942 resultados para electric power plant


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The explanation of resonance given in IEEE Std C57.149-2012 to define resonance during frequency response analysis (FRA) measurements on transformers implicitly uses the conditions prevalent during resonance in a series R-L-C circuit. This dependence is evident from the two assertions made in the definition, viz., resulting in zero net reactive impedance, and, accompanied by a zero value appearing in the phase angle of the frequency response function. These two conditions are satisfied (at resonance) only in a series R-L-C circuit and certainly not in a transformer, as has been assumed in the Standard. This can be proved by considering a ladder-network model. Circuit analysis of this ladder network reveals the origin of this fallacy and proves that, at resonance, neither is the ladder network purely resistive and nor is the phase angle (between input voltage and input current) always zero. Also, during FRA measurements, it is often seen that phase angle does not traverse the conventional cyclic path from +90 degrees to -90 degrees (or vice versa) at all resonant frequencies. This peculiar feature can also be explained using pole-zero maps. Simple derivations, simulations and experimental results on an actual winding are presented. In summary, authors believe that this study dispels existing misconceptions about definition of FRA resonance and provides material for its correction in IEEE Std C57.149-2012. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Several operational aspects for thermal power plants in general are non-intuitive and involve simultaneous optimization of a number of operational parameters. In the case of solar operated power plants, it is even more difficult due to varying heat source temperatures induced by variability in insolation levels. This paper introduces a quantitative methodology for load regulation of a CO2 based Brayton cycle power plant using the `thermal efficiency and specific work output' coordinate system. The analysis shows that a transcritical CO2 cycle offers more flexibility under part load performance than the supercritical cycle in case of non-solar power plants. However, for concentrated solar power, where efficiency is important, supercritical CO2 cycle fares better than transcritical CO2 cycle. A number of empirical equations relating heat source temperature, high side pressure with efficiency and specific work output are proposed which could assist in generating control algorithms. (C) 2015 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper, a detailed thermodynamic performance analysis of a transcritical condensing (TC) cycle is performed with pure CO2 and a blend of 48.5 % propane with 51.5 % CO2 as working fluids. A realistic thermodynamic model is used incorporating irreversibilities in turbo-machineries and heat exchangers. The Key finding is that the addition of propane elevates the heat rejection temperature, but does not impair any of the performance indicators. Such a fluid may be useful for power generation in concentrated solar power applications by using which a hike of up to 2 % can be realized in the thermal efficiency of a power plant.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Low-power electronic devices used in digital telecom exchanges are vulnerable to surge voltages and currents primarily originating from natural lightning or due to the direct interactions between electric power and telecommunication lines, etc., causing the earth/ground potential rise, neutral potential rise, and faults in the system. The fault currents may flow directly to telecom lines or through the equipment to the customer's premises, causing adequate damage to the equipment and personnel safety. In wireline applications, analog or digital, central office, exchanges, and subscriber sides have to be protected. Decisive protection and protective methods have to be employed for proper functioning of the equipment under overvoltage/overcurrent conditions. Current investigation reports some interesting results obtained on the recently developed high-voltage high-current protection cards used in digital telecom exchanges. The performances of protection cards both for the ring wave and hybrid wave surges are evaluated and presented. The surge generators required for the investigation are developed and fabricated in house as per the relevant telecom standards.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper we analyse the behaviour of the EU market for CO2 emission allowances; specifically, we focus on the contracts maturing in the Kyoto Protocol's second period of application (2008 to 2012). We calibrate the underlying parameters for the allowance price in the long run and we also calibrate those from the Spanish wholesale electricity market. This information is then used to assess the option to install a carbon capture and storage (CCS) unit in a coal-fired power plant. We use a two-dimensional binomial lattice where costs and profits are valued and the optimal investment time is determined. In other words, we study the trigger allowance prices above which it is optimal to install the capture unit immediately. We further analyse the impact of several variables on the critical prices, among them allowance price volatility and a hypothetical government subsidy. We conclude that, at current permit prices, from a financial point of view, immediate installation does not seem justified. This need not be the case, though, if carbon market parameters change dramatically and/or a specific policy to promote these units is adopted.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper deals with the valuation of energy assets related to natural gas. In particular, we evaluate a baseload Natural Gas Combined Cycle (NGCC) power plant and an ancillary instalation, namely a Liquefied Natural Gas (LNG) facility, in a realistic setting; specifically, these investments enjoy a long useful life but require some non-negligible time to build. Then we focus on the valuation of several investment options again in a realistic setting. These include the option to invest in the power plant when there is uncertainty concerning the initial outlay, or the option's time to maturity, or the cost of CO2 emission permits, or when there is a chance to double the plant size in the future. Our model comprises three sources of risk. We consider uncertain gas prices with regard to both the current level and the long-run equilibrium level; the current electricity price is also uncertain. They all are assumed to show mean reversion. The two-factor model for natural gas price is calibrated using data from NYMEX NG futures contracts. Also, we calibrate the one-factor model for electricity price using data from the Spanish wholesale electricity market, respectively. Then we use the estimated parameter values alongside actual physical parameters from a case study to value natural gas plants. Finally, the calibrated parameters are also used in a Monte Carlo simulation framework to evaluate several American-type options to invest in these energy assets. We accomplish this by following the least squares MC approach.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The impact of mechanical stresses upon ichthyoplankton entrained in power plant cooling systems has long been considered negligible. Arguments and evidence exist, however, to show that such a supposition is not universally true, especially in nuclear power plants. The mechanisms of mechanical damage can be detailed in terms of pressure change, acceleration, and shear stress with in the fluid flow field. Laboratory efforts to quantify the effects of mechanical stress have been very sparse. A well-planned bioassay is urgently needed. (PDF has 11 pages.)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

ABSTRACT: The Potomac River Fisheries Program is concerned with the longterm effects of power plant ichthyoplankton entrainment on striped bass(hforone smatilis) recruitment. Since striped bass population fluctuations are determined strongly by environmental conditions during spawning and early development, assessment of power plant-induced ichthyoplankton mortalities must consider the mechanisms controlling spawning success. Ichthyoplankton distributions for 1974, spawning population abundance and fecundity, and environmental conditions were considered for analysis. Loss of the early part of the spawn (including the peak) accounted for the highest mortalities among ichthyoplankton. This was due to the proximity of these distributions to the salt wedge where transport into regions un!ivorable to survival seems to have occurred. The later, successful portion of the spawn occurred further upstream, in fresh tidal portions of the river. The sequence of events Ieading to an assessment of factors affecting ichthyoplankton surnnl are evaluated. Due to high early mortalities in ichthyoplankton, 1974 spawning success was low, and a poor yearclass is projected.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Environmental studies of power plants have recently shifted their emphasis from examination of the effects of heated discharges to studies of the impacts of entire cooling systems. One of the major impacts arises when planktonic organisms are carried into and through a plant with the cooling water. Because of their relatively immobile, free-floating character, planktonic organisms are highly vulnerable to being "entrained" or passively drawn into the cooling water condenser systems of power plants. More than 70% of estuarine animals have planktonic eggs and larvae. The environmental impact of entrainment is related to the composition and abundance of affected organisms, the numbers of organisms in the adjacent waters, survival rates during entrainment as related to natural survival, the ecological roles of entrained organisms, and their reproductive strategies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Detailed description of plankton entrainment in power plant cooling systems.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In selecting an excess temperature at which to operate a power plant cooling system it has been customary to consider only thermal stresses and to use the ratio of the number of organisms killed to the number of organisms entrained. This frequently leads to the selection of a low excess temperature, AT, which, in turn, requires a large volume flow of cooling water. When mortalities due to physical and chemical stresses are included and the total number of entrained organisms killed is taken as the measure of the environmental damage, it becomes evident that the choice of a low excess temperature is seldom, if ever, best.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A multi-disciplinary investigation was conducted in southern Biscayne Bay and Card Sound from 1968 to 1973. The purpose of the investigation was to conduct an integrated study of the ecology of southern Biscayne Bay with special emphasis on the effects of the heated effluent from the Turkey Point fossil fuel power plant, and to predict the impact of additional effluent from the planned conversion of the plant to nuclear fuel. The results of this investigation have been discussed in numerous publications. This report contains the unpublished biology data that resulted from the investigation. (PDF contains 44 pages)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Waste water from some National Electric Power Authority (NEPA) housing units in Nigeria was fed to a 0.4 ha pond which was stocked with 2,200 Sarotherodon galilaeus fingerlings with a mean weight of about 36.0gm and 1000 Cyprinus carpio fingerlings with a mean weight of 10gm. This yielded after 10 months, over 2300 kg of harvestable fish plus over 20,000 Sarotherodon galilaeus fingerlings. The growth rate of C. carpio was not very encouraging possibly because of the type of plankton that colonised the pond. The S. galilaeus became stunted because of overpopulation as there were no carnivores to control their excessive breeding. The physico-chemical parameters were favourable for the growth of fish food organisms

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The physico-chemical parameters of the surface water of Shiroro Lake and its major tributaries at their entry point to the reservoir were assessed over a period of eighteen months. As in other African inland water bodies there were seasonal variations in the parameters measured. The hydrological regime of the lake, precipitation chemistry, bedrock chemistry and hydro-electric power generation influence and determine the inputs of dissolved organic carbon, nutrient levels and water quality of the lake. The added nutrients to the lake by means of the major tributary rivers and inundation of surrounding areas also influence the water quality of the lake. The wet season mean values for water and air temperature were significantly (P <0.05) higher than dry season mean values in all stations. However, for pH, Dissolved oxygen and Phosphate-phosphorus the dry season mean values were higher than wet season mean values

Relevância:

80.00% 80.00%

Publicador:

Resumo:

36 p.