911 resultados para anaerobic conditions in sewer systems
Resumo:
This experiment was developed in order to evaluation the efficiency of pheromone to control the pink bollworm and the total time of its release in cotton field. The experiment was installed in field conditions, in Chapadao do Sul/SP/Brazil, from January to April, 1998. The treatments consisted of 2 areas, being one of 30ha, where it was applied the pheromone and another of 10ha that was chosen as control area and did not receive pheromone. In the treated area, the laboratory synthesized sex pheromone (PB-Rope) was used thought of dispensers that allowed the slow and gradual release of the active substance. A total of 250 dispenser per hectare were evenly hand distributed in the area. The dispensers were wrapped around the plants. Both areas (treated area and untreated area) were monitored by delta trap. For evaluation of the boll damage, the treatment area was divided into 4 sub-areas. Twenty five green bolls were collected at random from each sub-area at 48 and 65 days after pheromone treatment. Bolls were cracked open by hand, and number of the bolls with symptoms of pink bollworm attacks was recorded. For evaluation of the productivity four areas were demarcated in each treatment, where all fibers and seeds harvested were weighted. Release rate of pheromone from dispenser was evaluated through of the weigh of the dispensers. Were marked and weighed in analytic scale, 20 dispensers contend the pheromone, being placed 10 dispensers under the cotton plants in treated area and other 10 dispensers in an open area. To every 15 days the dispensers were retired and weighed in analytic scale and soon after put back in the field in the same places. The results showed that only one application of mating disrupt pheromone, used in a dosage of 250 dispenser/ha, reached 80% of control for pink bollworm. the release period of pheromone from dispenser, after the application, was 120 days.
Resumo:
The effect of stocking prawns Macrobrachium rosenbergii at increasing densities in ponds with Nile tilapia Oreochromis niloticus reared at low density was evaluated. Twelve 0.01-ha earthen ponds were stocked with 1 tilapia/m2 and 0, 2, 4, or 6 post-larvae prawn/m2. Three replicates were randomly assigned to each prawn density. Postlarval prawns were stocked a week prior to tilapia juveniles and both were harvested 175 d after the beginning of the experiment. Tilapia final average weight, survival, production, and food conversion rates did not differ significantly among treatments (P > 0.05); the averages were 531 g. 67%, 3,673 kg/ha, and 1.91, respectively. Prawn survival rates did not differ for the three stocking densities (mean 90%). However, final weight and production were significantly different (P < 0.05) as follows: 34.0, 23.0, and 14.7 g and 639, 909, and 818 kg/ha, respectively for 2, 4, and 6 prawns/m2 densities. Stocking densities up to 6 prawn/m2 did not affect tilapia production and required neither additional feeding nor significant changes in management. The polyculture system allowed an increase in total production with the same amount of supplied feed, thus improving the system sustainability.
Resumo:
The three-body recombination coefficient of an ultracold atomic system, together with the corresponding two-body scattering length a, allow us to predict the energy E 3 of the shallow trimer bound state, using a universal scaling function. The production of dimers in trapped Bose-Einstein condensates, from three-body recombination processes, in the regime of short magnetic pulses near a Feshbach resonance, is also studied in line with the experimental observation.
Resumo:
Reliability of power supply is related, among other factors, to the control and protection devices allocation in feeders of distribution systems. In this way, optimized allocation of sectionalizing switches and protection devices in strategic points of distribution circuits, improves the quality of power supply and the system reliability indices. In this work, it is presented a mixed integer non-linear programming (MINLP) model, with real and binary variables, for the sectionalizing switches and protection devices allocation problem, in strategic sectors, aimed at improving reliability indices, increasing the utilities billing and fulfilling exigencies of regulatory agencies for the power supply. Optimized allocation of protection devices and switches for restoration, allows that those faulted sectors of the system can be isolated and repaired, re-managing loads of the analyzed feeder into the set of neighbor feeders. Proposed solution technique is a Genetic Algorithm (GA) developed exploiting the physical characteristics of the problem. Results obtained through simulations for a real-life circuit, are presented. © 2004 IEEE.
Resumo:
In this work the problem of defects location in power systems is formulated through a binary linear programming (BLP) model based on alarms historical database of control and protection devices from the system control center, sets theory of minimal coverage (AI) and protection philosophy adopted by the electric utility. In this model, circuit breaker operations are compared to their expected states in a strictly mathematical manner. For solving this BLP problem, which presents a great number of decision variables, a dedicated Genetic Algorithm (GA), is proposed. Control parameters of the GA, such as crossing over and mutation rates, population size, iterations number and population diversification, are calibrated in order to obtain efficiency and robustness. Results for a test system found in literature, are presented and discussed. © 2004 IEEE.
Resumo:
In some applications like fault analysis, fault location, power quality studies, safety analysis, loss analysis, etc., knowing the neutral wire and ground currents and voltages could be of particular interest. In order to investigate effects of neutrals and system grounding on the operation of the distribution feeders with faults, in this research a hybrid short circuit algorithm is generalized. In this novel use of the technique, the neutral wire and assumed ground conductor are explicitly represented. Results obtained from several case studies using IEEE 34-node test network are presented and discussed.
Resumo:
The sugar cane crop is one of the main products in Brazil and according to several authors can generate, besides the industrialized stalks, an amount of crop residues from the order of 15 to 30 % in weight of the aerial part of the plants, depending on the field conditions. The sugar cane area in Brazil is around 5.5×106 hectares, with an amount of 400.106 tons of stalks, with stalks yield of 72 tons.ha-1. This study took place in a sugar cane plot (Latitude 22°46'S, Longitude 47°23'W and 600m of altitude) with 3% of slope, located in São Paulo State. The sugar cane variety was SP 80-1816, in its forth cut, 11 months old and with a planted row spacing of 1.40 m. By other side, several sugar mills are bringing the crop residue to their patio to produce energy with the bagasse. One choice is to bring the crop residue at the same moment with the stalks, avoiding the next operation of baling it. The objective of this study was to analyze some operational parameters of two different sugar cane harvesters under the same field conditions, which was divided in four treatments: T1 = CAMECO CHT2500B operating normally; T2 = CAMECO CHT2500B operating without the cleaning system; T3 = CASE 7700 operating normally; T4 = CASE 7700 operating without the cleaning system. The results obtained were: Table presented CEB = Gross effective capacity; CEL = Net effective capacity. The conclusion is that under normal operation the CASE harvester worked better then CAMECO in the parameters CEL stalks and Manipulation efficiency. And without the cleaning system operating CASE also worked better in the parameters of CEB raw material, CEB stalks, CEL raw material and CEL stalks.
Resumo:
Given that tobacco smoking habit is a risk factor for periodontal diseases, the aim of this study was to compare clinical periodontal aspects between smokers and non-smokers. The clinical status were assessed in 55 patients, 29 smokers and 26 non-smokers, aged 30 to 50 years, with mean age of 40. The clinical parameters used were: probing depth (PD), plaque index (PI), gingival index (GI), clinical attachment level (CAL), gingival recession (GR) and gingival bleeding index (GBI) for arches (upper and lower ) and teeth (anterior and posterior). Tooth loss was also evaluated in both groups. Multiple regression analysis showed: tendency of greater probing depth and clinical attachment level means for smokers; greater amount of plaque in smokers in all regions; greater gingival index means for non-smokers with clinical significance (p<0.05) in all regions. Although, without statistical significance, the analysis showed greater gingival bleeding index means almost always for nonsmokers; similar gingival recession means in both groups and tendency of upper tooth loss in smokers and lower tooth loss in non-smokers. The findings of this study showed that clinical periodontal parameters may be different in smokers when compared to non-smokers and that masking of some periodontal signs can be a result of nicotine's vasoconstrictor effect.
Resumo:
Mesoclemmys vanderhaegei is a Neotropical chelid lacking basic natural history studies. Based on a film made in December 2004, we describe the courtship behavior in this species. Field observations were conducted at Chapada dos Guimarães, Mato Grosso State, southwestern Brazil, in an oligotrophic stream amidst the savannah like Cerrado formation. We provide a schematic drawing of the behavioral sequences during courtship, as well as a flow diagram describing sequential responses of the female to the male behavioral patterns. Mesoclemmys vanderhaegei courtship behavior is similar to that described for other freshwater chelonians.
Resumo:
This work evaluated kinetic and adsorption physicochemical models for the biosorption process of lanthanum, neodymium, europium, and gadolinium by Sargassum sp. in batch systems. The results showed: (a) the pseudo-second order kinetic model was the best approximation for the experimental data with the metal adsorption initial velocity parameter in 0.042-0.055 mmol.g -1.min-1 (La < Nd < Gd < Eu); (b) the Langmuir adsorption model presented adequate correlation with maximum metal uptake at 0.60-0.70 mmol g-1 (Eu < La < Gd < Nd) and the metal-biomass affinity parameter showed distinct values (Gd < Nd < Eu < La: 183.1, 192.5, 678.3, and 837.3 L g-1, respectively); and (c) preliminarily, the kinetics and adsorption evaluation did not reveal a well-defined metal selectivity behavior for the RE biosorption in Sargassum sp., but they indicate a possible partition among RE studied. © (2009) Trans Tech Publications.
Resumo:
Nowadays, one of the most important concerns for many companies is to maintain the operation of their systems without sudden equipment break down. Because of this, new techniques for fault detection and location in mechanical systems subject to dynamic loads have been developed. This paper studies of the influence of the decay rate in the design of state observers using LMI for fault detection in mechanical systems. This influence is analyzed by the performance index proposed by Huh and Stein for the condition of a state observer. An example is presented to illustrate the methodology discussed.
Resumo:
Aim. The purpose of this study was to compare the anaerobic threshold speed (AT) obtained from fixed lactate blood concentrations (AT 4 mM and AT 3.5 mM), lactate minimum speed (LM) and critical speed (CS), determined from different distances in fifteen Brazilian national level swimmers (10 boys = 14.8 ± 0.6 years old and 5 girls = 14.6 ±0.8 year-old). Methods. The tests to determine the AT 4 mM, AT 3.5 mM, LM and CS were performed in a 25 m swimming pool and consisted of 7 or 8 evaluations separated by 24-48 h intervals. Data were submitted to analysis of variance (ANOVA) for repeated measures, followed by the post hoc Scheffé test and Pearson correlation coefficients. Significance was set at P<0.01. Results. There were no significant differences among the values for AT 4 mM and CS1 (1.34 ± 0.05 vs. 1.33 ± 0.05 m.s -1, respectively). However, AT 4 mM and CS1 were significantly higher than AT 3.5 mM (1.28 ± 0.04 m.s -1), LM (1.27 ± 0.05 m.s -1), CS2 (1.26 ± 0.06 m.s -1), CS3 (1.27 ± 0.06 m.s -1) and CS4 (1.25 ± 0.07 m.s -1). There were no significant differences among the values for AT 3.5 mM, LM, CS2, CS3 and CS4. Conclusion. The results obtained in this study suggest that the anaerobic threshold determined by a fixed lactate concentration of 3.5 mM, as well as the LM and the CS methods determined by different distances, seem to be the most appropriate indexes for the evaluation of aerobic capacity in adolescent swimmers.
Resumo:
This article aims to present proposals for improvement of key standards and resolutions concerned about the methodology for calculating the indicator of total harmonic voltage distortion, and should contribute to the process of examining the compatibility of potentially disturbing loads in electric power quality in distribution systems. These proposals were drawn from the analysis of results from measurement campaigns conducted in a case study including analysis of the connection of a new induction furnace in a foundry served by a distributor of São Paulo state. A general historical situating the quality of electric energy in the electricity sector is presented, and methodological guidelines and procedures used in experimental trials are shown. The analysis and discussion of results are prepared to answer the main questions that arise during the implementation of standards, resolutions and procedures. © 2011 IEEE.
Resumo:
Distributed Generation, microgrid technologies, two-way communication systems, and demand response programs are issues that are being studied in recent years within the concept of smart grids. At some level of enough penetration, the Distributed Generators (DGs) can provide benefits for sub-transmission and transmission systems through the so-called ancillary services. This work is focused on the ancillary service of reactive power support provided by DGs, specifically Wind Turbine Generators (WTGs), with high level of impact on transmission systems. The main objective of this work is to propose an optimization methodology to price this service by determining the costs in which a DG incurs when it loses sales opportunity of active power, i.e, by determining the Loss of Opportunity Costs (LOC). LOC occur when more reactive power is required than available, and the active power generation has to be reduced in order to increase the reactive power capacity. In the optimization process, three objectives are considered: active power generation costs of DGs, voltage stability margin of the system, and losses in the lines of the network. Uncertainties of WTGs are reduced solving multi-objective optimal power flows in multiple probabilistic scenarios constructed by Monte Carlo simulations, and modeling the time series associated with the active power generation of each WTG via Fuzzy Logic and Markov Chains. The proposed methodology was tested using the IEEE 14 bus test system with two WTGs installed. © 2011 IEEE.