970 resultados para catheter


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Quasi-experimental study, prospective with quantitative approach, performed at the Hospital do Coração in Natal, aimed at verified the existence of difference between the care given by health professionals to the patients under mechanical ventilation (MV) in the Intensive Care Unit, before and after an educative intervention. The population was of 31 professionals, with data collected between november 05 of 2007 to march 27 of 2008. The results show a yong population, female gender, middle level of education, nursing technique, working between 05 and 09 years on nursing profession, and 01 to 04 years on Intensive Care Unit; almost all, never had an kind of training over prevent pneumonia associated to mechanical ventilation; from those that had training, occur on the work place with duration from 12 to 24 hours. About endotracheal intubation, the cuff was tested with a sterilized syringe had a positive change after a educative intervention, increased from 75,0% to 100,0%; the sterile guide was used on 75,0% before and 100,0% after an educative intervention. Regarding endotracheal suction procedure, was not informed to the patient on 72,7% before, however was informed on 56,7% after; the hands was not previously washed 68,5% before, however was 63,3% after the procedure; mask was used on 74,2 % opportunities before and 76,7% after; the aspiration catheter had adequated size on 98,9% observation before and 100,0% after; the gaze was sterilized on 95,7% before and 100,0% after; the ventilator was connected to the patient during the aspiration intervals on 94,4% observation before and 100,0% after; the ambu bag was clean and protected on 76,1% before and 85,7% after; the aspiration catheter was discarded after be used on 98,9% before and 100,0% after; FIO2 was turned to the begging value on 32,9% observation before and 12,0% after; before the procedure 71,9% professions washed their hands and 73,3% after; before, notes of aspiration results were performed on 70,8% observation and 86,7% after. Regarding devices used on respiratory tract, aspirator flasks were not swapped on 84,6% observations before and 71,0% after; daily látex extention change was not performed on 93,6% observation before and 87,1% after; the ambu bag change was not performed on 50,0% observation before even if was duty or unprotected and on 75,8% opportunities was changed, after; nebulization was not prepared with sterile fluids or manipulated aseptically on 65,2% observation before, perhaps was on 71,7% after; before nebulizers were not changed on 65,2% observations, perhaps were on 60,9% after. Concerning ventilator breathing circuits, condense fluids cumulated on circuits were removed on 55,0% opportunities before, and 64,0% after; moisturizer was not filled with sterile water when already had small amount of liquid inside on 78,4% observations before, and 90,2% after; MV circuits were changed on 97,0% observations on presence of visible duty or when presents some kind of failure, before and 98,4% after. About body position, on 51,3% observations the decubitus position change were done before and 78,2% after; fowler position was maitened on 95,5% observations before and 98,2% after; Regarding respiratory physiotherapy, enteral diet was not interrupted before respiratory physiotherapy on 94,9% before and 90,0% after; respiratory physiotherapy devices were not disinfected or sterile on 69,6% observations before but they re on 60,0% after; before the cateter was not tested before introduction enteral diet or medications on 100,0% but after was done on 15,2%. About enteral feeding, intestine motility and measure of stomach contents were not done on 100,0% observations before, but was 15,2% after. We conclude that 05 of 07 valuated procedures in relation to MV, had a significant improvement on quality of care given after educative intervention, when compared before intervention

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A descriptive, quantitative approach and non-participant observation study, which was aimed at analyzing the association between knowledge and practice of inclusion and maintenance of urinary catheter by nursing professionals in the occurrence of urinary tract infection, performed in the ICU of Onofre Lopes University Hospital in Natal / RN. The original sample was composed of 42 nursing staff professional, five (5) nurses and 37 nursing technicians, 27 of them were outsourced (FUNPEC and IEL fellows) and 10 servers UFRN. Data collection was performed using two instruments, the first observation procedures used in the insertion and manipulation of indwelling urinary catheter (IUC) and the second with a questionnaire that addressed the characterization data of respondents, knowledge and conduct the insertion and manipulation of the IUC. The results were tabulated in Microsoft Excel and analyzed using SPSS software, version 15.0. We found the prevalence of institutional staff members on outsourcing - IEL and FUNPEC - (64.3%) were female (69.0%), aged 21 to 35 years (59.5%) and with mid-level education (88.1%). As to knowledge, we found that the nurses had levels of good to excellent and the nursing technicians, to regulate the poor. The nurses made a mistake when choosing IUC (40.0%) and washing hands (30.0%) and technicians on hand washing (74.4%) and the contents of the tray (34.7%). In relation to the conduct of insertion of IUC, the nurses made a mistake when choosing SVD (66.7%) and washing hands (57.1%). Regarding the handling of IUC/drainage system, the technicians were wrong more about washing their hands (56.0%). Analyzing the misconduct to the categorization of knowledge, we saw that the nursing staff who had missed more had inadequate knowledge (ρ = 0.001). At the end we found the risk of a patient to acquire UTI is higher in two and a half times when there is a large number of mismatches, patient spends more time using the IUC and hospitalized in the ICU. As regards the study hypotheses, we accept the alternative hypothesis and reject the null hypothesis proposed at the start of this research, where the number of gaps in knowledge and behavior increases the incidence of urinary tract infection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In recent decades, the search for quality care has been widely discussed by the institutions and health professionals. In this context, it is the nurse coordinator of the process of providing nursing staff, reflecting the commitment to quality of care. In this process, it is the appearance of Infections Related to health care and its potential association with the workload in nursing as a valuable indicator of quality of care. Thus, this research contributes to studies to characterize the demand of nursing work to promote a safe healthcare practice. This study aimed to identify the association of nursing workload with the number of cases of Ventilator-Associated Pneumonia, urinary tract infection and central venous catheter infection in the intensive care unit. This is a quantitative research approach, descriptive, cross-sectional and prospective, held at Unimed Hospital in Natal-RN. The study population consisted of all patients treated in the Intensive Care Unit, Hospital for a period of 90 consecutive days in 2011. The convenience sample was compostapelos patients admitted to the ICU during the period of data collection, a total sample of 286 patients. To perform the data analysis software were used: Statistica 6.0, SPPS (Statistical Package for Social Sciences) version 17.0 (2004) and Excel 2007. In the descriptive analysis, we used Measures of Central Tendency and Measures of Dispersion or Variability and the use of nonparametric tests. Of the 286 patients, 88 were from the ICU and 198 ICU II II. Males predominated in the ICU I (51.1%) and female ICU II (57.6%) patients in the ICU I were aged 61-80 years (39.8%) followed by greater than 80 years (39.8%). In the ICU II, most of the patients were aged 61-80 years (38.9%) and then from 41 to 60 years (24.2%). In relation to the class of TISS inlet predominant class II in the two ICUs (59.1%), followed by Class III also in the two units (34.6%). Most patients (70.6%) out of the ICUs belonging to class II TISS. In the ICU I, the average number of forms of the TISS 28 was 6, has in ICU II this value drops to 3.2 forms. The overall mean was 19.9 TISS points in ICU patients I and ICU II.the 17 points in the average hours required to provide adequate nursing care to patients in the ICU I found that is 10 , 7 hours, and the ICU II 9.2 hours. It was found that the time provided by the nursing staff were higher in ICU II, with an average of 19 hours available for nurses in this sector. In the ICU I, which showed higher need of available hours, it was found that the mean value of 12.7 available hours. It was found that only 2.4% of patients had these units Ventilator-Associated Pneumonia, 1.0% were infected central venous catheter and 1.4% of patients had urinary tract infection. Infection associated with health care occurs, on average, on the tenth day of hospitalization. In the ICU II, this average value extends to the twelfth day with an excess of 2.7 hours of nursing care while in ICU I value decays to the ninth day of hospitalization with a deficiency of 12-hour assistance. It is concluded that patients generally showed a need for classification of semi-intensive care and has been assisted in their need to load. As for his association with the Related Infections Health will assist this analysis could not be performed due to the small number of notifications in this period. It is suggested further study how other factors related to infections me a longer period of analysis

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study investigates adrenergic regulation of the systemic and pulmonary circulations of the anaesthetised South American rattlesnake, Crotalus durissus. Haemodynamic measurements were made following bolus injections of adrenaline and adrenergic antagonists administered through a systemic arterial catheter. Adrenaline caused a marked systemic vasoconstriction that was abolished by phentolamine, indicating this response was mediated through alpha-adrenergic receptors. Injection of phentolamine gave rise to a pronounced vasodilatation (systemic conductance (G(sys)) more than doubled), while injection of propranolol caused a systemic vasoconstriction, pointing to a potent alpha-adrenergic, and a weaker beta-adrenergic tone in the systemic vasculature of Crotalus. Overall, the pulmonary vasculature was far less responsive to adrenergic stimulation than the systemic circulation. Adrenaline caused a small but non-significant pulmonary vasodilatation and there was tendency of reducing this dilatation after either phentolamine or propranolol. Injection of phentolamine increased pulmonary conductance (G(pul)), while injection of propranolol produced a small pulmonary constriction, indicating that alpha-adrenergic and beta-adrenergic receptors contribute to a basal regulation of the pulmonary vasculature. Our results suggest adrenergic regulation of the systemic vasculature, rather than the pultrionary, may be an important factor in the development of intracardiac shunts. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho teve como objetivo estudar as alterações microvasculares intraneurais aguda em nervo isquiático de rato submetido a esmagamento por diferentes cargas. Foram utilizados 60 ratos machos da linhagem Wistar, distribuídos em grupos experimentais de acordo com a injeção de vasos e com a carga de esmagamento. Os nervos isquiáticos direitos foram isolados e submetidos ao esmagamento com cargas (0,5 Kg, 1 Kg, 5 Kg, 10 kg e 15 kg) por 10 minutos e os nervos isquiáticos esquerdos foram utilizados como controle. Após esmagamento, os animais foram submetidos à cateterização da aorta abdominal e injeção dos vasos, em seguida 30 nervos direitos e esquerdos foram fixados em formol 10%, desidratados e diafanizados para análise longitudinal dos vasos intraneurais e os restantes retirados em toda a sua extensão, cortados em 3 fragmentos, congelados em isopentano em gelo seco e armazenados em freezer -70°C, seccionados transversalmente para análise e contagem dos vasos intraneurais. As análises macroscópica e microscópica mostraram regiões de hematoma endoneural e epineural nas diferentes cargas de esmagamento. A análise morfométrica sugere que a lesão aos vasos intraneurais foi proporcional à carga de esmagamento, causando hematoma endoneural e epineural, que cria microambiente desfavorável para a regeneração das fibras nervosas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cateteres venosos centrais inseridos em pacientes internados em unidade de terapia intensiva foram avaliados por métodos microbiológicos (cultura semi-quantitativa) e microscopia eletrônica de varredura a fim de detectar adesão microbiana e correlacionar com a cultura de sangue. Durante o período de estudo, foram avaliados 59 pacientes com cateter venoso central. A idade dos pacientes, sexo, sítio de inserção e tempo de permanência do cateter foram anotados. O cateter era de poliuretano não tunelizado e de único lúmen. O sangue para cultura foi coletado no momento da remoção do cateter. de 63 pontas de cateteres, 30 (47,6%) foram colonizadas e a infecção encontrada em 5 (23,8%) cateteres. A infecção foi mais prevalente em 26 pacientes (41,3%) com cateteres inseridos em veia subclávia do que nos 3 (3,2%) inseridos em veia jugular. A infecção foi observada com mais freqüência em cateteres com tempo de permanência maior do que sete dias. Os microrganismos isolados incluíram 32 estafilococos coagulase-negativa (29,7%), 61 bactérias Gram-negativas (52,9%), 9 estafilcocos coagulase-positiva (8,3%) e 3 leveduras (2,7%). Como agentes causais de infecções em unidade de terapia intensiva foram isolados E. aerogenes, P. aeruginosa, A. baumannii. Os antimicrobianos com maior atividade in vitro contra as bactérias Gram-negativas foram o imipenem e contra as Gram-positivas vancomicina, cefepime, penicilina, rifampicina e tetraciclina. As análises por microscopia eletrônica de varredura revelaram biofilmes sobre a superfície de todos os cateteres examinados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As infecções devido a biofilmes bacterianos são comuns em pacientes sob tratamento em hemodiálise. Neste estudo, 16 pacientes (7 homens, 9 mulheres, de 22 a 81 anos, média 50 anos de idade), com um total de 25 cateteres de hemodiálise (3 de triplo-lúmen e 22 de duplo-lúmen) de poliuretano inseridos em veia subclávia foram estudados. Os cateteres permaneceram no local de 3 a 91 dias (média de 47 dias). Os cateteres foram removidos devido ao: mau funcionamento (44%), suspeita de infecção relacionada ao cateter (20%), viabilidade de um acesso permanente (16%), remoção acidental (12%), sinais e sintomas de infecção no local da inserção do cateter (4%) e contaminação exógena (4%). Culturas positivas de ponta foram observadas em sete cateteres (28%), concomitantemente com três culturas positivas de sangue. Das culturas de sangue foram identificados Staphylococcus aureus (12%) e de uma das conexões foi isolado S. aureus. Biofilmes foram observados sobre todas as pontas de cateteres. Os S. aureus isolados do sangue e cateter (ponta e conexão) eram resistentes a pencilina e sensíveis a azitromicina, ciprofloxacina, clindamicina, cloranfenicol, gentamicina, oxacilina, rifampicina, sulfametoxazole, tetraciclina e vancomicina. As cepas de S. aureus isoladas de sangue, ponta de cateter e conexão foram consideradas idênticas devido à coincidência do perfil de sensibilidade. E similaridade genética, avaliada por meio de ribotipagem.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: Complicações neurológicas da anestesia subaracnóidea, apesar de raras, podem determinar seqüelas importantes. O objetivo deste estudo é apresentar estas complicações com a finalidade de esclarecer os fatores desencadeantes, o que facilita o diagnóstico das lesões. CONTEÚDO: São apresentadas as seguintes complicações: lesão de nervo desencadeada pela agulha e cateter, cefaléia pós-punção, síndrome da artéria espinhal anterior, hematoma espinhal, meningite bacteriana, meningite asséptica, aracnoidite adesiva, síndrome da cauda eqüina e sintomas neurológicos transitórios. CONCLUSÕES: O conhecimento dos fatores desencadeantes de complicações neurológicas determinadas pela anestesia subaracnóidea pode prevenir as lesões, diagnosticar e tratar mais precocemente e, desse modo, mudar o prognóstico das mesmas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: O número de artroplastia total de quadril (ATQ) bilateral tem aumentado a cada ano. Analgesia pós-operatória pela infusão contínua perineural com anestésico local tem se mostrado favorável quando comparada com analgesia sistêmica. O uso de bombas elastoméricas tem aumentado a satisfação do paciente quando em comparação com os modelos eletrônicos. O objetivo deste relato foi descrever um caso de analgesia contínua bilateral do plexo lombar via posterior, com infusão contínua através de bomba elastomérica, em paciente submetido à uma artroplastia bilateral de quadril. RELATO do CASO: Paciente feminina, 46 anos, 65 kg, 162 cm, com artrite reumatoide e hipertensão arterial, estado físico ASA II, escalada para ser submetida a ATQ bilateral em um único estágio. Uso de corticosteroide por 13 anos. Hemoglobina = 10,1 g.dL-1, hematócrito = 32,7%. Monitoração de rotina. Raquianestesia com 15 mg de bupivacaína 0,5% isobárica. Anestesia geral com propofol (PFS) e remifentanil e intubação sem bloqueadores neuromusculares. ATQ direita e no final, bloqueio plexo lombar com estimulador e conjunto agulha 150 mm e injeção de 20 mL bupivacaína 0,2% e passagem de cateter. ATQ esquerda e, no final, mesmo procedimento. Estudado dispersão do anestésico e contraste. Instalado bomba elastomérica com bupivacaína 0,1% (400 mL) em velocidade de 14 mL.h-1. Transferida para Unidade de Cuidados Intensivos (UCI). Vinte e quatro horas após, nova bomba com a mesma solução. Nenhum bolus durante 50 horas. Após remoção de cateter, dor controlada por via oral com cetoprofeno e dipirona. CONCLUSÕES: O bloqueio bilateral contínuo periférico com infusão de bupivacaína a 0,1% com bombas elastoméricas é um procedimento seguro e efetivo em adultos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A hemodiálise é uma modalidade terapêutica que pode sustentar a vida do paciente com insuficiência renal aguda (IRA), enquanto este recupera a função renal. Para sua realização, é necessário estabelecer circulação extracorpórea, para que seja realizada a filtração do sangue, impondo a necessidade de um acesso vascular viável e eficiente. O objetivo deste estudo foi avaliar a eficiência e as complicações do acesso vascular para hemodiálise (HD), com cateter temporário de duplo lúmen inserido na veia jugular externa. Foram estudados 10 cães com IRA induzida por gentamicina, submetidos a sessões diárias de HD, com duração de uma hora, até a recuperação da função renal ou óbito. Foram realizadas 104 sessões de HD nos animais estudados, observando-se necessidade de troca do cateter em sete sessões (6,7%), devido à obstrução do lúmen do cateter em seis sessões (5,8%) ou por saída acidental do mesmo em uma sessão (1,0%). Não se observou migração do cateter, infecção, hemorragia ou hematoma no local de entrada do cateter na pele, obtendo-se fluxo sanguíneo patente em 90,4% das sessões. Concluiu-se que o acesso vascular na veia jugular externa com cateter temporário de duplo-lúmen mostrou-se viável, com ocorrência de poucas complicações, sendo, portanto, indicado como forma de acesso para a circulação extracorpórea para HD em cães com IRA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Peritoneal dialysis (PD) is a simple, safe, cheap, and efficient renal replacement therapy method. It can correct metabolic disorders and fluid overload in acute kidney injury (AKI) patients both in and out of the intensive care unit. Use of PD in AKI is enhanced by placement of a Tenckhoff catheter, which can be safely accomplished at the bedside. Some PD modalities, such as high-volume PD and continuous-flow PD, can provide dialysis doses and efficiency comparable to extracorporeal blood purification methods. PD is particularly suitable for neonates, children, and patients with refractory heart failure or who are otherwise hemodynamically unstable. PD should be considered in situations where systemic anticoagulation and/or vascular access are problematic. PD is limited by a lower efficiency that may produce inadequate renal replacement in larger and/or severely hypercatabolic patients. Fluid removal can be unpredictable, there is a risk of infection, and possible issues with mechanical ventilation. In this article, we discuss the use of PD in AKI, with emphasis on recent advances. Copyright (c) 2012 S. Karger AG, Basel