluorescencia, posible gracias a proteínas fluorescentes que pueden ser adheridas a las cadenas de expresión de las células, y los avances en la física óptica de los microscopios han permitido observar este proceso de embriogénesis in-vivo y generar secuencias de imágenes tridimensionales de alta resolución espacio-temporal. Estas imágenes permiten el estudio de los procesos de desarrollo embrionario con técnicas de análisis de imagen y de datos, reconstruyendo dichos procesos para crear la representación de un embrión digital. Una de las más actuales problemáticas en este campo es entender los procesos mecánicos, de manera aislada y en interacción con otros factores como la expresión genética, para que el embrión se desarrolle. Debido a la complejidad de estos procesos, estos problemas se afrontan mediante diferentes técnicas y escalas específicas donde, a través de experimentos, pueden hacerse y confrontarse hipótesis, obteniendo conclusiones sobre el funcionamiento de los mecanismos estudiados. Esta tesis doctoral se ha enfocado sobre esta problemática intentando mejorar las metodologías del estado del arte y con un objetivo específico: estudiar patrones de deformación que emergen del movimiento organizado de las células durante diferentes estados del desarrollo del embrión, de manera global o en tejidos concretos. Estudios se han centrado en la mecánica en relación con procesos de señalización o interacciones a nivel celular o de tejido. En este trabajo, se propone un esquema para generalizar el estudio del movimiento y las interacciones mecánicas que se desprenden del mismo a diferentes escalas espaciales y temporales. Esto permitiría no sólo estudios locales, si no estudios sistemáticos de las escalas de interacción mecánica dentro de un embrión. Por tanto, el esquema propuesto obvia las causas de generación de movimiento (fuerzas) y se centra en la cuantificación de la cinemática (deformación y esfuerzos) a partir de imágenes de forma no invasiva. Hoy en día las dificultades experimentales y metodológicas y la complejidad de los sistemas biológicos impiden una descripción mecánica completa de manera sistemática. Sin embargo, patrones de deformación muestran el resultado de diferentes factores mecánicos en interacción con otros elementos dando lugar a una organización mecánica, necesaria para el desarrollo, que puede ser cuantificado a partir de la metodología propuesta en esta tesis. La metodología asume un medio continuo descrito de forma Lagrangiana (en función de las trayectorias de puntos materiales que se mueven en el sistema en lugar de puntos espaciales) de la dinámica del movimiento, estimado a partir de las imágenes mediante métodos de seguimiento de células o de técnicas de registro de imagen. Gracias a este esquema es posible describir la deformación instantánea y acumulada respecto a un estado inicial para cualquier dominio del embrión. La aplicación de esta metodología a imágenes 3D + t del pez zebra sirvió para desvelar estructuras mecánicas que tienden a estabilizarse a lo largo del tiempo en dicho embrión, y que se organizan a una escala semejante al del mapa de diferenciación celular y con indicios de correlación con patrones de expresión genética. También se aplicó la metodología al estudio del tejido amnioserosa de la Drosophila (mosca de la fruta) durante el cierre dorsal, obteniendo indicios de un acoplamiento entre escalas subcelulares, celulares y supracelulares, que genera patrones complejos en respuesta a la fuerza generada por los esqueletos de acto-myosina. En definitiva, esta tesis doctoral propone una estrategia novedosa de análisis de la dinámica celular multi-escala que permite cuantificar patrones de manera inmediata y que además ofrece una representación que reconstruye la evolución de los procesos como los ven las células, en lugar de como son observados desde el microscopio. Esta metodología por tanto permite nuevas formas de análisis y comparación de embriones y tejidos durante la embriogénesis a partir de imágenes in-vivo. ABSTRACT The embryogenesis is the process from which a single cell turns into a living organism. Through several stages of development, the cell population proliferates at the same time the embryo shapes and the organs develop gaining their functionality. This is possible through genetic, biochemical and mechanical factors that are involved in a complex interaction of processes organized in different levels and in different spatio-temporal scales. The embryogenesis, through this complexity, develops in a robust and reproducible way, but allowing variability that makes possible the diversity of living specimens. The advances in physics of microscopes and the appearance of fluorescent proteins that can be attached to expression chains, reporting about structural and functional elements of the cell, have enabled for the in-vivo observation of embryogenesis. The imaging process results in sequences of high spatio-temporal resolution 3D+time data of the embryogenesis as a digital representation of the embryos that can be further analyzed, provided new image processing and data analysis techniques are developed. One of the most relevant and challenging lines of research in the field is the quantification of the mechanical factors and processes involved in the shaping process of the embryo and their interactions with other embryogenesis factors such as genetics. Due to the complexity of the processes, studies have focused on specific problems and scales controlled in the experiments, posing and testing hypothesis to gain new biological insight. However, methodologies are often difficult to be exported to study other biological phenomena or specimens. This PhD Thesis is framed within this paradigm of research and tries to propose a systematic methodology to quantify the emergent deformation patterns from the motion estimated in in-vivo images of embryogenesis. Thanks to this strategy it would be possible to quantify not only local mechanisms, but to discover and characterize the scales of mechanical organization within the embryo. The framework focuses on the quantification of the motion kinematics (deformation and strains), neglecting the causes of the motion (forces), from images in a non-invasive way. Experimental and methodological challenges hamper the quantification of exerted forces and the mechanical properties of tissues. However, a descriptive framework of deformation patterns provides valuable insight about the organization and scales of the mechanical interactions, along the embryo development. Such a characterization would help to improve mechanical models and progressively understand the complexity of embryogenesis. This framework relies on a Lagrangian representation of the cell dynamics system based on the trajectories of points moving along the deformation. This approach of analysis enables the reconstruction of the mechanical patterning as experienced by the cells and tissues. Thus, we can build temporal profiles of deformation along stages of development, comprising both the instantaneous events and the cumulative deformation history. The application of this framework to 3D + time data of zebrafish embryogenesis allowed us to discover mechanical profiles that stabilized through time forming structures that organize in a scale comparable to the map of cell differentiation (fate map), and also suggesting correlation with genetic patterns. The framework was also applied to the analysis of the amnioserosa tissue in the drosophila’s dorsal closure, revealing that the oscillatory contraction triggered by the acto-myosin network organized complexly coupling different scales: local force generation foci, cellular morphology control mechanisms and tissue geometrical constraints. In summary, this PhD Thesis proposes a theoretical framework for the analysis of multi-scale cell dynamics that enables to quantify automatically mechanical patterns and also offers a new representation of the embryo dynamics as experienced by cells instead of how the microscope captures instantaneously the processes. Therefore, this framework enables for new strategies of quantitative analysis and comparison between embryos and tissues during embryogenesis from in-vivo images.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

L’épaule est l’articulation la plus mobile et la plus instable du corps humain dû à la faible quantité de contraintes osseuses et au rôle des tissus mous qui lui confèrent au moins une dizaine de degrés de liberté. La mobilité de l’épaule est un facteur de performance dans plusieurs sports. Mais son instabilité engendre des troubles musculo-squelettiques, dont les déchirures de la coiffe des rotateurs sont fréquentes et les plus handicapantes. L’évaluation de l’amplitude articulaire est un indice commun de la fonction de l’épaule, toutefois elle est souvent limitée à quelques mesures planaires pour lesquelles les degrés de liberté varient indépendamment les uns des autres. Ces valeurs utilisées dans les modèles de simulation musculo-squelettiques peuvent amener à des solutions non physiologiques. L’objectif de cette thèse était de développer des outils pour la caractérisation de la mobilité articulaire tri-dimensionnelle de l’épaule, en passant par i) fournir une méthode et son approche expérimentale pour évaluer l’amplitude articulaire tridimensionnelle de l’épaule incluant des interactions entre les degrés de liberté ; ii) proposer une représentation permettant d’interpréter les données tri-dimensionnelles obtenues; iii) présenter des amplitudes articulaires normalisées, iv) implémenter une amplitude articulaire tridimensionnelle au sein d’un modèle de simulation numérique afin de générer des mouvements sportifs optimaux plus réalistes; v) prédire des amplitudes articulaires sécuritaires et vi) des exercices de rééducation sécuritaires pour des patients ayant subi une réparation de la coiffe des rotateurs. i) Seize sujets ont été réalisé séries de mouvements d’amplitudes maximales actifs avec des combinaisons entre les différents degrés de liberté de l’épaule. Un système d’analyse du mouvement couplé à un modèle cinématique du membre supérieur a été utilisé pour estimer les cinématiques articulaires tridimensionnelles. ii) L’ensemble des orientations définies par une séquence de trois angles a été inclus dans un polyèdre non convexe représentant l’espace de mobilité articulaire prenant en compte les interactions entre les degrés de liberté. La combinaison des séries d’élévation et de rotation est recommandée pour évaluer l’amplitude articulaire complète de l’épaule. iii) Un espace de mobilité normalisé a également été défini en englobant les positions atteintes par au moins 50% des sujets et de volume moyen. iv) Cet espace moyen, définissant la mobilité physiologiques, a été utilisé au sein d’un modèle de simulation cinématique utilisé pour optimiser la technique d’un élément acrobatique de lâcher de barres réalisée par des gymnastes. Avec l’utilisation régulière de limites articulaires planaires pour contraindre la mobilité de l’épaule, seulement 17% des solutions optimales sont physiologiques. En plus, d’assurer le réalisme des solutions, notre contrainte articulaire tridimensionnelle n’a pas affecté le coût de calculs de l’optimisation. v) et vi) Les seize participants ont également réalisé des séries d’amplitudes articulaires passives et des exercices de rééducation passifs. La contrainte dans l’ensemble des muscles de la coiffe des rotateurs au cours de ces mouvements a été estimée à l’aide d’un modèle musculo-squelettique reproduisant différents types et tailles de déchirures. Des seuils de contrainte sécuritaires ont été utilisés pour distinguer les amplitudes de mouvements risquées ou non pour l’intégrité de la réparation chirurgicale. Une taille de déchirure plus grande ainsi que les déchirures affectant plusieurs muscles ont contribué à réduire l’espace de mobilité articulaire sécuritaire. Principalement les élévations gléno-humérales inférieures à 38° et supérieures à 65°, ou réalisées avec le bras maintenu en rotation interne engendrent des contraintes excessives pour la plupart des types et des tailles de blessure lors de mouvements d’abduction, de scaption ou de flexion. Cette thèse a développé une représentation innovante de la mobilité de l’épaule, qui tient compte des interactions entre les degrés de liberté. Grâce à cette représentation, l’évaluation clinique pourra être plus exhaustive et donc élargir les possibilités de diagnostiquer les troubles de l’épaule. La simulation de mouvement peut maintenant être plus réaliste. Finalement, nous avons montré l’importance de personnaliser la rééducation des patients en termes d’amplitude articulaire, puisque des exercices passifs de rééducation précoces peuvent contribuer à une re-déchirure à cause d’une contrainte trop importante qu’ils imposent aux tendons.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

At Sleipner, CO2 is being separated from natural gas and injected into an underground saline aquifer for environmental purposes. Uncertainty in the aquifer temperature leads to uncertainty in the in situ density of CO2. In this study, gravity measurements were made over the injection site in 2002 and 2005 on top of 30 concrete benchmarks on the seafloor in order to constrain the in situ CO2 density. The gravity measurements have a repeatability of 4.3 µGal for 2003 and 3.5 µGal for 2005. The resulting time-lapse uncertainty is 5.3 µGal. Unexpected benchmark motions due to local sediment scouring contribute to the uncertainty. Forward gravity models are calculated based on both 3D seismic data and reservoir simulation models. The time-lapse gravity observations best fit a high temperature forward model based on the time-lapse 3D seismics, suggesting that the average in situ CO2 density is about to 530kg/m**3. Uncertainty in determining the average density is estimated to be ±65 kg/m**3 (95% confidence), however, this does not include uncertainties in the modeling. Additional seismic surveys and future gravity measurements will put better constraints on the CO2 density and continue to map out the CO2 flow.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Subsurface stratigraphic analysis of Devonian strata from the Rio do Peixe Basin, newly recognized by palynological studies, has resulted in the identification of two new lithostratigraphic units assembled in the Santa Helena Group. The Pilões Formation, the lower unit, is composed mainly of dark mudstones and medium-tovery fine-grained sandstones, with minor conglomerates and breccias. The Triunfo Formation, the upper unit, comprises whitish grey, kaolinitic, coarse-grained to conglomeratic, cross stratified sandstones and conglomerates, with interbedded mudstones and fine-grained sandstones. These units were characterized using cores, sidewall and cuttings samples, conventional logs and image log, from three wells drilled by PETROBRAS, and 3D seismic data. The Pilões Formation is interpreted as prodeltaic facies, with lesser associated subaqueous talus, debrite and sandy turbidite lobe facies, distal part of fandelta and braided fluviodeltaic facies of Triunfo Formation. The Santa Helena Group corresponds to the Lower Devonian tectono-sequence deposited in a NW-SE-trending graben during a transgressiveregressive cycle. With 343 meters of thickness (isochore) in well 1-PIL-1-PB (Pilões 1), this sequence has a non-conformity at the lower boundary and its upper boundary is an unconformity with the Lower Cretaceous tectono-sequence (Rio do Peixe Group), that represents a hiatus of about 265 million years. Ignimbrites and coignimbrite breccias (Poço da Jurema volcanic breccia), related to an unknown pyroclastic volcanic event, were recognized at the northern margin of the Sousa halfgraben. Evidence from well data suggests that this event is coeval with the Devonian graben filling. The present study indicates a polyhistorical tectono-volcanosedimentary evolution of the basin. This lithostratigraphic update brings new perspectives for geological research in the Rio do Peixe Basin, as well as in other inland basins of the Northeastern of Brazil. The results of the research also contribute to the kwnoledge of the Borborema Province and western Gondwana paleogeography during the Early Devonian.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

L’épaule est l’articulation la plus mobile et la plus instable du corps humain dû à la faible quantité de contraintes osseuses et au rôle des tissus mous qui lui confèrent au moins une dizaine de degrés de liberté. La mobilité de l’épaule est un facteur de performance dans plusieurs sports. Mais son instabilité engendre des troubles musculo-squelettiques, dont les déchirures de la coiffe des rotateurs sont fréquentes et les plus handicapantes. L’évaluation de l’amplitude articulaire est un indice commun de la fonction de l’épaule, toutefois elle est souvent limitée à quelques mesures planaires pour lesquelles les degrés de liberté varient indépendamment les uns des autres. Ces valeurs utilisées dans les modèles de simulation musculo-squelettiques peuvent amener à des solutions non physiologiques. L’objectif de cette thèse était de développer des outils pour la caractérisation de la mobilité articulaire tri-dimensionnelle de l’épaule, en passant par i) fournir une méthode et son approche expérimentale pour évaluer l’amplitude articulaire tridimensionnelle de l’épaule incluant des interactions entre les degrés de liberté ; ii) proposer une représentation permettant d’interpréter les données tri-dimensionnelles obtenues; iii) présenter des amplitudes articulaires normalisées, iv) implémenter une amplitude articulaire tridimensionnelle au sein d’un modèle de simulation numérique afin de générer des mouvements sportifs optimaux plus réalistes; v) prédire des amplitudes articulaires sécuritaires et vi) des exercices de rééducation sécuritaires pour des patients ayant subi une réparation de la coiffe des rotateurs. i) Seize sujets ont été réalisé séries de mouvements d’amplitudes maximales actifs avec des combinaisons entre les différents degrés de liberté de l’épaule. Un système d’analyse du mouvement couplé à un modèle cinématique du membre supérieur a été utilisé pour estimer les cinématiques articulaires tridimensionnelles. ii) L’ensemble des orientations définies par une séquence de trois angles a été inclus dans un polyèdre non convexe représentant l’espace de mobilité articulaire prenant en compte les interactions entre les degrés de liberté. La combinaison des séries d’élévation et de rotation est recommandée pour évaluer l’amplitude articulaire complète de l’épaule. iii) Un espace de mobilité normalisé a également été défini en englobant les positions atteintes par au moins 50% des sujets et de volume moyen. iv) Cet espace moyen, définissant la mobilité physiologiques, a été utilisé au sein d’un modèle de simulation cinématique utilisé pour optimiser la technique d’un élément acrobatique de lâcher de barres réalisée par des gymnastes. Avec l’utilisation régulière de limites articulaires planaires pour contraindre la mobilité de l’épaule, seulement 17% des solutions optimales sont physiologiques. En plus, d’assurer le réalisme des solutions, notre contrainte articulaire tridimensionnelle n’a pas affecté le coût de calculs de l’optimisation. v) et vi) Les seize participants ont également réalisé des séries d’amplitudes articulaires passives et des exercices de rééducation passifs. La contrainte dans l’ensemble des muscles de la coiffe des rotateurs au cours de ces mouvements a été estimée à l’aide d’un modèle musculo-squelettique reproduisant différents types et tailles de déchirures. Des seuils de contrainte sécuritaires ont été utilisés pour distinguer les amplitudes de mouvements risquées ou non pour l’intégrité de la réparation chirurgicale. Une taille de déchirure plus grande ainsi que les déchirures affectant plusieurs muscles ont contribué à réduire l’espace de mobilité articulaire sécuritaire. Principalement les élévations gléno-humérales inférieures à 38° et supérieures à 65°, ou réalisées avec le bras maintenu en rotation interne engendrent des contraintes excessives pour la plupart des types et des tailles de blessure lors de mouvements d’abduction, de scaption ou de flexion. Cette thèse a développé une représentation innovante de la mobilité de l’épaule, qui tient compte des interactions entre les degrés de liberté. Grâce à cette représentation, l’évaluation clinique pourra être plus exhaustive et donc élargir les possibilités de diagnostiquer les troubles de l’épaule. La simulation de mouvement peut maintenant être plus réaliste. Finalement, nous avons montré l’importance de personnaliser la rééducation des patients en termes d’amplitude articulaire, puisque des exercices passifs de rééducation précoces peuvent contribuer à une re-déchirure à cause d’une contrainte trop importante qu’ils imposent aux tendons.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

There is an increased need for 3D recording of archaeological sites and digital preservation of their artifacts. Digital photogrammetry with prosumer DSLR cameras is a suitable tool for recording epigraphy in particular, as it allows for the recording of inscribed surfaces with very high accuracy, often better than 2 mm and with only a short time spent in the field. When photogrammetry is fused with other computational photography techniques like panoramic tours and Reflectance Transformation Imaging, a workflow exists to rival traditional LiDAR­based methods. The difficulty however, arises in the presentation of 3D data. It requires an enormous amount of storage and end­user sophistication. The proposed solution is to use game­engine technology and high definition virtual tours to provide not only scholars, but also the general public with an uncomplicated interface to interact with the detailed 3D epigraphic data. The site of Stobi, located near Gradsko, in the Former Yugoslav Republic of Macedonia (FYROM) was used as a case study to demonstrate the effectiveness of RTI, photogrammetry and virtual tour imaging working in combination. A selection of nine sets of inscriptions from the archaeological site were chosen to demonstrate the range of application for the techniques. The chosen marble, sandstone and breccia inscriptions are representative of the varying levels of deterioration and degradation of the epigraphy at Stobi, in which both their rates of decay and resulting legibility is varied. This selection includes those which are treated and untreated stones as well as those in situ and those in storage. The selection consists of both Latin and Greek inscriptions with content ranging from temple dedication inscriptions to statue dedications. This combination of 3D modeling techniques presents a cost and time efficient solution to both increase the legibility of severely damaged stones and to digitally preserve the current state of the inscriptions.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

We evaluated the performance of an optical camera based prospective motion correction (PMC) system in improving the quality of 3D echo-planar imaging functional MRI data. An optical camera and external marker were used to dynamically track the head movement of subjects during fMRI scanning. PMC was performed by using the motion information to dynamically update the sequence's RF excitation and gradient waveforms such that the field-of-view was realigned to match the subject's head movement. Task-free fMRI experiments on five healthy volunteers followed a 2×2×3 factorial design with the following factors: PMC on or off; 3.0mm or 1.5mm isotropic resolution; and no, slow, or fast head movements. Visual and motor fMRI experiments were additionally performed on one of the volunteers at 1.5mm resolution comparing PMC on vs PMC off for no and slow head movements. Metrics were developed to quantify the amount of motion as it occurred relative to k-space data acquisition. The motion quantification metric collapsed the very rich camera tracking data into one scalar value for each image volume that was strongly predictive of motion-induced artifacts. The PMC system did not introduce extraneous artifacts for the no motion conditions and improved the time series temporal signal-to-noise by 30% to 40% for all combinations of low/high resolution and slow/fast head movement relative to the standard acquisition with no prospective correction. The numbers of activated voxels (p<0.001, uncorrected) in both task-based experiments were comparable for the no motion cases and increased by 78% and 330%, respectively, for PMC on versus PMC off in the slow motion cases. The PMC system is a robust solution to decrease the motion sensitivity of multi-shot 3D EPI sequences and thereby overcome one of the main roadblocks to their widespread use in fMRI studies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Using the published KTeV samples of K(L) -> pi(+/-)e(-/+)nu and K(L) -> pi(+/-)mu(-/+)nu decays, we perform a reanalysis of the scalar and vector form factors based on the dispersive parametrization. We obtain phase-space integrals I(K)(e) = 0.15446 +/- 0.00025 and I(K)(mu) = 0.10219 +/- 0.00025. For the scalar form factor parametrization, the only free parameter is the normalized form factor value at the Callan-Treiman point (C); our best-fit results in InC = 0.1915 +/- 0.0122. We also study the sensitivity of C to different parametrizations of the vector form factor. The results for the phase-space integrals and C are then used to make tests of the standard model. Finally, we compare our results with lattice QCD calculations of F(K)/F(pi) and f(+)(0).