933 resultados para digital radiography systems


Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the growth of the demand on electric energy in the last decades, the urban distribution and transmission systems have experienced a bigger necessity to improve on the substations, the automation procedures and techniques on the operation maneuvers of such systems, in a sense that better attends the quality levels, availability, continuity and operational reliability. In this way, the objective of the present paper is to perform a study of protection and control on an electrical industrial system involving the procedures of digitizing and maneuvers automatism utilizing operational techniques and other pertinent information used in a typical high-voltage Industrial Electrical System. Analysis were made on short-circuits to specify the main components of the 138 [kV] substation, in addition, there were used digital MiCOM relays to make the protection of the present elements. With that, a program was developed to allow the user to monitor the condition of circuit-breakers through a supervision screen being able to simulate some kinds of faults, as well as observing the characteristics of each device. This way, the importance of having a fast and reliable system that ensures the equipment’s protection and the industrial process continuity due to faults on the electrical system is noticeable. It’s important to highlight that all this digitizing was mainly favored by the development of digital technology on the last years, mainly on microelectronics, also with the appearance of supervision gadgets allowing the development of complex systems in supervision and electric energy control

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims: This study compared fractal dimension (FD) values on mandibular trabecular bone in digital and digitized images at different spatial and contrast resolutions. Materials and Methods: 12 radiographs of dried human mandibles were obtained using custom-fabricated hybrid image receptors composed of a periapical radiographic film and a photostimulable phosphor plate (PSP). The film/ PSP sets were disassembled, and the PSPs produced images with 600 dots per inch (dpi) and 16 bits. These images were exported as tagged image file format (TIFF), 16 and 8 bits, and 600, 300 and 150 dpi. The films were processed and digitized 3 times on a flatbed scanner, producing TIFF images with 600, 300 and 150 dpi, and 8 bits. On each image, a circular region of interest was selected on the trabecular alveolar bone, away from root apices and FD was calculated by tile counting method. Two-way ANOVA and Tukey’s test were conducted to compare the mean values of FD, according to image type and spatial resolution (α = 5%). Results: Spatial resolution was directly and inversely proportional to FD mean values and standard deviation, respectively. Spatial resolution of 150 dpi yielded significant lower mean values of FD than the resolutions of 600 and 300 dpi ( P < 0.05). A nonsignificant variability was observed for the image types ( P > 0.05). The interaction between type of image and level of spatial resolution was not signi fi cant (P > 0.05). Conclusion: Under the tested, conditions, FD values of the mandibular trabecular bone assessed either by digital or digitized images did not change. Furthermore, these values were in fluenced by lower spatial resolution but not by contrast resolution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The human dentition is naturally translucent, opalescent and fluorescent. Differences between the level of fluorescence of tooth structure and restorative materials may result in distinct metameric properties and consequently perceptible disparate esthetic behavior, which impairs the esthetic result of the restorations, frustrating both patients and staff. In this study, we evaluated the level of fluorescence of different composites (Durafill in tones A2 (Du), Charisma in tones A2 (Ch), Venus in tone A2 (Ve), Opallis enamel and dentin in tones A2 (OPD and OPE), Point 4 in tones A2 (P4), Z100 in tones A2 ( Z1), Z250 in tones A2 (Z2), Te-Econom in tones A2 (TE), Tetric Ceram in tones A2 (TC), Tetric Ceram N in tones A1, A2, A4 (TN1, TN2, TN4), Four seasons enamel and dentin in tones A2 (and 4SD 4SE), Empress Direct enamel and dentin in tones A2 (EDE and EDD) and Brilliant in tones A2 (Br)). Cylindrical specimens were prepared, coded and photographed in a standardized manner with a Canon EOS digital camera (400 ISO, 2.8 aperture and 1/ 30 speed), in a dark environment under the action of UV light (25 W). The images were analyzed with the software ScanWhite©-DMC/Darwin systems. The results showed statistical differences between the groups (p < 0.05), and between these same groups and the average fluorescence of the dentition of young (18 to 25 years) and adults (40 to 45 years) taken as control. It can be concluded that: Composites Z100, Z250 (3M ESPE) and Point 4 (Kerr) do not match with the fluorescence of human dentition and the fluorescence of the materials was found to be affected by their own tone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Letras - FCLAR

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a new catalogue of galaxy triplets derived from the Sloan Digital Sky Survey (SDSS) Data Release 7. The identification of systems was performed considering galaxies brighter than Mr=-20.5 and imposing constraints over the projected distances, radial velocity differences of neighbouring galaxies and isolation. To improve the identification of triplets, we employed a data pixelization scheme, which allows us to handle large amounts of data as in the SDSS photometric survey. Using spectroscopic and photometric data in the redshift range 0.01 =z= 0.40, we obtain 5901 triplet candidates. We have used a mock catalogue to analyse the completeness and contamination of our methods. The results show a high level of completeness ( 80 per cent) and low contamination ( 5 per cent). By using photometric and spectroscopic data, we have also addressed the effects of fibre collisions in the spectroscopic sample. We have defined an isolation criterion considering the distance of the triplet brightest galaxy to the closest neighbour cluster, to describe a global environment, as well as the galaxies within a fixed aperture, around the triplet brightest galaxy, to measure the local environment. The final catalogue comprises 1092 isolated triplets of galaxies in the redshift range 0.01 =z= 0.40. Our results show that photometric redshifts provide very useful information, allowing us to complete the sample of nearby systems whose detection is affected by fibre collisions, as well as extending the detection of triplets to large distances, where spectroscopic redshifts are not available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Discusses the technological changes that affects learning organizations as well as the human, technical, legal and sustainable aspects regarding learning objects repositories creation, maintenance and use. It presents concepts of information objects and learning objects, the functional requirements needed to their storage at Learning Management Systems. The role of Metadata is reviewed concerning learning objects creation and retrieval, followed by considerations about learning object repositories models, community participation/collaborative strategies and potential derived metrics/indicators. As a result of this desktop research, it can be said that not only technical competencies are critical to any learning objects repository implementation, but it urges that an engaged community of interest be establish as a key to support a learning object repository project. On that matter, researchers are applying Activity Theory (Vygostky, Luria y Leontiev) in order to seek joint perceptions and actions involving learning objects repository users, curators and managers, perceived as critical assets to a successful proposal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is a wide range of telecommunications services that transmit voice, video and data through complex transmission networks and in some cases, the service has not an acceptable quality level for the end user. In this sense the study of methods for assessing video quality and voice have a very important role. This paper presents a classification scheme, based on different criteria, of the methods and metrics that are being studied in recent years. This paper presents how the video quality is affected by degradation in the transmission channel in two kinds of services: Digital TV (ISDB-TB) due the fading in the air interface and video streaming service on an IP network due packet loss. For Digital TV tests was set up a scenario where the digital TV transmitter is connected to an RF channel emulator, where are inserted different fading models and at the end, the videos are saved in a mobile device. The tests of streaming video were performed in an isolated scenario of IP network, which are scheduled several network conditions, resulting in different qualities of video reception. The video quality assessment is performed using objective assessment methods: PSNR, SSIM and VQM. The results show how the losses in the transmission channel affects the quality of end-user experience on both services studied.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The purpose of this study was to analyse the use of digital tools for image enhancement of mandibular radiolucent lesions and the effects of this manipulation on the percentage of correct radiographic diagnoses. Methods: 24 panoramic radiographs exhibiting radiolucent lesions were selected, digitized and evaluated by non-experts (undergraduate and newly graduated practitioners) and by professional experts in oral diagnosis. The percentages of correct and incorrect diagnoses, according to the use of brightness/contrast, sharpness, inversion, highlight and zoom tools, were compared. All dental professionals made their evaluations without (T-1) and with (T-2) a list of radiographic diagnostic parameters. Results: Digital tools were used with low frequency mainly in T-2. The most preferred tool was sharpness (45.2%). In the expert group, the percentage of correct diagnoses did not change when any of the digital tools were used. For the non-expert group, there was an increase in the frequency of correct diagnoses when brightness/contrast was used in T-2 (p = 0.008) and when brightness/contrast and sharpness were not used in T-1 (p = 0.027). The use or non-use of brightness/contrast, zoom and sharpness showed moderate agreement in the group of experts [kappa agreement coefficient (kappa) = 0.514, 0.425 and 0.335, respectively]. For the non-expert group there was slight agreement for all the tools used (kappa <= 0.237). Conclusions: Consulting the list of radiographic parameters before image manipulation reduced the frequency of tool use in both groups of examiners. Consulting the radiographic parameters with the use of some digital tools was important for improving correct diagnosis only in the group of non-expert examiners. Dentomaxillofacial Radiology (2012) 41, 203-210. doi: 10.1259/dmfr/78567773