872 resultados para 330810 Tecnología de aguas residuales


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The wastewater discharge produces impacts on receiving water bodies. Nutrients as P produce implications on lentic systems because they accelerate the eutrophication processes. Several technologies for P removal from the wastewater have been used: physic chemical treatment systems with important effects by coagulant products addition; biological processes based on anaerobic and aerobic conditions with great implications on the required volume; natural systems as stabilization ponds and irrigation require bigger areas and post-treatment processes. The aerobic fluidized bed reactors with internal circulation (AFBRIC) are compact options with high concentrations of active biomass that have demonstrated their capacity for organic matter and N removal. For sewage from the wastewater pumping station of Ilha Solteira city and effluents of a recirculation aquaculture system (RAS) for semi-intensive tilapia farming, the reactive P and total P removal efficiency in three AFBRIC with 250 mm external tube diameter and different internal tube diameter (ITD), for two different support media at different concentrations was evaluated. The average reactive P removal efficiency for domestic wastewater to hydraulic retention time (HRT) of 3 hours and 125 mm ITD reactor varied from 25,6 to 38,4% and with 150 mm ITD reactor varied from 27,5 to 32,5%; the average total P removal for the RAS wastewater at a HRT of 0,19 hours and 100 mm ITD was of 32,7%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[ES] En el presente trabajo se ha comparado la eficiencia de los tratamientos biológicos y fotocatalíticos en la depuración de aguas contaminadas con dos pesticidas: Pirimetanil y Triadimenol, ampliamente utilizados como fungicidas sistémicos en la lucha contra plagas de hongos en los cultivos de tomate de la isla de Gran Canaria. Ambos compuestos son considerados tóxicos para organismos acuáticos, hecho que justifica la necesidad de estudiar un tratamiento efectivo de depuración de aguas residuales que los contengan, antes de proceder a su vertido. Paralelamente, se ha llevado a cabo el mismo estudio con otro contaminante orgánico: Resorcinol, con mayor biodegradabilidad que los pesticidas estudiados. Los resultados obtenidos en el presente trabajo indican que las aguas contaminadas con ambos pesticidas deben ser tratadas mediante procesos fotocatalíticos, mientras que, en el caso de Resorcinol, el tratamiento debe ser mediante procesos de depuración biológicos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Universidad de Las Palmas de Gran Canaria. Departamento de Biología. Centro de Algología Aplicada

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Helianthus tuberosus L. presenta potencial para producir etanol, sustituto de la nafta, y que deberá incorporarse a la misma en un 5% a partir del 2010 en Argentina. Hay antecedentes que señalan que a partir de 50 toneladas de tubérculos pueden obtenerse 4500 l de etanol. En este trabajo se comparó el rendimiento de dos variedades de topinambur regado con agua residual urbana o cloacal (AC) y agua subterránea (AS). El ensayo se realizó en la planta de tratamiento de agua cloacal de Obras Sanitarias Mendoza en el Departamento Tunuyán (33°32’89’’ S y 69°00’80’’ O), Mendoza, Argentina. El potencial para producir bioetanol se estimó a partir de la cantidad de hidratos de carbono fermentables en los tubérculos. El rendimiento de tubérculos presentó diferencias entre los tratamientos de riego, siendo de 177750 kg/ha en AC y de 144000 kg/ha en AS. La estimación del potencial para producir etanol generó un valor de 15000 l de alcohol en las parcelas regadas con AC y 13000 l en las regadas con AS. Para obtener 1 l de alcohol a partir de los tubérculos serían necesarios alrededor de 11 kg, relacionado con un valor de sólidos solubles de 16% en los mismos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El aceite de colza es comestible pero también puede utilizarse en la producción de biodiesel. Cuando el destino es el energético, el cultivo puede regarse con aguas residuales urbanas o cloacales. La mayor proporción del uso de éstas en el mundo ocurre en regiones áridas donde otras fuentes de agua son escasas, situación que se plantea en los oasis irrigados de Mendoza. En este trabajo se comparó el rendimiento de un cultivar invernal de colza regado con agua cloacal (AC) y agua subterránea (AS), y su potencial para producir biodiesel. La experiencia se llevó a cabo en una planta de tratamiento de agua cloacal de Obras Sanitarias en el departamento Tunuyán (33° 32’ 89’’ S; 69° 00’ 80’’ O; 859 m snm). El rendimiento de semilla de AC fue significativamente mayor que el de AS (7690 y 3886 kg/ha, respectivamente). La cantidad de biodiesel factible de producir por cada hectárea de cultivo asciende a 2800 kg en el tratamiento AC y a 1400 kg en AS. El uso de aguas residuales urbanas genera un nicho interesante para la producción de biocombustibles, utilizando un recurso hídrico con limitaciones para producir alimentos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Helianthus tuberosus L. produce tubérculos ricos en hidratos de carbono fermentables que pueden ser usados para producir etanol. Para el destino energético el cultivo puede ser regado con aguas residuales urbanas. La densidad poblacional en un cultivo de topinambur afecta los parámetros de crecimiento y rendimiento. Se evaluó el efecto de la densidad de plantación sobre el rendimiento de tubérculos. Se compararon 6 tratamientos de densidad, combinando 2 espaciamientos entre hileras (0,70 y 0,80 m) y 3 espaciamientos entre plantas en la hilera (0,30; 0,40 y 0,50 m), generando stands desde las 25.000 a 47.600 plantas/ha. Se presentaron los mayores rendimientos con distancias entre plantas en la hilera de 0,30 ó 0,40 m; no se presentaron diferencias en respuesta a la distancia entre hileras. Los componentes del rendimiento (rendimiento de tubérculos por planta, número de tubérculos por planta y tamaño medio de los tubérculos) respondieron a cambios en la densidad generados por la distancias entre plantas y fueron indiferentes a la variación de distancia entre hileras. La altura de las plantas, el número de tallos principales, el porcentaje de MS y de SS en los tubérculos no se modificaron ante variaciones de densidad.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La reutilización de las aguas residuales no es un concepto nuevo, en el año 1958 el Consejo Económico y Social de la Organización de las Naciones Unidas (ONU) enunció una nueva política, la sustitución de fuentes de recursos hídricos, con la declaración: «A menos que exista un exceso de agua, no deberá emplearse para cada uso agua de mayor calidad que la requerida por el mismo». En España en el periodo de sequía (1992-1995) se tuvo conciencia de la necesidad de hacer un mejor uso de los recursos hídricos existentes, empezando a verse claramente la necesidad de reutilizar las aguas residuales, sobre todo en las regiones con mayor déficit hídrico, como son la Costa Mediterránea, Baleares y Canarias. Al ser el agua el principal factor limitante para la agricultura en estas zonas, y el beneficio que su empleo reporta elevado, su uso debe ser esmerado y las posibilidades de reutilización maximizadas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Un incremento de la demanda del agua, junto con el aumento de la contaminación, ha provocado que hoy en día la reutilización de las aguas depuradas sea necesaria, pero la reutilización de aguas debe garantizar y minimizar los posibles riesgos sanitarios y medioambientales que su práctica pueda provocar. En España estos parámetros se encuentran regulados por el RD 1620/2007 relativo al régimen jurídico de la reutilización de las aguas depuradas. Las aguas regeneradas son aguas que ya han sido sometidas a un tratamiento de depuración, y a las cuales se aplica un posterior tratamiento adicional o complementario que permita adecuar su calidad al uso al que vaya a destinarse. Siendo requeridos para los distintos reúsos procesos de desinfección, uno de los principales sistemas utilizados es el cloro, debido a su sencilla aplicación y costos bajos, sin tomar en cuenta la posible formación de compuestos organohalogenados potencialmente cancerígenos. Es por esto que surge la necesidad de aplicar distintos sistemas de oxidación objeto de estudio en esta tesis, como el dióxido de cloro estabilizado, ozono y los procesos avanzados de oxidación (Advanced Oxidation Processes, AOP), ozono/peróxido y uv/peróxido. En esta tesis se investiga los rendimientos que pueden alcanzar estos sistemas en la eliminación de los ácidos húmicos y los fenoles, siendo las principales sustancias formadoras de subproductos de la desinfección, así mismo, se considera necesario garantizar la desinfección del agua a través del estudio de tres grupos de microrganismos, los coliformes totales, e. coli y enterococos, siendo un punto importante el posible recrecimiento microbiológico debido a una desinfección escasa, por la permanencia en el agua de los compuestos antes mencionados, o por alguna fuente de alimento que pudieran encontrar en el sistema de distribución. Lo más importante será la calidad que se pueda alcanzar con estos desinfectantes, con el fin de obtener agua para los distintos reúsos que existen en la actualidad. Y así no limitar los alcances que puede tener la reutilización de las aguas residuales. Basándose en lo antes mencionado se procedió a realizar la caracterización del agua del rio Manzanares, con el fin de determinar la cantidad de ácidos húmicos disueltos y fenoles, obteniendo valores bajos, se decidió incorporar a las muestras de rio 5 mg/L de estos compuestos, con el fin de observar de que manera podrían interferir en la desinfección de esta agua. De esta forma se logran obtener resultados óptimos de los sistemas de desinfección estudiados, siendo el Ozono un oxidante eficiente en la desinfección de los microrganismos y en la eliminación de ácidos húmicos y fenoles con tiempos de contacto cortos, mostrando deficiencias al permitir el recrecimiento de los coliformes totales. Del sistema de oxidación avanzada UV/Peróxido se determino como un eficiente desinfectante para garantizar la inexistencia de rebrotes, al paso del tiempo. Así mismo se concluye que tiene buenos rendimientos en la eliminación del ácido húmico y los fenoles. An increase in water demand, coupled with increasing pollution, has caused today reuse of treated water is necessary, but must ensure water reuse and minimize potential health and environmental risks that their practice is cause. In Spain these parameters are regulated by Royal Decree 1620/2007 on the legal regime of the reuse of treated water. The reclaimed water is water that has already been subjected to a depuration treatment, which is applied as a subsequent further treatment that will bring quality to the use to which is to be delivered. As required for various reuses disinfection processes, one of the main systems used is chlorine, due to its simple implementation and low costs, without taking into account the possible formation of potentially carcinogenic halogenated organic compounds. That is why there is a need to apply different oxidation systems studied in this thesis, as stabilized chlorine dioxide, ozone and advanced oxidation processes (AOP), ozone/peroxide and UV/peroxide. This thesis investigates the rates can reach these systems in removing humic acids and phenols, the main substances forming disinfection byproducts, likewise, it is considered necessary to ensure water disinfection through the study of three groups of microorganisms, total coliform, e. coli and enterococci, the important point being a possible regrowth due to microbiological disinfection scarce, the water remaining on the aforementioned compounds, or a food source which may be found in the distribution system. The most important quality is that achievable with these disinfectants, with the water to obtain various reuses that exist today. And thus not limit the scope that can be reuse of wastewater. Based on the above we proceeded to perform characterization Manzanares river water, in order to determine the quantity of dissolved humic acids and phenols, obtaining low values, it was decided to incorporate river samples 5 mg / L of these compounds, in order to observe how they might interfere with the disinfection of the water. Thus optimum results are achieved for disinfection systems studied, being efficient ozone oxidant in the disinfection of microorganisms and the removal of humic acids and phenols with short contact times, showing gaps to allow regrowth total coliforms. Advanced oxidation system UV / peroxide were determined as an efficient disinfectant to ensure the absence of volunteers, the passage of time. Also it is concluded that has good yields in removing humic acid and phenols.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Debido al aumento de los estándares de calidad exigidos internacionalmente, así como por una mayor presión sobre la industria mediante legislaciones ambientales más rigurosas, el sector cafetalero está obligado a buscar, a través de la investigación, un sistema adecuado de tratamiento para las aguas residuales generadas en el beneficiado húmedo del café. En este trabajo se evaluó el funcionamiento de la digestión anaerobia para el tratamiento de las aguas residuales de despulpe. Para ello, se utilizaron dos sistemas anaerobios, uno en una etapa (UASB), y otro con separación de fases (2PUASB). Se investigó el efecto en la digestión anaerobia de tres cargas orgánicas volumétricas (OLR) y de las dos configuraciones de reactor usadas. Los valores de OLR de operación en el sistema UASB variaron en un intervalo de 3.6-4.1 kgCOD m-3 d-1, con una tasa de recirculación del efluente de 1.0. El sistema 2PUASB fue alimentado con OLR similares a las que se emplearon en el sistema en una etapa. El reactor de acidificación fue cargado a 11.0 kgCOD m-3 d-1, mientras que en el reactor metanogénico varió en el intervalo de 2.6-4.67 kgCOD m-3 d-1. El uso de reactores UASB en una etapa y en dos fases, bajo las mismas condiciones de operación ya descritas, propiciaron el logro de una eficiencia de degradación de COD total superior al 75% y al 85% para la COD soluble, respectivamente. Sin embargo, el sistema en dos fases mostró mejores resultados en el tratamiento de este tipo de agua residual, no solo en cuanto a eficiencia de eliminación de la carga orgánica contaminante así como una menor concentración de ácidos grasos volátiles (VFA) en el efluente. Obtenidas las mejores condiciones de trabajo, fue evaluada la separación de fases bajo el efecto de la recirculación. Los grupos de fermentaciones producidos fueron similares a los obtenidos en el experimento sin recirculación, indicando que está última no afectó la composición relativa de los VFA del reactor anaerobio, por lo que no cambió el patrón de degradación del residuo. Una tasa de recirculación de 1.0 del efluente del reactor metanogénico al reactor acidogénico mejoró significativamente el proceso, ya que se incrementó la conversión de los VFA (31%), la eliminación de la fracción total y soluble del residuo tratado (6.5%) y la reducción del consumo de alcalinizante (39%); manteniendo similares producciones de metano. El uso de la digestión anaerobia en dos fases demostró una mejora en la estabilidad del proceso y un incremento de la eficiencia de operación y de la producción de metano, respectivamente.Tesis Doctoral Yans Guardia Puebla Abstract ix ABSTRACT Due to the increase of quality standards internationally demanded, as well as for a greater pressure on the industry by means of more rigorous environmental legislations, the coffee sector is forced to search, through the research, an appropriated treatment system for coffee wet wastewaters generated. In this work the performance of the anaerobic digestion for the coffee wet wastewater treatment was evaluated. For it, two anaerobic systems, one in single-stage (UASB), and another with two-phase (2PUASB) were used. The effect in the anaerobic digestion of three organic loading rates (OLR) and of two reactor configurations used was investigated. OLR operation values in UASB system varied in an interval of 3.6-4.1 kgCOD m-3 d-1, with a recycle rate of the effluent of 1.0. 2PUASB system was fed with OLR similar to those that were used in the reactor in a stage. The acidification reactor was loaded to 11.0 kgCOD m-3 d-1, whereas in the methanogenic reactor varied in the interval of 2.6-4.67 kgCOD m-3 d-1. The use of single-stage and two-phase UASB reactors, under the same operation conditions already before described, a total COD removal efficiency of 75% and 85% for the soluble COD removal efficiency, respectively, was achieved. However, two-phase system showed better results in the treatment of this wastewater type, not only as for removal efficiency of loading organic polluting as well as a smaller volatile fatty acid (VFA) concentration in the effluent. Obtained the best work conditions, the two-phase system under the effect of the recycle was evaluated. Fermentations groups produced were similar to those obtained in the experiment without recycle, indicating that it last one do not affect the relative composition of VFA of the anaerobic reactor, for that reason the degradation pattern of the residue does not change. A recycle rate of 1.0 of the effluent of the methanogenic reactor to the acidogenic reactor improved the process significantly, since it was increased the VFA conversion (31%), the removal of total and soluble fraction of the residue treated (6.5%) and the decrease of the alkalinity consumption (39%); maintaining similar methane productions. The use of the two-phase anaerobic digestion demonstrated to an improvement in the stability of the process and an increase of the operation efficiency and methane production, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En este trabajo se llevó a cabo el tratamiento de vinazas mediante dos tecnologías anaerobias. Se dividió en cuatro estudios técnicos. El primero fue el arranque y estabilización del reactor UASB (Upflow Anaerobic Sludge Blanket), en dónde se evaluó la estabilización mediante la eficiencia de remoción de DQO y la granulación del lodo. El segundo estudio evaluó el rendimiento del reactor UASB frente a diferentes Cva. El tercer estudio evaluó el efecto del TRH sobre la eficiencia del reactor UASB, y el cuarto de ellos fue evaluar el rendimiento del RABF (Reactor Anaerobio de Biomasa Fija). El reactor UASB de 2,6 L de capacidad, fue arrancado por lotes, con seis ensayos utilizando vinaza como sustrato. Se obtuvieron eficiencias de remoción en DQO en un rango de 79-91%, en los seis lotes. Se obtuvo formación de gránulos con diámetro (Ø) de 0,85-1,15 mm y un coeficiente de esfericidad (Є) de 0,7-0,77. Se logró la granulación de lodos tras 2 meses de operación. Alcanzada la estabilización del reactor UASB, se siguió una operación en flujo continuo. Las Cva probadas de 1, 2, 4 y 6 gDQO/L.d para el reactor UASB dan una respuesta bastante favorable con respecto al rendimiento del reactor, ya que presento eficiencias de remoción de DQOs del 51 hasta el 76%, eficiencias similares a los reportados por la literatura. En el estudio de TRH se operó con Cva de 6 gDQO/L.d y los TRH fueron de 24, 12 ,5 ,3 y 1 día. El % de eliminación de DQO fue de 51, 60, 57, 60 y 63 % remoción en DQOsoluble, respectivamente. Se alcanzó una producción de biogás máximo de 5.283 ml/d, pero al reducir el TRH se observó una reducción proporcional del volumen total de biogás. El %CH4 contenido en el biogás aumento al disminuir el TRH, reflejando valores de 80 al 92 % de CH4. El RABF con un volumen de 8,2 L, utilizo tubos de plástico corrugado como medio de soporte para las bacterias. Se aplicaron las siguientes Cva; 0,5, 1, 3 y 6 gDQO/L.d. El reactor RABF presento una excelente remoción de la materia orgánica (80% DQOs), una producción de biogás estable, y un contenido en CH4 del biogás muy interesante. Sin embargo, para una Cva superior a 3 gDQO/L.d empezó un comportamiento inesperado de reducción de capacidad. Las condiciones hidrodinámicas del reactor UASB son decisivas para la formación de los gránulos, condición previa para iniciar el flujo continuo. Al operar el reactor UASB en modo continuo, se pudo evaluar las mejores condiciones de operación para este tipo de residuo (vinaza). La Cva de 6 gDQO/L.d para el reactor UASB alimentado con vinaza bruta representa el límite de su capacidad. Sin embargo, al aumentar la Cva se genera una mayor producción de biogás y metano. La eficiencia de remoción de la DQO soluble es independiente del TRH, para una Cva de 6 g DQO/L•d y las condiciones de TRH probadas (24, 12, 5, 3 y 1 días). Los valores de remoción de DQO alcanzados son un poco superior a los valores de biodegradabilidad anaerobia de la vinaza observados de 50 %. De manera general, la reducción del TRH o bien la dilución de la vinaza no presenta un efecto significativo sobre la remoción de la materia orgánica soluble, pero si lo presenta en la remoción de sulfatos reduciendo indirectamente su toxicidad. El soporte termoplástico inoculado en el RABF y alimentado con vinaza bruta, actuó como un filtro, además de obtener buenos resultados en eliminación de DQO, pero dada las dimensiones y la altura del relleno se frena la evacuación del metano. This work was carried out by treatment vinasses with two anaerobic technologies. It was divided into four technical studies. The first was the start up and stabilization Upflow Anaerobic Sludge Blanket (UASB) reactor, where the stability was evaluated by the removal efficiency of COD and sludge granulation. The second study evaluated the performance of the UASB reactor against different OLR. The third study evaluated the effect of HRT on the efficiency of the UASB reactor, and the fourth of which was evaluate the performance Fixed Biomass Anaerobic (FBA) reactor. The UASB reactor of 2,6 L capacity, was started in batch, with six assays using vinasse as substrate. Were obtained removal efficiencies of COD in the range of 79- 91% in the six batches. Forming granules were obtained with a diameter (Ø) of 0,85- 1,15 mm and sphericity coefficient (Є) of 0,7 to 0,77. Sludge granulation was achieved after 2 months of operation. Once stabilization is achieved of the UASB reactor, it was followed by a continuous flow operation. The OLR tested 1, 2, 4 and 6 gCOD/L.d for UASB reactor gives a very favorable response regarding the performance of the reactor, as presented COD5 removal efficiencies of 51 to 76%, similar efficiencies those reported in the literature The HRT study was operated with an OLR of 6 gCOD/L.d and HRT were 24, 12, 5, 3 and 1 day. The removal efficiency was 51, 60, 57, 60 and 63% in soluble COD, respectively. It reached a maximum biogas production of 5.283 ml / d, but by reducing the HRT showed a proportional reduction in the total volume of biogas. The %CH4 content in the biogas increased with decreasing TRH, reflecting values of 80 to 92% of CH4. The FBA reactor with a volume of 8,2 L, used corrugated plastic tubes as carrier for bacteria transportation. The following OLR was applied, 0,5, 1, 3 and 6 gCOD/L.d. The FBA reactor showed an excellent removal of organic matter (80% CODS), a stable biogas production, and CH4 content very interesting. However, for more than 3 gCOD/L.d OLR began with unexpected behavior of capacity reduction. The UASB reactor hydrodynamic conditions are decisive for the formation of the granules, precondition to start the continuous flow. By operating the UASB reactor in continuous mode, it was possible to evaluate the best operating conditions for this type of waste (vinasse). The OLR of 6 gCOD/L.d for the UASB reactor fed with raw vinasse represents the limit of its capacity. However, with increasing OLR creates increased biogas production and methane. The removal efficiency of soluble COD is independent of HRT for OLR of 6 gCOD/L.d and HRT conditions tested (24, 12, 5, 3 and 1 day). COD Removal values achieved are slightly higher than the values of the vinasse anaerobic biodegradability of observed at 50%. Generally, reduction of HRT or vinasse dilution does not present a significant effect on the removal of the soluble organic matter; however if it occurs in the removal of sulfate reducing indirectly its toxicity. The thermoplastic support inoculated in FBA reactor and fed with raw vinasse, acted as a filter, in addition to obtaining good results in COD removal, but given the size and height of the filling slows evacuation of methane.