981 resultados para Échocardiographie Doppler


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exoplanet transit and Doppler surveys discover many binary stars during their operation that can be used to conduct a variety of ancillary science. Specifically, eclipsing binary stars can be used to study the stellar mass-radius relationship and to test predictions of theoretical stellar evolution models. By cross-referencing 24 binary stars found in the MARVELS Pilot Project with SuperWASP photometry, we find two new eclipsing binaries, TYC 0272-00458-1 and TYC 1422-01328-1, which we use as case studies to develop a general approach to eclipsing binaries in survey data. TYC 0272-00458-1 is a single-lined spectroscopic binary for which we calculate a mass of the secondary and radii for both components using reasonable constraints on the primary mass through several different techniques. For a primary mass of M 1 = 0.92 ± 0.1 M sun, we find M 2 = 0.610 ± 0.036 M sun, R 1 = 0.932 ± 0.076 R sun, and R 2 = 0.559 ± 0.102 R sun, and find that both stars have masses and radii consistent with model predictions. TYC 1422-01328-1 is a triple-component system for which we can directly measure the masses and radii of the eclipsing pair. We find that the eclipsing pair consists of an evolved primary star (M 1 = 1.163 ± 0.034 M sun, R 1 = 2.063 ± 0.058 R sun) and a G-type dwarf secondary (M 2 = 0.905 ± 0.067 M sun, R 2 = 0.887 ± 0.037 R sun). We provide the framework necessary to apply this analysis to much larger data sets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fast ignitor scheme for inertial confinement fusion requires forward driving of the critical density surface by light pressure (hole boring) to allow energy deposition close to the dense fuel. The recession velocity of the critical density surface has been observed to be nu/c = 0.015 at an irradiance of 1.0 x 10(19) W cm(-2) at a wavelength of 1.05 micron, in quantitative agreement with modeling. (C) 1996 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Large parts of the periodic table cannot be cooled by current laser-based methods. We investigate whether zero energy fragmentation of laser cooled fluorides is a potential source of ultracold fluorine atoms. We report new ab initio calculations on the lowest electronic states of the BeF diatomic molecule including spin-orbit coupling, the calculated minima for the valence electronic states being within 1 pm of the spectroscopic values. A four colour cooling scheme based on the A2? ? X2S+ transition is shown to be feasible for this molecule. Multi-Reference Configuration Interaction (MRCI) potentials of the lowest energy Rydberg states are reported for the first time and found to be in good agreement with experimental data. A series of multi-pulse excitation schemes from a single rovibrational level of the cooled molecule are proposed to produce cold fluorine atoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare time-domain waveform analysis of second-trimester uterine artery Doppler using the resistance index (RI) with waveform analysis using a mathematical tool known as wavelet transform for the prediction of pre-eclampsia (PE). This was a retrospective, nested case-cohort study of 336 women, 37 of whom subsequently developed PE. Uterine artery Doppler waveforms were analysed using both RI and waveform analysis. The utility of these indices in screening for PE was then evaluated using receiver operating characteristic curves. There were significant differences in uterine artery RI between the PE women and those with normal pregnancy outcome. After wavelet analysis, significant difference in the mean amplitude in wavelet frequency band 4 was noted between the 2 groups. The sensitivity for both Doppler RI and frequency band 4 for the detection of PE at a 10% false-positive rate was 45%. This small study demonstrates the application of wavelet transform analysis of uterine artery Doppler waveforms in screening for PE. Further prospective studies are needed in order to clearly define if this analytical approach to waveform analysis may have the potential to improve the detection of PE by uterine artery Doppler screening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Objective To determine if high umbilical artery Doppler (UAD) pulsatility index (PI) is associated with cardio-vascular (CV) risk-factors in children at age 12 years. Methods We studied 195 children at age 12 years who had had in-utero UAD studies performed at 28 weeks gestation. The children were grouped according to whether their umbilical Doppler PI was high (indicating poor feto-placental circulation) or normal. At age 12 years we assessed CV risk factors, including anthropometric measures, blood pressure, pulse wave velocity (a measure of arterial compliance), cardio-respiratory fitness and homocysteine and cholesterol serum levels. Results Compared with children with a normal UAD PI (N=88), the children (N=107) with high UAD PI had higher resting pulse rate (p=0.04), higher pulse wave velocity (p=0.046), higher serum homocysteine levels (p=0.032) and reduced arterial compliance (7.58 v 8.50 m/sec, p=0.029) using univariate analysis. These differences were not present when adjusting for cofounders was modelled. Conclusion High PI on UAD testing in-utero may be associated with increased likelihood of some cardio-vascular risk factors at age 12-years but confounding variables may be as important. Our study raises possible long-term benefits of in-utero UAD measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A counterintuitive scheme to produce ultracold hydrogen via fragmentation of laser cooled diatomic hydrides is presented where the final atomic H temperature is inversely proportional to the mass of the molecular parent. In addition, the critical density for formation of a Bose-Einstein condensate (BEC) at a fixed temperature is reduced by a factor (mH/mMH)3/2 over directly cooled hydrogen atoms. The narrow Feshbach resonances between a S01 atom and hydrogen are well suited to a tiny center of mass energy release necessary during fragmentation. With the support of ab initio quantum chemistry, it is demonstrated that BaH is an ideal diatomic precursor that can be laser cooled to a Doppler temperature of ∼26μK with just two rovibronic transitions, the simplest molecular cooling scheme identified to date. Preparation of a hydrogen atom gas below the critical BEC temperature Tc is feasible with present cooling technology, with optical pulse control of the condensation process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wavelet entropy assesses the degree of order or disorder in signals and presents this complex information in a simple metric. Relative wavelet entropy assesses the similarity between the spectral distributions of two signals, again in a simple metric. Wavelet entropy is therefore potentially a very attractive tool for waveform analysis. The ability of this method to track the effects of pharmacologic modulation of vascular function on Doppler blood velocity waveforms was assessed. Waveforms were captured from ophthalmic arteries of 10 healthy subjects at baseline, after the administration of glyceryl trinitrate (GTN) and after two doses of N(G)-nitro-L-arginine-methyl ester (L-NAME) to produce vasodilation and vasoconstriction, respectively. Wavelet entropy had a tendency to decrease from baseline in response to GTN, but significantly increased after the administration of L-NAME (mean: 1.60 ± 0.07 after 0.25 mg/kg and 1.72 ± 0.13 after 0.5 mg/kg vs. 1.50 ± 0.10 at baseline, p < 0.05). Relative wavelet entropy had a spectral distribution from increasing doses of L-NAME comparable to baseline, 0.07 ± 0.04 and 0.08 ± 0.03, respectively, whereas GTN had the most dissimilar spectral distribution compared with baseline (0.17 ± 0.08, p = 0.002). Wavelet entropy can detect subtle changes in Doppler blood velocity waveform structure in response to nitric-oxide-mediated changes in arteriolar smooth muscle tone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine whether an elevated fetal umbilical artery Doppler (UAD) pulsatility index (PI) at 28 weeks' gestation, in the absence of fetal growth restriction (FGR) and prematurity, is associated with adverse neurocognitive outcome in children aged 12 years.

METHODS: Prospective cohort study, comparing children with a normal fetal UAD PI (<90th centile) (n=110) and those with an elevated PI (≥90th centile) (n=40). UAD was performed at 28, 32 and 34 weeks gestation. At 12 years of age, all children were assessed under standardised conditions at Queen's University, Belfast, UK to determine cognitive and behavioural outcomes using the British Ability Score-II and Achenbach Child Behavioural Checklist Parent Rated Version under standardised conditions. Regression analysis was performed, controlling for confounders such as gender, socioeconomic status and age at assessment.

RESULTS: The mean age of follow-up was 12.4 years (±0.5 SD) with 44% of children male (n=63). When UAD was assessed at 28 weeks, the elevated fetal UAD group had lower scores in cognitive assessments of information processing and memory. Parameters included (1) recall of objects immediate verbal (p=0.002), (2) delayed verbal (p=0.008) and (3) recall of objects immediate spatial (p=0.0016). There were no significant differences between the Doppler groups at 32 or 34 weeks' gestation.

CONCLUSIONS: An elevated UAD PI at 28 weeks' gestation in the absence of FGR or prematurity is associated with lower scores of declarative memory in children aged 12 years. A potential explanation for this is an element of placental insufficiency in the presence of the appropriately grown fetus, which affects the development of the fetal hippocampus and information processing and memory long-term. These findings, however, had no impact on overall academic ability, mental processing and reasoning or overall behavioural function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluation of blood-flow Doppler ultrasound spectral content is currently performed on clinical diagnosis. Since mean frequency and bandwidth spectral parameters are determinants on the quantification of stenotic degree, more precise estimators than the conventional Fourier transform should be seek. This paper summarizes studies led by the author in this field, as well as the strategies used to implement the methods in real-time. Regarding stationary and nonstationary characteristics of the blood-flow signal, different models were assessed. When autoregressive and autoregressive moving average models were compared with the traditional Fourier based methods in terms of their statistical performance while estimating both spectral parameters, the Modified Covariance model was identified by the cost/benefit criterion as the estimator presenting better performance. The performance of three time-frequency distributions and the Short Time Fourier Transform was also compared. The Choi-Williams distribution proved to be more accurate than the other methods. The identified spectral estimators were developed and optimized using high performance techniques. Homogeneous and heterogeneous architectures supporting multiple instruction multiple data parallel processing were essayed. Results obtained proved that real-time implementation of the blood-flow estimators is feasible, enhancing the usage of more complex spectral models on other ultrasonic systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work described here is part of a research program aiming to increase the sensitivity to disease detection using Doppler ultrasound by reducing the effects to the measurement procedure on the estimation of blood velocity and detection of flow disturbance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os sinais de fluxo sanguíneo são sinais aleatórios que, além de variarem de individuo para individuo, variam também consoante o ciclo cardíaco em análise. Sendo o diagnóstico de patologias cardiovasculares fortemente baseado em sinais de ultrassom Doppler representados em forma de espectrograma, e tendo em consideração que o ruído do tipo speckle é parte integrante dos sinais ultrassónicos, torna-se vital a pesquisa de métodos de eliminação desse tipo de ruído e de caracterização precisa dos parâmetros desses sinais biomédicos por forma a melhorar a qualidade do diagnóstico clínico. Com esta tese pretende-se desenvolver uma ferramenta computacional que possibilite a extração automática dos parâmetros pico sistólico, fim de diástole e de outros eventos clinicamente relevantes de sinais Doppler de fluxo sanguíneo, com especial atenção ao sinal proveniente da artéria carótida. Esta investigação vem na continuidade de um projeto realizado anteriormente no Grupo de Processamento de Sinal Biomédico da Universidade do Algarve, no qual foi desenvolvido um sistema de redução de ruído de espectrogramas Doppler. Este sistema de remoção de ruído será aqui aplicado e melhorado. Para a deteção e extração automática de parâmetros clínicos, foi desenvolvido um algoritmo que recebe um sinal de Doppler e que tem como saída o espectrograma livre de ruído e os valores dos parâmetros clínicos calculados. O algoritmo desenvolvido está dividido em três partes principais. A primeira, consiste na transformada do sinal para os domínios tempo-frequência para a criação do espectrograma e na aplicação de uma metodologia de remoção do ruído do tipo speckle do espectrograma. A fase seguinte é a criação de um sinal bidimensional a partir do espectrograma, o qual é criado para possibilitar a sua caraterização. Por último, desenvolveu-se uma fase dedicada à caracterização do sinal, tendo como principais funções a deteção dos eventos clínicos de pico sistólico, fim de diástole, índice de pulsação, índice de resistência e ratio sístole-diástole. A refinação de atuação de cada uma das três partes mencionadas pode ser ajustada pelo utilizador, tendo para o efeito sido desenvolvido uma interface gráfica na qual a interação do utilizador com o programa global é facilitada. Versatilidade e eficácia do algoritmo desenvolvido foram demonstradas pelos resultados obtidos com três sinais de Doppler de diferentes origens: um de origem clínica, um sinal de fluxo em artéria carótida simulado experimentalmente recorrendo a phantoms, e um sinal de fluxo simulado computacionalmente. Para cada um destes sinais são apresentados os valores das variáveis considerados preferenciais para o ajuste ao respetivo sinal e os respetivos espetros de ruído reduzido. Os resultados da extração automática dos parâmetros clínicos dos três sinais, comprovou a utilidade clínica do algoritmo desenvolvido.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper compares a carrier tracking scenario when a received Global Positioning System (GPS) signal has low Doppler frequency. It is shown that if the Numerically Controlled Oscillator (NCO) is quantized to 1 bit, the carrier tracking loop is unable to keep track of the incoming signal which leaves the tracking loop oscillating between the upper and lower bounds of the tracking loop bandwidth. One way of overcoming this problem is presented and compared with another existing solution, found in the literature, providing comparative results from the use of real-recorded off the air GPS L1 signals. Results show that the proposed method performs better tracking performance compared with the existing solution which it requires much less hardware complexity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enthesitis is the hallmark of spondyloarthritis and is observed in all subtypes. Namely, a wide information on spondyloarthritis abnormalities, including synovitis, bursitis, tendinitis, enthesitis and cortical bone abnormalities (erosions and enthesophytes), can be efficiently perceived by ultrasound power Doppler. Furthermore, several studies on imaging of enthesis showed that imaging techniques are better than clinical examination to detect pathology at asymptomatic enthesis. Vascularized enthesitis detected by ultrasound power Doppler appears to be a valuable diagnostic tool to confirm spondyloarthritis diagnosis. This article focuses on the validity and reliability of ultrasound enthesitis assessment in the management of spondyloarthritis patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: Enthesitis is the hallmark of spondyloarthritis (SpA), and is observed in all subtypes. Wide information on SpA abnormalities, including synovitis, tendinitis and enthesitis, can be efficiently perceived by Doppler ultrasound. Furthermore, several studies on imaging of enthesis showed that imaging techniques are better than clinical examination to detect enthesis alterations; and vascularized enthesitis detected by Doppler ultrasound appears to be a valuable diagnostic tool to confirm SpA diagnosis. However, data published until now concerning entheseal elementary alterations that characterize SpA enthesitis (enthesis inflammatory activity) or enthesopathy (permanent structural changes) reflect rather the authors’ empiric opinion than a methodological validation process. In this sense it seems crucial to identify elementary entheseal lesions associated with activity or damage, in order to improve monitoring and treatment response in SpA patients. The development of better assessment tools is today a challenge and a need in SpA. The first study of this thesis focused on the analysis of the reliability of inter-lector and inter-ultrasonography equipment of Madrid sonography enthesitis index (MASEI). Fundamental data for the remaining unrolling project validity. In the second and third studies we concerned about two entheseal elemental lesions: erosions and bursa. In literature erosions represent a permanent structural damage, being useful for monitoring joint injury, disease activity and therapeutic response in many rheumatic diseases; and to date, this concept has been mostly applied in rheumatoid arthritis (RA). Unquestionably, erosion is a tissue-related damage and a structural change. However, the hypothesis that we decided to test was if erosions represent a permanent structural change that can only grow and worsen over time, as occurs in RA, or a transitory alteration. A longitudinal study of early SpA patients was undertaken, and the Achilles enthesis was used as a model. Our results strongly suggested that previously detected erosions could disappear during the course of the disease, being consistent with the dynamic behavior of erosion over time. Based on these striking results it seems reasonable to suggest that the new-bone formation process in SpA could be associated with the resolution of cortical entheseal erosion over time. These results could also be in agreement with the apparent failure of anti-tumor necrosis factor (TNF) therapies to control bone proliferation in SpA; and with the relation of TNF-α, Dickkopf-related protein 1 (Dkk-1) and the regulatory molecule of the Wnt signaling pathway in the bone proliferation in SpA. In the same model, we then proceeded to study the enthesis bursa. Interestingly, the Outcome Measures in Rheumatology Clinical Trials (OMERACT) enthesopathy definition does not include bursa as an elementary entheseal lesion. Nonetheless, bursa was included in 46% of the enthesis studies in a recently systematic literature review, being in agreement with the concept of “synovio-entheseal complex” that includes the link between enthesitis and osteitis in SpA. It has been clarified in recent data that there is not only a close functional integration of the enthesis with the neighboring bone, but also a connection between enthesitis and synovitis. Therefore, we tried to assess the prevalence and relevance of the bursa-synovial lesion in SpA. Our findings showed a significant increase of Achilles bursa presence and thickness in SpA patients compared to controls (healthy/mechanical controls and RA controls). These results raise awareness to the need to improve the enthesopathy ultrasonographic definition. In the final work of this thesis, we have explored new perspectives, not previously reported, about construct validity of enthesis ultrasound as a possible activity outcome in SpA. We performed a longitudinal Achilles enthesis ultrasound study in patients with early SpA. Achilles ultrasound examinations were performed at baseline, six- and twelve-month time periods and compared with clinical outcome measures collected at basal visit. Our results showed that basal erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) are higher in patients with Doppler signal in enthesis, and even that higher basal ESR, CRP and Ankylosing Spondylitis Disease Activity Score (ASDAS) predicted a higher Doppler signal (an ultrasound alteration accepted as representative of inflammation) six months later. Patients with very high disease activity assessed by ASDAS (>3.5) at baseline had significantly higher Achilles total ultrasound score verified at the same time; and ASDAS <1.3 predicted no Doppler signal at six and twelve months. This seems to represent a connection between classical biomarkers and clinical outcomes associated with SpA activity and Doppler signal, not only at the same time, but also for the following months. Remarkably, patients with inactive disease (ASDAS < 1.3) at baseline had no Doppler signal at six and twelve months. These findings reinforce the potential use of ultrasound related techniques for disease progression assessment and prognosis purposes. Intriguingly, Ankylosing Spondylitis Disease Activity Index (BASDAI) didn’t show significant differences between different cut-offs concerning ultrasound lesions or Doppler signal, while verified with ASDAS. These results seem to indicate that ASDAS reflects better than BASDAI what happens in the enthesis. The work herein discussed clearly shows the potential utility of ultrasound in enthesis assessment in SpA patients, and can be important for the development of ultrasound activity and structural damage scores for diagnosis and monitoring purposes. Therefore, local promotion of this technique constitutes a medical intervention that is worth being tested in SpA patients for diagnosis, monitoring and prognosis purposes.