829 resultados para reliability of supply
Resumo:
Introduction: Ankle arthropathy is associated with a decreased motion of the ankle-hindfoot during ambulation. Ankle arthrodesis was shown to result in degeneration of the neighbour joints of the foot. Inversely, total ankle arthroplasty conceptually preserves the adjacent joints because of the residual mobility of the ankle but this has not been demonstrated yet in vivo. It has also been reported that degenerative ankle diseases, and even arthrodesis, do not result in alteration of the knee and hip joints. We present the preliminary results of a new approach of this problem based on ambulatory gait analysis. Patients and Methods: Motion analysis of the lower limbs was performed using a Physilog® (BioAGM, CH) system consisting of three-dimensional (3D) accelerometer and gyroscope, coupled to a magnetic system (Liberty©, Polhemus, USA). Both systems have been validated. Three groups of two patients were included into this pilot study and compared to healthy subjects (controls) during level walking: patients with ankle osteoarthritis (group 1), patients treated by ankle arthrodesis (group 2), patients treated by total ankle prosthesis (group 3). Results: Motion patterns of all analyzed joints over more than 20 gait cycles in each subject were highly repeatable. Motion amplitude of the ankle-hindfoot in control patients was similar to recently reported results. Ankle arthrodesis limited the motion of the ankle-hindfoot in the sagittal and horizontal planes. The prosthetic ankle allowed a more physiologic movement in the sagittal plane only. Ankle arthritis and its treatments did not influence the range of motion of the knee and hip joint during stance phase, excepted for a slight decrease of the hip flexion in groups 1 and 2. Conclusion: The reliability of the system was shown by the repeatability of the consecutive measurements. The results of this preliminary study were similar to those obtained through laboratory gait analysis. However, our system has the advantage to allow ambulatory analysis of 3D kinematics of the lower limbs outside of a gait laboratory and in real life conditions. To our knowledge this is a new concept in the analysis of ankle arthropathy and its treatments. Therefore, there is a potential to address specific questions like the difficult comparison of the benefits of ankle arthroplasty versus arthrodesis. The encouraging results of this pilot study offer the perspective to analyze the consequences of ankle arthropathy and its treatments on the biomechanics of the lower limbs ambulatory, in vivo and in daily life conditions.
Resumo:
Gene expression data from microarrays are being applied to predict preclinical and clinical endpoints, but the reliability of these predictions has not been established. In the MAQC-II project, 36 independent teams analyzed six microarray data sets to generate predictive models for classifying a sample with respect to one of 13 endpoints indicative of lung or liver toxicity in rodents, or of breast cancer, multiple myeloma or neuroblastoma in humans. In total, >30,000 models were built using many combinations of analytical methods. The teams generated predictive models without knowing the biological meaning of some of the endpoints and, to mimic clinical reality, tested the models on data that had not been used for training. We found that model performance depended largely on the endpoint and team proficiency and that different approaches generated models of similar performance. The conclusions and recommendations from MAQC-II should be useful for regulatory agencies, study committees and independent investigators that evaluate methods for global gene expression analysis.
Resumo:
BACKGROUND: The Complete Arabidopsis Transcript MicroArray (CATMA) initiative combines the efforts of laboratories in eight European countries 1 to deliver gene-specific sequence tags (GSTs) for the Arabidopsis research community. The CATMA initiative offers the power and flexibility to regularly update the GST collection according to evolving knowledge about the gene repertoire. These GST amplicons can easily be reamplified and shared, subsets can be picked at will to print dedicated arrays, and the GSTs can be cloned and used for other functional studies. This ongoing initiative has already produced approximately 24,000 GSTs that have been made publicly available for spotted microarray printing and RNA interference. RESULTS: GSTs from the CATMA version 2 repertoire (CATMAv2, created in 2002) were mapped onto the gene models from two independent Arabidopsis nuclear genome annotation efforts, TIGR5 and PSB-EuGène, to consolidate a list of genes that were targeted by previously designed CATMA tags. A total of 9,027 gene models were not tagged by any amplified CATMAv2 GST, and 2,533 amplified GSTs were no longer predicted to tag an updated gene model. To validate the efficacy of GST mapping criteria and design rules, the predicted and experimentally observed hybridization characteristics associated to GST features were correlated in transcript profiling datasets obtained with the CATMAv2 microarray, confirming the reliability of this platform. To complete the CATMA repertoire, all 9,027 gene models for which no GST had yet been designed were processed with an adjusted version of the Specific Primer and Amplicon Design Software (SPADS). A total of 5,756 novel GSTs were designed and amplified by PCR from genomic DNA. Together with the pre-existing GST collection, this new addition constitutes the CATMAv3 repertoire. It comprises 30,343 unique amplified sequences that tag 24,202 and 23,009 protein-encoding nuclear gene models in the TAIR6 and EuGène genome annotations, respectively. To cover the remaining untagged genes, we identified 543 additional GSTs using less stringent design criteria and designed 990 sequence tags matching multiple members of gene families (Gene Family Tags or GFTs) to cover any remaining untagged genes. These latter 1,533 features constitute the CATMAv4 addition. CONCLUSION: To update the CATMA GST repertoire, we designed 7,289 additional sequence tags, bringing the total number of tagged TAIR6-annotated Arabidopsis nuclear protein-coding genes to 26,173. This resource is used both for the production of spotted microarrays and the large-scale cloning of hairpin RNA silencing vectors. All information about the resulting updated CATMA repertoire is available through the CATMA database http://www.catma.org.
Resumo:
AIM: The aim of this study was to interpret and validate a French version of the Oswestry disability index (ODI), using a cross-cultural validation method. The validity and reliability of the questionnaire was assessed in order to ensure the psychometric characteristics. METHOD: The cross-cultural validation was carried out according to Beaton's methodology. The study was conducted with 41 patients suffering from low back pain. The correlation between the ODI and the Roland-Morris disability questionnaire (RMDQ), the medical outcome survey short form-36 (MOS SF-36) and a pain visual analogical scale (VAS) was assessed. RESULTS: The validity of the Oswestry questionnaire was studied using the Cronbach Alpha coefficient calculation: 0.87 (n=36). The significant correlation between the ODI and RMDQ was 0.8 (P<0.001, n=41) and 0.71 (P<0.001, n=36) for the pain VAS. The correlation between the ODI and certain subscales (physical functioning 0.7 (P<0.001, n=41), physical role 0.49 et bodily pain 0.73 (P<0.001, n=41)) of the MOS SF-36 were equally significant. The reproducibility of the ODI was calculated using the Wilcoxon matched pairs test: there was no significant difference for eight out of ten sections or for the final score. CONCLUSION: This French translation of the ODI should be considered as valid and reliable. It should be used for any future clinical studies carried out using French language patients. Complimentary studies must be completed in order to assess its sensitivity to change in the event of any modifications in the patients functional capacity.
Resumo:
Topological indices have been applied to build QSAR models for a set of 20 antimalarial cyclic peroxy cetals. In order to evaluate the reliability of the proposed linear models leave-n-out and Internal Test Sets (ITS) approaches have been considered. The proposed procedure resulted in a robust and consensued prediction equation and here it is shown why it is superior to the employed standard cross-validation algorithms involving multilinear regression models
Resumo:
Given the important role of the shoulder sensorimotor system in shoulder stability, its assessment appears of interest. Force platform monitoring of centre of pressure (CoP) in upper-limb weight-bearing positions is of interest as it allows integration of all aspects of shoulder sensorimotor control. This study aimed to determine the feasibility and reliability of shoulder sensorimotor control assessment by force platform. Forty-five healthy subjects performed two sessions of CoP measurement using Win-Posturo(®) Medicapteurs force platform in an upper-limb weight-bearing position with the lower limbs resting on a table to either the anterior superior iliac spines (P1) or upper patellar poles (P2). Four different conditions were tested in each position in random order: eyes open or eyes closed with trunk supported by both hands and eyes open with trunk supported on the dominant or non-dominant side. P1 reliability values were globally moderate to high for CoP length, CoP velocity and CoP standard deviation (SD), standard error of measurement ranged from 6·0% to 26·5%, except for CoP area. P2 reliability values were globally low and not clinically acceptable. Our results suggest that shoulder sensorimotor control assessment by force platform is feasible and has good reliability in upper-limb weight-bearing positions when the lower limbs are resting on a table to the anterior superior iliac spines. CoP length, CoP velocity and CoP SD velocity appear to be the most reliable variables.
Resumo:
This study examined the validity and reliability of the French version of two observer-rated measures developed to assess cognitive errors (cognitive errors rating system [CERS]) [6] and coping action patterns (coping action patterns rating system [CAPRS]) [22,24]. The CE measures 14 cognitive errors, broken down according to their valence positive or negative (see the definitions by A.T. Beck), and the CAP measures 12 coping categories, based on an comprehensive review literature, each broken down into three levels of action (affective, behavioural, cognitive). Thirty (N = 30) subjects recruited in a community sample participated in the study. They were interviewed according to a standardized clinical protocol: these interviews were transcribed and analysed with both observer-rated systems. Results showed that the inter-rater reliability of the two measures is good and that their internal validity is satisfactory, due to a non-significant canonical correlation between CAP and CE. With regard to discriminant validity, we found a non-significant canonical correlation between CAPRS and CISS, one of most widely used self-report questionnaire measuring coping. The same can be said for the correlation with a self-report questionnaire measuring symptoms (SCL-90-R). These results confirm the absence of confounds in the assessment of cognitive errors and of coping as assessed by these observer-rated scales and add an argument in favour of the French validation of the CE-CAP rating scales. (C) 2010 Elsevier Masson SAS. All rights reserved.
Resumo:
The purpose of this paper is to describe the development and to test the reliability of a new method called INTERMED, for health service needs assessment. The INTERMED integrates the biopsychosocial aspects of disease and the relationship between patient and health care system in a comprehensive scheme and reflects an operationalized conceptual approach to case mix or case complexity. The method is developed to enhance interdisciplinary communication between (para-) medical specialists and to provide a method to describe case complexity for clinical, scientific, and educational purposes. First, a feasibility study (N = 21 patients) was conducted which included double scoring and discussion of the results. This led to a version of the instrument on which two interrater reliability studies were performed. In study 1, the INTERMED was double scored for 14 patients admitted to an internal ward by a psychiatrist and an internist on the basis of a joint interview conducted by both. In study 2, on the basis of medical charts, two clinicians separately double scored the INTERMED in 16 patients referred to the outpatient psychiatric consultation service. Averaged over both studies, in 94.2% of all ratings there was no important difference between the raters (more than 1 point difference). As a research interview, it takes about 20 minutes; as part of the whole process of history taking it takes about 15 minutes. In both studies, improvements were suggested by the results. Analyses of study 1 revealed that on most items there was considerable agreement; some items were improved. Also, the reference point for the prognoses was changed so that it reflected both short- and long-term prognoses. Analyses of study 2 showed that in this setting, less agreement between the raters was obtained due to the fact that the raters were less experienced and the scoring procedure was more susceptible to differences. Some improvements--mainly of the anchor points--were specified which may further enhance interrater reliability. The INTERMED proves to be a reliable method for classifying patients' care needs, especially when used by experienced raters scoring by patient interview. It can be a useful tool in assessing patients' care needs, as well as the level of needed adjustment between general and mental health service delivery. The INTERMED is easily applicable in the clinical setting at low time-costs.
Resumo:
This paper focuses on the analysis of the economic impact that sectorial total factor productivity – or valued added - gains have on two regional Spanish economies (Catalonia and Extremadura). In particular it is studied the quantitative effect that each sector’s valued added injections has on household welfare (real disposable income), on the consumption price indices and factor relative prices, on real production (GDP) and on the government and foreign net income. To do that, we introduce the concept of supply multiplier. The analytical approach consists of a computable general equilibrium model, in which it is assumed perfect competition and cleared markets of goods and factors. All the parameters and exogenous variables of the model are calibrated by means of two social accounting matrices, one for each region under study. The results allow identifying those sectors with the greatest multipliers impact on consumer welfare as the key sectors in the regional economies. Keywords: efficiency gains, supply multipliers, key sectors, computable general equilibrium. JEL Classification: C68, R13.
Resumo:
A significant part of daily energy expenditure may be attributed to non-exercise activity thermogenesis and exercise activity thermogenesis. Automatic recognition of postural allocations such as standing or sitting can be used in behavioral modification programs aimed at minimizing static postures. In this paper we propose a shoe-based device and related pattern recognition methodology for recognition of postural allocations. Inexpensive technology allows implementation of this methodology as a part of footwear. The experimental results suggest high efficiency and reliability of the proposed approach.
Resumo:
OBJECTIVE: Evaluation of a French translation of the Addiction Severity Index (ASI) in 100 (78 male) alcoholic patients. METHOD: Validity of the instrument was assessed by measuring test-retest and interrater reliability, internal consistency and convergence and discrimination between items and scales. Concurrent validity was assessed by comparing the scores from the ASI with those obtained from three other clinimetric instruments. RESULTS: Test-retest reliability of ASI scores (after a 10-day interval) was good (r = 0.63 to r = 0.95). Interrater reliability was evaluated using six video recordings of patient interviews. Severity ratings assigned by six rates were significantly different (p < .05), but 72% of the ratings assigned by those who viewed the videos were within two points of the interviewer's severity ratings. Cronbach alpha coefficient of internal consistency varied from 0.58 to 0.81 across scales. The average item-to-scale convergent validity (r value) was 0.49 (range 0.0 to 0.84) for composite scores and 0.35 (range 0.00 to 0.68) for severity ratings, whereas discriminant validity was 0.11 on average (range-0.19 to 0.46) for composite scores and 0.12 (range-0.20 to 0.52) for severity ratings. Finally, concurrent validity with the following instruments was assessed: Severity of Alcoholism Dependence Questionnaire (40% shared variance with ASI alcohol scale), Michigan Alcoholism Screening Test (2% shared variance with ASI alcohol scale) and Hamilton Depression Rating Scale (31% shared variance with ASI psychiatric scale). CONCLUSIONS: The Addiction Severity Index covers a large scope of problems encountered among alcoholics and quantifies need for treatment. This French version presents acceptable criteria of reliability and validity.
Resumo:
Executive Summary Electricity is crucial for modern societies, thus it is important to understand the behaviour of electricity markets in order to be prepared to face the consequences of policy changes. The Swiss electricity market is now in a transition stage from a public monopoly to a liberalised market and it is undergoing an "emergent" liberalisation - i.e. liberalisation taking place without proper regulation. The withdrawal of nuclear capacity is also being debated. These two possible changes directly affect the mechanisms for capacity expansion. Thus, in this thesis we concentrate on understanding the dynamics of capacity expansion in the Swiss electricity market. A conceptual model to help understand the dynamics of capacity expansion in the Swiss electricity market is developed an explained in the first essay. We identify a potential risk of imports dependence. In the second essay a System Dynamics model, based on the conceptual model, is developed to evaluate the consequences of three scenarios: a nuclear phase-out, the implementation of a policy for avoiding imports dependence, and the combination of both. We conclude that the Swiss market is not well prepared to face unexpected changes of supply and demand, and we identify a risk of imports dependence, mainly in the case of a nuclear phase-out. The third essay focus on the opportunity cost of hydro-storage power generation, one of the main generation sources in Switzerland. We use and extended version of our model to test different policies for assigning an opportunity cost to hydro-storage power generation. We conclude that the preferred policies are different for different market participants and depend on market structure.
Resumo:
Communication is an indispensable component of animal societies, yet many open questions remain regarding the factors affecting the evolution and reliability of signalling systems. A potentially important factor is the level of genetic relatedness between signallers and receivers. To quantitatively explore the role of relatedness in the evolution of reliable signals, we conducted artificial evolution over 500 generations in a system of foraging robots that can emit and perceive light signals. By devising a quantitative measure of signal reliability, and comparing independently evolving populations differing in within-group relatedness, we show a strong positive correlation between relatedness and reliability. Unrelated robots produced unreliable signals, whereas highly related robots produced signals that reliably indicated the location of the food source and thereby increased performance. Comparisons across populations also revealed that the frequency for signal production-which is often used as a proxy of signal reliability in empirical studies on animal communication-is a poor predictor of signal reliability and, accordingly, is not consistently correlated with group performance. This has important implications for our understanding of signal evolution and the empirical tools that are used to investigate communication.
Resumo:
OBJECTIVE: To demonstrate the validity and reliability of volumetric quantitative computed tomography (vQCT) with multi-slice computed tomography (MSCT) and dual energy X-ray absorptiometry (DXA) for hip bone mineral density (BMD) measurements, and to compare the differences between the two techniques in discriminating postmenopausal women with osteoporosis-related vertebral fractures from those without. METHODS: Ninety subjects were enrolled and divided into three groups based on the BMD values of the lumbar spine and/or the femoral neck by DXA. Groups 1 and 2 consisted of postmenopausal women with BMD changes <-2SD, with and without radiographically confirmed vertebral fracture (n=11 and 33, respectively). Group 3 comprised normal controls with BMD changes > or =-1SD (n=46). Post-MSCT (GE, LightSpeed16) scan reconstructed images of the abdominal-pelvic region, 1.25 mm thick per slice, were processed by OsteoCAD software to calculate the following parameters: volumetric BMD values of trabecular bone (TRAB), cortical bone (CORT), and integral bone (INTGL) of the left femoral neck, femoral neck axis length (NAL), and minimum cross-section area (mCSA). DXA BMD measurements of the lumbar spine (AP-SPINE) and the left femoral neck (NECK) also were performed for each subject. RESULTS: The values of all seven parameters were significantly lower in subjects of Groups 1 and 2 than in normal postmenopausal women (P<0.05, respectively). Comparing Groups 1 and 2, 3D-TRAB and 3D-INTGL were significantly lower in postmenopausal women with vertebral fracture(s) [(109.8+/-9.61) and (243.3+/-33.0) mg/cm3, respectively] than in those without [(148.9+/-7.47) and (285.4+/-17.8) mg/cm(3), respectively] (P<0.05, respectively), but no significant differences were evident in AP-SPINE or NECK BMD. CONCLUSION: the femoral neck-derived volumetric BMD parameters using vQCT appeared better than the DXA-derived ones in discriminating osteoporotic postmenopausal women with vertebral fractures from those without. vQCT might be useful to evaluate the effect of osteoporotic vertebral fracture status on changes in bone mass in the femoral neck.
Resumo:
OBJECTIVES: To preliminarily evaluate prospectively the accuracy and reliability of a specific ad hoc reduction-compression forceps in intraoral open reduction of transverse and displaced mandibular angle fractures. STUDY DESIGN: We analyzed the clinical and radiologic data of 7 patients with 7 single transverse and displaced angle fractures. An intraoral approach was performed in all of the patients without using perioperative intermaxillary fixation. A single Arbeitsgemeinschaft Osteosynthese (AO) unilock reconstruction plate was fixed to each stable fragment with 3 locking screws (2.0 mm in 5 patients and 2.4 mm in 2 patients) at the basilar border of the mandible, according to AO/American Society of Internal Fixation (ASIF) principles. Follow-up was at 1, 3, 6, and 12 months, and we noted the status of healing and complications, if any. RESULTS: All of the patients had satisfactory fracture reduction as well as a successful treatment outcome without complications. CONCLUSION: This preliminary study demonstrated that the intraoral reduction of transverse and displaced angle fractures using a specific ad hoc reduction-forceps results in a high rate of success.