754 resultados para caustic burn
Resumo:
Neurodegeneration in Parkinson's disease dementia (PDD) and dementia with Lewy bodies (DLB) affect cortical and subcortical networks involved in saccade generation. We therefore expected impairments in saccade performance in both disorders. In order to improve the pathophysiological understanding and to investigate the usefulness of saccades for differential diagnosis, saccades were tested in age- and education-matched patients with PDD (n = 20) and DLB (n = 20), Alzheimer's disease (n = 22) and Parkinson's disease (n = 24), and controls (n = 24). Reflexive (gap, overlap) and complex saccades (prediction, decision and antisaccade) were tested with electro-oculography. PDD and DLB patients had similar impairment in all tasks (P > 0.05, not significant). Compared with controls, they were impaired in both reflexive saccade execution (gap and overlap latencies, P < 0.0001; gains, P < 0.004) and complex saccade performance (target prediction, P < 0.0001; error decisions, P < 0.003; error antisaccades: P < 0.0001). Patients with Alzheimer's disease were only impaired in complex saccade performance (Alzheimer's disease versus controls, target prediction P < 0.001, error decisions P < 0.0001, error antisaccades P < 0.0001), but not reflexive saccade execution (for all, P > 0.05). Patients with Parkinson's disease had, compared with controls, similar complex saccade performance (for all, P > 0.05) and only minimal impairment in reflexive tasks, i.e. hypometric gain in the gap task (P = 0.04). Impaired saccade execution in reflexive tasks allowed discrimination between DLB versus Alzheimer's disease (sensitivity > or =60%, specificity > or =77%) and between PDD versus Parkinson's disease (sensitivity > or =60%, specificity > or =88%) when +/-1.5 standard deviations was used for group discrimination. We conclude that impairments in reflexive saccades may be helpful for differential diagnosis and are minimal when either cortical (Alzheimer's disease) or nigrostriatal neurodegeneration (Parkinson's disease) exists solely; however, they become prominent with combined cortical and subcortical neurodegeneration in PDD and DLB. The similarities in saccade performance in PDD and DLB underline the overlap between these conditions and underscore differences from Alzheimer's disease and Parkinson's disease.
Resumo:
OBJECTIVE To quantify visual discrimination, space-motion, and object-form perception in patients with Parkinson disease dementia (PDD), dementia with Lewy bodies (DLB), and Alzheimer disease (AD). METHODS The authors used a cross-sectional study to compare three demented groups matched for overall dementia severity (PDD: n = 24; DLB: n = 20; AD: n = 23) and two age-, sex-, and education-matched control groups (PD: n = 24, normal controls [NC]: n = 25). RESULTS Visual perception was globally more impaired in PDD than in nondemented controls (NC, PD), but was not different from DLB. Compared to AD, PDD patients tended to perform worse in all perceptual scores. Visual perception of patients with PDD/DLB and visual hallucinations was significantly worse than in patients without hallucinations. CONCLUSIONS Parkinson disease dementia (PDD) is associated with profound visuoperceptual impairments similar to dementia with Lewy bodies (DLB) but different from Alzheimer disease. These findings are consistent with previous neuroimaging studies reporting hypoactivity in cortical areas involved in visual processing in PDD and DLB.
Resumo:
Tungsten isotope compositions of magmatic iron meteorites yield ages of differentiation that are within ±2 Ma of the formation of CAIs, with the exception of IVB irons that plot to systematically less radiogenic compositions yielding erroneously old ages. Secondary neutron capture due to galactic cosmic ray (GCR) irradiation is known to lower the ε182W of iron meteorites, adequate correction of which requires a measure of neutron dosage which has not been available, thus far. The W, Os and Pt isotope systematics of 12 of the 13 known IVB iron meteorites were determined by MC-ICP-MS (W, Os, Pt) and TIMS (Os). On the same dissolutions that yield precise ε182W, stable Os and Pt isotopes were determined as in situ neutron dosimeters for empirical correction of the ubiquitous cosmic-ray induced burn-out of 182W in iron meteorites. The W isotope data reveal a main cluster with ε182W of ∼−3.6, but a much larger range than observed in previous studies including irons (Weaver Mountains and Warburton Range) that show essentially no cosmogenic effect on their ε182W. The IVB data exhibits resolvable negative anomalies in ε189Os (−0.6ε) and complementary ε190Os anomalies (+0.4ε) in Tlacotepec due to neutron capture on 189Os which has approximately the same neutron capture cross section as 182W, and captures neutrons to produce 190Os. The least irradiated IVB iron, Warburton Range, has ε189Os and ε190Os identical to terrestrial values. Similarly, Pt isotopes, which are presented as ε192Pt, ε194Pt and ε196Pt range from +4.4ε to +53ε, +1.54ε to −0.32ε and +0.73ε to −0.20ε, respectively, also identify Tlacotepec and Dumont as the most GCR-damaged samples. In W–Os and W–Pt isotope space, the correlated isotope data back-project toward a 0-epsilon value of ε192Pt, ε189Os and ε190Os from which a pre-GCR irradiation ε182W of −3.42±0.09 (2σ) is derived. This pre-GCR irradiation ε182W is within uncertainty of the currently accepted CAI initial ε182W. The Pt and Os isotope correlations in the IVB irons are in good agreement with a nuclear model for spherical irons undergoing GCR spallation, although this model over-predicts the change of ε182W by ∼2×, indicating a need for better W neutron capture cross section determinations. A nucleosynthetic effect in ε184W in these irons of −0.14±0.08 is confirmed, consistent with the presence of Mo and Ru isotope anomalies in IVB irons. The lack of a non-GCR Os isotope anomaly in these irons requires more complex explanations for the production of W, Ru and Mo anomalies than nebular heterogeneity in the distribution of s-process to r-process nuclides.
Resumo:
OBJECTIVE: Human defensins and cathelicidins are a family of cationic antimicrobial peptides (AMPs), which play multiple roles in both innate and adaptive immune systems. They have direct antimicrobial activity against several microorganisms including burn pathogens. The majority of components of innate and adaptive immunity either express naturally occurring defensins or are otherwise chemoattracted or functionally affected by them. They also enhance adaptive immunity and wound healing and alter antibody production. All mechanisms to explain multiple functions of AMPs are not clearly understood. Prior studies to localize defensins in normal and burned skin using deconvolution fluorescence scanning microscopy indicate localization of defensins in the nucleus, perinuclear regions, and cytoplasm. The objective of this study is to further confirm the identification of HBD-1 in the nucleus by deconvolution microscopic studies involving image reconstruction and wire frame modeling. RESULTS: Our study demonstrated the presence of intranuclear HBD-1 in keratinocytes throughout the stratum spinosum by costaining with the nuclear probe DAPI. In addition, HBD-1 sequence does show some homology with known cationic nuclear localization signal sequences. CONCLUSION: To our knowledge, this is the first report to localize HBD-1 in the nuclear region, suggesting a role for this peptide in gene expression and providing new data that may help determine mechanisms of defensin functions.
Resumo:
OBJECTIVE To summarize the 2010 EFNS/MDS-ES evidence-based treatment recommendations for the management of Parkinson's disease (PD). This summary includes the treatment recommendations for early and late PD. METHODS For the 2010 publication, a literature search was undertaken for articles published up to September 2009. For this summary, an additional literature search was undertaken up to December 2010. Classification of scientific evidence and the rating of recommendations were made according to the EFNS guidance. In cases where there was insufficient scientific evidence, a consensus statement ('good practice point') is made. RESULTS AND CONCLUSIONS For each clinical indication, a list of therapeutic interventions is provided, including classification of evidence.
Resumo:
In modern medico-legal literature, only a small number of publications deal with fatal injuries from black powder guns. Most of them focus on the morphological features such as intense soot soiling, blast tattooing and burn effects in close-range shots or describe the wound ballistics of spherical lead bullets. Another kind of "unusual" and potentially lethal weapons are handguns destined for firing only blank cartridges such as starter and alarm pistols. The dangerousness of these guns is restricted to very close and contact range shots and results from the gas jet produced by the deflagration of the propellant. The present paper reports on a suicide committed with a muzzle-loading percussion pistol cal. 45. An unusually large stellate entrance wound was located in the precordial region, accompanied by an imprint mark from the ramrod and a faint greenish discoloration (apparently due to the formation of sulfhemoglobin). Autopsy revealed an oversized powder cavity, multiple fractures of the anterior thoracic wall as well as ruptures of the heart, the aorta, the left hepatic lobe and the diaphragm. In total, the zone of mechanical destruction had a diameter of approx. 15 cm. As there was no exit wound and no bullet lodged in the body, the injury was caused exclusively by the inrushing combustion gases of the propellant (black powder) comparable with the gas jet of a blank cartridge gun. In contact shots to ballistic gelatine using the suicide's pistol loaded with black powder but no projectile, the formation of a nearly spherical cavity could be demonstrated by means of a high-speed camera. The extent of the temporary cavity after firing with 5 g of black powder roughly corresponded to the zone of destruction found in the suicide's body.
Resumo:
This paper asks how World Trade Organization (WTO) panels and the Appellate Body (AB) take public international law (PIL) into account when interpreting WTO rules as a part of international economic law (IEL). Splendid isolation of the latter is not new; indeed it is intended by the negotiators of the Understanding on the Settlement of Disputes (DSU). At the same time, the Vienna Convention on the Law of Treaties (VCLT) is quite clear when it provides the general rules and the supplementary means of treaty interpretation. Despite such mandatory guidance, WTO adjudicators (when given a choice and assuming they see the conflict) prefer deference to WTO law over deference to Vienna and take a dogmatic way out of interpretation quandaries. The AB and panels make abundant reference to Vienna, though less so to substantive PIL. Often times, however, they do so simply in order to buttress their findings of violations of WTO rules. Perhaps tellingly, however, none of the reports in EC – Seals contains even a single mention of VCLT, despite numerous references to international standards addressing indigenous rights and animal welfare. In the longer term, and absent a breakthrough on the negotiation front, this pattern of carefully eschewing international treaty law and using PIL just for the sake of convenience could have serious consequences for the credibility and acceptance of the multilateral trading system. Following the adage ‘negotiate or litigate’ recourse to WTO dispute settlement increases when governments are less ready to make treaty commitments commensurate with the challenges of globalisation. This is true even for ‘societal choice’ cases on the margins of classic trade disputes. We will argue here that it is precisely for cases such as these that VCLT and PIL should be used more systematically by panels and the AB. Failing that, instead of building bridges for more coherent international regulation, WTO adjudicators could burn those same bridges which the DSU interpretation margin leaves open for accomplishing their job which is to find a ‘positive solution’. Worse, judicial incoherence could return to WTO dispute settlement like a boomerang and damage the credibility and thus the level of acceptance of the multilateral trading system per se.
Resumo:
OBJECTIVE Visual hallucinations (VHs) are a very personal experience, and it is not clear whether information about them is best provided by informants or patients. Some patients may not share their hallucinatory experiences with caregivers to avoid distress or for fear of being labeled insane, and others do not have informants at all, which limits the use of informant-based questionnaires. The aim of this study was to compare patient and caregiver views about VHs in Parkinson disease (PD), using the North-East Visual Hallucinations Interview (NEVHI). METHODS Fifty-nine PD patient-informant pairs were included. PD patients and informants were interviewed separately about VHs using the NEVHI. Informants were additionally interviewed using the four-item version of the Neuropsychiatric Inventory. Inter-reliability and concurrent validity of the different measures were compared. RESULTS VHs were more commonly reported by patients than informants. The inter-rater agreement between NEVHI-patient and NEVHI-informant was moderate for complex VHs (Cohen's kappa = 0.44; 95% confidence interval [CI]: 0.13-0.75; t = 3.43, df = 58, p = 0.001) and feeling of presence (Cohen's kappa = 0.35; 95% CI: 0.00-0.70; t = 2.75, df = 58, p = 0.006), but agreement was poor for illusions (Cohen's kappa = 0.25; 95% CI: -0.07-0.57; t = 2.36, df = 58, p = 0.018) and passage hallucinations (Cohen's kappa = 0.16; 95% CI: -0.04-0.36; t = 2.26, df = 58, p = 0.024). CONCLUSION When assessing VHs in PD patients, it is best to rely on patient information, because not all patients share the details of their hallucinations with their caregivers.
Resumo:
Introduction To meet the quality standards for high-stakes OSCEs, it is necessary to ensure high quality standardized performance of the SPs involved.[1] One of the ways this can be assured is through the assessment of the quality of SPs` performance in training and during the assessment. There is some literature concerning validated instruments that have been used to assess SP performance in formative contexts but very little related to high stakes contexts.[2], [3], [4]. Content and structure During this workshop different approaches to quality control for SPs` performance, developed in medicine, pharmacy and nursing OSCEs, will be introduced. Participants will have the opportunity to use these approaches in simulated interactions. Advantages and disadvantages of these approaches will be discussed. Anticipated outcomes By the end of this session, participants will be able to discuss the rationale for quality control of SPs` performance in high stakes OSCEs, outline key factors in creating strategies for quality control, identify various strategies for assuring quality control, and reflect on applications to their own practice. Who should attend The workshop is designed for those interested in quality assurance of SP performance in high stakes OSCEs. Level All levels are welcome. References Adamo G. 2003. Simulated and standardized patients in OSCEs: achievements and challenges:1992-2003. Med Teach. 25(3), 262- 270. Wind LA, Van Dalen J, Muijtjens AM, Rethans JJ. Assessing simulated patients in an educational setting: the MaSP (Maastricht Assessment of Simulated Patients). Med Educ 2004, 38(1):39-44. Bouter S, van Weel-Baumgarten E, Bolhuis S. Construction and validation of the Nijmegen Evaluation of the Simulated Patient (NESP): Assessing Simulated Patients' ability to role-play and provide feedback to students. Acad Med: Journal of the Association of American Medical Colleges 2012. May W, Fisher D, Souder D: Development of an instrument to measure the quality of standardized/simulated patient verbal feedback. Med Educ 2012, 2(1).
Resumo:
Objective: Visual hallucinations (VH) most commonly occur in eye disease (ED), Parkinson’s disease (PD), and Lewy body dementia (LBD). The phenomenology of VH is likely to carry important information about the brain areas within the visual system generating them. Methods: Data from five controlled cross-sectional VH studies (164 controls, 135 ED, 156 PD, 79 (PDD 48 + DLB 31) LBD) were combined and analysed. The prevalence, phenomenology, frequency, duration, and contents of VH were compared across diseases and gender. Results: Simple VH were most common in ED patients (ED 65% vs. LBD 22% vs. PD 9%, Chi-square [χ2] test: χ2=31.43, df=2, p<0.001), whilst complex VH were more common in LBD (LBD 76% vs. ED 38%, vs PD 28%, Chi-square test: χ2=96.80, df=2, p<0.001). The phenomenology of complex VH was different across diseases and gender. ED patients reported more “flowers” (ED 21% vs. LBD 6% vs. PD 0%, Chi-square test: χ2=10.04, df=2, p=0.005) and “body parts” (ED 40% vs. LBD 17% vs. PD 13%, Chi-square test: χ2=11.14, df=2, p=0.004); in contrast LBD patients reported “people” (LBD 85% vs. ED 67% vs. PD 63%, Chi-square test: χ2=6.20, df=2, p=0.045) and “animals/insects” (LBD 50% vs. PD 42% vs. ED 21%, Chi-square test: χ2=9.76, df=2, p=0.008). Males reported more “machines” (13 % vs. 2%, Chi-square test: χ2=6.94, df=1, p=0.008), whilst females reported more “family members/children” (48% vs. 29%, Chi-square test: χ2=5.10, df=1, p=0.024). Conclusions: The phenomenology of VH is likely related to disease specific dysfunctions within the visual system and to past, personal experiences.
Resumo:
OBJECTIVES Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. METHODS The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. RESULTS Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. CONCLUSIONS We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion.
Resumo:
Gebiet: Chirurgie Biomedizintechnik Biophysik Transplantationsmedizin Kardiologie Abstract: OBJECTIVES: – Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. – – METHODS: – The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. – – RESULTS: – Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. – – CONCLUSIONS: – We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion. – – © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Recurrent Nicolau syndrome associated with subcutaneous glatiramer acetate injection--a case report.
Resumo:
BACKGROUND Glatiramer acetate is worldwide used as first line treatment in relapsing remitting multiple sclerosis. Local skin reactions associated with glatiramer acetate are common, however, only isolated cases of severe local injection site reactions known as Nicolau Syndrome have been reported so far. CASE PRESENTATION We describe the case of a recurrent Nicolau Syndrome occurred during longstanding glatiramer acetate treatment in a woman with multiple sclerosis. The haemorrhagic patch necrotized and was treated locally as a deep second degree burn with excision of dead skin tissue and was healed. Treatment with glatiramer acetate was definitely suspended. CONCLUSIONS GA injections can be complicated by isolated or recurrent Nicolau Syndrome, a potentially life-threatening condition of which neurologists should be aware.
Resumo:
Workshop Overview The use of special effects (moulage) is a way to augment the authenticity of a scenario in simulation. This workshop will introduce different techniques of moulage (oil based cream colors, watercolors, transfer tattoos and 3D Prosthetics). The participants will have the opportunity to explore these techniques by applying various moulages. They will compare the techniques and discuss their advantages and disadvantages. Moreover, strategies for standardization and quality assurance will be discussed. Workshop Rationale Moulage supports the sensory perception in an scenario (1). It can provide evaluation clues (2) and help learners (and SPs) to engage in the simulation. However, it is of crucial importance that the simulated physical pathologies are represented accurate and reliable. Accuracy is achieved by using the appropriate technique, which requires knowledge and practice . With information about different moulage techniques, we hope to increases the knowledge of moulage during the workshop. By applying moulages in various techniques we will practice together. As standardization is critical for simulation scenarios in assessment (3, 4) strategies for standardization of moulage will be introduced and discussed. Workshop Objectives During the workshop participants will: - gain knowledge about different techniques of moulages - practice moulages in various techniques - discuss the advantages and disadvantages of moulage techniques - describe strategies for standardization and quality assurance of moulage Planned Format 5 min Introduction 15 min Overview – Background & Theory (presentation) 15 min Application of moulage for ankle sprain in 4 different techniques (oil based cream color, water color, temporary tatoo, 3D prosthetic) in small groups 5 min Comparing the results by interactive viewing of prepared moulages 15 min Application of moulages for burn in different techniques in small groups 5 min Comparing results the results by interactive viewing of prepared moulages 5 min Sharing experiences with different techniques in small groups 20 min Discussion of the techniques including standardization and quality assurance strategies (plenary discussion) 5 min Summary / Take home points