690 resultados para magnesium alloys
Resumo:
The strength decrease in magnesium implants was studied in vitro and in vivo, with and without a protective plasmaelectrolytic coating. In vivo, degradation was examined by implanting rectangular plates on top of the nasal bone of miniature pigs. The presence of gas pockets in the soft tissue surrounding the implants was evaluated with intermediate X-rays and computed X-ray tomography scans before euthanasia. After 12 and 24weeks of in vivo degradation, the large rectangular plates were removed and mechanically tested in three-point bending. In vitro, identical plates were immersed in simulated body fluid for 4, 8 and 12weeks. In vitro and in vivo results showed that onset of gas release can be delayed by the plasmaelectrolytic coating. Mass loss and strength retention during in vivo degradation is about four times slower than during in vitro degradation for the chosen test conditions. Despite the slow degradation of the investigated WE43 alloy, the occurrence of gas pockets could not be completely avoided. Nevertheless, uniformity of degradation and reliable strength retention make this alloy a prime candidate for the use of magnesium in cranio-maxillofacial surgery.
Resumo:
Claudins are major components of tight junctions and contribute to the epithelial-barrier function by restricting free diffusion of solutes through the paracellular pathway. We have mapped a new locus for recessive renal magnesium loss on chromosome 1p34.2 and have identified mutations in CLDN19, a member of the claudin multigene family, in patients affected by hypomagnesemia, renal failure, and severe ocular abnormalities. CLDN19 encodes the tight-junction protein claudin-19, and we demonstrate high expression of CLDN19 in renal tubules and the retina. The identified mutations interfere severely with either cell-membrane trafficking or the assembly of the claudin-19 protein. The identification of CLDN19 mutations in patients with chronic renal failure and severe visual impairment supports the fundamental role of claudin-19 for normal renal tubular function and undisturbed organization and development of the retina.
Resumo:
BACKGROUND: Mortality and morbidity from acute myocardial infarction (AMI) remain high. Intravenous magnesium started early after the onset of AMI is thought to be a promising adjuvant treatment. Conflicting results from earlier trials and meta-analyses warrant a systematic review of available evidence. OBJECTIVES: To examine the effect of intravenous magnesium versus placebo on early mortality and morbidity. SEARCH STRATEGY: We searched CENTRAL (The Cochrane Library Issue 3, 2006), MEDLINE (January 1966 to June 2006) and EMBASE (January 1980 to June 2006), and the Chinese Biomedical Disk (CBM disk) (January 1978 to June 2006). Some core Chinese medical journals relevant to the cardiovascular field were hand searched from their starting date to the first-half year of 2006. SELECTION CRITERIA: All randomized controlled trials that compared intravenous magnesium with placebo in the presence or absence of fibrinolytic therapy in addition to routine treatment were eligible if they reported mortality and morbidity within 35 days of AMI onset. DATA COLLECTION AND ANALYSIS: Two reviewers independently assessed the trial quality and extracted data using a standard form. Odds ratio (OR) were used to pool the effect if appropriate. Where heterogeneity of effects was found, clinical and methodological sources of this were explored. MAIN RESULTS: For early mortality where there was evidence of heterogeneity, a fixed-effect meta-analysis showed no difference between magnesium and placebo groups (OR 0.99, 95%CI 0.94 to 1.04), while a random-effects meta-analysis showed a significant reduction comparing magnesium with placebo (OR 0.66, 95% CI 0.53 to 0.82). Stratification by timing of treatment (< 6 hrs, 6+ hrs) reduced heterogeneity, and in both fixed-effect and random-effects models no significant effect of magnesium was found. In stratified analyses, early mortality was reduced for patients not treated with thrombolysis (OR=0.73, 95% CI 0.56 to 0.94 by random-effects model) and for those treated with less than 75 mmol of magnesium (OR=0.59, 95% CI 0.49 to 0.70) in the magnesium compared with placebo groups.Meta-analysis for the secondary outcomes where there was no evidence of heterogeneity showed reductions in the odds of ventricular fibrillation (OR=0.88, 95% CI 0.81 to 0.96), but increases in the odds of profound hypotension (OR=1.13, 95% CI 1.09 to 1.19) and bradycardia (OR=1.49, 95% CI 1.26 to 1.77) comparing magnesium with placebo. No difference was observed for heart block (OR=1.05, 95% CI 0.97-1.14). For those outcomes where there was evidence of heterogeneity, meta-analysis with both fixed-effect and random-effects models showed that magnesium could decrease ventricular tachycardia (OR=0.45, 95% CI 0.31 to 0.66 by fixed-effect model; OR=0.40, 95% CI 0.19 to 0.84 by random-effects model) and severe arrhythmia needing treatment or Lown 2-5 (OR=0.72, 95% CI 0.60 to 0.85 by fixed-effect model; OR=0.51, 95% CI 0.33 to 0.79 by random-effects model) compared with placebo. There was no difference on the effect of cardiogenic shock between the two groups. AUTHORS' CONCLUSIONS: Owing to the likelihood of publication bias and marked heterogeneity of treatment effects, it is essential that the findings are interpreted cautiously. From the evidence reviewed here, we consider that: (1) it is unlikely that magnesium is beneficial in reducing mortality both in patients treated early and in patients treated late, and in patients already receiving thrombolytic therapy; (2) it is unlikely that magnesium will reduce mortality when used at high dose (>=75 mmol); (3) magnesium treatment may reduce the incidence of ventricular fibrillation, ventricular tachycardia, severe arrhythmia needing treatment or Lown 2-5, but it may increase the incidence of profound hypotension, bradycardia and flushing; and (4) the areas of uncertainty regarding the effect of magnesium on mortality remain the effect of low dose treatment (< 75 mmol) and in patients not treate...
Resumo:
BACKGROUND: Coronary stents improve immediate and late results of balloon angioplasty by tacking up dissections and preventing wall recoil. These goals are achieved within weeks after angioplasty, but with current technology stents permanently remain in the artery, with many limitations including the need for long-term antiplatelet treatment to avoid thrombosis. We report a prospective multicentre clinical trial of coronary implantations of absorbable magnesium stents. METHODS: We enrolled 63 patients (44 men; mean age 61.3 [SD 9.5 years]) in eight centres with single de novo lesions in a native coronary artery in a multicentre, non-randomised prospective study. Follow-up included coronary angiography and intravascular ultrasound at 4 months and clinical assessment at 6 months and 12 months. The primary endpoint was cardiac death, non-fatal myocardial infarction, or clinically driven target lesion revascularisation at 4 months FINDINGS: 71 stents, 10-15 mm in length and 3.0-3.5 mm in diameter, were successfully implanted after pre-dilatation in 63 patients. Diameter stenosis was reduced from 61.5 (SD 13.1%) to 12.6 (5.6%) with an acute gain of 1.41 mm (0.46 mm) and in-stent late loss of 1.08 mm (0.49 mm). The ischaemia-driven target lesion revascularisation rate was 23.8% after 4 months, and the overall target lesion revascularisation rate was 45% after 1 year. No myocardial infarction, subacute or late thrombosis, or death occurred. Angiography at 4 months showed an increased diameter stenosis of 48.4 (17.0%). After serial intravascular ultrasound examinations, only small remnants of the original struts were visible, well embedded into the intima. Neointimal growth and negative remodelling were the main operating mechanisms of restenosis. INTERPRETATION: This study shows that biodegradable magnesium stents can achieve an immediate angiographic result similar to the result of other metal stents and can be safely degraded after 4 months. Modifications of stent characteristics with prolonged degradation and drug elution are currently in development.
Resumo:
OBJECTIVES: Magnesium aspartate hydrochloride (Magnesiocard, Mg-Asp-HCl) is proposed as a substitute of magnesium sulfate for the treatment of preeclampsia and premature labor. After an i.v. administration of a dose equivalent to that used in the treatment of preeclampsia to nonpregnant volunteers, a 10-fold increase of aspartic acid (Asp) over the physiological level was observed. Animal experiments have demonstrated that highly increased fetal levels of acidic amino acids such as Asp could be associated with neurotoxic damage in the fetal brain. The influence of such an elevation of Asp concentration in the maternal circuit on the fetal level, using the in vitro perfusion model of human placenta, was investigated. STUDY DESIGN: After a control phase (2h), a therapeutic dose of Mg combined with Asp (Magnesiocard, Mg-Asp-HCl) was applied to the maternal circuit approaching 10 times the physiological level of Asp. The administration was performed in two different phases simulating either a peak of maximum concentration (bolus application, 2h) or a steady state level (initially added, 4h). RESULTS: In four experiments, during experimental phases (6h) a slow increase in concentration in the fetal circuit was seen for Mg, AIB (alpha-aminoisobutyric acid, artificial amino acid) and creatinine confirming previous observations. In contrast, no net transfer of Asp across the placenta was seen. A continuous decrease in the concentration of Asp on both maternal and fetal side suggests active uptake and metabolization by the placenta. Viability control parameters remained stable indicating the absence of an effect on placental metabolism, permeability and morphology. CONCLUSION: Elevation of Asp concentration up to 10 times the physiological level by the administration of Mg-Asp-HCl to the maternal circuit under in vitro perfusion conditions of human placenta has no influence on the fetal level of Asp suggesting no transfer of Asp from the maternal to fetal compartment. Therefore, the administration of Mg-Asp-HCl to preeclamptic patients would be beneficial for the patients without any impact on placental or fetal physiology.
Resumo:
In this study, the use of magnesium as a Hall thruster propellant was evaluated. A xenon Hall thruster was modified such that magnesium propellant could be loaded into the anode and use waste heat from the thruster discharge to drive the propellant vaporization. A control scheme was developed, which allowed for precise control of the mass flow rate while still using plasma heating as the main mechanism for evaporation. The thruster anode, which also served as the propellant reservoir, was designed such that the open area was too low for sufficient vapor flow at normal operating temperatures (i.e. plasma heating alone). The remaining heat needed to achieve enough vapor flow to sustain thruster discharge came from a counter-wound resistive heater located behind the anode. The control system has the ability to arrest thermal runaway in a direct evaporation feed system and stabilize the discharge current during voltage-limited operation. A proportional-integral-derivative control algorithm was implemented to enable automated operation of the mass flow control system using the discharge current as the measured variable and the anode heater current as the controlled parameter. Steady-state operation at constant voltage with discharge current excursions less than 0.35 A was demonstrated for 70 min. Using this long-duration method, stable operation was achieved with heater powers as low as 6% of the total discharge power. Using the thermal mass flow control system the thruster operated stably enough and long enough that performance measurements could be obtained and compared to the performance of the thruster using xenon propellant. It was found that when operated with magnesium, the thruster has thrust ranging from 34 mN at 200 V to 39 mN at 300 V with 1.7 mg/s of propellant. It was found to have 27 mN of thrust at 300 V using 1.0 mg/s of propellant. The thrust-to-power ratio ranged from 24 mN/kW at 200 V to 18 mN/kW at 300 volts. The specific impulse was 2000 s at 200 V and upwards of 2700 s at 300 V. The anode efficiency was found to be ~23% using magnesium, which is substantially lower than the 40% anode efficiency of xenon at approximately equivalent molar flow rates. Measurements in the plasma plume of the thruster—operated using magnesium and xenon propellants—were obtained using a Faraday probe to measure off-axis current distribution, a retarding potential analyzer to measure ion energy, and a double Langmuir probe to measure plasma density, electron temperature, and plasma potential. Additionally, the off axis current distributions and ion energy distributions were compared to measurements made in krypton and bismuth plasmas obtained in previous studies of the same thruster. Comparisons showed that magnesium had the largest beam divergence of the four propellants while the others had similar divergence. The comparisons also showed that magnesium and krypton both had very low voltage utilization compared to xenon and bismuth. It is likely that the differences in plume structure are due to the atomic differences between the propellants; the ionization mean free path goes down with increasing atomic mass. Magnesium and krypton have long ionization mean free paths and therefore require physically larger thruster dimensions for efficient thruster operation and would benefit from magnetic shielding.
Resumo:
It is known that the electrical resistance of annealed metals is usually smaller than that of metals in their cold worked state. The curve showing the relation between electrical resistance and annealing temperature reaches a minimum; continued annealing at higher temperature produces an increase in the electrical resistance. In the case of alloys it has been noted that a second decrease occurs at higher annealing temperature. The following work corroborates the observance of previous investigations. The electrical resistance of cold worked copper, gold, nickel, and iron decreased with annealing and then increased, the minimum being around 300° C. or 400° C. Monel metal showed a minimum resistance followed by an increase which in turn was followed by a second decrease.
Resumo:
In order to determine the best annealing temperature at which to age-harden the alloys, hardness tests on specimen annealed for different lengths of time at different temperatures were made.
Resumo:
Prior to the last few years little practical use was made of the element tellurium, which is obtained from gold and silver tellurides and from the slimes of electrolytic copper refineries. Lately, however, more study has been made of its properties when alloyed with other metals. It was the purpose of this thesis to study the effects of the addition of tellurium to lead, particularly in small amounts.
Resumo:
Among the many aluminum alloys which have been studied are the binary copper-aluminum alloys. These have proven to be among the most useful of the aluminum alloys thus far worked upon.
Resumo:
Today considerable work is being done in the compressed metal powder field which is gradually obtaining prominence as a valuable branch of metallurgy. The mass of data, however, has led to many different ideas on the results of sintering.
Resumo:
The alloy system selected for study was the binary alloy of platinum and silver. An examination of the various silver alloy diagrams revealed that of several possible alloys, the silver platinum was the most suitable with regard to solubility.
Some Preliminary Investiagtions of the Magnetic Permeabilities of Alloys of the Ferromagnetic Metals
Resumo:
The problem presented for this thesis was an investigation of the magnetic properties of the alloys produced by the methods of powder metallurgy. The question behind this was the correlation of the magnetic properties with the bonding properties and with the diffusion of the constituents.