972 resultados para pressure gradient
Resumo:
Extensive measurements of columnar aerosol optical depth (AOD), composite (M-T) and black carbon aerosol mass (M-B) concentrations were made over the tropical Indian and Southern Oceans as a part of the Pilot Expedition to the Southern Ocean during the boreal winter. The AOD, M-T and M-B show large latitudinal gradient towards south up to ITCZ. Beyond ITCZ, up to 56 degrees S, AOD and M-B show very low and steady values. However M-T shows large variations in the Southern Ocean due to the enhanced production of sea salt aerosols associated with high sea surface winds. The short wave aerosol radiative forcing at the surface over north of equator is in the range - 10 to -23 W m(-2), whereas that over the Southern Ocean was in the range -4 to -5 W m(-2). The corresponding atmospheric forcing was in the range of 6-13 W m(-2) and 0.8-1.4 W m(-2). This large north south change in the aerosol radiative forcing has important implications to the meridional circulation and hence to climate.
Resumo:
Experimental studies on the measurement of pressure fields in the region of separating and reattaching flows behind several two-dimensional fore-bodies and one axisymmetric body are reported. In particular, extensive measurements of mean pressure, surface pressure fluctuation, and pressure fluctuation within the flow were made for a series of two-dimensional fore-body shapes consisting of triangular nose with varying included angle. The measurements from different bodies are compared and one of the important findings is that the maximum values of rms pressure fluctuation levels in the shear layer approaching reattachment are almost equal to the maximum value of the surface fluctuation levels.
Resumo:
The performance of a pressure transducer with meandering-path thin film strain gauges has been studied. Details of the procedure followed to prepare the thin film strain gauge system on the pressure transducer diaphragm are given. The effect of post-deposition heat treatment on the resistance of the sensing films of the strain gauges and the insulating base layers are discussed. The output of the pressure transducer was studied with various input pressures and excitation voltages. It was found that up to a maximum of 10 V bridge excitation the output was stable and repetitive. The maximum non-linearity and hysteresis observed are ±0.15%, ±0.16% and ±0.14% FSO (full-scale output) for 5, 7.5 and 10 V excitation respectively. Information on the output behaviour of the pressure transducer with temperature is also included.
Resumo:
This study is focused on the development and evaluation of ion mobility instrumentation with various atmospheric pressure ionization techniques and includes the following work. First, a high-resolution drift tube ion mobility spectrometer (IMS), coupled with a commercial triple quadrupole mass spectrometer (MS), was developed. This drift tube IMS is compatible with the front-end of commercial Sciex mass spectrometers (e.g., Sciex API-300, 365, and 3000) and also allows easy (only minor modifications are needed) installation between the original atmospheric pressure ion source and the triple quadrupole mass spectrometer. Performance haracteristics (e.g.,resolving power, detection limit, transmission efficiency of ions) of this IMS-MS instrument were evaluated. Development of the IMS-MS instrument also led to a study where a proposal was made that tetraalkylammonium ions can be used as chemical standards for ESI-IMS. Second, the same drift tube design was also used to build a standalone ion mobility spectrometer equipped with a Faraday plate detector. For this highresolution (resolving power about 100 shown) IMS device, a multi-ion source platform was built, which allows the use of a range of atmospheric pressure ionization methods, such as: corona discharge chemical ionization (CD-APCI), atmospheric pressure photoionization (APPI), and radioactive atmospheric pressure chemical ionization (R-APCI). The multi-ion source platform provides easy switching between ionization methods and both positive and negative ionization modes can be used. Third, a simple desorpion/ionization on silicon (DIOS) ion source set-up for use with the developed IMS and IMS-MS instruments was built and its operation demonstrated. Fourth, a prototype of a commercial aspiration-type ion mobility spectrometer was mounted in front of a commercial triple quadrupole mass spectrometer. The set-up, which is simple, easy to install, and requires no major modifications to the MS, provides the possibility of gathering fundamental information about aspiration mobility spectrometry.
Resumo:
A diaphragm-type pressure transducer with a sputtered platinum film strain gauge (sensing film) has been designed and fabricated. The various steps followed to prepare thin film strain gauges on the diaphragm are described. M-bond 450 adhesive (Measurements Group, USA) has been employed as the insulating layer. A detailed procedure to cure this layer is given. A d.c. sputtering method is employed to prepare the platinum films. This paper also includes details of the strain gauge pattern and its location on the diaphragm. A description of the output characteristics and overall behaviour of the platinum thin film pressure transducer is reported.
Effect of High Pressure on the Electrical Conductivity of TlInX2 (X = Se, Te) Layered Semiconductors
Resumo:
The dc electrical conductivity of TlInX2 (X = Se, Te) single crystals, parallel and perpendicular to the (001) c-axis is studied under high quasi-hydrostatic pressure up to 7.0 GPa, at room temperature. Conductivity measurements parallel to the c-axis are carried out at high pressures and down to liquid nitrogen temperatures. These materials show continuous metallization under pressure. Both compounds have almost the same pressure coefficient of the electrical activation energy parallel to the c-axis, d(ΔE∥)/dP = −2.9 × 10−10 eV/Pa, which results from the narrowing of the band gap under pressure. The results are discussed in the light of the band structure of these compounds.
Resumo:
The EMF of a solid-state cell, incorporating a composite solid-electrolyte with gradual variation in composition, and dissimilar gas electrodes, has been studied as a function of temperature and partial pressures at the electrodes. The cell with the configuration: Pt, CO2' + O2' parallel-to Na2CO3\Na(SO4)x(CO3)1-x\Na2SO4 parallel-to SO3'' + SO2'' + O2'', Pt x=0 x=1 was investigated in the temperature range 973 to 1079 K. The solid-electrolyte surface exposed to SO3 + SO2 + O2 gas mixture was doped-Na2SO4, whereas the CO2 + O2 gas mixture was in contact with pure Na2CO3. The composition of the solid solution between the carbonate and sulfate, with hexagonal structure, was varied gradually between the boundary values. It has been found that the EMF of the cell is close to that calculated from thermodynamic data, assuming unit transport number for Na+ ions. The gradient in the concentration of sulfate and carbonate ions in the electrolyte does not give rise to a significant diffusion potential.
Resumo:
Wide-line proton NMR spectra of ammonium thiocyanate have been recorded at 77 K as a function of external hydrostatic pressure. Contrary to expectations the line-width and the second moment decrease with the increase of pressure. This, however, is in accordance with the anomalous behaviour observed in other magnetic resonance studies of this compound and can be understood in terms of the change of electron density around the nitrogen atom of the SCN- group.
Resumo:
The characteristics of the high pressure oxygen-sputtering plasma in the pressure range 0.8–2.4 mbar have been studied using the Langmuir probe technique. The variation in plasma parameters such as positive ion density, electron density, mean electron energy and floating potential with pressure and temperature has been investigated. It has been observed that the positive ion density increases at high substrate temperatures whereas the negative ion density decreases. The study of the variation in mean electron energy and floating potential also indicated the possibility that the number of negative ions is less when the substrates are at elevated temperatures. Since the negative ions are supposed to cause re-sputtering and make the films off-stoichiometric, the reduction in the negative ion density as observed at elevated substrate temperatures is better suited for depositing stoichiometric YBa2Cu3O7−δ superconducting thin films.
Resumo:
Room-temperature Raman spectra of LiRbSO4 were studied as a function of pressure up to 170 kbar for two different orientations of the crystal. Four pressure-induced phase transitions at about 2, 17, 32 and 57 kbar were observed. The transitions at 17 and 57 kbar have slow kinetics, taking about 4 h for their completion. These phase transitions are associated with the orientations of the SO4 ions in the unit cell.
Resumo:
The thermodynamic properties of K2CO3 -KSO, solid solutions with hexagonal structure have been measured using a solid-state cell, incorporating a composite solid electrolyte with step-changes in composition. The cell with the configuration Pt, CO2' + O2' || K2CO3 | K2(CO3)x(SO4)1-x || CO2'' + O2'' + Pt X =1 X=X was investigated in the temperature range of 925 to 1165 K. The composite gradient solid electrolyte consisted of pure K2CO3 at one extremity and the solid solution under study at the other. The Nernstian response of the cell to changes in partial pressures of CO2 and O2 at the electrodes and temperature was demonstrated. The activity of K2CO3 in the solid solution was measured by three techniques. All three methods gave identical results, indicating unit transport number for K+ ions and negligible diffusion potential due to concentration gradients of carbonate and sulfate ions. The activity of K2CO3 exhibits positive deviation from Raoult's law. The excess Gibbs energy of mixing of the solid solution can be represented using a subregular solution model DELTAG(E) = X(1 - X)[5030X + 4715(1 - X)] J mol-1 By combining this information with the phase diagram, mixing properties of the liquid phase were obtained.
Resumo:
larity solution is obtained for laminar 3D constant pressure flow with lateral streamline divergence. The similarity solution is shown to reduce to a Blasius solution for 2D flow over a flat plate. Measurements of velocity profiles are made to compare the similarity solution and are found to be in excellent agreement with the prediction
Resumo:
Purpose: Fast reconstruction of interior optical parameter distribution using a new approach called Broyden-based model iterative image reconstruction (BMOBIIR) and adjoint Broyden-based MOBIIR (ABMOBIIR) of a tissue and a tissue mimicking phantom from boundary measurement data in diffuse optical tomography (DOT). Methods: DOT is a nonlinear and ill-posed inverse problem. Newton-based MOBIIR algorithm, which is generally used, requires repeated evaluation of the Jacobian which consumes bulk of the computation time for reconstruction. In this study, we propose a Broyden approach-based accelerated scheme for Jacobian computation and it is combined with conjugate gradient scheme (CGS) for fast reconstruction. The method makes explicit use of secant and adjoint information that can be obtained from forward solution of the diffusion equation. This approach reduces the computational time many fold by approximating the system Jacobian successively through low-rank updates. Results: Simulation studies have been carried out with single as well as multiple inhomogeneities. Algorithms are validated using an experimental study carried out on a pork tissue with fat acting as an inhomogeneity. The results obtained through the proposed BMOBIIR and ABMOBIIR approaches are compared with those of Newton-based MOBIIR algorithm. The mean squared error and execution time are used as metrics for comparing the results of reconstruction. Conclusions: We have shown through experimental and simulation studies that Broyden-based MOBIIR and adjoint Broyden-based methods are capable of reconstructing single as well as multiple inhomogeneities in tissue and a tissue-mimicking phantom. Broyden MOBIIR and adjoint Broyden MOBIIR methods are computationally simple and they result in much faster implementations because they avoid direct evaluation of Jacobian. The image reconstructions have been carried out with different initial values using Newton, Broyden, and adjoint Broyden approaches. These algorithms work well when the initial guess is close to the true solution. However, when initial guess is far away from true solution, Newton-based MOBIIR gives better reconstructed images. The proposed methods are found to be stable with noisy measurement data. (C) 2011 American Association of Physicists in Medicine. DOI: 10.1118/1.3531572]
Resumo:
High-pressure resistivity measurements have been performed on G37.5AsxTe92.5-x (x = 20, 40, 45, 50 and 55) and Ge10AsxTe90-x (x = 15, 20, 35, 40, 45 and 50) glasses. The glasses show reversible metallization behaviour under pressure. The pressure derivative of the logarithm of the resistivity of the glasses is a minimum at glass compositions corresponding to the average coordination number [r] = 2.60. This behaviour is interpreted on the basis of the existence of a critical composition in glasses with a layered structure.