803 resultados para building or renovating a home
Resumo:
There is growing pressure on the construction industry to deliver energy efficient, sustainable buildings but there is evidence to suggest that, in practice, designs regularly fail to achieve the anticipated levels of in-use energy consumption. One of the key factors behind this discrepancy is the behavior of the building occupants. This paper explores how insights from experimental psychology could potentially be used to reduce the gap between the predicted and actual energy performance of buildings. It demonstrates why traditional methods to engage with the occupants are not always successful and proposes a model for a more holistic approach to this issue. The paper concludes that achieving energy efficiency in buildings is not solely a technological issue and that the construction industry needs to adopt a more user-centred approach.
Resumo:
Design summer years representing near-extreme hot summers have been used in the United Kingdom for the evaluation of thermal comfort and overheating risk. The years have been selected from measured weather data basically representative of an assumed stationary climate. Recent developments have made available ‘morphed’ equivalents of these years by shifting and stretching the measured variables using change factors produced by the UKCIP02 climate projections. The release of the latest, probabilistic, climate projections of UKCP09 together with the availability of a weather generator that can produce plausible daily or hourly sequences of weather variables has opened up the opportunity for generating new design summer years which can be used in risk-based decision-making. There are many possible methods for the production of design summer years from UKCP09 output: in this article, the original concept of the design summer year is largely retained, but a number of alternative methodologies for generating the years are explored. An alternative, more robust measure of warmth (weighted cooling degree hours) is also employed. It is demonstrated that the UKCP09 weather generator is capable of producing years for the baseline period, which are comparable with those in current use. Four methodologies for the generation of future years are described, and their output related to the future (deterministic) years that are currently available. It is concluded that, in general, years produced from the UKCP09 projections are warmer than those generated previously. Practical applications: The methodologies described in this article will facilitate designers who have access to the output of the UKCP09 weather generator (WG) to generate Design Summer Year hourly files tailored to their needs. The files produced will differ according to the methodology selected, in addition to location, emissions scenario and timeslice.
Resumo:
The Chartered Institute of Building Service Engineers (CIBSE) produced a technical memorandum (TM36) presenting research on future climate impacting building energy use and thermal comfort. One climate projection for each of four CO2 emissions scenario were used in TM36, so providing a deterministic outlook. As part of the UK Climate Impacts Programme (UKCIP) probabilistic climate projections are being studied in relation to building energy simulation techniques. Including uncertainty in climate projections is considered an important advance to climate impacts modelling and is included in the latest UKCIP data (UKCP09). Incorporating the stochastic nature of these new climate projections in building energy modelling requires a significant increase in data handling and careful statistical interpretation of the results to provide meaningful conclusions. This paper compares the results from building energy simulations when applying deterministic and probabilistic climate data. This is based on two case study buildings: (i) a mixed-mode office building with exposed thermal mass and (ii) a mechanically ventilated, light-weight office building. Building (i) represents an energy efficient building design that provides passive and active measures to maintain thermal comfort. Building (ii) relies entirely on mechanical means for heating and cooling, with its light-weight construction raising concern over increased cooling loads in a warmer climate. Devising an effective probabilistic approach highlighted greater uncertainty in predicting building performance, depending on the type of building modelled and the performance factors under consideration. Results indicate that the range of calculated quantities depends not only on the building type but is strongly dependent on the performance parameters that are of interest. Uncertainty is likely to be particularly marked with regard to thermal comfort in naturally ventilated buildings.
Resumo:
Novel bis(azidophenyl)phosphole sulfide building block 8 has been developed to give access to a plethora of phosphole-containing π-conjugated systems in a simple synthetic step. This was explored for the reaction of the two azido moieties with phenyl-, pyridyl- and thienylacetylenes, to give bis(aryltriazolyl)-extended π-systems, having either the phosphole sulfide (9) or the phosphole (10) group as central ring. These conjugated frameworks exhibit intriguing photophysical and electrochemical properties that vary with the nature of the aromatic end-group. The λ3-phospholes 10 display blue fluorescence (λem = 460–469 nm) with high quan-tum yield (ΦF = 0.134–0.309). The radical anion of pyridylsubstituted phosphole sulfide 9b was observed with UV/Vis spectroscopy. TDDFT calculations on the extended π-systems showed some variation in the shape of the HOMOs, which was found to have an effect on the extent of charge transfer, depending on the aromatic end-group. Some fine-tuning of the emission maxima was observed, albeit subtle, showing a decrease in conjugation in the order thienyl � phenyl � pyridyl. These results show that variations in the distal ends of such π-systems have a subtle but significant effect on photophysical properties.
Resumo:
There is potential to reduce both operational and embodied greenhouse gas emission from buildings. To date the focus has been on reducing the operational element, although given the urgency of carbon reductions, it may be more beneficial to consider upfront embodied carbon reductions. This paper describes a case study on the whole life carbon cycle of a warehouse building in Swindon, UK. It examines the relationship between embodied carbon (Ec) and operational carbon (Oc), the proportions of Ec from the structural and non-structural elements, carbon benchmarking of the structure, the value of ‘cradle to site’ or ‘cradle to grave’ assessments and the significance of the timing of emissions during the life of the building. The case study indicates that Ec was dominant for the building and that the structure was responsible for more than half of the Ec. Weighting of future emissions appears to be an important factor to consider. The PAS 2050 reduction factors had only a modest effect but weighting to allow for future decarbonisation of the national grid energy supply had a large effect. This suggests that future operational carbon emissions are being overestimated compared to embodied.
Resumo:
The chapter examines the compex roles of corruption in state-buioding environments. The first section briefly outlines how statebuilding is conceptualized in this discussion. The second section examines the concept of corruption,and argues that the organization, rather than the scale of corruption, offers a better lens through which its impact can be analyzed. The third section examines the complex relationship between corruption and statebuilding through the lenses of two key aspects of statebuilding – elite settlements, and the provision of public services – and briefly discusses both the complex relationship between corruption and security, and the impact of aid on corruption in statebuilding environments. The fourth section concludes the chapter with a reflection on the implications of the analysis for understanding contemporary statebuilding efforts and policy.
Resumo:
The chapter examines the impact of international statbuilding efforts on political and economic dynamics in Kosovo from 1999 to 2011
Resumo:
Purpose – The aim of this paper is to present a conceptual valuation framework to allow telecare service stakeholders to assess telecare devices in the home in terms of their social, psychological and practical effects. The framework enables telecare service operators to more effectively engage with the social and psychological issues resulting from telecare technology deployment in the home and to design and develop appropriate responses as a result. Design/methodology/approach – The paper provides a contextual background for the need for sociologically pitched tools that engage with the social and cultural feelings of telecare service users before presenting the valuation framework and how it could be used. Findings – A conceptual valuation framework is presented for potential development/use. Research limitations/implications – The valuation framework has yet to be extensively tested or verified. Practical implications – The valuation framework needs to be tested and deployed by a telecare service operator but the core messages of the paper are valid and interesting for readership. Social implications – In addressing the social and cultural perspectives of telecare service stakeholders, the paper makes a link between the technologies in the home, the feelings and orientations of service users (e.g. residents, emergency services, wardens, etc.) and the telecare service operator. Originality/value – The paper is an original contribution to the field as it details how the sociological orientations of telecare technology service users should be valued and addressed by service operators. It has a value through the conceptual arguments made and through valuation framework presented.
Resumo:
Building assessment methods have become a popular research field since the early 1990s. An international tool which allows the assessment of buildings in all regions, taking into account differences in climates, topographies and cultures does not yet exist. This paper aims to demonstrate the importance of criteria and sub-criteria in developing a new potential building assessment method for Saudi Arabia. Recently, the awareness of sustainability has been increasing in developing countries due to high energy consumption, pollution and high carbon foot print. There is no debate that assessment criteria have an important role to identify the tool’s orientation. However, various aspects influence the criteria and sub-criteria of assessment tools such as environment, economic, social and cultural to mention but a few. The author provides an investigation on the most popular and globally used schemes: BREEAM, LEED, Green Star, CASBEE and Estidama in order to identify the effectiveness of the different aspects of the assessment criteria and the impacts of these criteria on the assessment results; that will provide a solid foundation to develop an effective sustainable assessment method for buildings in Saudi Arabia. Initial results of the investigation suggest that each country needs to develop its own assessment method in order to achieve desired results, while focusing upon the indigenous environmental, economic, social and cultural conditions. Keywords: Assessment methods, BREEAM, LEED, Green Star, CASBEE, Estidama, sustainability, sustainable buildings, Environment, Saudi Arabia.
Resumo:
Forests are a store of carbon and an eco-system that continually removes carbon dioxide from the atmosphere. If they are sustainably managed, the carbon store can be maintained at a constant level, while the trees removed and converted to timber products can form an additional long term carbon store. The total carbon store in the forest and associated ‘wood chain’ therefore increases over time, given appropriate management. This increasing carbon store can be further enhanced with afforestation. The UK’s forest area has increased continually since the early 1900s, although the rate of increase has declined since its peak in the late 1980s, and it is a similar picture in the rest of Europe. The increased sustainable use of timber in construction is a key market incentive for afforestation, which can make a significant contribution to reducing carbon emissions. The case study presented in this paper demonstrates the carbon benefits of a Cross Laminated Timber (CLT) solution for a multi-storey residential building in comparison with a more conventional reinforced concrete solution. The embodied carbon of the building up to completion of construction is considered, together with the stored carbon during the life of the building and the impact of different end of life scenarios. The results of the study show that the total stored carbon in the CLT structural frame is 1215tCO2 (30tCO2 per housing unit). The choice of treatment at end of life has a significant effect on the whole life embodied carbon of the CLT frame, which ranges from -1017 tCO2e for re-use to +153tCO2e for incinerate without energy recovery. All end of life scenarios considered result in lower total CO2e emissions for the CLT frame building compared with the reinforced concrete frame solution.
Resumo:
Existing buildings contribute greatly to global energy use and greenhouse gas emissions. In the UK, about 18% of carbon emissions are generated by non-domestic buildings; sustainable building refurbishment can play an important role in reducing carbon emissions. This paper looks at the performance of a recently refurbished 5-storey office building in London, in terms of energy consumption as well as occupants’ satisfaction. Pre- and post-occupancy evaluation studies were conducted using online questionnaire surveys and energy consumption evaluation. Results from pre-occupancy and post-occupancy evaluation studies showed that employees, in general, were more satisfied with their work environment at the refurbished building than with that of their previous office. Employees’ self-reported productivity improved after the move to Elms House. These surveys showed a positive relationship between employees’ satisfaction with their work environment and their self-reported productivity, well-being and enjoyment at work. The factor that contributed to increasing employee satisfaction the most was: better use of interior space. Although the refurbishment was a success in terms of reducing energy consumption per m2, the performance gap was almost 3 times greater than that estimated. Unregulated loads, problems with building control, ineffective use of space and occupants’ behaviour are argued to be reasons for this gap.