901 resultados para Zurich
Resumo:
Structured cardiac rehabilitation goes back to the late 1960s also in Switzerland and in the beginning was only available in rehabilitation clinics. In 1972 the first ambulatory rehabilitation programs became available to patients in Zurich and Bern. In the following years, in addition to the increasing number of rehabilitation centers for inpatients, more and more ambulatory rehabilitation programs were developed, especially in the larger Midlands population area in German and French-speaking Switzerland. In 1985 the Swiss Working Group of Cardiac Rehabilitation (SAKR) was initiated as an official working group of the Swiss Society of Cardiology and one of its first tasks was to establish a list of the institutions for cardiac rehabilitation in Switzerland. At that time there were 42 rehabilitation programs for a population of approx. 6.5 million, 21 for inpatients and 21 ambulatory; however, 90% of the patients were in inpatient programs. In 1992 the SAKR group defined the quality criteria which were to be applied for official recognition of institutions for cardiac rehabilitation in Switzerland. Due to these criteria, plus the fact that an increasing number of rehabilitation clinics in the mountains had been closed down, the number of inpatient rehabilitation centers decreased from 21 to 11 between 1989 and 2011, whereas the number of ambulatory programs increased from 21 to 51. The ambulatory rehabilitation centers are partially organized by local medical groups; however, most have integrated their activities into the local hospitals. The trend shows a developing preference for ambulatory rehabilitation. More and more elderly, polymorbid patients, however, will still need care in inpatient programs.
Resumo:
This paper presents our ongoing work on enterprise IT integration of sensor networks based on the idea of service descriptions and applying linked data principles to them. We argue that using linked service descriptions facilitates a better integration of sensor nodes into enterprise IT systems and allows SOA principles to be used within the enterprise IT and within the sensor network itself.
Resumo:
BACKGROUND: In general cantons regulate and control the Swiss health service system; patient flows within and between cantons are thereby partially disregarded. This paper develops an alternative spatial model, based upon the construction of orthopedic hospital service areas (HSAOs), and introduces indices for the analysis of patient streams in order to identify areas, irrespective of canton, with diverse characteristics, importance, needs, or demands. METHODS: HSAOs were constructed using orthopedic discharge data. Patient streams between the HSAOs were analysed by calculating three indices: the localization index (% local residents discharged locally), the netindex (the ratio of discharges of nonlocal incoming residents to outgoing local residents), and the market share index (% of local resident discharges of all discharges in local hospitals). RESULTS: The 85 orthopedic HSAOs show a median localization index of 60.8%, a market share index of 75.1%, and 30% of HSAOs have a positive netindex. Insurance class of bed, admission type, and patient age are partially but significantly associated with those indicators. A trend to more centrally provided health services can be observed not only in large urban HSAOs such as Geneva, Bern, Basel, and Zurich, but also in HSAOs in mountain sport areas such as Sion, Davos, or St.Moritz. Furthermore, elderly and emergency patients are more frequently treated locally than younger people or those having elective procedures. CONCLUSION: The division of Switzerland into HSAOs provides an alternative spatial model for analysing and describing patient streams for health service utilization. Because this small area model allows more in-depth analysis of patient streams both within and between cantons, it may improve support and planning of resource allocation of in-patient care in the Swiss healthcare system.
Resumo:
CONTEXT: There is strong evidence for a physiological hyperreactivity to stress in systemic hypertension, but data on associated or potentially moderating psychological factors are scarce. OBJECTIVE: The objective of the study was to identify psychological correlates of physiological stress reactivity in systemic hypertension. DESIGN: This was a cross-sectional, quasi-experimentally controlled study. Study participants underwent an acute standardized psychosocial stress task combining public speaking and mental arithmetic in front of an audience. SETTING: The study was conducted in the population in the state of Zurich, Switzerland. SUBJECTS: Subjects included 22 hypertensive and 26 normotensive men (mean +/- sem 44 +/- 2 yr). MAIN OUTCOME MEASURES: We assessed the psychological measures social support, emotional regulation, and cognitive appraisal of the stressful situation. Moreover, we measured salivary cortisol and plasma epinephrine and norepinephrine before and after stress and several times up to 60 min thereafter as well as blood pressure and heart rate. RESULTS: We found poorer hedonistic emotional regulation (HER) and lower perceived social support in hypertensives, compared with normotensives (P < 0.01). Compared with normotensives, hypertensives showed higher cortisol, epinephrine, and norepinephrine secretions after stress (P < 0.038) as well as higher systolic and diastolic blood pressure (P < 0.001). Cortisol reactivity and norepinephrine secretion were highest in hypertensive men with low HER (P < 0.05). In contrast, hypertensives with high HER did not significantly differ from normotensives in both cortisol and norepinephrine secretion after stress. Epinephrine secretion was highest in hypertensives with low social support but was not different between hypertensives with high social support and normotensives. CONCLUSIONS: The findings suggest that both low social support and low HER are associated with elevated stress hormone reactivity in systemic hypertension.
Resumo:
OBJECTIVE: To examine the Young's modulus of the human amniotic membranes, as well as its relationship to gestational age. To determine whether cellular and material-related parameters affect this modulus. STUDY DESIGN: In a prospective study at the Obstetric outpatient clinic of the University Hospital Zurich Young's modulus, thickness and mesenchymal:epithelial cell ratio of amniotic membranes of preterm (N=23) and term (N=40) placentae were examined. Significance (P<0.05) was calculated with the Mann-Whitney two-sample rank sum test and Wilcoxon signed rank test, while correlations were made using the Spearman's correlation. RESULTS: The Young's modulus of preterm amniotic membranes was significantly higher than that of term membranes. It varied within the same amniotic membrane. The thickness of the amnion in both preterm and term membranes did not differ significantly. The thinner the preterm and term amniotic membranes, the higher the Young's modulus was. There was no relation to the mesenchymal:epithelial cell ratio in the amnion. CONCLUSIONS: Preterm amniotic membranes are stiffer than term amniotic membranes. Tentatively, we hypothesise that there may be a correlation between the extracellular matrix components and the elastic properties of the membrane.
Resumo:
The novel tabletop miniaturized radiocarbon dating system (MICADAS) at ETH Zurich features a hybrid Cs sputter negative ion source for the measurement of solid graphite and gaseous CO2 samples. The source produces stable currents of up to 6 mu A C- out of gaseous samples with an efficiency of 3-6%. A gas feeding system has been set up that enables constant dosing of CO2 into the Cs sputter ion source and ensures stable measuring conditions. The system is based on a syringe in which CO2 gas is mixed with He and then pressed continuously into the ion source at a constant flow rate. Minimized volumes allow feeding samples of 3-30 mu g carbon quantitatively into the ion source. In order to test the performance of the system, several standards and blanks have successfully been measured. The ratios of C-14/C-12 could be repeated within statistical errors to better than 1.0% and the C-13/C-12 ratios to better than 0.2%. The blank was < 1 pMC.
Resumo:
OBJECTIVES: The objectives of this in vitro study were (1) to assess the bond strength of the universal cement RelyX Unicem to dentin and to compare it with three conventional resin cements, (2) to test the influence of aging on their bonding capacity and (3) to test the influence of the operator on bonding quality by performing the same test in two different centers. METHODS: 160 third molars, divided into 80 for tests at the University of Zurich (Z) and 80 for tests at the University of Berne (B), were assigned to 2 x 8 subgroups of 10 teeth each. The specimens were prepared with the corresponding bonding agents and acrylic rods were luted either with RelyX Unicem (U), RelyX ARC (A), Multilink (M) or Panavia 21 (P). All specimens were stored in water for 24h (W) and half of the specimens were subjected to 1500 cycles of thermocycling (5 degrees C and 55 degrees C) (T). Bond strength was measured by means of a shear test. RESULTS: After water storage RelyX Unicem exhibited lowest bond strength (UWZ: 9.2+/-1.6 MPa, UWB: 9.9+/-1.2 MPa, AWZ: 15.3+/-6.0 MPa, AWB: 12.2+/-4.3 MPa, MWZ: 15.6+/-3.3 MPa, MWB: 12.4 MPa+/-2.4, PWZ: 13.4+/-2.9 MPa, PWB: 14.9+/-2.6 MPa). Thermocycling affected the bonding performance of all four cements. However, bond strength of RelyX Unicem was least influenced by thermocycling (UTZ: 9.4+/-2.9 MPa, UTB: 8.6+/-1.3 MPa, ATZ: 11.4+/-6.3 MPa, ATB: 13.3+/-3.7 MPa, MTZ: 15.4+/-3.1 MPa, MTB: 10.3+/-2.4 MPa, PTZ: 11.1+/-2.8 MPa, PTB: 11.3+/-2.8 MPa). SIGNIFICANCE: Although the bond strength of RelyX Unicem to dentin was lower in comparison to RelyX ARC, Multilink and Panavia 21, its bond strength was less sensitive to variations in handling and aging.