978 resultados para a pump


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil - Área de especialização de Hidráulica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 30-year-old black woman presented with heartburn and odynophagia. She had a 2-year history of Behçet’s disease and systemic lupus erythematosus and had been treated with colchicine, hydroxychloroquine, and sucralfate. Odynophagia was not related to the presence of oral ulcers as they were painless and when they were in remission the patient would still intermittently complain of substernal pain. The patient underwent upper digestive endoscopy that revealed only small mucosal irregularities in the upper third of the esophagus. Biopsies of these segments showed marked acanthosis and papillomatosis of the squamous epithelium as well as intense lymphoplasmacytic infiltrate with an increased number of intraepithelial lymphocytes (IEL). There were neither granulocytes nor signs of viral infection. The endoscopic findings were then attributed to regenerative changes of the epithelium and the patient was started on a proton pump inhibitor (PPI), assuming gastroesophageal reflux disease (GERD). During the following years there were flare-ups of rheumatologic disease activity due to the patient’s lack of adherence to therapy. However, there was no correlation of the patient’s maintained (although scarce) complaints of transitory dysphagia and substernal pain.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract The emergence of multi and extensively drug resistant tuberculosis (MDRTB and XDRTB) has increased the concern of public health authorities around the world. The World Health Organization has defined MDRTB as tuberculosis (TB) caused by organisms resistant to at least isoniazid and rifampicin, the main first-line drugs used in TB therapy, whereas XDRTB refers to TB resistant not only to isoniazid and rifampicin, but also to a fluoroquinolone and to at least one of the three injectable second-line drugs, kanamycin, amikacin and capreomycin. Resistance in Mycobacterium tuberculosis is mainly due to the occurrence of spontaneous mutations and followed by selection of mutants by subsequent treatment. However, some resistant clinical isolates do not present mutations in any genes associated with resistance to a given antibiotic, which suggests that other mechanism(s) are involved in the development of drug resistance, namely the presence of efflux pump systems that extrude the drug to the exterior of the cell, preventing access to its target. Increased efflux activity can occur in response to prolonged exposure to subinhibitory concentrations of anti-TB drugs, a situation that may result from inadequate TB therapy. The inhibition of efflux activity with a non-antibiotic inhibitor may restore activity of an antibiotic subject to efflux and thus provide a way to enhance the activity of current anti-TB drugs. The work described in this thesis foccus on the study of efflux mechanisms in the development of multidrug resistance in M. tuberculosis and how phenotypic resistance, mediated by efflux pumps, correlates with genetic resistance. In order to accomplish this goal, several experimental protocols were developed using biological models such as Escherichia coli, the fast growing mycobacteria Mycobacterium smegmatis, and Mycobacterium avium, before their application to M. tuberculosis. This approach allowed the study of the mechanisms that result in the physiological adaptation of E. coli to subinhibitory concentrations of tetracycline (Chapter II), the development of a fluorometric method that allows the detection and quantification of efflux of ethidium bromide (Chapter III), the characterization of the ethidium bromide transport in M. smegmatis (Chapter IV) and the contribution of efflux activity to macrolide resistance in Mycobacterium avium complex (Chapter V). Finally, the methods developed allowed the study of the role of efflux pumps in M. tuberculosis strains induced to isoniazid resistance (Chapter VI). By this manner, in Chapter II it was possible to observe that the physiological adaptation of E. coli to tetracycline results from an interplay between events at the genetic level and protein folding that decrease permeability of the cell envelope and increase efflux pump activity. Furthermore, Chapter III describes the development of a semi-automated fluorometric method that allowed the correlation of this efflux activity with the transport kinetics of ethidium bromide (a known efflux pump substrate) in E. coli and the identification of efflux inhibitors. Concerning M. smegmatis, we have compared the wild-type M. smegmatis mc2155 with knockout mutants for LfrA and MspA for their ability to transport ethidium bromide. The results presented in Chapter IV showed that MspA, the major porin in M. smegmatis, plays an important role in the entrance of ethidium bromide and antibiotics into the cell and that efflux via the LfrA pump is involved in low-level resistance to these compounds in M. smegmatis. Chapter V describes the study of the contribution of efflux pumps to macrolide resistance in clinical M. avium complex isolates. It was demonstrated that resistance to clarithromycin was significantly reduced in the presence of efflux inhibitors such as thioridazine, chlorpromazine and verapamil. These same inhibitors decreased efflux of ethidium bromide and increased the retention of [14C]-erythromycin in these isolates. Finaly, the methods developed with the experimental models mentioned above allowed the study of the role of efflux pumps on M. tuberculosis strains induced to isoniazid resistance. This is described in Chapter VI of this Thesis, where it is demonstrated that induced resistance to isoniazid does not involve mutations in any of the genes known to be associated with isoniazid resistance, but an efflux system that is sensitive to efflux inhibitors. These inhibitors decreased the efflux of ethidium bromide and also reduced the minimum inhibitory concentration of isoniazid in these strains. Moreover, expression analysis showed overexpression of genes that code for efflux pumps in the induced strains relatively to the non-induced parental strains. In conclusion, the work described in this thesis demonstrates that efflux pumps play an important role in the development of drug resistance, namely in mycobacteria. A strategy to overcome efflux-mediated resistance may consist on the use of compounds that inhibit efflux activity, restoring the activity of antimicrobials that are efflux pump substrates, a useful approach particularly in TB where the most effective treatment regimens are becoming uneffective due to the increase of MDRTB/XDRTB.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thesis presented in partial fulfillment of the requirements for the degree of Doctor of Philosophy in the subject of Electrical and Computer Engineering by the Universidade Nova de Lisboa,Faculdade de Ciências e Tecnologia

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os aproveitamentos geotérmicos têm vindo a aumentar significativamente em todo o mundo, sendo os Estados Unidos da América, o maior produtor desta energia proveniente do interior da Terra, com cerca de 3.187 MW de capacidade instalada. Portugal tem capacidade instalada total de 29 MW, no entanto no que se refere ao aproveitamento de “alta entalpia”, isto é, o aproveitamento geotérmico para produção elétrica, apenas se encontra no arquipélago dos Açores, na ilha de S. Miguel, onde estão instaladas e em funcionamento duas centrais geotérmicas com a potência total de 23 MW, com produção de energia de 185 GWh. Em Portugal Continental, não se consegue produzir energia elétrica devido às temperaturas existentes, restringindo esta utilização apenas ao aproveitamento de baixa entalpia (máximo de 76 ºC). Este aproveitamento normalmente é feito em cascata, segundo, predominando o aquecimento de águas sanitárias, climatização, e para termas, usando águas termominerais. Para a exploração deste recurso renovável, é necessário conhecer a hidrogeologia do país, e relacioná-la com a fracturação, e acidentes tectónicos. Portugal Continental, está divido em quatros partes distintas a nível hidrogeológico, o Maciço Antigo, a Orla Ocidental, a Bacia Tejo-Sado e a Orla Meridional. Qualquer aproveitamento geotérmico em Portugal terá de atender a estas características, potenciando também, novas explorações geotérmicas orientadas para as pessoas, respeitando os valores sociais, culturais e ambientais. Neste contexto, existem alguns complexos geotérmicos em funcionamento, outros abandonados, e muitos outros em estudo para uma breve aplicação. Um exemplo de sucesso no aproveitamento do calor geotérmico, é o complexo de Chaves, que foi evoluindo desde 1985, até aos dias de hoje, continuando em exploração e em expansão para um melhor servir da população local. A existência de dois furos, e brevemente dum terceiro, servem para o abastecimento duma piscina, dum hotel, das termas, e da balneoterapia. Devido à riqueza a nível das temperaturas, dos caudais, e ao nível das necessidades energéticas existentes, este complexo apresenta um tempo de retorno de investimento de cerca de 7 anos, o que é geralmente considerado para investimentos para fins públicos, como é o caso. No âmbito das investigações agora realizadas, foi constatado que estes projetos suportam a cobertura de alguma incerteza hidrogeológica, dada a importante procura existente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pela importância que os edifícios têm na utilização de energia, a avaliação do seu desempenho energético é de grande relevância, uma vez que, em grande parte, passa por estes a concretização das metas europeias definidas para 2020, no que concerne à diminuição da utilização de energia. Tendo em conta que os edifícios representam 40% do consumo de energia total, e estando o sector em expansão, esta realidade obriga a uma procura de soluções integradas de arquitetura e engenharia que promovam a sustentabilidade dos edifícios. Foi efetuado um estudo num edifício constituído por dois corpos, um mais antigo que funciona como centro de dia e um mais recente que funciona como lar, localizados no concelho de Matosinhos, onde se identificaram os pontos de maior consumo energético, para os quais foram sugeridas alterações no sentido de baixar os custos com a factura energética. Nesta dissertação foi utilizado um software de simulação dinâmica para avaliação do comportamento térmico do edifício nas condições atuais e, posteriormente, foram simulados outros cenários com alterações ao nível da envolvente térmica dos edifícios e dos seus sistemas técnicos, que permitiram identificar algumas medidas de melhoria de eficiência energética. As medidas de melhoria sugeridas implicam uma redução energética, ao nível do consumo de água quente sanitária, consumo de gás natural e electricidade. De entre essas medidas, e com um payback inferior a 8 anos e meio, destacam-se a instalação de redutores de caudal, a substituição da caldeira e da bomba de recirculação, a instalação de painéis solares térmicos e a redução da quantidade de lâmpadas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: ST-elevation myocardial infarction (STEMI) with the culprit lesion in the left main artery is a rare cardiac emergency with a poor prognosis. OBJECTIVE: Review and prognosis evaluation of primary percutaneous coronary intervention (PCI) performed in the setting of STEMI with left main occlusion in a single high-volume center. METHODS: Of the 483 primary or rescue PCIs performed and followed in our hospital during a 24-month period (August 2004 to July 2006), we retrospectively evaluated those involving left main procedures and analyzed in-hospital mortality and major cardiac events (MACE) in a 12-month follow-up. We found nine patients, age 68 +/- 9 years, five male, seven with multivessel disease and two with isolated left main disease. Rescue PCI was performed in three patients and primary PCI in the others. RESULTS: Seven patients presented in cardiogenic shock and two were classified in Killip class II on admission. Inotropic drugs, intra-aortic balloon pump and abciximab were used in eight patients. Drug-eluting stents were used in six patients, bare-metal stents in two, and isolated balloon angioplasty in one. Five patients (55%) died in the hospital and the four discharged home (two of them aged 81 and 82 years) were still alive and free from MACE at 12-month follow-up. CONCLUSIONS: Clinical presentation of STEMI with the culprit lesion in the left main artery was very severe. During PCI, drug-eluting stents, intra-aortic balloon pump and abciximab were used in almost all patients. This entity had a high mortality rate even though primary PCI was performed. Those who survived had a good mid-term prognosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We evaluate the prevalence of intestinal parasites in 504 people and the degree of association between environmental variables and parasites found in population, soil and water in a rural area of Argentina during 2002-2003. A structured survey was used to evaluate the environmental variables and fecal-human, soil and water samples were analyzed. The prevalence of parasites was 45.4%. Most prevalent protozoa were Blastocystis hominis (27.2%) and Giardia lamblia (6.9%), while the most prevalent helminth was Ascaris lumbricoides (3.8%). The analyzed environmental variables showing association (p < 0.05) with presence of parasites in population were: cardboard-tin or wooden house, dirt floor, home or communal water pump, faucet outside the house or public faucet and cesspool or latrine. Parasite forms were found in 82.3% of the soil samples and in 84.2% of the water samples. In both samples we found parasites that were also found in people. In this study we have found deficient sanitary conditions associated with presence of parasites in population and we have evidenced that contaminated soil and water were the source of these parasites.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO: Sessenta e três derivados de hidantoína foram utilizados para avaliar possíveis efeitos de modulação na actividade das bombas de efluxo (BE) na Salmonella NCTC 13349 utilizando um método fluorimétrico semi-automático. Nenhum dos compostos apresentaram actividade anti-bacteriana até concentrações de 240 mg/L. Entre todos os compostos, SZ-7 demonstrou possuir propriedades de modulação de effluxo na presença de glucose. Para testar esta actividade, estirpes de Salmonella resistentes à ciprofloxacina, induzidas a elevados níveis de resistência com sobre-expressão de BE, foram expostas ao SZ-7. Este derivado afectou a susceptibilidade das estirpes à ciprofloxacina. Uma vez que os 63 compostos estudados apresentaram pouco efeito inibitório /cumulativo, apesar de serem conhecidos pelos seus efeitos moduladores de BE-dependentes de iões em eucariotas, foi questionado o papel dos iões na regulação de BE bacterianas, que poderão influenciar a eficácia de novos compostos. Para este estudo, utilizamos a Escherichia coli AG100 como modelo, devido ao extenso conhecimento no que respeita a estrutura e actividade das BE. Devido à importância de iões de cálcio (Ca2+) nos canais de transporte membranar e na actividade de ATPases, a sua actividade na modulação do efluxo foi investigada. De resultados anteriormente obtidos concluiu-se que a pH 5 o efluxo é independente de energia metabólica; contudo, a pH 8 é absolutamente dependente, sendo que o Ca2+ é indispensável para manter a actividade das ATPases bacterianas. A acumulação/effluxo de EtBr pela E. coli AG100 foi determinada na presença/ausência de Ca2+, clorpromazina (inibidor de ligação de Ca2+ a proteínas), e ácido etilenodiamino tetra-acético (quelante de Ca2+). Acumulação/effluxo aumentou a pH 8, contudo o Ca2+ reverte estes efeitos evidenciando a sua importância no funcionamento das BE bacterianas. Em resumo este trabalho colocou em evidência que muitos aspectos bioquímicos e bioenergéticos devem ser tomados em consideração no estudo da resistência bacteriana mediada por BE.------- ABSTRACT: Sixty-three hydantoin derivatives were evaluated for their modulating effects on efflux pump (EP) activity of Salmonella NCTC 13349 utilizing a semi-automatic fluorometric method. None of the compounds presented antibacterial activities at concentrations as high as 240 mg/L. Among all compounds, SZ-7 showed possible efflux modulating activity in the presence of glucose, indicative of a potential EP inhibitor. To verify its potential effects, ciprofloxacin-resistant Salmonella strains, induced to high level resistance with over-expressing EPs, were exposed to SZ-7. This derivative affected the susceptibility of the ciprofloxacin-resistant strains. Since the 63 compounds studied had very low inhibitory/accumulative effects, even though their known for being efficient in modulating ion-driven eukaryotic EPs, we questioned whether ions had a leading role in regulating bacterial EPs, influencing the effectiveness of new compounds. For this study we used Escherichia coli AG100 as a model, due to the extensive knowledge on its EPs structure and activity. Owing the importance of calcium ions (Ca2+) for membrane transport channels and activity of ATPases, the role of Ca2+ was investigated. From previous results we concluded that at pH 5 efflux is independent of metabolic energy; however, at pH 8 it is entirely dependent of metabolic energy and the Ca2+ ions are essential to maintain the activity of bacterial ATPases. Accumulation and efflux of ethidium bromide (EtBr) by E. coli AG100 was determined in the presence and absence of Ca2+, chlorpromazine (inhibitor of Ca2+-binding to proteins), and ethylenediaminetetraacetic acid (Ca2+ chelator). Accumulation of EtBr increased at pH 8; however Ca2+ reversed these effects providing information as to the importance of this ion in the regulation of bacterial EP systems. Overall this work puts in evidence that many biochemical and bioenergetic aspects related to the strains physiology need to be taken into consideration in bacterial drug resistance mediated by EPs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os robots de movimentação de chapa são bastantes úteis para as empresas de metalomecânica. De facto, cada vez mais existem máquinas de corte por jato de água, laser ou outros processos, nos quais os robots apresentam um papel importante na carga e descarga do material. O trabalho realizado apresenta novas soluções aos sistemas de movimentação existentes no mercado, e permite reduzir os custos na movimentação do material. Este projeto serve essencialmente para chapas em trajetória retilínea, e efetuar o seu levantamento do equipamento e deposição em estrutura de suporte (ou viceversa). A vantagem a ter em conta é a diminuição dos custos de movimentação do material. Neste trabalho apresentou-se a metodologia de dimensionamento de um robot automatizado que transporta chapas com um peso máximo de 3500 kg, tendo por base as normas do EC3-P1.8 e o Método de Elementos Finitos (MEF). No decurso do projeto foram abordadas os seguintes temas: Abordagem inicial da geometria através do Solidworks; Dimensionamento da estrutura por software de Elementos Finitos, o Solidworks; Dimensionamento das correntes, carretos/discos ou coroas e rolamentos; Dimensionamento e seleção dos moto-redutores, bomba de vácuo e ventosas; Cálculo das solicitações em cada membro da estrutura por software de análise estrutural, o Multiframe3D, e respetivo dimensionamento das ligações aparafusadas e soldadas; Elaboração dos desenhos de projeto finais, processos de fabrico e custos; Dimensionamento do acionamento, MG e disposição dos dispositivos no quadro elétrico. Como conclusão refere-se que se conseguiu realizar o projeto e obter uma solução final otimizada, com a ajuda de ferramentas importantes, como sejam o MEF, resultando num equipamento cujas solicitações para a estrutura e sistema de movimentação foram otimizadas, resultando num equipamento eficiente, robusto, seguro e de custo reduzido.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The integration of wind power in eletricity generation brings new challenges to unit commitment due to the random nature of wind speed. For this particular optimisation problem, wind uncertainty has been handled in practice by means of conservative stochastic scenario-based optimisation models, or through additional operating reserve settings. However, generation companies may have different attitudes towards operating costs, load curtailment, or waste of wind energy, when considering the risk caused by wind power variability. Therefore, alternative and possibly more adequate approaches should be explored. This work is divided in two main parts. Firstly we survey the main formulations presented in the literature for the integration of wind power in the unit commitment problem (UCP) and present an alternative model for the wind-thermal unit commitment. We make use of the utility theory concepts to develop a multi-criteria stochastic model. The objectives considered are the minimisation of costs, load curtailment and waste of wind energy. Those are represented by individual utility functions and aggregated in a single additive utility function. This last function is adequately linearised leading to a mixed-integer linear program (MILP) model that can be tackled by general-purpose solvers in order to find the most preferred solution. In the second part we discuss the integration of pumped-storage hydro (PSH) units in the UCP with large wind penetration. Those units can provide extra flexibility by using wind energy to pump and store water in the form of potential energy that can be generated after during peak load periods. PSH units are added to the first model, yielding a MILP model with wind-hydro-thermal coordination. Results showed that the proposed methodology is able to reflect the risk profiles of decision makers for both models. By including PSH units, the results are significantly improved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este estudo consiste na caracterização da eficiência energética de uma bomba de calor de expansão direta que utiliza a energia solar como fonte térmica. De uma forma geral, teve-se a obrigação de procurar cada vez mais recursos renováveis e neste sentido a bomba de calor de expansão direta tem um papel importante no aquecimento de águas quentes sanitárias (AQS). Como ponto de partida, foi realizada uma descrição detalhada sobre todos os equipamentos da bomba de calor e elaborado um desenho técnico que identifica todos os componentes. No laboratório (casa inteligente) realizaram-se vários ensaios a fim de interpretar com rigor os resultados obtidos do desempenho da bomba de calor (COP) e do fator médio de desempenho sazonal (SPF). No início, realizaram-se ensaios para determinar as perdas estáticas do sistema termodinâmico, de seguida foram elaborados ensaios segundo a norma EN 16147 e por fim, ensaios de acordo com o perfil de utilização de AQS definido. No estudo experimental do COP, obteve-se uma elevada eficiência energética com um valor médio de 4,12. O COP aumenta para valores médios de 5 quando a temperatura de água no termoacumulador desce para 35ºC. Verificou-se que durante o período diurno o COP aumenta aproximadamente de 10% relativamente ao período noturno. A potência elétrica é mais elevada (450W) quando a água no termoacumulador está perto da temperatura desejável (55ºC), originando um esforço maior da bomba de calor. No estudo experimental do SPF, verificou-se que nos ensaios segundo a norma EN16147 os valores obtidos variaram entre 1,39 e 1,50 (Classe “B”). No estudo realizado de acordo com o perfil de utilização de AQS definido pelo utilizador, o SPF é superior em 12% relativamente ao obtido segundo os ensaios realizados de acordo a norma EN16147. Verificou-se que o aumento da temperatura do ar exterior implica um aumento do SPF (cerca de 2% a 5%), enquanto a energia solar não influência nos resultados.