986 resultados para beam-foil technique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the results of the static and dynamic testing of a three-span continuous I-beam highway bridge. Live load stress frequency curves for selected points are shown, and the static and dynamic load distribution to the longitudinal composite beam members are given. The bridge has four traffic lanes with a roadway width of 48 ft. Six longitudinal continuous WF beams act compositely with the reinforced concrete slab to carry the live load. The beams have partial length cover plates at the piers. Previous research has indicated that beams with partial length cover plates have a very low fatigue strength. It was found in this research that the magnitude of the stresses due to actual highway loads were very much smaller than those computed from specification loading. Also, the larger stresses which were measured occurred a relatively small number of times. These data indicate that some requirements for reduced allowable stresses at the ends of cover plates are too conservative. The load distribution to the longitudinal beams was determined for static and moving loads and includes the effect of impact on the distribution. The effective composite section was found at various locations to evaluate the load distribution data. The composite action was in negative as well as positive moment regions. The load distribution data indicate that the lateral distribution of live load is consistent with the specifications, but that there is longitudinal distribution, and therefore the specifications are too conservative.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report neovascular glaucoma after proton-beam radiotherapy of an adenocarcinoma of the pigmented ciliary epithelium and its successful treatment by iridocyclectomy. PATIENT AND METHODS: A 65-year-old man developed neovascular glaucoma 10 months after proton-beam radiotherapy of a small pigmented iridociliary tumour with a clinical differential diagnosis of uveal melanoma or adenocarcinoma. The diagnosis of 'toxic tumour syndrome' was made, and iridocyclectomy performed. RESULTS: Histopathology and immunohistochemistry of the specimen diagnosed an adenocarcinoma of the pigmented ciliary epithelium, with the presence of mitoses suggesting residual viable tumour cells. The rubeosis regressed, with normalization of the intraocular pressure. Phacoemulsification for radiation-induced cataract restored VA to 6/9, which was better than that recorded at initial referral, the patient having longstanding cellophane maculopathy. CONCLUSIONS: Neovascular glaucoma after radiotherapy of a small, pigmented, ciliary body tumour raises the possibility of adenocarcinoma. This 'toxic tumour syndrome' may respond to iridocyclectomy of the irradiated tumour.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Sclerotherapy of telangiectasias and reticular leg veins can be unpleasant and painful for some patients. OBJECTIVE: To determine pain level with two different sclerotherapy techniques in a prospective randomized trial. METHODS: Patients with symmetrical telangiectasias and reticular veins on both legs (C(1A) or (S)E(P)A(S)P(N1) were randomized to the standard (successive injections of chromated glycerin mixed with one-third lidocaine-epinephrine 1%) or two-step technique (first treating only reticular veins with a single injection at the base of each cluster of telangiectasias and then successively injecting all remaining telangiectasias a few minutes later. Pain was assessed using a 100-point visual analogue scale (0 = no pain, 100 = maximum pain). RESULTS: Data from 53 consecutive patients could be evaluated. The two-step technique was significantly less painful (28.2) than the standard technique (40.6, p < .001). CONCLUSION: The two-step technique with chromated glycerin mixed with one-third lidocaine-epinephrine 1% significantly reduces sclerotherapy pain. This may be a useful technique for patients who are particularly sensitive or afraid of sclerotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To analyze available evidence on the incidence of anatomical variations or disease of the maxillary sinuses as identified by cone beam computed tomography (CBCT) in dentistry. MATERIALS AND METHODS: A focused question was developed to search the electronic databases MEDLINE, EMBASE, the Cochrane Oral Health Group Trials Register, and CENTRAL and identify all relevant papers published between 1980 and January 19, 2013. Unpublished literature at ClinicalTrials.gov, in the National Research Register, and in the Pro-Quest Dissertation Abstracts and Thesis database was also included. Studies were included irrespective of language. These results were supplemented by hand and gray literature searches. RESULTS: Twenty-two studies were identified. Twenty were retrospective cohort studies, one was a prospective cohort study, and one was a case control study. The main indication for CBCT was dental implant treatment planning, and the majority of studies used a small field of view for imaging. The most common anatomical variations included increased thickness of the sinus membrane, the presence of sinus septa, and pneumatization. Reported sinus disease frequency varied widely, ranging from 14.3% to 82%. There was a wide range in the reported prevalence of mucosal thickening related to apical pathology, the degree of lumenal opacification, features of sinusitis, and the presence of retention cysts and polyps. More pathologic findings in the maxillary sinus were reported in men than in women, and the medial wall and sinus floor were most frequently affected. CONCLUSION: CBCT is used primarily to evaluate bony anatomy and to screen for overt pathology of the maxillary sinuses prior to dental implant treatment. Differences in the classification of mucosal findings are problematic in the consistent and valid assessment of health and disease of the maxillary sinus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose to evaluate automatic three-dimensional gray-value rigid registration (RR) methods for prostate localization on cone-beam computed tomography (CBCT) scans. In total, 103 CBCT scans of 9 prostate patients have been analyzed. Each one was registered to the planning CT scan using different methods: (a) global RR, (b) pelvis bone structure RR, (c) bone RR refined by local soft-tissue RR using the CT clinical target volume (CTV) expanded with a 1, 3, 5, 8, 10, 12, 15 or 20-mm margin. To evaluate results, a radiation oncologist was asked to manually delineate the CTV on the CBCT scans. The Dice coefficients between each automatic CBCT segmentation - derived from the transformation of the manual CT segmentation - and the manual CBCT segmentation were calculated. Global or bone CT/CBCT RR has been shown to yield insufficient results in average. Local RR with an 8-mm margin around the CTV after bone RR was found to be the best candidate for systematically significantly improving prostate localization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solid phase microextraction (SPME) has been widely used for many years in various applications, such as environmental and water samples, food and fragrance analysis, or biological fluids. The aim of this study was to suggest the SPME method as an alternative to conventional techniques used in the evaluation of worker exposure to benzene, toluene, ethylbenzene, and xylene (BTEX). Polymethylsiloxane-carboxen (PDMS/CAR) showed as the most effective stationary phase material for sorbing BTEX among other materials (polyacrylate, PDMS, PDMS/divinylbenzene, Carbowax/divinylbenzene). Various experimental conditions were studied to apply SPME to BTEX quantitation in field situations. The uptake rate of the selected fiber (75 μm PDMS/CAR) was determined for each analyte at various concentrations, relative humidities, and airflow velocities from static (calm air) to dynamic (>200 cm/s) conditions. The SPME method also was compared with the National Institute of Occupational Safety and Health method 1501. Unlike the latter, the SPME approach fulfills the new requirement for the threshold limit value-short term exposure limit (TLV-STEL) of 2.5 ppm for benzene (8 mg/m3).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report magnetic and magneto-optical measurements of two Mn12 single-molecule magnet derivatives isolated in organic glasses. Field-dependent magnetic circular dichroism (MCD) intensity curves (hysteresis cycles) are found to be essentially identical to superconducting quantum interference device magnetization results and provide experimental evidence for the potential of the optical technique for magnetic characterization. Optical observation of magnetic tunneling has been achieved by studying the decay of the MCD signal at weak applied magnetic field

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multi-phase postmortem CT angiography (MPMCTA) is recognized as a valuable tool to explore the vascular system, with higher sensitivity than conventional autopsy. However, a limitation is the impossibility to diagnose pulmonary embolism (PE) due to post-mortem blood clots situated in pulmonary arteries. The purpose of this study was to explore an eventual possibility to distinguish between real PE and artefacts mimicking PE. Our study included 416 medico-legal cases. All of them underwent MPMCTA, conventional autopsy and histological examination. We selected cases presenting arterial luminal filling defects in the pulmonary arteries. Their radiological interpretation was confronted to the one of autopsy and histological examination. We also investigated an eventual correlation between artefacts in pulmonary arteries and those in other parts of the vascular system. In 123 cases, filling defects of pulmonary arteries were described during MPMCTA. In 57 cases, this was interpreted as artefact and in 4 cases as suspected PE. In 62 cases only a differential diagnosis was made. Autopsy and histology could clearly identify the artefacts as such. Only one case of real PE was radiologically misinterpreted as artefact. In 6 of the 62 cases with no interpretation a PE was diagnosed. In 3 out of 4 suspected cases, PE was confirmed. We found out that filling defects in pulmonary arteries are nearly always associated to other vascular artefacts. Therefore, we suggest following some rules for radiological interpretation in order to allow a reliable diagnosis of pulmonary embolism after MPMCTA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Gastric banding still represents one of the most widely used bariatric procedures. It provides acceptable weight loss in many patients, but has frequent long-term complications. Because different types of bands may lead to different results, we designed a randomized study to compare the Lapband® with the SAGB®. We hereby report on the long-term results. METHODS: Between December 1998 and June 2002, 180 morbidly obese patients were randomized between Lapband® or SAGB®. Weight loss, long-term morbidity, and need for reoperation were evaluated. RESULTS: Long-term weight loss did not differ between the two bands. Patients who maintained their band had an acceptable long-term weight loss of between 50 and 60 % EBMIL. In both groups, about half the patients developed long-term complications, with about 50 % requiring major redo surgery. There was no difference in the overall rates of long-term complications or failures between the two groups, but patients who had a Lapband® were significantly more prone to develop band slippage/pouch dilatation (13.3 versus 0 %, p < 0,001). CONCLUSIONS: Although in the absence of complication, gastric banding leads to acceptable weight loss; the long-term complication and major reoperation rates are very high independently from the type of band used or on the operative technique. Gastric banding leads to relatively poor overall long-term results and therefore should not be considered the procedure of choice for the treatment of morbid obesity. Patients should be informed of the limited overall weight loss and the very high complication rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Yhteenveto: Käytännöllinen oikeanpuoleinen viiltogastropeksia mahalaukun laajentumisen ja kiertymisen hoitona tai ennaltaehkäisynä

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new technique capable of obtaining quantitative values of the rotation angle of the polarization vector by using holography is presented. This is a two-stage holographic process; during the recording stage a hologram of the object of interest is obtained. The reference beam is composed of two beams that form a small angle between them and keep their polarization states at right angles to each other. In the reconstruction stage of the hologram, two images from the hologram are obtained along two different angles. As a result of the interference between these two images, a set of parallel fringes is formed at the image plane. The fringe contrast on the reconstruction is related to the angle of the polarization vector of the light at each position on the image plane. Measurements of the rotation of the polarization angle of a fraction of a degree were obtained. The main application of this technique is in the study of transient phenomena, where single-shot measurements are the only means of obtaining reliable data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and objective: Asthma is one of the most frequent chronic diseases affecting children and adolescents. Good compliance is indispensable for effective treatment since a suboptimal use of inhalation devices can result in decreased therapeutic efficacy and increased morbidity. The objective of this work was to evaluate the inhalation technique of paediatric patients visiting a specialized consultation clinic of a university hospital. Design: Observational prospective study during a 3-month period. Setting Specialized consultation clinic of a university hospital. Main outcome measures: This study involved 40 outpatient infants, children and adolescents visiting alone or with their parent(s). Patients' data (age, sex, weight, diagnostic, reason for consulting, previous consultations) and their medicines were compiled using an ad hoc form. Filmed sequences of the inhalation procedure used by each child were reviewed independently by members of an interdisciplinary team consisting in a physician, a pharmacist, a nurse and a physiotherapist. A score of 1 was assigned to each correct step in the procedure, and a score of 0 to an incorrect step. A perfect procedure implied 12 correct steps. Results: Thirty patients were treated with a metered-dose inhaler and an inhalation chamber (Babyhaler or AeroChamber Plus); ten other patients were treated with a dry powder inhaler (Diskus or Turbuhaler). The agreement between the members of the interdisciplinary team was considered satisfactory. Nine patients (22.5%) reached an average score lower than 7, 18 patients (45%) a score between 7 and 10 and 13 (32.5%) a score equal to or better than 10. No patient reached the maximum score of 12. Users of the metered-dose inhalers (average score = 9.2) showed a better technique than users of the dry powder inhalers (average score = 7.4). Disappointingly, the score was not improved during a second consultation or following regular consultations. Conclusions: Video recording is a simple method to evaluate the degree of mastery of an inhalation procedure in paediatric patients. The method allows a convenient and efficient identification of suboptimal procedure steps by the hospital staff, and opens the way to patient-specific teaching. In two-thirds of juvenile patients, their inhalation technique was suboptimal despite initial training. This study shows conclusively that the inhalation technique in paediatric patients must be monitored during each examination, and teaching measures taken to improve it when necessary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectifs: Evaluer la technique de reconstruction itérative VEO en tomodensitométrie (TDM) du thorax chez l'enfant. Matériels et méthodes: Etude prospective, basée sur 20 patients (7-18 ans), suivis pour mucoviscidose et adressés pour TDM de suivi. Dix patients (groupe A) ont eu une acquisition basse-dose habituelle (BD). Dix patients (groupe B) ont eu une acquisition très-basse-dose (TBD) et ultra-basse-dose (UBD). Les acquisitions BD étaient reconstruites par rétroprojection filtrée (RPF), les acquisitions TBD et UBD étaient reconstruites par RPF et VEO. L'évaluation de VEO était basée sur la réduction de dose et la qualité des images (mesures de bruit et scores de visualisation des structures pulmonaires). Résultats: Une réduction de dose d'environ 50% était obtenue dans le groupe B. La réduction du bruit en VEO par rapport aux RPF était de 55% en TBD et de 75% en UBD. En VEO, une amélioration des scores de visualisation des structures pulmonaires était obtenue en TBD et UBD. Cependant, en VEO-UBD, la visualisation des structures distales demeuraient parfois insuffisante et celle des structures proximales était altérée par une modification de texture de l'image. Conclusion: Malgré une altération possible de la texture de l'image en UBD, la technique de reconstruction VEO est performante en réduction de dose et amélioration des images.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current 2D black blood coronary vessel wall imaging suffers from a relatively limited coverage of the coronary artery tree. Hence, a 3D approach facilitating more extensive coverage would be desirable. The straightforward combination of a 3D-acquisition technique together with a dual inversion prepulse can decrease the effectiveness of the black blood preparation. To minimize artifacts from insufficiently suppressed blood signal of the nearby blood pools, and to reduce residual respiratory motion artifacts from the chest wall, a novel local inversion technique was implemented. The combination of a nonselective inversion prepulse with a 2D selective local inversion prepulse allowed for suppression of unwanted signal outside a user-defined region of interest. Among 10 subjects evaluated using a 3D-spiral readout, the local inversion pulse effectively suppressed signal from ventricular blood, myocardium, and chest wall tissue in all cases. The coronary vessel wall could be visualized within the entire imaging volume.