865 resultados para battery-powered


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radioiodinated murine monoclonal antibodies (Mabs) 81C6, Me 1-14, C12, D12, and E9, made against or reactive with human gliomas but not normal brain, and Mab UJ13A, a pan-neuroectodermal Mab reactive with normal human glial and neural cells, were evaluated in paired label studies in the D-54 MG subcutaneous human glioma xenograft model system in nude mice. Following intravenous injection in the tail vein of mice bearing 200-400 mm3 tumors, specific localization of Mabs to tumor over time (6 h-9 days) was evaluated by tissue counting; each Mab demonstrated a unique localization profile. The comparison of localization indices (LI), determined as a ratio of tissue level of Mab to control immunoglobulin with simultaneous correction for blood levels of each, showed Mabs 81C6 and Me 1-14 to steadily accumulate in glioma xenografts, maintaining LI from 5-20 at 7-9 days after Mab injection. Mab UJ13A peaked at day 1, maintaining this level through day 2, and declining thereafter. Mabs D12 and C12 peaked at days 3 and 4, respectively, and E9 maintained an LI of greater than 3 from days 3-9. Percent injected dose localized/g of tumor varied from a peak high of 16% (81C6) to a low of 5% (Me 1-14 and UJ13A). Immunoperoxidase histochemistry, performed with each Mab on a battery of primary human brain neoplasms, revealed that Mabs 81C6 and E9, which demonstrated the highest levels of percent injected dose localized/g of tumor over time, reacted with antigens expressed in the extracellular matrix. This finding suggests that extracellular matrix localization of antigen represents a biologically significant factor affecting localization and/or binding in the xenograft model used. The demonstration of significant localization, varied kinetics and patterns of localization of this localizing Mab panel warrants their continued investigation as potential imaging and therapeutic agents for human trials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Extracorporeal life support systems (ECLS) have become common in cardiothoracic surgery, but are still "Terra Incognita" in other medical fields due to the fact that perfusion units are normally bound to cardiothoracic centres. The Lifebridge B2T is an ECLS that is meant to be used as an easy and fast-track extracorporeal cardiac support to provide short-term perfusion for the transport of a patient to a specialized centre. With the Lifebridge B2T it is now possible to provide extracorporeal bypass for patients in hospitals without a perfusion unit. The Lifebridge B2T was tested on three calves to analyze the handling, performance and security of this system. The Lifebridge B2T safely can be used clinically and can provide full extracorporeal support for patients in cardiac or pulmonary failure. Flows up to 3.9 +/- 0.2l/min were reached, with an inflow pressure of -103 +/- 13mmHg, using a 21Fr. BioMedicus (Medtronic, Minneapolis, MN, USA) venous cannula. The "Plug and Play" philosophy, with semi-automatic priming, integrated check-list, a long battery time of over two hours and instinctively designed user interface, makes this device very interesting for units with high-risk interventions, such as catheterisation labs. If a system is necessary in an emergency unit, the Lifebridge can provide a high security level, even in centres not acquainted with cardiopulmonary bypass.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This User’s Guide serves as a reference for field personnel using the sign inventory data collection software tool. This tool was developed to simplify and standardize the collection and updating of sign inventory information. The software and collection methodology was developed by the Iowa DOT Sign Management Task Force and the Center for Transportation Research and Education at Iowa State University. Required Equipment -The data collection process requires both a portable computer and a global positioning system (GPS) device (connected via USB cable). Since computer battery performance varies, a DC power converter is recommended. A check-in/out process has also been established which allows updates to sign information from the central database.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Neuropsychological deficits (NPD) are common in patients with aneurysmal subarachnoid haemorrhage (aSAH). NPD are one of the major limiting factors for patients with an otherwise acceptable prognosis for sustained quality of life. There are only a few studies reporting outcome after aSAH, which used a standardized neuropsychological test battery as a primary or secondary outcome measure. Aim of this study was to determine the current practice of reporting NPD following aSAH in clinical studies. METHODS: A MEDLINE analysis was performed using the search term "subarachnoid haemorrhage outcome". The latest 1,000 articles were screened. We recorded study design, number of patients, and the presence of neuropsychological outcome report. Additionally, the time of testing after aSAH, the neuropsychological tests administered, as well as the percentage of patients with NPD were analyzed. RESULTS: A total of 324 publications between 2009 and 2012 were selected for further review. Of those, 21 studies (6.5%) reported neuropsychological outcome, in 2,001 of 346,666 patients (0.6%). The assessment of NPD differed broadly using both subjective and objective cognitive evaluation, and a large variety of tests were used. CONCLUSION: Neuropsychological outcome is underreported, and there is great variety in assessment in currently published clinical articles on aSAH. Prospective randomized trials treating aSAH may benefit from implementing more comprehensive and standardized neuropsychological outcome measures. This approach might identify otherwise unnoticed treatment effects in future interventional studies of aSAH patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to assess the effects of an extreme mountain ultramarathon (MUM, 330 km, 24,000 D+) on lung function. Twenty-nine experienced male ultramarathon runners performed longitudinally [before (pre), during (mid), and immediately after (post) a MUM] a battery of pulmonary function tests. The tests included measurements of forced vital capacity, forced expiratory volume in 1 s, peak flow, inspiratory capacity, and maximum voluntary ventilation in 12 s (MVV12). A significant reduction in the running speed was observed (-43.0% between pre-mid and mid-post; P < 0.001). Expiratory function declined significantly at mid (P < 0.05) and at post (P < 0.05). A similar trend was observed for inspiratory function (P < 0.05). MVV12 declined at mid (P < 0.05) and further decreased at post (P < 0.05). Furthermore, there are significant negative correlations between performance time and MVV12 pre-race (R = -0.54, P = 0.02) as well as changes in MVV12 between pre- and post-race (R = -0.53, P = 0.009). It is concluded that during an extreme MUM, a continuous decline in pulmonary function was observed, likely attributable to the high levels of ventilation required during this MUM in a harsh mountainous environment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work is divided into three volumes: Volume I: Strain-Based Damage Detection; Volume II: Acceleration-Based Damage Detection; Volume III: Wireless Bridge Monitoring Hardware. Volume I: In this work, a previously-developed structural health monitoring (SHM) system was advanced toward a ready-for-implementation system. Improvements were made with respect to automated data reduction/analysis, data acquisition hardware, sensor types, and communication network architecture. The statistical damage-detection tool, control-chart-based damage-detection methodologies, were further investigated and advanced. For the validation of the damage-detection approaches, strain data were obtained from a sacrificial specimen attached to the previously-utilized US 30 Bridge over the South Skunk River (in Ames, Iowa), which had simulated damage,. To provide for an enhanced ability to detect changes in the behavior of the structural system, various control chart rules were evaluated. False indications and true indications were studied to compare the damage detection ability in regard to each methodology and each control chart rule. An autonomous software program called Bridge Engineering Center Assessment Software (BECAS) was developed to control all aspects of the damage detection processes. BECAS requires no user intervention after initial configuration and training. Volume II: In this work, a previously developed structural health monitoring (SHM) system was advanced toward a ready-for-implementation system. Improvements were made with respect to automated data reduction/analysis, data acquisition hardware, sensor types, and communication network architecture. The objective of this part of the project was to validate/integrate a vibration-based damage-detection algorithm with the strain-based methodology formulated by the Iowa State University Bridge Engineering Center. This report volume (Volume II) presents the use of vibration-based damage-detection approaches as local methods to quantify damage at critical areas in structures. Acceleration data were collected and analyzed to evaluate the relationships between sensors and with changes in environmental conditions. A sacrificial specimen was investigated to verify the damage-detection capabilities and this volume presents a transmissibility concept and damage-detection algorithm that show potential to sense local changes in the dynamic stiffness between points across a joint of a real structure. The validation and integration of the vibration-based and strain-based damage-detection methodologies will add significant value to Iowa’s current and future bridge maintenance, planning, and management Volume III: In this work, a previously developed structural health monitoring (SHM) system was advanced toward a ready-for-implementation system. Improvements were made with respect to automated data reduction/analysis, data acquisition hardware, sensor types, and communication network architecture. This report volume (Volume III) summarizes the energy harvesting techniques and prototype development for a bridge monitoring system that uses wireless sensors. The wireless sensor nodes are used to collect strain measurements at critical locations on a bridge. The bridge monitoring hardware system consists of a base station and multiple self-powered wireless sensor nodes. The base station is responsible for the synchronization of data sampling on all nodes and data aggregation. Each wireless sensor node include a sensing element, a processing and wireless communication module, and an energy harvesting module. The hardware prototype for a wireless bridge monitoring system was developed and tested on the US 30 Bridge over the South Skunk River in Ames, Iowa. The functions and performance of the developed system, including strain data, energy harvesting capacity, and wireless transmission quality, were studied and are covered in this volume.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Volumes of data used in science and industry are growing rapidly. When researchers face the challenge of analyzing them, their format is often the first obstacle. Lack of standardized ways of exploring different data layouts requires an effort each time to solve the problem from scratch. Possibility to access data in a rich, uniform manner, e.g. using Structured Query Language (SQL) would offer expressiveness and user-friendliness. Comma-separated values (CSV) are one of the most common data storage formats. Despite its simplicity, with growing file size handling it becomes non-trivial. Importing CSVs into existing databases is time-consuming and troublesome, or even impossible if its horizontal dimension reaches thousands of columns. Most databases are optimized for handling large number of rows rather than columns, therefore, performance for datasets with non-typical layouts is often unacceptable. Other challenges include schema creation, updates and repeated data imports. To address the above-mentioned problems, I present a system for accessing very large CSV-based datasets by means of SQL. It's characterized by: "no copy" approach - data stay mostly in the CSV files; "zero configuration" - no need to specify database schema; written in C++, with boost [1], SQLite [2] and Qt [3], doesn't require installation and has very small size; query rewriting, dynamic creation of indices for appropriate columns and static data retrieval directly from CSV files ensure efficient plan execution; effortless support for millions of columns; due to per-value typing, using mixed text/numbers data is easy; very simple network protocol provides efficient interface for MATLAB and reduces implementation time for other languages. The software is available as freeware along with educational videos on its website [4]. It doesn't need any prerequisites to run, as all of the libraries are included in the distribution package. I test it against existing database solutions using a battery of benchmarks and discuss the results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to assess the association between frailty and risk for heart failure (HF) in older adults. BACKGROUND: Frailty is common in the elderly and is associated with adverse health outcomes. Impact of frailty on HF risk is not known. METHODS: We assessed the association between frailty, using the Health ABC Short Physical Performance Battery (HABC Battery) and the Gill index, and incident HF in 2825 participants aged 70 to 79 years. RESULTS: Mean age of participants was 74 ± 3 years; 48% were men and 59% were white. During a median follow up of 11.4 (7.1-11.7) years, 466 participants developed HF. Compared to non-frail participants, moderate (HR 1.36, 95% CI 1.08-1.71) and severe frailty (HR 1.88, 95% CI 1.02-3.47) by Gill index was associated with a higher risk for HF. HABC Battery score was linearly associated with HF risk after adjusting for the Health ABC HF Model (HR 1.24, 95% CI 1.13-1.36 per SD decrease in score) and remained significant when controlled for death as a competing risk (HR 1.30; 95% CI 1.00-1.55). Results were comparable across age, sex, and race, and in sub-groups based on diabetes mellitus or cardiovascular disease at baseline. Addition of HABC Battery scores to the Health ABC HF Risk Model improved discrimination (change in C-index, 0.014; 95% CI 0.018-0.010) and appropriately reclassified 13.4% (net-reclassification-improvement 0.073, 95% CI 0.021-0.125; P = .006) of participants (8.3% who developed HF and 5.1% who did not). CONCLUSIONS: Frailty is independently associated with risk of HF in older adults.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Yearly administration of the influenza vaccine is the main strategy to prevent influenza in immunocompromised patients. Here, we reviewed the recent literature regarding the clinical significance of the influenza virus infection, as well as the immunogenicity and safety of the influenza vaccine in HIV‑infected individuals, solid-organ and stem-cell transplant recipients and patients receiving biological agents. Epidemiological data produced during the 2009 influenza pandemic have confirmed that immunocompromised patients remain at high risk of influenza-associated complications, namely viral and bacterial pneumonia, hospitalization and even death. The immunogenicity of the influenza vaccine is overall reduced in immunocompromised patients, although a significant clinical protection from influenza is expected to be obtained with vaccination. Influenza vaccination is safe in immunocompromised patients. The efficacy of novel strategies to improve the immunogenicity to the vaccine, such as the use of adjuvanted vaccines, boosting doses and intradermal vaccination, needs to be validated in appropriately powered clinical trials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Two or three DNA primes have been used in previous smaller clinical trials, but the number required for optimal priming of viral vectors has never been assessed in adequately powered clinical trials. The EV03/ANRS Vac20 phase I/II trial investigated this issue using the DNA prime/poxvirus NYVAC boost combination, both expressing a common HIV-1 clade C immunogen consisting of Env and Gag-Pol-Nef polypeptide. Methods: 147 healthy volunteers were randomly allocated through 8 European centres to either 3xDNA plus 1xNYVAC (weeks 0, 4, 8 plus 24; n¼74) or to 2xDNA plus 2xNYVAC (weeks 0, 4 plus 20, 24; n¼73), stratified by geographical region and sex. T cell responses were quantified using the interferon g Elispot assay and 8 peptide pools; samples from weeks 0, 26 and 28 (time points for primary immunogenicity endpoint), 48 and 72 were considered for this analysis. Results: 140 of 147 participants were evaluable at weeks 26 and/ or 28. 64/70 (91%) in the 3xDNA arm compared to 56/70 (80%) in the 2xDNA arm developed a T cell response (P¼0.053). 26 (37%) participants of the 3xDNA arm developed a broader T cell response (Env plus at least to one of the Gag, Pol, Nef peptide pools) versus 15 (22%) in the 2xDNA arm (P¼0.047). At week 26, the overall magnitude of responses was also higher in the 3xDNA than in the 2xDNA arm (similar at week 28), with a median of 545 versus 328 SFUs/106 cells at week 26 (P<0.001). Preliminary overall evaluation showed that participants still developed T-cell response at weeks 48 (78%, n¼67) and 72 (70%, n¼66). Conclusion: This large clinical trial demonstrates that optimal priming of poxvirus-based vaccine regimens requires 3 DNA regimens and further confirms that the DNA/NYVAC prime boost vaccine combination is highly immunogenic and induced durable T-cell responses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Macrophage migration inhibitory factor (MIF), a proinflammatory cytokine, is considered an attractive therapeutic target in multiple inflammatory and autoimmune disorders. In addition to its known biologic activities, MIF can also function as a tautomerase. Several small molecules have been reported to be effective inhibitors of MIF tautomerase activity in vitro. Herein we employed a robust activity-based assay to identify different classes of novel inhibitors of the catalytic and biological activities of MIF. Several novel chemical classes of inhibitors of the catalytic activity of MIF with IC(50) values in the range of 0.2-15.5 microm were identified and validated. The interaction site and mechanism of action of these inhibitors were defined using structure-activity studies and a battery of biochemical and biophysical methods. MIF inhibitors emerging from these studies could be divided into three categories based on their mechanism of action: 1) molecules that covalently modify the catalytic site at the N-terminal proline residue, Pro(1); 2) a novel class of catalytic site inhibitors; and finally 3) molecules that disrupt the trimeric structure of MIF. Importantly, all inhibitors demonstrated total inhibition of MIF-mediated glucocorticoid overriding and AKT phosphorylation, whereas ebselen, a trimer-disrupting inhibitor, additionally acted as a potent hyperagonist in MIF-mediated chemotactic migration. The identification of biologically active compounds with known toxicity, pharmacokinetic properties, and biological activities in vivo should accelerate the development of clinically relevant MIF inhibitors. Furthermore, the diversity of chemical structures and mechanisms of action of our inhibitors makes them ideal mechanistic probes for elucidating the structure-function relationships of MIF and to further determine the role of the oligomerization state and catalytic activity of MIF in regulating the function(s) of MIF in health and disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This report provides details of IADOT's experience removing and crushing asphaltic concrete and portland cement concrete for recycling. The recycled material was used on interstate highways for the subbase and shoulders. The major problem IADOT encountered on this project was the removal of reinforcing steel from the broken concrete. The contractor used hydraulic powered shears to clip off all protruding steel during the removal and loading of the concrete on the grade. This project took place in 1977.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Membrane-active antimicrobial peptides, such as polymyxin B (PxB), are currently in the spotlight as potential candidates toovercome bacterial resistance. We have designed synthetic analogs ofPxB in order to determine the structural requirements for membraneaction. Since the mechanism of action of PxB involves interaction withboth the outer membrane and the cytoplasmic membrane of Gramnegative bacteria, we have used an approach based on mimicking theouter layers of these membranes using monolayers, Langmuir-Blodgettfilms and unilamelar vesicles, and applying a battery of biophysicalmethods in order to dissect the different events of membraneinteraction. Collectively, results indicate that the PxB analogues act inthe bacterial membrane by the same mechanism than PxB, and that cationic amphipathicity determines peptide activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Protocols for enhanced recovery provide comprehensive and evidence-based guidelines for best perioperative care. Protocol implementation may reduce complication rates and enhance functional recovery and, as a result of this, also reduce length-of-stay in hospital. There is no comprehensive framework available for pancreaticoduodenectomy. METHODS: An international working group constructed within the Enhanced Recovery After Surgery (ERAS(®)) Society constructed a comprehensive and evidence-based framework for best perioperative care for pancreaticoduodenectomy patients. Data were retrieved from standard databases and personal archives. Evidence and recommendations were classified according to the GRADE system and reached through consensus in the group. The quality of evidence was rated "high", "moderate", "low" or "very low". Recommendations were graded as "strong" or "weak". RESULTS: Comprehensive guidelines are presented. Available evidence is summarised and recommendations given for 27 care items. The quality of evidence varies substantially and further research is needed for many issues to improve the strength of evidence and grade of recommendations. CONCLUSIONS: The present evidence-based guidelines provide the necessary platform upon which to base a unified protocol for perioperative care for pancreaticoduodenectomy. A unified protocol allows for comparison between centres and across national borders. It facilitates multi-institutional prospective cohort registries and adequately powered randomised trials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chronic atrial fibrillation affects millions of people worldwide. Its surgical treatment often fails to restore the transport function of the atrium. This study first introduces the concept of an atrial assist device (AAD) to restore the pump function of the atrium. The AAD is developed to be totally implantable in the human body with a transcutaneous energy transfer system to recharge the implanted battery. The ADD consists of a motorless pump based on artificial muscle technology, positioned on the external surface of the atrium to compress it and restore its muscular activity. A bench model reproduces the function of a fibrillating atrium to assess the circulatory support that this pump can provide. Atripump (Nanopowers SA, Switzerland) is a dome-shaped silicone-coated nitinol actuator 5 mm high, sutured on the external surface of the atrium. A pacemaker-like control unit drives the actuator that compresses the atrium, providing the mechanical support to the blood circulation. Electrical characteristics: the system is composed of one actuator that needs a minimal tension of 15 V and has a maximum current of 1.5 A with a 50% duty cycle. The implantable rechargeable battery is made of a cell having the following specifications: nominal tension of a cell: 4.1 V, tension after 90% of discharge: 3.5 V, nominal capacity of a cell: 163 mA h. The bench model consists of an open circuit made of latex bladder 60 mm in diameter filled with water. The bladder is connected to a vertically positioned tube that is filled to different levels, reproducing changes in cardiac preload. The Atripump is placed on the outer surface of the bladder. Pressure, volume and temperature changes were recorded. The contraction rate was 1 Hz with a power supply of 12 V, 400 mA for 200 ms. Preload ranged from 15 to 21 cm H(2)O. Maximal silicone membrane temperature was 55 degrees C and maximal temperature of the liquid environment was 35 degrees C. The pump produced a maximal work of 16 x 10(-3) J. Maximal volume pumped was 492 ml min(-1). This artificial muscle pump is compact, follows the Starling law and reproduces the hemodynamic performances of a normal atrium. It could represent a new tool to restore the atrial kick in persistent atrial fibrillation.