994 resultados para 3D measurement
Resumo:
The use of computer-assisted technologies such as CAD - Computed Aided Design, CAM - Computed Aided Manufacturing, CAE - Computed Aided Engineering and CNC - Computed Numerical Control, are priorities in engineering and product designers. However, the dimensional measurement between the virtual and the real product design requires research, and dissemination procedures among its users. This work aims to use these technologies, through analysis and measurement of a CNC milling machine, designed and assembled in the university. Through the use of 3D scanning, and analyzing images of the machined samples, and its original virtual files, it was possible to compare the sizes of these samples in counterposition to the original virtual dimensions, we can state that the distortions between the real and virtual, are within acceptable limits for this type of equipment. As a secondary objective, this work seeks to disseminate and make more accessible the use of these technologies.
Resumo:
Objective: To compare the agreement of multiplanar and rendering modes in the assessment fetal atrioventricular valves (mitral and tricuspid) areas by three-dimensional (3D) ultrasonography using the software spatio-temporal image correlation (STIC). Methods: We conducted a prospective cross-sectional study with normal pregnant women, with single fetuses, between 18-33 weeks. To measure the areas, we used the plan of four-chamber view. In the case of multiplanar, the plane was rotated on the axis "Z" form the heart to position at 9h. For rendering, the green line (region of interest - ROI) was placed from the atria of the heart perpendicular to the crux. The agreement was assessed by a Bland-Altman (limits of agreement) using the relative difference between the measures: ((rendering mode) - (multiplanar mode)) / (average). Results: 328 fetuses were evaluated. We have not identified the occurrence of systematic error between methods: the average relative difference was 1.62% (-2.07% to 5.32%, confidence interval 95%) in the mitral and 1.77% (- 1.08% to 4.62%) in the tricuspid valve. The limits of agreement between methods were -65.26% to 68.51% for the mitral and -49.91% to 53.45% for the tricuspid. Conclusions: There was no systematic error between modes and thus the observed values for the area of fetal atrioventricular valves can be used for comparisons needs to be corrected. However, relatively large variations may be observed when repeating the measurement area by different modes.
Resumo:
Arthropodenhämocyanine und Molluskenhämocyanine, die extrazellulären Atmungsproteine der Arthropoden und Mollusken, unterscheiden sich grundsätzlich im Aufbau, besitzen aber ähnliche aktive Zentren, welche in ihrer oxydierten Form für die Blaufärbung der Hämocyanine verantwortlich sind. Sauerstoff wird im Bindungszentrum zwischen zwei, von sechs Histidinen ligandierten, Kupfer(I)Ionen gebunden. Arthropodenhämocyanine bauen sich artspezifisch aus 1, 2, 4, 6, oder 8 Hexameren mit D3-Symmetrie auf. Die Untereinheiten von je ca. 75 kDa falten sich in drei Domänen unterschiedlicher Funktionen. Der komplexe, hierarchische Zusammenbau der Arthropodenhämocyanine hängt von der Heterogenität der Untereinheiten ab. Die 7 verschieden Sequenzen des 4x6-Hämocyanins von Eurypelma californicum (EcHc) sind biochemisch in der Quartärstruktur lokalisiert. Bislang fehlte noch ein unabhängig erstelltes 3D-Modell der geometrischen Gesamtstruktur welche die hexamere und monomere Topographie eindeutig zeigt. Dessen Erstellung war Gegenstand dieser Arbeit, in Verbindung mit der Zielsetzung, die 3D-Rekonstruktion in den beiden extremen physiologischen Zuständen, mit und ohne gebundenen Sauerstoff, zu erzeugen. Dazu wurden in einer eigens entwickelten Atmosphären-Präparationskammer die Proteine in Lösung schockgefrorenen und mittels Cryo-3D-Elektronenmikroskopie gemessen. Aus den daraus gewonnen Projektionsbildern ließen sich mit der ”Single Particle Analyse“ die 3D-Informationen zurückberechnen. Die 3D-Rekonstruktionen wurden mit der publizierten Röntgenkristallstruktur des hexameren Referenz-Hämocyanins der Languste Panulirus interruptus verifiziert. Die Rekonstruktionen erlaubten die eindeutige Messung diverser in der Literatur diskutierter Parameter der Architektur des 4x6-EcHc und darüber hinaus weiterer geometrischer Parameter, welche hier erstmals veröffentlicht werden. SAXS-Daten sagen extreme Translationen und Rotationen von Teilquartärstrukturen zwischen oxy- und deoxy-EcHc voraus, was von den 3D-Rekonstruktionen der beiden Zustände nicht bestätigt werden konnte: Die 16 Å Rekonstruktion der Deoxyform weicht geometrisch nicht von der 21 Å Rekonstruktion der Oxyform ab. Die Einpassung der publizierten Röntgenstruktur der Untereinheit II des Hämocyanin des Pfeilschwanzkrebses Limulus polyphemus in die Rekonstruktionen unterstützt eine auf der hexameren Hierarchieebene lokalisierte Dynamik der Oxygenierung. Mittels Einpassung modellierter molekularer Strukturen der EcHc-Sequenzen konnte eine erste Vermutung zur Lokalisation der beiden zentralen Linker-Untereinheiten b und c des 4x6-Moleküls gemacht werden: Demnach würde Untereinheit b in den exponierten Hexameren des Moleküls liegen. Aussagen über die Quartärstrukturbindungen auf molekularer Ebene aufgrund der Einpassung modellierter molekularer Daten in die Rekonstruktionen sind als spekulativ einzustufen: a) Die Auflösung der Rekonstruktion ist verbesserungswürdig. b) Es gibt keine adäquate Vorlage für eine verlässliche Strukturvorhersage; die verschiedenen EcHc-Sequenzen liegen nur als Modellierung vor. c) Es wäre eine flexible Einpassung notwendig, um Ungenauigkeiten in den modellierten Strukturen durch Sekundärstrukturanpassung zu minimieren.
Resumo:
Sowohl in der Natur als auch in der Industrie existieren thermisch induzierte Strömungen. Von Interesse für diese Forschungsarbeit sind dabei die Konvektionen im Erdmantel sowie in den Glasschmelzwannen. Der dort stattfindende Materialtransport resultiert aus Unterschieden in der Dichte, der Temperatur und der chemischen Konzentration innerhalb des konvektierenden Materials. Um das Verständnis für die ablaufenden Prozesse zu verbessern, werden von zahlreichen Forschergruppen numerische Modellierungen durchgeführt. Die Verifikation der dafür verwendeten Algorithmen erfolgt meist über die Analyse von Laborexperimenten. Im Vordergrund dieser Forschungsarbeit steht die Entwicklung einer Methode zur Bestimmung der dreidimensionalen Temperaturverteilung für die Untersuchung von thermisch induzierten Strömungen in einem Versuchsbecken. Eine direkte Temperaturmessung im Inneren des Versuchsmaterials bzw. der Glasschmelze beeinflusst allerdings das Strömungsverhalten. Deshalb wird die geodynamisch störungsfrei arbeitende Impedanztomographie verwendet. Die Grundlage dieser Methode bildet der erweiterte Arrhenius-Zusammenhang zwischen Temperatur und spezifischer elektrischer Leitfähigkeit. Während der Laborexperimente wird ein zähflüssiges Polyethylenglykol-Wasser-Gemisch in einem Becken von unten her erhitzt. Die auf diese Weise generierten Strömungen stellen unter Berücksichtigung der Skalierung ein Analogon sowohl zu dem Erdmantel als auch zu den Schmelzwannen dar. Über mehrere Elektroden, die an den Beckenwänden installiert sind, erfolgen die geoelektrischen Messungen. Nach der sich anschließenden dreidimensionalen Inversion der elektrischen Widerstände liegt das Modell mit der Verteilung der spezifischen elektrischen Leitfähigkeit im Inneren des Versuchsbeckens vor. Diese wird mittels der erweiterten Arrhenius-Formel in eine Temperaturverteilung umgerechnet. Zum Nachweis der Eignung dieser Methode für die nichtinvasive Bestimmung der dreidimensionalen Temperaturverteilung wurden mittels mehrerer Thermoelemente an den Beckenwänden zusätzlich direkte Temperaturmessungen durchgeführt und die Werte miteinander verglichen. Im Wesentlichen sind die Innentemperaturen gut rekonstruierbar, wobei die erreichte Messgenauigkeit von der räumlichen und zeitlichen Auflösung der Gleichstromgeoelektrik abhängt.
Resumo:
Procedures for quantitative walking analysis include the assessment of body segment movements within defined gait cycles. Recently, methods to track human body motion using inertial measurement units have been suggested. It is not known if these techniques can be readily transferred to clinical measurement situations. This work investigates the aspects necessary for one inertial measurement unit mounted on the lower back to track orientation, and determine spatio-temporal features of gait outside the confines of a conventional gait laboratory. Apparent limitations of different inertial sensors can be overcome by fusing data using methods such as a Kalman filter. The benefits of optimizing such a filter for the type of motion are unknown. 3D accelerations and 3D angular velocities were collected for 18 healthy subjects while treadmill walking. Optimization of Kalman filter parameters improved pitch and roll angle estimates when compared to angles derived using stereophotogrammetry. A Weighted Fourier Linear Combiner method for estimating 3D orientation angles by constructing an analytical representation of angular velocities and allowing drift free integration is also presented. When tested this method provided accurate estimates of 3D orientation when compared to stereophotogrammetry. Methods to determine spatio-temporal features from lower trunk accelerations generally require knowledge of sensor alignment. A method was developed to estimate the instants of initial and final ground contact from accelerations measured by a waist mounted inertial device without rigorous alignment. A continuous wavelet transform method was used to filter and differentiate the signal and derive estimates of initial and final contact times. The technique was tested with data recorded for both healthy and pathologic (hemiplegia and Parkinson’s disease) subjects and validated using an instrumented mat. The results show that a single inertial measurement unit can assist whole body gait assessment however further investigation is required to understand altered gait timing in some pathological subjects.
Resumo:
For crime scene investigation in cases of homicide, the pattern of bloodstains at the incident site is of critical importance. The morphology of the bloodstain pattern serves to determine the approximate blood source locations, the minimum number of blows and the positioning of the victim. In the present work, the benefits of the three-dimensional bloodstain pattern analysis, including the ballistic approximation of the trajectories of the blood drops, will be demonstrated using two illustrative cases. The crime scenes were documented in 3D, using the non-contact methods digital photogrammetry, tachymetry and laser scanning. Accurate, true-to-scale 3D models of the crime scenes, including the bloodstain pattern and the traces, were created. For the determination of the areas of origin of the bloodstain pattern, the trajectories of up to 200 well-defined bloodstains were analysed in CAD and photogrammetry software. The ballistic determination of the trajectories was performed using ballistics software. The advantages of this method are the short preparation time on site, the non-contact measurement of the bloodstains and the high accuracy of the bloodstain analysis. It should be expected that this method delivers accurate results regarding the number and position of the areas of origin of bloodstains, in particular the vertical component is determined more precisely than using conventional methods. In both cases relevant forensic conclusions regarding the course of events were enabled by the ballistic bloodstain pattern analysis.
Resumo:
The spine is a complex structure that provides motion in three directions: flexion and extension, lateral bending and axial rotation. So far, the investigation of the mechanical and kinematic behavior of the basic unit of the spine, a motion segment, is predominantly a domain of in vitro experiments on spinal loading simulators. Most existing approaches to measure spinal stiffness intraoperatively in an in vivo environment use a distractor. However, these concepts usually assume a planar loading and motion. The objective of our study was to develop and validate an apparatus, that allows to perform intraoperative in vivo measurements to determine both the applied force and the resulting motion in three dimensional space. The proposed setup combines force measurement with an instrumented distractor and motion tracking with an optoelectronic system. As the orientation of the applied force and the three dimensional motion is known, not only force-displacement, but also moment-angle relations could be determined. The validation was performed using three cadaveric lumbar ovine spines. The lateral bending stiffness of two motion segments per specimen was determined with the proposed concept and compared with the stiffness acquired on a spinal loading simulator which was considered to be gold standard. The mean values of the stiffness computed with the proposed concept were within a range of ±15% compared to data obtained with the spinal loading simulator under applied loads of less than 5 Nm.
Resumo:
The measurement of fluid volumes in cases of pericardial effusion is a necessary procedure during autopsy. With the increased use of virtual autopsy methods in forensics, the need for a quick volume measurement method on computed tomography (CT) data arises, especially since methods such as CT angiography can potentially alter the fluid content in the pericardium. We retrospectively selected 15 cases with hemopericardium, which underwent post-mortem imaging and autopsy. Based on CT data, the pericardial blood volume was estimated using segmentation techniques and downsampling of CT datasets. Additionally, a variety of measures (distances, areas and 3D approximations of the effusion) were examined to find a quick and easy way of estimating the effusion volume. Segmentation of CT images as shown in the present study is a feasible method to measure the pericardial fluid amount accurately. Downsampling of a dataset significantly increases the speed of segmentation without losing too much accuracy. Some of the other methods examined might be used to quickly estimate the severity of the effusion volumes.
Resumo:
BACKGROUND: The aim of this study was to determine the performance of a new, 3D-monitor based, objective stereotest in children under the age of four. METHODS: Random-dot circles (diameter 10 cm, crossed, disparity of 0.34 degrees) randomly changing their position were presented on an 3D-monitor while eye movements were monitored by infrared photo-oculography. If > or = 3 consecutive stimuli were seen, a positive response was assumed. One hundred thirty-four normal children aged 2 months to 4 years (average 17+/-15.3 months) were examined. RESULTS: Below the age of 12 months, we were not able to obtain a response to the 3D stimulus. For older children the following rates of positive responses were found: 12-18 months 25%, 18-24 months 10%, 24-30 months 16%, 30-36 months 57%, 36-42 months 100%, and 42-48 months 91%. Multiple linear logistic regression showed a significant influence on stimulus recognition of the explanatory variables age (p<0.00001) and child cooperation (p<0.001), but not of gender (p>0.1). CONCLUSIONS: This 3D-monitor based stereotest allows an objective measurement of random-dot stereopsis in younger children. It might open new ways to screen children for visual abnormalities and to study the development of stereovision. However, the current experimental setting does not allow determining random-dot stereopsis in children younger than 12 months.
Resumo:
Human heteromeric amino acid transporters (HATs) are membrane protein complexes that facilitate the transport of specific amino acids across cell membranes. Loss of function or overexpression of these transporters is implicated in several human diseases such as renal aminoacidurias and cancer. HATs are composed of two subunits, a heavy and a light subunit, that are covalently connected by a disulphide bridge. Light subunits catalyse amino acid transport and consist of twelve transmembrane α-helix domains. Heavy subunits are type II membrane N-glycoproteins with a large extracellular domain and are involved in the trafficking of the complex to the plasma membrane. Structural information on HATs is scarce because of the difficulty in heterologous overexpression. Recently, we had a major breakthrough with the overexpression of a recombinant HAT, 4F2hc-LAT2, in the methylotrophic yeast Pichia pastoris. Microgram amounts of purified protein made possible the reconstruction of the first 3D map of a human HAT by negative-stain transmission electron microscopy. Here we report the important stabilization of purified human 4F2hc-LAT2 using a combination of two detergents, i.e., n-dodecyl-β-D-maltopyranoside and lauryl maltose neopentyl glycol, and cholesteryl hemisuccinate. The superior quality and stability of purified 4F2hc-LAT2 allowed the measurement of substrate binding by scintillation proximity assay. In addition, an improved 3D map of this HAT could be obtained. The detergent-induced stabilization of the purified human 4F2hc-LAT2 complex presented here paves the way towards its crystallization and structure determination at high-resolution, and thus the elucidation of the working mechanism of this important protein complex at the molecular level.
Resumo:
Hip dysplasia is characterized by insufficient femoral head coverage (FHC). Quantification of FHC is of importance as the underlying goal of the surgery to treat hip dysplasia is to restore a normal acetabular morphology and thereby to improve FHC. Unlike a pure 2D X-ray radiograph-based measurement method or a pure 3D CT-based measurement method, previously we presented a 2.5D method to quantify FHC from a single anteriorposterior (AP) pelvic radiograph. In this study, we first quantified and compared 3D FHC between a normal control group and a patient group using a CT-based measurement method. Taking the CT-based 3D measurements of FHC as the gold standard, we further quantified the bias, precision and correlation between the 2.5D measurements and the 3D measurements on both the control group and the patient group. Based on digitally reconstructed radiographs (DRRs), we investigated the influence of the pelvic tilt on the 2.5D measurements of FHC. The intraclass correlation coefficients (ICCs) for absolute agreement was used to quantify interobserver reliability and intraobserver reproducibility of the 2.5D measurement technique. The Pearson correlation coefficient, r, was used to determine the strength of the linear association between the 2.5D and the 3D measurements. Student's t-test was used to determine whether the differences between different measurements were statistically significant. Our experimental results demonstrated that both the interobserver reliability and the intraobserver reproducibility of the 2.5D measurement technique were very good (ICCs > 0.8). Regression analysis indicated that the correlation was very strong between the 2.5D and the 3D measurements (r = 0.89, p < 0.001). Student's t-test showed that there were no statistically significant differences between the 2.5D and the 3D measurements of FHC on the patient group (p > 0.05). The results of this study provided convincing evidence demonstrating the validity of the 2.5D measurements of FHC from a single AP pelvic radiograph and proved that it could serve as a surrogate for 3D CT-based measurements. Thus it may be possible to use this method to avoid a CT scan for the purpose of estimating 3D FHC in diagnosis and post-operative treatment evaluation of patients with hip dysplasia.
Resumo:
Research in stereoscopic 3D coding, transmission and subjective assessment methodology depends largely on the availability of source content that can be used in cross-lab evaluations. While several studies have already been presented using proprietary content, comparisons between the studies are difficult since discrepant contents are used. Therefore in this paper, a freely available dataset of high quality Full-HD stereoscopic sequences shot with a semiprofessional 3D camera is introduced in detail. The content was designed to be suited for usage in a wide variety of applications, including high quality studies. A set of depth maps was calculated from the stereoscopic pair. As an application example, a subjective assessment has been performed using coding and spatial degradations. The Absolute Category Rating with Hidden Reference method was used. The observers were instructed to vote on video quality only. Results of this experiment are also freely available and will be presented in this paper as a first step towards objective video quality measurement for 3DTV.
Resumo:
Underwater video transects have become a common tool for quantitative analysis of the seafloor. However a major difficulty remains in the accurate determination of the area surveyed as underwater navigation can be unreliable and image scaling does not always compensate for distortions due to perspective and topography. Depending on the camera set-up and available instruments, different methods of surface measurement are applied, which make it difficult to compare data obtained by different vehicles. 3-D modelling of the seafloor based on 2-D video data and a reference scale can be used to compute subtransect dimensions. Focussing on the length of the subtransect, the data obtained from 3-D models created with the software PhotoModeler Scanner are compared with those determined from underwater acoustic positioning (ultra short baseline, USBL) and bottom tracking (Doppler velocity log, DVL). 3-D model building and scaling was successfully conducted on all three tested set-ups and the distortion of the reference scales due to substrate roughness was identified as the main source of imprecision. Acoustic positioning was generally inaccurate and bottom tracking unreliable on rough terrain. Subtransect lengths assessed with PhotoModeler were on average 20% longer than those derived from acoustic positioning due to the higher spatial resolution and the inclusion of slope. On a high relief wall bottom tracking and 3-D modelling yielded similar results. At present, 3-D modelling is the most powerful, albeit the most time-consuming, method for accurate determination of video subtransect dimensions.
Resumo:
A phantom that can be used for mapping geometric distortion in magnetic resonance imaging (MRI) is described. This phantom provides an array of densely distributed control points in three-dimensional (3D) space. These points form the basis of a comprehensive measurement method to correct for geometric distortion in MR images arising principally from gradient field non-linearity and magnet field inhomogeneity. The phantom was designed based on the concept that a point in space can be defined using three orthogonal planes. This novel design approach allows for as many control points as desired. Employing this novel design, a highly accurate method has been developed that enables the positions of the control points to be measured to sub-voxel accuracy. The phantom described in this paper was constructed to fit into a body coil of a MRI scanner, (external dimensions of the phantom were: 310 mm x 310 mm x 310 mm), and it contained 10,830 control points. With this phantom, the mean errors in the measured coordinates of the control points were on the order of 0.1 mm or less, which were less than one tenth of the voxel's dimensions of the phantom image. The calculated three-dimensional distortion map, i.e., the differences between the image positions and true positions of the control points, can then be used to compensate for geometric distortion for a full image restoration. It is anticipated that this novel method will have an impact on the applicability of MRI in both clinical and research settings. especially in areas where geometric accuracy is highly required, such as in MR neuro-imaging. (C) 2004 Elsevier Inc. All rights reserved.