940 resultados para Veterinary instruments and apparatus
Resumo:
Langstaff, David; Chase, T., (2007) 'A multichannel detector array with 768 pixels developed for electron spectroscopy', Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 573(1-2) pp.169-171 RAE2008
Resumo:
Langstaff, David; Bushell, A.; Chase, T.; Evans, D.A., (2005) 'A fully integrated multi-channel detector for electron spectroscopy', Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms 238 pp.219-223 RAE2008 Synchrotron Radiation in Materials Science ? Proceedings of the 4th Conference on Synchrotron Radiation in Materials Science 4th Conference on Synchrotron Radiation in Materials Science
Resumo:
Monografia apresentada à Universidade Fernando Pessoa para obtenção do grau Licenciada em Medicina Dentária
Resumo:
The theme of New City utilizes ever changing time signatures and the main theme creates a dynamic dialogue between the melody instruments and the percusssion section.
Resumo:
In order to determine the size-resolved chemical composition of single particles in real-time an ATOFMS was deployed at urban background sites in Paris and Barcelona during the MEGAPOLI and SAPUSS monitoring campaigns respectively. The particle types detected during MEGAPOLI included several carbonaceous species, metal-containing types and sea-salt. Elemental carbon particle types were highly abundant, with 86% due to fossil fuel combustion and 14% attributed to biomass burning. Furthermore, 79% of the EC was apportioned to local emissions and 21% to continental transport. The carbonaceous particle types were compared with quantitative measurements from other instruments, and while direct correlations using particle counts were poor, scaling of the ATOFMS counts greatly improved the relationship. During SAPUSS carbonaceous species, sea-salt, dust, vegetative debris and various metal-containing particle types were identified. Throughout the campaign the site was influenced by air masses altering the composition of particles detected. During North African air masses the city was heavily influenced by Saharan dust. A regional stagnation was also observed leading to a large increase in carbonaceous particle counts. While the ATOFMS provides a list of particle types present during the measurement campaigns, the data presented is not directly quantitative. The quantitative response of the ATOFMS to metals was examined by comparing the ion signals within particle mass spectra and to hourly mass concentrations of; Na, K, Ca, Ti, V, Cr, Mn, Fe, Zn and Pb. The ATOFMS was found to have varying correlations with these metals depending on sampling issues such as matrix effects. The strongest correlations were observed for Al, Fe, Zn, Mn and Pb. Overall the results of this work highlight the excellent ability of the ATOFMS in providing composition and mixing state information on atmospheric particles at high time resolution. However they also show its limitations in delivering quantitative information directly.
Resumo:
We developed a ratiometric method capable of estimating total hemoglobin concentration from optically measured diffuse reflectance spectra. The three isosbestic wavelength ratio pairs that best correlated to total hemoglobin concentration independent of saturation and scattering were 545/390, 452/390, and 529/390 nm. These wavelength pairs were selected using forward Monte Carlo simulations which were used to extract hemoglobin concentration from experimental phantom measurements. Linear regression coefficients from the simulated data were directly applied to the phantom data, by calibrating for instrument throughput using a single phantom. Phantoms with variable scattering and hemoglobin saturation were tested with two different instruments, and the average percent errors between the expected and ratiometrically-extracted hemoglobin concentration were as low as 6.3%. A correlation of r = 0.88 between hemoglobin concentration extracted using the 529/390 nm isosbestic ratio and a scalable inverse Monte Carlo model was achieved for in vivo dysplastic cervical measurements (hemoglobin concentrations have been shown to be diagnostic for the detection of cervical pre-cancer by our group). These results indicate that use of such a simple ratiometric method has the potential to be used in clinical applications where tissue hemoglobin concentrations need to be rapidly quantified in vivo.
Resumo:
Throughout the piano’s history, certain composers have created innovations in the areas of virtuosity and sonority. These innovations came not only from the composers’ imagination, but also from the development of instruments and changes in musical style from one period to another. To investigate what kinds of innovations these pianist composers made, I divided them into technique and sound from Mozart to Cowell. I chose two-piano music (Sonata in D major, K.448 by Mozart and Rachmaninoff’s Second Suite) to demonstrate their experiments with varieties of textures and sonorities, using different registers of the two pianos orchestrally. En Blanc et noir by Debussy shows this composer’s deep interest and originality in piano sonorities. For solo piano music, Beethoven’s Piano Sonata Op.53 shows extensive technical invention. His use of long pedal effects shows a pianistic possibility not explored by Mozart. Hummel’s Piano Sonata in D major represents orchestral devices as well as pianistic techniques showing recent developments in the instrument. Chopin’s Ballade No.3 and Scherzo No.3 show virtuosic moments and also the expanded range of the keyboard. His Nocturne Op.27, no.2, with its sonorities resulting from the combination of pedal, and widespread accompaniments derived from Alberti bass figures, is a perfect example of Chopin’s characteristic sound-world. “Vallée d’Obermann” by Liszt uses many virtuosic techniques as well as the extreme wide ranges of keyboard in both hands to create dramatic contrasts of texture. Debussy’s etude, “Pour les Sonorités opposés” is probably the first etude designed for sonority rather than for keyboard virtuosity. Albeniz’s “Evocación” and “Triana” show Spanish atmosphere. Prokofiev’s Sonata no.3 shows frequent motoric driving elements that demand percussive virtuosity. Cowell’s piano music is some of the earliest to explore the sonorities of tone clusters and playing on the strings. This performance dissertation consists of three recitals performed in the Orchestra Room, Leah Smith Hall, and Gildenhorn Recital Hall at the University of Maryland, College Park. These recitals are documented on compact disc recordings that are housed within the University of Maryland Library System.
Resumo:
The problem of achieving super-resolution, i.e. resolution beyond the classical Rayleigh distance of half a wavelength, is a real challenge in several imaging problems. The development of computer-assisted instruments and the possibility of inverting the recorded data has clearly modified the traditional concept of resolving power of an instrument. We show that, in the framework of inverse problem theory, the achievable resolution limit arises no longer from a universal rule but instead from a practical limitation due to noise amplification in the data inversion process. We analyze under what circumstances super-resolution can be achieved and we show how to assess the actual resolution limits in a given experiment, as a function of the noise level and of the available a priori knowledge about the object function. We emphasize the importance of the a priori knowledge of its effective support and we show that significant super-resolution can be achieved for "subwavelength sources", i.e. objects which are smaller than the probing wavelength.
Resumo:
We report on a study comparing absolute K-alpha yield from Ti foils measured with a calibrated system of an X-ray CCD coupled to a curved LiF Von-Hamos crystal spectrometer to the difference in the signals measured simultaneously with two similar photodiodes fitted with two different filters. Our data indicate that a combination of photodiodes with different filters could be developed into an alternative and inexpensive diagnostic for monitoring single shot pulsed emission in a narrow band of X-ray region.
Resumo:
El objetivo de este trabajo es analizar la frecuencia con que se utilizan diferentes instrumentos y procedimientos de evaluación desde el punto de vista del profesorado, del alumnado y de los egresados en la formación inicial de maestros y profesores especialistas en Educación Física, así como el grado de coherencia –relación- percibido por cada uno de esos grupos implicados entre dichos instrumentos y procedimientos de evaluación y el desarrollo de las competencias profesionales que se pretende adquieran los estudiantes. La muestra objeto de estudio está compuesta por 199 alumnos, 67 egresados y 53 profesores de las titulaciones de Magisterio (especialidad de Educación Física) y Ciencias de la Actividad Física y el Deporte de las universidades de Valladolid, Salamanca y León. Los resultados muestran una clara discrepancia entre los distintos grupos analizados, tanto en lo referido al tipo de instrumentos de evaluación utilizados, como en la valoración del grado de coherencia entre estos y el desarrollo de las competencias profesionales de los futuros maestros.
Resumo:
Chloramphenicol is a broad-spectrum antibiotic shown to have specific activity against a wide variety of organisms that are causative agents of several disease conditions in domestic animals. Chloramphenicol has been banned for use in food-producing animals for its serious adverse toxic effects in humans. Due to the harmful effects of chloramphenicol residues livestock products should be free of any traces of these residues. Several analytical methods are available for chloramphenicol analysis but sensitive methods are required in order to ensure that no traces of chloramphenicol residues are present in edible animal products. In order to prevent the illegal use of chloramphenicol, regulatory control of its residues in food of animal origin is essential. A competitive enzyme-linked immunosorbent assay for chloramphenicol has been locally developed and optimized for the detection of chloramphenicol in sheep serum. In the assay, chloramphenicol in the test samples and that in chloramphenicol-horseradish peroxidase conjugate compete for antibodies raised against the drug in camels and immobilized on a microtitre plate. Tetramethylbenzidine-hydrogen peroxide (TMB/H2O2) is used as chromogen-substrate system. The assay has a detection limit of 0.1 ng/mL of serum with a high specificity for chloramphenicol. Cross-reactivity with florfenicol, thiamphenicol, penicillin, tetracyclines and sulfamethazine was not observed. The assay was able to detect chloramphenicol concentrations in normal sheep serum for at least 1 week after intramuscular injection with the drug at a dose of 25 mg/kg body weight (b.w.). The assay can be used as a screening tool for chloramphenicol use in animals.