897 resultados para structured wall pipe
Resumo:
A second-order closure is developed for predicting turbulent flows of viscoelastic fluids described by a modified generalised Newtonian fluid model incorporating a nonlinear viscosity that depends on a strain-hardening Trouton ratio as a means to handle some of the effects of viscoelasticity upon turbulent flows. Its performance is assessed by comparing its predictions for fully developed turbulent pipe flow with experimental data for four different dilute polymeric solutions and also with two sets of direct numerical simulation data for fluids theoretically described by the finitely extensible nonlinear elastic - Peterlin model. The model is based on a Newtonian Reynolds stress closure to predict Newtonian fluid flows, which incorporates low Reynolds number damping functions to properly deal with wall effects and to provide the capability to handle fluid viscoelasticity more effectively. This new turbulence model was able to capture well the drag reduction of various viscoelastic fluids over a wide range of Reynolds numbers and performed better than previously developed models for the same type of constitutive equation, even if the streamwise and wall-normal turbulence intensities were underpredicted.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The electromechanical impedance (EMI) technique has been successfully used in structural health monitoring (SHM) systems on a wide variety of structures. The basic concept of this technique is to monitor the structural integrity by exciting and sensing a piezoelectric transducer, usually a lead zirconate titanate (PZT) wafer bonded to the structure to be monitored and excited in a suitable frequency range. Because of the piezoelectric effect, there is a relationship between the mechanical impedance of the host structure, which is directly related to its integrity, and the electrical impedance of the PZT transducer, obtained by a ratio between the excitation and the sensing signals.This work presents a study on damage (leaks) detection using EMI based method. Tests were carried out in a rig water system built in a Hydraulic Laboratory for different leaks conditions in a metallic pipeline. Also, it was evaluated the influence of the PZT position bonded to the pipeline. The results show that leaks can effectively be detected using common metrics for damage detection such as RMSD and CCDM. Further, it was observed that the position of the PZT bonded to the pipes is an important variable and has to be controlled.
Resumo:
Acoustic techniques have been used for many years to find and locate leaks in buried water distribution systems. Hydrophones and accelerometers are typically used as sensors. Although geophones could be used as well, they are not generally used for leak detection. A simple acoustic model of the pipe and the sensors has been proposed previously by some of the authors of this paper, and their model was used to explain some of the features observed in measurements. However, simultaneous measurements of a leak using all three sensor-types in controlled conditions for plastic pipes has not been reported to-date and hence they have not yet been compared directly. This paper fills that gap in knowledge. A set of measurements was made on a bespoke buried plastic water distribution pipe test rig to validate the previously reported analytical model. There is qualitative agreement between the experimental results and the model predictions in terms of the differing filtering properties of the pipe-sensor systems. A quality measure for the data is also presented, which is the ratio of the bandwidth over which the analysis is carried out divided by the centre frequency of this bandwidth. Based on this metric, the accelerometer was found to be the best sensor to use for the test rig described in this paper. However, for a system in which the distance between the sensors is large or the attenuation factor of the system is high, then it would be advantageous to use hydrophones, even though they are invasive sensors.
Resumo:
This article consists in a discourse analysis of the feature film in animation Wall.e produced by Pixar in association to Disney in 2008. Pixar has been known to produce films that contain various discursive levels, making its products appealing not only for children, but also for adults. However, Wall-e proves to be a masterpiece in Pixar carrier, because it is the one which focuses on the analysis and critique of contemporary society associated with technological development. For this, the plot has as its starting point the question of sustainability and unbridled consumerism. But the film expands the debate, tracing the relationship between technology and humanity, discussing how one affects the other. The project therefore aims to show how the animation works such concepts and constructs his discourse. To this end, the work seeks to identify the signs that make up the discourse and draw the intertextuality between WALL.E and other works that also discuss the same elements such as Stanley Kubrick‟s 2001 - A Space Odyssey (1968)
Resumo:
Endometriosis is a continuous and progressive disease with a poorly understood aetiology, pathophysiology and natural history. This study evaluated the histological differences between eutopic and ectopic endometria (abdominal wall endometriosis) and the expression of mast cell proteases (tryptase and chymase), annexin A1 (ANXA1) and formyl peptide receptor 1 (FPR1). Ectopic endometrium from 18 women with abdominal wall endometriosis and eutopic endometrium from 10 women without endometriosis were obtained. The endometrial samples were analysed by histopathology, immunohistochemistry and ultrastructural immunogold labeling to determine mast cell heterogeneity (tryptase and chymase positive cells) and the expression levels of ANXA1 and FPR1. Histopathological analysis of the endometriotic lesions showed a glandular pattern of mixed differentiation and an undifferentiated morphology with a significant influx of inflammatory cells and a change in mast cell heterogeneity, as evidenced by a significant increase in the number of chymase-positive cells and endogenous chymase expression. The undifferentiated glandular pattern of endometriotic lesions was positively associated with a marked increase and co-localization of ANXA1 and FPR1 in the epithelial cells. In conclusion, the co-upregulated expression of mast cell chymase and ANXA1–FPR1 system in ectopic endometrium suggests their involvement in the development of endometriotic lesions.
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
The aim of this study was to evaluate the efficacy and safety of traumatic orbital defect reconstruction with titanium mesh. A retrospective study was made. Evaluations were made after a minimum postoperative follow-up of 12 months, looking for the main complications. Twenty-four patients were included in this evaluation; 19 were male (79.1%) and 5 (20.8%) were female. The main injury etiology was vehicle accidents (50%) followed by other causes. Fourteen patients (58.3%) presented orbital floor fractures, and 10 had more than one wall fractured (41.6%). Permanent infraorbital nerve hypoesthesia was observed in two patients (8.3%), enophthalmos occurred in five patients (20.8%), and exophthalmos was found in two patients (8.3%). Four patients (16.6%) still presented evidence of residual prolapsed intraorbital content, and one of those needed further surgical correction; sinusitis occurred in one patient (4.1%). Titanium mesh is a reliable option for orbital reconstruction, despite some complications found in this sample.
Resumo:
This study aimed to characterize and evaluate the performance of four models self-compensating drippers commonly used in drip irrigation systems in Brazil. To perform the study it was taking a sample of 25 emitters of each model. Evaluating their tubes (b) coefficient of manufacturing variation (c) wall thickness, (d) characteristic equation of the dripper, (e) internal diameter of the pipe, (f) spacing between emitters, (g) resistance water pressure at ambient temperature and to 40°C and (h) the tensile strength of the pipe with tension of 160 N and 180 N. The analysis showed variation coefficient of less than 0.045 for all manufacturing drippers (0.07 is maximum according to ABNT NBR ISO 9261). The exponents x of the equation pressure versus discharge ranged from 0.0082 to 0.0691 classifying them as self-compensating. From the results obtained it is clear that the tested products which are used in Brazil and used by irrigators had a satisfactory hydraulic performance in accordance with the standard.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Given the importance the concept of productive efficiency has on analyzing the human development process, which is complex and multidimensional, this study conducts a literature review on the research works that have used the data envelopment analysis (DEA) to measure and analyze the development process. Therefore, we researched the databases of Scopus and Web of Science, and considered the following analysis dimensions: bibliometrics, scope, DEA models and extensions used, interfaces with other techniques, units analyzed and depth of analysis. In addition to a brief summary, the main gaps in each analysis dimension were assessed, which may serve to guide future researches. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In water distribution systems, old metallic pipes have been replaced by plastic pipes due to their deterioration over time. Although acoustic methods are effective in finding leaks in metallic pipes, they have been found to be problematic when applied to plastic pipes due to the high damping within the pipe wall and the surrounding medium. This is responsible for the leak signal not traveling long distances. Moreover, the leak energy in plastic pipes is generally located at a narrow frequency range located at low frequencies. However, the presence of resonances can narrow even more this frequency range. In order to minimise the influence of background noise and resonances on the calculation of the time delay estimate, band-pass filters are often used to supress undesirable frequency components of the noise. The objective of this paper is to investigate the influence of resonances in the pipe system (pipe, valves, connections and hydrants), on the time delay estimate calculated using acoustic signals. Analytical models and actual leak data collected in a bespoke rig located in the United Kingdom are used to investigate this feature.