963 resultados para plasma concentration-time curve


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective was to evaluate the effects of plasma progesterone (P4) concentrations and exogenous eCG on ovulation and pregnancy rates of pubertal Nellore heifers in fixed-time artificial insemination (FTAI) protocols. In Experiment 1 (Exp. 1), on Day 0 (7 d after ovulation), heifers (n = 15) were given 2 mg of estradiol benzoate (EB) im and randomly allocated to receive: an intravaginal progesterone-releasing device containing 0.558 g of P4 (group 0.5G, n = 4); an intravaginal device containing 1 g of P4 (group 1G, n = 4); 0.558 g of P4 and PGF2α (PGF; 150 μg d-cloprostenol, group 0.5G/PGF, n = 4); or 1 g of P4 and PGF (group 1G/PGF, n = 3). On Day 8, PGF was given to all heifers and intravaginal devices removed; 24 h later (Day 9), all heifers were given 1 mg EB im. In Exp. 2, pubertal Nellore heifers (n = 292) were treated as in Exp. 1, with FTAI on Day 10 (30 to 36 h after EB). In Exp. 3, pubertal heifers (n = 459) received the treatments described for groups 0.5G/PGF and 1G/PGF and were also given 300 IU of eCG im (groups 0.5G/PGF/eCG and 1G/PGF/eCG) at device removal (Day 8). In Exp. 1, plasma P4 concentrations were significantly higher in heifers that received 1.0 vs 0.588 g P4, and were significantly lower in heifers that received PGF on Day 0. In Exp. 2 and 3, there were no significant differences among groups in rates of ovulation (65-77%) or pregnancy (Exp. 2: 26-33%; Exp. 3: 39-43%). In Exp. 3, diameter of the dominant ovarian follicle on Day 9 was larger in heifers given 0.558 g vs 1.0 g P4 (10.3 ± 0.2 vs 9.3 ± 0.2 mm; P < 0.01). In conclusion, lesser amounts of P4 in the intravaginal device or PGF on Day 0 decreased plasma P4 from Days 1 to 8 and increased diameter of the dominant follicle on Day 9. However, neither of these nor 300 IU of eCG on Day 8 significantly increased rates of ovulation or pregnancy. © 2011.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Dentre as ferramentas para alcançar o tratamento ótimo para a malária, se destaca a monitorização das concentrações dos antimaláricos nos fluídos biológicos. Ao se considerar que o Coartem® é empregado na terapia de primeira linha para o tratamento da malária falciparum, justifica-se a realização deste estudo que objetivou validar metodologia analítica para determinação de lumefantrina em amostras de sangue total, adsorvidas em papel de filtro, e em plasma, por cromatografia líquida de alta eficiência (CLAE), em pacientes com malária por Plasmodium falciparum não complicada, empregando-se extração líquido-líquido. Foram realizados estudos de seletividade, linearidade, curva de calibração, limites de detecção e quantificação, recuperação, precisão intra e inter-ensaio, estabilidade e robustez. As amostras, para o estudo de aplicabilidade do método proposto, foram coletadas de pacientes com malária falciparum utilizando Coartem® (arteméter-20mg + lumefantrina- 120mg) no D3. As condições cromatográficas otimizadas foram: comprimento de onda de 335nm, fluxo 1,2mL/min. e fase móvel composta por acetonitrila-água (60:40, v/v) pH=3,5. A extração líquido-líquido demonstrou ser eficiente, pois a recuperação média foi de 101,3% para plasma e 84,3% para sangue total. O método foi seletivo e linear em intervalo de concentração de 160 a 1760ng/mL. Os limites de detecção e de quantificação foram 32ng/mL e 160ng/mL. O coeficiente de variação médio intra-ensaio, do plasma e sangue total, respectivamente, foram 10,88 e 8,38% e inter-ensaio de 13,21 e 11,78%. O analito demonstrou ser estável em sangue total adsorvido em papel de filtro por até 70 dias. Modificações no pH, fluxo e composição da fase móvel não alteraram significativamente a resolução do analito de interesse, sugerindo uma robustez adequada. O método demonstrou ser eficaz na quantificação de lumefantrina em amostras de sangue total de pacientes com malária falciparum bem como os parâmetros de validação estão de acordo com as recomendações dos órgãos regulamentadores no Brasil.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents the study on the application of the electrolytic plasma for surface treatment of aluminum. A bibliographical study on the material of interest was preliminarily performed and later designed and built an electrolytic cell, including the excitation source. Unlike conventional electrolysis process, the plasma assisted carry on in the non-linear region of characteristic current/voltage curve. Therefore it requires for the on set of the process that the power supply operates on harder conditions than those on high current process. The plasma produced during the present investigation has temperatures in the range o 6,0.10 3 -7,0 .10 3 K, well above those found in conventional chemical process. It also shows a particular dynamic to promote changes on surface and to produce new materials. The plasma is generated by microdischarge in vapor or gas bubbles involved in physic-chemical processes in electrode regions of the electrolytic cell. The electrode material was the aluminum (7075). The Process Electrolytic Plasma Processing (EPP) is sensitive to various parameters such as operating voltage, current density, electrolyte, concentration of electrolyte, geometry of reactor, temperature of electrolytic solution and dynamic of the fluid in the cell. The experiments were carried on in order to find parameters for a stable abd steady operation. The choice for the electrolytic was silicate/alkali solution in various concentrations to operate in various voltage as well. Plasma was produced on negative (cathode) and positive (anode) electrode, in specific conditions. A stable operation on the cathode process was obtained with low concentration of the electrolytic in aqueous solution, current density around 250V effective voltage. For the evolution of plasma in anodic process it was required higher concentrations and higher... (Complete abstract click electronic access below)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To evaluate the effects of coronal leakage on concentration of hydrogen ions (pH) and calcium release of several calcium hydroxide pastes, over different periods of time. Material and Methods: Fifty extracted human mandibular central incisors (n=10) were instrumented up to the F2 instrument and assigned to the following intracanal dressing: G1- Calen, G2- Calen with 0.4% chlorhexidine (CHX), G3- Calcium hydroxide with camphorated paramonochlorophenol (CPMC) and glycerin, G4- Calen, but temporary filling material maintained during all test (positive control) and G5- Root canal without intracanal dressing (negative control). All groups were immersed in distilled water for 7 days. In sequence, the temporary filling materials were removed, except in controls groups. All specimens were individually mounted on a specific device and only its root again immersed in distilled water. Concentration of hydrogen ions and calcium release by calcium hydroxide pastes in distilled water were evaluated in 24h, 7, 14 and 28 days. The results were submitted to ANOVA test (p = 0.05). After 28 days, root canals from experimental groups were examined in SEM. Results: G1, G2, G3 and G4 presented similar pH values and calcium release and did not differ from each other (p>0.05), up to 7 days. After this time G1, G2 and G3 presented values lower values than G4 (p<0.05). In SEM analysis, calcium hydroxide residues were observed in all experimental groups. Conclusions: After 7 days, coronal leakage decreased the concentration of hydrogen ions and calcium ion release provided by all calcium hydroxide pastes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this study was to compare the pharmacokinetics of tetracycline in plasma, synovial fluid, and milk following either a single systemic intravenous (i.v.) injection or a single i.v. regional antibiosis (IVRA) administration of tetracycline hydrochloride to dairy cattle with papillomatous digital dermatitis (PDD). To this end, plasma and synovial fluid tetracycline concentrations were compared with the minimal inhibitory concentration (MIC) values of the major bacteria, which are known to cause digital diseases and thus assess its efficacy in PDD. Residual tetracycline concentrations in milk from cows treated by both methods were also determined. Twelve Holstein cows with various stages of PDD were randomly assigned to two groups of six animals. Group 1 received a single systemic i.v. injection of 10 mg/kg of tetracycline hydrochloride. Group 2 received 1000 mg of tetracycline hydrochloride by IVRA of the affected limb. Blood, synovial fluid and milk samples were taken prior to tetracycline administration (time 0 control), and then at 22, 45 and 82 min, and 2, 3, 4, 6, 8, 12, 24, 48, 72, 96, and 120 h following drug administration. Tetracycline concentrations were determined by high-performance liquid chromatography. Mean tetracycline plasma and milk concentrations in Group 1 were higher than Group 2. The opposite was observed for synovial fluid concentrations. Group 2 synovial fluid concentrations were higher than the MIC value over 24 h for the bacteria most frequently responsible for claw disease. Compared with i.v. administration, IVRA administration of tetracycline produced very high synovial fluid and low plasma and milk concentrations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)