951 resultados para ocular ultrasound
Resumo:
We present 6 patients with ocular involvement due to paracoccidioidomycosis. All cases were confirmed by the finding of Paracoccidioides brasiliensis in histopathological or direct mycologic examination of material from the lesion in the eyelid or conjunctiva. In two cases the bulbar conjunctiva was also involved, in another the cornea, and still another patient developed endophthalmitis. The presence of this mutilating disease which may lead to blindness should be suspected when chronic blepharitis or palpebral ulcerated papular lesions are detected in patients from endemic areas of paracoccidioidomycosis. This etiology should also be suspected in patients with anterior and posterior uveitis after discarding the most frequent causes of this condition. © 1988 Kluwer Academic Publishers.
Resumo:
The acid catalyzed and ultrasound stimulated hydrolysis of solventless tetraethoxysilane-water mixtures was studied at 39°C as a function of HCl added to the mixtures (log[HCl]-1 ranged from 0.8 to 2.0), The reaction was carried out in a specially designed device, in which a steady state heat flow is maintained, while sonication is taking place, if no reaction is expected to occur. The exothermal hydrolysis reaction causes an increasing temperature (ΔTt) as a function of the reaction time, t. The isothermal hydrolysis rate constant, k, has been evaluated from the experimental ΔTt versus t data, after corrections for the increasing temperature effects, by using a method resulting from our theoretical modeling based on a dissolution and reaction mechanism. The hydrolysis rate constant fits closely a k α [H+] law as expected for this kind of hydrogen-ion catalyzed reaction.
Resumo:
Temporal and spatial acoustic intensity (SATA) of therapeutic ultrasound (US) equipment should be monitored periodically. In order to evaluate the conditions of US equipment in use in the city of Piracicaba-Sao Paulo, Brazil, 31 machines - representing all Brazilian manufacturers - were analysed under continuous and pulsed conditions at a frequency of 1 MHz. Data about temporal and spatial acoustic intensity were collected and the use of equipment was surveyed. Intensities of 0.1, 0.2, 0.5, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0 Wcm -2, indicated on the equipment panel were analysed using a previously calibrated digital radiation pressure scale, model UPM-DT-1 (Ohmic Instruments Co). The acoustic intensity (I) results were expressed as superior and inferior quartile ranges for transducers with metal surfaces of 9 cm 2 and an effective radiation area (ERA) Of 4 cm 2. The results under continuous conditions were: I 0.1 = -20.0% and -96%. I 0.2 = -3.1% and -83.7%. I 0.5 = -35.0% and -86.5%. I 0.8 = -37.5% and -71.0%. I 2.5 = -49.0% and -69.5%. I 3.0 = -58.1% and -77.6%. For pulsed conditions, intensities were: I 0.1 = -40.0% and -86.2%. I 1.0 = -50.0% and -86.5%. I 1.5 = -62.5% and -82.5%. I 2.0 = -62.5% and -81.6%. I 2.5 = -64.7% and -88.8%. I 3.0 = -87.1% and -94.8%. In reply to the questionnaire drawn up to check the conditions of use of equipment, all users reported the use of hydrosoluble gel as a coupling medium and none had carried out previous calibrations. Most users used intensities in the range of 0.4. to 1.0 Wcm -2 and used machines for 300 to 400 minutes per week. The majority of machines had been bought during the previous seven years and weekly use ranged from less than 100 minutes to 700 minutes (11 hours 40 minutes). Findings confirm previous observations of discrepancy between the intensity indicated on the equipment panel and that emitted by the transducer and highlight the necessity for periodic evaluations of US equipment.
Resumo:
Structural changes induced by ultrasound during the aging of the aluminum monohydroxide (boehmite) were studied by means of X-ray diffraction (XRD) and nitrogen adsorption. The BET surface area and the pore volume of the ultrasound stimulated hydroxide (HU) are about 40% less than those of the non-stimulated one (HS). The mean pore size practically does not change, while the mean crystallite size (L) is about 25% greater in the HU system. The increase of L alone is not enough to account for the surface area diminution, suggesting that the sonication also induces compaction by elimination of some porosity. The sonication of the precursor hydroxide does not seem to play an apparent role in the structural properties of the resulting calcinated γ-alumina. © 1997 Elsevier Science B.V.
Resumo:
Diphasic gel in the mullite composition was prepared from a colloidal sol of boehmite mixed with a hydrolyzed tetraethoxisilane (TEOS) solution. The boehmite sol was obtained by peptization of a poorly crystallized or very small mean crystallite size (∼34 Å) precipitate, resulting from the reaction between solutions of aluminum sulfate and sodium hydroxide. Ultrasound was utilized in the processes of the TEOS hydrolysis and the boehmite peptization, and also for complete homogenization of the mixture to gel. The wet gel is almost clear and monolithic. The gel transparency is lost on drying, when syneresis has ended, so that the interlinked pore structure starts to empty and is recovered upon water re-absorption. Cracking closely accompanies this critical drying process. Differential thermal analysis (DTA) and X-ray diffraction (XRD) show that the solid structure of the gel is composed of an amorphous silica phase, as a matrix, and a colloidal sized crystalline phase of boehmite. Upon heat treatment, the boehmite phase within the gel closely follows the same transition sequence as in pure alumina shifted towards higher temperatures. Orthorhombic mullite formation was detected at 1300°C. © 1998 Elsevier Science B.V. All rights reserved.
Resumo:
The objective of this study was to investigate the effects of ultrasound treatment and physical exercise on the velocity of bone consolidation and resistance to deformation. We performed osteotomy in the upper third of the right tibia of rats. Physical training consisted of swimming 1 h per day with a load of 5% b.w. for 30 days. Therapy with medium-intensity ultrasound was applied daily on the damaged area. Wistar rats were divided into the following groups: osteotomized sedentary animals with no ultrasound treatment (1.OSnUS), osteotomized trained animals with no ultrasound treatment (2.OTnUS), osteotomized sedentary animals with ultrasound treatment (3.OSwUS). and osteotomized trained animals with ultrasound treatment (4.OTwUS). The animals were sacrificed for the following analyses: muscle glycogen, serum alkaline phosphatase at the 5th, 10th, 20th, and 30th days, test of maximum resistance to flexion, rupture flexion and mean tibial rigidity at the 30th day. Muscle glycogen was increased at the 20th day: alkaline phosphatase was elevated at the 5th and 20th days in groups 3.OSwUS and 4.OTwUS. and decreased at the 10th day. Groups1.OSnUS and 2.OTnUS did not show significant variations. In the mechanical resistance tests, we noted that ultrasound therapy and the association of physical activity used in the present study showed significant differences in bone resistance and bone rigidity after 30 days of treatment. These facts suggest that ultrasound or physical activity, or their combination may accelerate the process of bone tissue repair.
Resumo:
Aim: The aim of this study was to evaluate the influence of ultrasound during the removal of posts cemented with either zinc phosphate cement, glass ionomer cement or resin cement. Methodology: Eighty-four single-rooted teeth were prepared and after cementation of cast posts, they were randomly divided into six groups of 14. Groups 1, 2 and 3 did not receive ultrasonic vibration, whilst groups 4, 5 and 6 received ultrasonic vibration for 10 min. The force necessary for post removal was determined using a universal testing machine. Results were statistically analysed using ANOVA and Tukey tests (5%). Results: The application of ultrasonic vibration reduced the retention provided by zinc phosphate and glass ionomer cements by 39% and 33%, respectively. Conclusions: A statistically significant reduction in the force necessary to remove posts cemented with zinc phosphate and glass ionomer cements occurred following application of ultrasound. The application of ultrasonic vibration did not influence the retention of cast posts cemented with resin cement.
Resumo:
This paper presents an ultrasonic method to measure small concentrations of water in lubricating oil. It uses an ultrasonic measurement cell composed by a piezoceramic emitter (5 and 10 MHz), and a large aperture PVDF receiver that eliminates diffraction effects. The propagation velocity, attenuation coefficient and density of several samples of water-in-oil emulsion were measured. The concentrations of water of the samples were in the range of 0 to 5% in volume, and the results showed that these low concentrations can be discriminated within a resolution of 0.2% in the studied range, using the measurement of the propagation velocity.
Resumo:
Purpose: To study the effects of two drugs (captopril and propranolol) used in the treatment of systemic hypertension, on the intraocular pressure (IOP) of anesthetized dogs. Methods: 24 dogs, divided into 3 groups of 8 each. In the first group, 1.5 mg/kg IV of captopril (an angiotensin converting enzyme inhibitor) was administered. In the second group, 1.5 mg/kg IV of propranolol (a beta-blocker) was administered. The third group was the control. IOP and blood pressure (BP) were measured by manometry. The perfusion pressure was calculated by the difference between BP and IOP (BP-IOP). The parameters were studied at 6 moments (0, 10, 30, 60, 90 and 120 minutes). Results: There was significant reduction of IOP (p<0.05) with captopril and propranolol, without difference between the drugs. With captopril the BP and PP decreased markedly at 10 and 30 minutes. With propranolol there was no reduction of BP or PP. Conclusions: Captopril and propranolol reduced IOP. However, the marked reduction of BP, and consequently of PP caused by captopril may be undesirable for irrigation of the optic nerve.
Resumo:
The effects of low-intensity pulsed ultrasound on wound healing were evaluated at the graft-cornea transition in dogs following lamellar keratoplasty using tunica vaginalis preserved in 98% glycerin. Twenty-one dogs were subdivided into three groups of seven animals. The first group (W/US) received daily treatment of low-intensity pulsed ultrasound (20 mW/cm 2) for 15 min for the first 10 days post surgery. The second group (N/US) was submitted to the same procedure but with the ultrasound apparatus turned off. The third group, the control (CO), underwent the surgical procedure only. The animals were clinically evaluated during the initial (1-15 days), intermediate (16-30 days) and late (31-120 days) postoperative period. The corneas were evaluated by light microscopy at 1, 3, 7, 15, 30, 60 and 120 days after surgery. Clinically, there were no differences which would promote an advantage to any of the treatments. Light microscopy, however, revealed more extensive vascularization and more advanced wound healing in the W/US group, as well as a tendency towards early graft incorporation. Based on the present results, low-intensity pulsed ultrasound shows advantages, especially in situations where trophic support is a mandatory condition, facilitating better graft incorporation and rapid recovery of stromal organization.
Resumo:
The ocular losses are embarrassing to the bearer because they commit the face which has the essential organs for the human relationship. The present study shows the multidiscipline interaction in the treatment of a child who lost his left eye victim of a fire gun and needed an ocular plastic surgery for a correct prosthesis insertion. The ocular prosthesis fills in the ocular cavity simulating the facial growth and restoring its symmetry. Therefore, there are aesthetics, anatomic and physiological improvement on the child's face that allows her to be reinstated in society without being discriminated for her differences. © 2005 Elsevier Ltd. All rights reserved.
Resumo:
The patient with anophthalmia may present feelings of inferiority and rejection. Knowing his/her needs and expectations contribute to a better technical intervention. Purpose: To elaborate a questionnaire of the psychosocial profile of the patient with anophthalmia with indication of ocular prosthesis. Methods: An exploratory research was used to elaborate the questionnaire, by means of a guided interview followed by writing down what was said by the interviewees, who were adult patients of the Bucco-Maxillo-Facial Prosthesis Center of FOSJC - UNESP. The guided interview was made up of 14 items directly related to the future outline of the profile. Each item of the interview resulted in questions of the questionnaire, which was pretested twice before reaching its final version. Results: The patients reported, in the exploratory research, unpleasant feelings with the loss of the eye; relationship shyness; expectations regarding surgery and prosthesis use; a wish to receive explanations and to hold their opinion about the treatment. The questionnaire of the psychosocial profile of the patient with anophthalmia with indication of ocular prosthesis is, therefore, made of 43 questions divided into 5 blocks in order to aid the comprehension of the inquired aspects and to facilitate both the computation of data and discussion, and also to improve the selection of questions according to the objective of the researcher or professional. Conclusions: It was concluded that the questionnaire was viable, can be used in full or by selecting blocks and provide a panorama of the patient's history related to the problem he/she faces, from the loss of the ocular globe to the confection of the prosthesis.