961 resultados para pulmonary function tests
Resumo:
The role of small, hydrophobic peptides that are associated with ion pumps or channels is still poorly understood. By using the Xenopus oocyte as an expression system, we have characterized the structural and functional properties of the gamma peptide which co-purifies with Na,K-ATPase. Immuno-radiolabeling of epitope-tagged gamma subunits in intact oocytes and protease protection assays show that the gamma peptide is a type I membrane protein lacking a signal sequence and exposing the N-terminus to the extracytoplasmic side. Co-expression of the rat or Xenopus gamma subunit with various proteins in the oocyte reveals that it specifically associates only with isozymes of Na,K-ATPase. The gamma peptide does not influence the formation and cell surface expression of functional Na,K-ATPase alpha-beta complexes. On the other hand, the gamma peptide itself needs association with Na,K-ATPase in order to be stably expressed in the oocyte and to be transported efficiently to the plasma membrane. Gamma subunits do not associate with individual alpha or beta subunits but only interact with assembled, transport-competent alpha-beta complexes. Finally, electrophysiological measurements indicate that the gamma peptide modulates the K+ activation of Na,K pumps. These data document for the first time the membrane topology, the specificity of association and a potential functional role for the gamma subunit of Na,K-ATPase.
Resumo:
The present study analysed the concordance among four different molecular diagnostic methods for tuberculosis (TB) in pulmonary and blood samples from immunocompromised patients. A total of 165 blood and 194 sputum samples were collected from 181 human immunodeficiency virus (HIV)-infected patients with upper respiratory complaints, regardless of suspicious for TB. The samples were submitted for smear microscopy, culture and molecular tests: a laboratory-developed conventional polymerase chain reaction (PCR) and real-time quantitative PCR (qPCR) and the Gen-Probe and Detect-TB Ampligenix kits. The samples were handled blindly by all the technicians involved, from sample processing to results analysis. For sputum, the sensitivity and specificity were 100% and 96.7% for qPCR, 81.8% and 94.5% for Gen-Probe and 100% and 66.3% for Detect-TB, respectively. qPCR presented the best concordance with sputum culture [kappa (k) = 0.864)], followed by Gen-Probe (k = 0.682). For blood samples, qPCR showed 100% sensitivity and 92.3% specificity, with a substantial correlation with sputum culture (k = 0.754) and with the qPCR results obtained from sputum of the corresponding patient (k = 0.630). Conventional PCR demonstrated the worst results for sputa and blood, with a sensitivity of 100% vs. 88.9% and a specificity of 46.3% vs. 32%, respectively. Commercial or laboratory-developed molecular assays can overcome the difficulties in the diagnosis of TB in paucibacillary patients using conventional methods available in most laboratories.
Resumo:
The aim of this study was to characterize the effect of a 5 km running time trial on the neuromuscular properties of the plantar flexors. Eleven well-trained triathletes performed a series of neuromuscular tests before and immediately after the run on a 200 m indoor track. Muscle activation (twitch interpolation) and normalized EMG activity were assessed during maximal voluntary contraction (MVC) of plantar flexors. Maximal soleus H-reflexes and M-waves were evoked at rest (i.e. H (MAX) and M (MAX), respectively) and during MVC (i.e. H (SUP) and M (SUP), respectively). MVC significantly declined (-27%; P < 0.001) after the run, due to decrease in muscle activation (-8%; P < 0.05) and M (MAX)-normalized EMG activity (-13%; P < 0.05). Significant reductions in M-wave amplitudes (M (MAX): -13% and M (SUP): -16%; P < 0.05) as well as H (MAX)/M (MAX) (-37%; P < 0.01) and H (SUP)/M (SUP) (-25%; P < 0.05) ratios occurred with fatigue. Following exercise, the single twitch was characterized by lower peak torque (-16%; P < 0.001) as well as shorter contraction (-19%; P < 0.001) and half-relaxation (-24%; P < 0.001) times. In conclusion, the reduction in plantar flexors strength induced by a 5 km running time trial is caused by peripheral adjustments, which are attributable to a failure of the neuromuscular transmission and excitation-contraction coupling. Fatigue also decreased the magnitude of efferent motor outflow from spinal motor neurons to the plantar flexors and part of this suboptimal neural drive is the result of an inhibition of soleus motoneuron pool reflex excitability.
Resumo:
OBJECTIVE: An inverse relationship between blood pressure (BP) and cognitive function has been found in adults, but limited data are available in adolescents and young adults. We examined the prospective relation between BP and cognitive function in adolescence. METHODS: We examined the association between BP measured at the ages of 12-15 years in school surveys and cognitive endpoints measured in the Seychelles Child Development Study at ages 17 (n = 407) and 19 (n = 429) years, respectively. We evaluated multiple domains of cognition based on subtests of the Cambridge Neurological Test Automated Battery (CANTAB), the Woodcock Johnson Test of Scholastic Achievement (WJTA), the Finger Tapping test (FT) and the Kaufman Brief Intelligence Test (K-BIT). We used age, sex and height-specific z-scores of SBP, DBP and mean arterial pressure (MAP). RESULTS: Six out of the 21 cognitive endpoints tested were associated with BP. However, none of these associations were found to hold for both males and females or for different subtests within the same neurodevelopmental domain or for both SBP and DBP. Most of these associations disappeared when analyses were adjusted for selected potential confounding factors such as socio-economic status, birth weight, gestational age, BMI, alcohol consumption, blood glucose, and total n-3 and n-6 polyunsaturated fats. CONCLUSIONS: Our findings do not support a consistent association between BP and subsequent performance on tests assessing various cognitive domains in adolescents.
Resumo:
BACKGROUND: The Pulmonary Embolism Severity Index (PESI) estimates the risk of 30-day mortality in patients with acute pulmonary embolism (PE). We constructed a simplified version of the PESI. METHODS: The study retrospectively developed a simplified PESI clinical prediction rule for estimating the risk of 30-day mortality in a derivation cohort of Spanish outpatients. Simplified and original PESI performances were compared in the derivation cohort. The simplified PESI underwent retrospective external validation in an independent multinational cohort (Registro Informatizado de la Enfermedad Tromboembólica [RIETE] cohort) of outpatients. RESULTS: In the derivation data set, univariate logistic regression of the original 11 PESI variables led to the removal of variables that did not reach statistical significance and subsequently produced the simplified PESI that contained the variables of age, cancer, chronic cardiopulmonary disease, heart rate, systolic blood pressure, and oxyhemoglobin saturation levels. The prognostic accuracy of the original and simplified PESI scores did not differ (area under the curve, 0.75 [95% confidence interval (CI), 0.69-0.80]). The 305 of 995 patients (30.7%) who were classified as low risk by the simplified PESI had a 30-day mortality of 1.0% (95% CI, 0.0%-2.1%) compared with 10.9% (8.5%-13.2%) in the high-risk group. In the RIETE validation cohort, 2569 of 7106 patients (36.2%) who were classified as low risk by the simplified PESI had a 30-day mortality of 1.1% (95% CI, 0.7%-1.5%) compared with 8.9% (8.1%-9.8%) in the high-risk group. CONCLUSION: The simplified PESI has similar prognostic accuracy and clinical utility and greater ease of use compared with the original PESI.
Resumo:
Background The PEmb-QoL is a validated 40-item questionnaire to quantify health-related quality of life in patients having experienced pulmonary embolism (PE). It covers six health dimensions: frequency of complaints, activities of daily living limitations, work-related problems, social limitations, intensity of complaints, and emotional complaints. Originally developed in Dutch and English, we sought to prospectively validate the psychometric properties of a French version of the PEmb-QoL.MethodsWe performed a forward and backward translation of the English version of the PEmb-QoL into French. French-speaking consecutive adult patients with an acute, objectively confirmed PE admitted to the emergency department of a Swiss university hospital between 08/2009 and 09/2011 were recruited telephonically. We used standard psychometric tests and criteria to evaluate the acceptability, reliability, and validity of the French version of the PEmb-QoL. We also performed an exploratory factor analysis.ResultsOverall, 102 patients were enrolled in the study. The French version of the PEmb-QoL showed good reliability (internal consistency, item¿total and inter-item correlations), reproducibility (test-retest reliability), and validity (convergent, discriminant) in French-speaking patients with PE. The exploratory factor analysis suggested three underlying dimensions: limitations in daily activity (items 4b-m, 5a-d), symptoms (items 1a-h and 7), and emotional complaints (items 9a-f and j).ConclusionWe successfully validated the French version of the PEmb-QoL questionnaire in patients with PE. Our results show that the PEmb-QoL is a valuable tool for assessing health-related quality of life after PE in French-speaking patients.
Resumo:
Perfusion lung scan, whether associated with a ventilation lung scan or not, is frequently used in the diagnosis of pulmonary emboli. The characteristics of perfusion lung scan are reviewed. The added diagnostic value of standard chest X-ray and of ventilation scan is discussed, as well as its use in the intensive care unit.
Resumo:
Rapport de synthèse : But : Evaluer l'effet de la dronédarone sur la fonction rénale et le transport tubulaire des cations. Méthodes : Douze sujets masculins en bonne santé ont été inclus dans une étude randomisée, croisée, comparée à un placebo, en double aveugle. Ils ont reçu 400 mg de dronédarone ou un placebo deux fois par jour pendant sept jours. Des tests fonctionnels rénaux ont été effectués avant le traitement et en cours de traitement après une standardisation stricte des apports, par détermination de la clairance de la créatinine, de la sinistrine, du para-amino-hippurate (PAH) et du N-méthylnicotinamide (NMN) et de l'excrétion des électrolytes. Résultats : Comparée au placebo, la dronédarone a réduit de manière significative la clairance de la créatinine (en moyenne 138-119 ml/min après dronédarone vs 142-149 ml/min après placebo) et la clairance du NMN (448-368 ml/min vs 435-430 ml/min), mais n'a pas eu d'effet sur la clairance rénale de la sinistrine, du PAH ou sur d'autres paramètres rénaux. Conclusion : La dronédarone réduit la clairance rénale de la créatinine et du NMN d'environ 18%, sans évidence d'effet sur la filtration glomérulaire, sur le flux plasmatique rénal ou sur les échanges électrolytiques. Cela suggère une inhibition spécifique partielle du transport tubulaire organique des cations (OCT). Une augmentation limitée de la créatininémie est donc à attendre sous traitement de dronédarone, sans que cela ne soit assimilable à une baisse de la fonction rénale.
Resumo:
Objective: An inverse relationship between blood pressure and cognitive function has been found in adults, but limited data are available in adolescents and young adults. We prospectively examined the relation between blood pressure and cognitive function in adolescence. Methods: We examined the association between BP measured at the ages of 12-15 years in school surveys and cognitive endpoints measured in the Seychelles Child Development Study at ages 17 (n=407) and 19 (n=429) years respectively. We evaluated multiple domains of cognition based on subtests of the Cambridge Neurological Test Automated Battery (CANTAB), the Woodcock Johnson Test of Scholastic Achievement (WJTA), the Finger Tapping test (FT) and the Kaufman Brief Intelligence Test (K-BIT). We used age-, sex- and height-specific z-scores of systolic blood pressure (SBP), diastolic blood pressure (DBP) and mean arterial pressure (MAP). Results: Six out of the 21 cognitive endpoints tested were associated with BP. However, none of these associations were found to hold for both males and females or for different subtests within the same neurodevelopmental domain or for both SBP and DBP. Most of these associations disappeared when analyses were adjusted for selected potential confounding factors such as socio-economic status, birth weight, gestational age, body mass index, alcohol consumption, blood glucose, and total n-3 and n-6 polyunsaturated fats. Conclusions: Our findings do not support a consistent association between BP and subsequent performance on tests assessing various cognitive domains in adolescents.
Resumo:
BACKGROUND: Disease-management programs may enhance the quality of care provided to patients with chronic diseases, such as chronic obstructive pulmonary disease (COPD). The aim of this systematic review was to assess the effectiveness of COPD disease-management programs. METHODS: We conducted a computerized search of MEDLINE, EMBASE, CINAHL, PsychINFO, and the Cochrane Library (CENTRAL) for studies evaluating interventions meeting our operational definition of disease management: patient education, 2 or more different intervention components, 2 or more health care professionals actively involved in patients' care, and intervention lasting 12 months or more. Programs conducted in hospital only and those targeting patients receiving palliative care were excluded. Two reviewers evaluated 12,749 titles and fully reviewed 139 articles; among these, data from 13 studies were included and extracted. Clinical outcomes considered were all-cause mortality, lung function, exercise capacity (walking distance), health-related quality of life, symptoms, COPD exacerbations, and health care use. A meta-analysis of exercise capacity and all-cause mortality was performed using random-effects models. RESULTS: The studies included were 9 randomized controlled trials, 1 controlled trial, and 3 uncontrolled before-after trials. Results indicate that the disease-management programs studied significantly improved exercise capacity (32.2 m, 95% confidence interval [CI], 4.1-60.3), decreased risk of hospitalization, and moderately improved health-related quality of life. All-cause mortality did not differ between groups (pooled odds ratio 0.84, 95% CI, 0.54-1.40). CONCLUSION: COPD disease-management programs modestly improved exercise capacity, health-related quality of life, and hospital admissions, but not all-cause mortality. Future studies should explore the specific elements or characteristics of these programs that bring the greatest benefit.
Resumo:
Objectives: Existing VADs are single-ventricle pumps needing anticoagulation. We developed a bi-ventricular external assist device that partially reproduces the physiological muscle function of the heart. This artificial muscle could wrap the heart and improve its contractile force.Methods: The device has a carbon fiber skeleton fitting a 30-40kg patient's heart, to which a Nitinol based artificial muscle is connected. The artificial muscle wraps both ventricles. The Nitinol fibers are woven on a Kevlar mesh surrounding each ventricle. The fibers are electrically driven with a dedicated control unit developed for this purpose. We assessed hemodynamic performances of this device using a previously described dedicated bench test. Volume ejected and pressure gradient have been measured with afterload ranging from 10 to 50mmHg.Results: With an afterload of 50mmHg the system has an ejection fraction of 4% on the right side and 5% on the left side. The system is able to generate a systolic ejection of 2.2mL on the right side and 3.25mL on the left side. With an afterload of 25mmHg the results are reduced of about 20%. The activation frequency can reach 80/minute resulting in a total volume displacement of 176mL/minute on the right side and 260mL/minute on the left side.Conclusions: These preliminary studies confirmed the possibility of improving the ejection fraction of a failing heart using artificial muscle for external cardiac compression avoiding anticoagulation therapy. This device could be helpful in weaning cardio-pulmonary bypass and/or for short-term cardio-circulatory support in pediatric population with cardiac failure.
Resumo:
OBJECTIVES: Pulmonary valve insufficiency remains a leading cause for reoperations in congenital cardiac surgery. The current percutaneous approach is limited by the size of the access vessel and variable right ventricular outflow tract morphology. This study assesses the feasibility of transapical pulmonary valve replacement based on a new valved stent construction concept. METHODS: A new valved stent design was implanted off-pump under continuous intracardiac echocardiographic and fluoroscopic guidance into the native right ventricular outflow tract in 8 pigs (48.5 +/- 6.0 kg) through the right ventricular apex, and device function was studied by using invasive and noninvasive measures. RESULTS: Procedural success was 100% at the first attempt. Procedural time was 75 +/- 15 minutes. All devices were delivered at the target site with good acute valve function. No valved stents dislodged. No animal had significant regurgitation or paravalvular leaking on intracardiac echocardiographic analysis. All animals had a competent tricuspid valve and no signs of right ventricular dysfunction. The planimetric valve orifice was 2.85 +/- 0.32 cm(2). No damage to the pulmonary artery or structural defect of the valved stents was found at necropsy. CONCLUSIONS: This study confirms the feasibility of direct access valve replacement through the transapical procedure for replacement of the pulmonary valve, as well as validity of the new valved stent design concept. The transapical procedure is targeting a broader patient pool, including the very young and the adult patient. The device design might not be restricted to failing conduits only and could allow for implantation in a larger patient population, including those with native right ventricular outflow tract configurations.
Resumo:
This study investigated the influence of two warm-up protocols on neural and contractile parameters of knee extensors. A series of neuromuscular tests including voluntary and electrically evoked contractions were performed before and after running- (R (WU); slow running, athletic drills, and sprints) and strength-based (S (WU); bilateral 90 degrees back squats, Olympic lifting movements and reactivity exercises) warm ups (duration ~40 min) in ten-trained subjects. The estimated overall mechanical work was comparable between protocols. Maximal voluntary contraction torque (+15.6%; P < 0.01 and +10.9%; P < 0.05) and muscle activation (+10.9 and +12.9%; P < 0.05) increased to the same extent after R (WU) and S (WU), respectively. Both protocols caused a significant shortening of time to contract (-12.8 and -11.8% after R (WU) and S (WU); P < 0.05), while the other twitch parameters did not change significantly. Running- and strength-based warm ups induce similar increase in knee extensors force-generating capacity by improving the muscle activation. Both protocols have similar effects on M-wave and isometric twitch characteristics.
Resumo:
Background: Chronic obstructive pulmonary disease (COPD) has been associated with increased risk for heart failure (HF). The impact of subclinical abnormal spirometric findings on HF risk among older adults without history of COPD is not well elucidated. Methods: We evaluated 2125 participants (age 73.6±2.9 years; 50.5% men; 62.3% white; 45.6/9.4% past/current smokers; body mass index [BMI] 27.2±4.6 kg/m2) without prevalent COPD or HF who underwent baseline spirometry in the Health ABC Study. Abnormal lung function was defined either as forced vital capacity (FVC) below lower limit of normal (LLN) or forced expiratory volume in 1st sec (FEV1) to FVC ratio below LLN. Results: On follow-up (median, 9.4 years), 68 of 350 (19.4%) participants with abnormal lung function developed HF, as compared to 172 of 1775 (9.7%) participants with normal lung function (hazard ratio [HR], 2.31; 95% confidence interval [CI], 1.74 -3.06; P<.001). This increased risk persisted after adjusting for all other independent predictors of HF in the Health ABC Study, BMI, incident coronary events, and several inflammatory markers (HR, 1.82; 95% CI, 1.30 -2.54; P<.001), and remained constant over time. Baseline FVC and FEV1 had a linear association with HF risk (Figure). In adjusted models, HF risk increased by 21% (95% CI, 10 -36%) per 10% decrease in FVC and 18% (95% CI, 10 -28%) per 10% decrease in FEV1 (both P<.001); this association persisted among participants with normal lung function at baseline. Findings were consistent across sex, race, and smoking status. Conclusions: Subclinical abnormal spirometric findings are prevalent among older adults and are independently associated with risk for incident HF.
Resumo:
Bronchiolitis obliterans (BO) following allogeneic haematopoietic stem cell transplantation (HSCT) affects peripheral airways. Detection of BO is presently delayed by the low sensitivity of spirometry. We examined the relationship between peripheral airway function and time since HSCT, and compared it with spirometry and clinical indices in 33 clinically stable allogeneic HSCT recipients. The following measurements were performed: lung function, exhaled nitric oxide, forced oscillatory respiratory system resistance and reactance, acinar (S(acin)) and conductive airways ventilation heterogeneity and lung clearance index (LCI) measured by multiple breath nitrogen washout. 22 patients underwent repeat visits from which short-term changes were examined. Median time post HSCT was 12 months. Eight patients were clinically diagnosed as having BO. In multivariate analysis, time since HSCT was predicted by S(acin) and forced expiratory volume in 1 s % predicted. 20 patients had abnormal S(acin) with normal spirometry, whereas none had airflow obstruction with normal S(acin). S(acin) and LCI were the only measures to change significantly between two visits, with both worsening. Change in S(acin) was the only parameter to correlate with change in chronic graft-versus-host disease grade. In conclusion, peripheral airways ventilation heterogeneity worsens with time after HSCT. S(acin) may be more sensitive than spirometry in detecting BO at an early stage, which needs confirmation in a prospective study.