987 resultados para Upper-extremity Volume
Resumo:
Neurally adjusted ventilatory assist (NAVA) is a ventilation assist mode that delivers pressure in proportionality to electrical activity of the diaphragm (Eadi). Compared to pressure support ventilation (PS), it improves patient-ventilator synchrony and should allow a better expression of patient's intrinsic respiratory variability. We hypothesize that NAVA provides better matching in ventilator tidal volume (Vt) to patients inspiratory demand. 22 patients with acute respiratory failure, ventilated with PS were included in the study. A comparative study was carried out between PS and NAVA, with NAVA gain ensuring the same peak airway pressure as PS. Robust coefficients of variation (CVR) for Eadi and Vt were compared for each mode. The integral of Eadi (ʃEadi) was used to represent patient's inspiratory demand. To evaluate tidal volume and patient's demand matching, Range90 = 5-95 % range of the Vt/ʃEadi ratio was calculated, to normalize and compare differences in demand within and between patients and modes. In this study, peak Eadi and ʃEadi are correlated with median correlation of coefficients, R > 0.95. Median ʃEadi, Vt, neural inspiratory time (Ti_ ( Neural )), inspiratory time (Ti) and peak inspiratory pressure (PIP) were similar in PS and NAVA. However, it was found that individual patients have higher or smaller ʃEadi, Vt, Ti_ ( Neural ), Ti and PIP. CVR analysis showed greater Vt variability for NAVA (p < 0.005). Range90 was lower for NAVA than PS for 21 of 22 patients. NAVA provided better matching of Vt to ʃEadi for 21 of 22 patients, and provided greater variability Vt. These results were achieved regardless of differences in ventilatory demand (Eadi) between patients and modes.
Resumo:
BACKGROUND: Recommended oral voriconazole (VRC) doses are lower than intravenous doses. Because plasma concentrations impact efficacy and safety of therapy, optimizing individual drug exposure may improve these outcomes. METHODS: A population pharmacokinetic analysis (NONMEM) was performed on 505 plasma concentration measurements involving 55 patients with invasive mycoses who received recommended VRC doses. RESULTS: A 1-compartment model with first-order absorption and elimination best fitted the data. VRC clearance was 5.2 L/h, the volume of distribution was 92 L, the absorption rate constant was 1.1 hour(-1), and oral bioavailability was 0.63. Severe cholestasis decreased VRC elimination by 52%. A large interpatient variability was observed on clearance (coefficient of variation [CV], 40%) and bioavailability (CV 84%), and an interoccasion variability was observed on bioavailability (CV, 93%). Lack of response to therapy occurred in 12 of 55 patients (22%), and grade 3 neurotoxicity occurred in 5 of 55 patients (9%). A logistic multivariate regression analysis revealed an independent association between VRC trough concentrations and probability of response or neurotoxicity by identifying a therapeutic range of 1.5 mg/L (>85% probability of response) to 4.5 mg/L (<15% probability of neurotoxicity). Population-based simulations with the recommended 200 mg oral or 300 mg intravenous twice-daily regimens predicted probabilities of 49% and 87%, respectively, for achievement of 1.5 mg/L and of 8% and 37%, respectively, for achievement of 4.5 mg/L. With 300-400 mg twice-daily oral doses and 200-300 mg twice-daily intravenous doses, the predicted probabilities of achieving the lower target concentration were 68%-78% for the oral regimen and 70%-87% for the intravenous regimen, and the predicted probabilities of achieving the upper target concentration were 19%-29% for the oral regimen and 18%-37% for the intravenous regimen. CONCLUSIONS: Higher oral than intravenous VRC doses, followed by individualized adjustments based on measured plasma concentrations, improve achievement of the therapeutic target that maximizes the probability of therapeutic response and minimizes the probability of neurotoxicity. These findings challenge dose recommendations for VRC.
Resumo:
BACKGROUND: Low 24-hour urine volume (24 UV) may be a significant risk factor for decline in kidney function. We therefore aimed to study associated markers and possible determinants of 24 UV in a sample of the Swiss population. METHODS: The cross-sectional Swiss Salt Study included a population-based sample of 1535 (746 men and 789 women) individuals from three linguistic regions of Switzerland. Data from 1300 subjects were available for the present analysis. 24 UV was measured using 24-hour urine collection. Determinants of 24 UV were identified using multivariable linear regression models. RESULTS: In bivariate analysis, 24 UV was higher in women compared to men (2000 ml/24 h [interquartile range (IQR): 1354, 2562] versus 1780 ml/24 h [IQR: 1244, 2360], p = 0.002). In multivariable regression analyses, independent associated markers of 24 UV were female sex (β = 280, 95% confidence interval [CI]: 174, 386, p < 0.0001), fluid intake (β = 604, 95% CI: 539, 670, p < 0.0001), sodium excretion (β = 4.2, 95% CI: 3.4, 4.9, p < 0.0001) age (β = 6.6, CI: 3.4, 9.7, p < .0001), creatinine clearance (β = 2.4, CI: 0.2, 4.6, p = 0.04), living in the German-speaking part of Switzerland (β = 124, CI: 29, 219, p = 0.01), alcohol consumption (β = 41, CI: 9, 73, p = 0.01 for increasing categories of alcohol consumption), body mass index (β = -32, CI: -45, -18, p < 0.0001), current smoking (β = -146, CI: -265, -26, p = 0.02), and consumption of meat and cold cut (β = -56, CI: -108, -5, p = 0.03). CONCLUSION: In this large population-based, cross-sectional study, we found several strong and independent correlates for 24 UV. These findings may be important to improve our understanding in the development of chronic kidney disease.
Resumo:
Mitochondrial (M) and lipid droplet (L) volume density (vd) are often used in exercise research. Vd is the volume of muscle occupied by M and L. The means of calculating these percents are accomplished by applying a grid to a 2D image taken with transmission electron microscopy; however, it is not known which grid best predicts these values. PURPOSE: To determine the grid with the least variability of Mvd and Lvd in human skeletal muscle. METHODS: Muscle biopsies were taken from vastus lateralis of 10 healthy adults, trained (N=6) and untrained (N=4). Samples of 5-10mg were fixed in 2.5% glutaraldehyde and embedded in EPON. Longitudinal sections of 60 nm were cut and 20 images were taken at random at 33,000x magnification. Vd was calculated as the number of times M or L touched two intersecting grid lines (called a point) divided by the total number of points using 3 different sizes of grids with squares of 1000x1000nm sides (corresponding to 1µm2), 500x500nm (0.25µm2) and 250x250nm (0.0625µm2). Statistics included coefficient of variation (CV), 1 way-BS ANOVA and spearman correlations. RESULTS: Mean age was 67 ± 4 yo, mean VO2peak 2.29 ± 0.70 L/min and mean BMI 25.1 ± 3.7 kg/m2. Mean Mvd was 6.39% ± 0.71 for the 1000nm squares, 6.01% ± 0.70 for the 500nm and 6.37% ± 0.80 for the 250nm. Lvd was 1.28% ± 0.03 for the 1000nm, 1.41% ± 0.02 for the 500nm and 1.38% ± 0.02 for the 250nm. The mean CV of the three grids was 6.65% ±1.15 for Mvd with no significant differences between grids (P>0.05). Mean CV for Lvd was 13.83% ± 3.51, with a significant difference between the 1000nm squares and the two other grids (P<0.05). The 500nm squares grid showed the least variability between subjects. Mvd showed a positive correlation with VO2peak (r = 0.89, p < 0.05) but not with weight, height, or age. No correlations were found with Lvd. CONCLUSION: Different size grids have different variability in assessing skeletal muscle Mvd and Lvd. The grid size of 500x500nm (240 points) was more reliable than 1000x1000nm (56 points). 250x250nm (1023 points) did not show better reliability compared with the 500x500nm, but was more time consuming. Thus, choosing a grid with square size of 500x500nm seems the best option. This is particularly relevant as most grids used in the literature are either 100 points or 400 points without clear information on their square size.
Resumo:
During upper blepharoplasty, myocutaneous excess and fat pads are treated using an anterior approach. Eyelid malpositions such as involutional ptosis or lid retraction could be associated and should be treated with associated procedures. Aponeurotic surgery on the levator muscle can make use of the same anterior approach, with the major difficulty of dosage. In cases of ptosis with a positive epinephrine test or minor muscular retraction, the Muller muscle-conjunctival surgery via a posterior approach seems to be more reproducible. Double-approach techniques are described.
Resumo:
PURPOSE: To understand the reasons for differences in the delineation of target volumes between physicians. MATERIAL AND METHODS: 18 Swiss radiooncology centers were invited to delineate volumes for one prostate and one head-and-neck case. In addition, a questionnaire was sent to evaluate the differences in the volume definition (GTV [gross tumor volume], CTV [clinical target volume], PTV [planning target volume]), the various estimated margins, and the nodes at risk. Coherence between drawn and stated margins by centers was calculated. The questionnaire also included a nonspecific series of questions regarding planning methods in each institution. RESULTS: Fairly large differences in the drawn volumes were seen between the centers in both cases and also in the definition of volumes. Correlation between drawn and stated margins was fair in the prostate case and poor in the head-and-neck case. The questionnaire revealed important differences in the planning methods between centers. CONCLUSION: These large differences could be explained by (1) a variable knowledge/interpretation of ICRU definitions, (2) variable interpretations of the potential microscopic extent, (3) difficulties in GTV identification, (4) differences in the concept, and (5) incoherence between theory (i.e., stated margins) and practice (i.e., drawn margins).
Resumo:
Red blood cell (RBC) parameters such as morphology, volume, refractive index, and hemoglobin content are of great importance for diagnostic purposes. Existing approaches require complicated calibration procedures and robust cell perturbation. As a result, reference values for normal RBC differ depending on the method used. We present a way for measuring parameters of intact individual RBCs by using digital holographic microscopy (DHM), a new interferometric and label-free technique with nanometric axial sensitivity. The results are compared with values achieved by conventional techniques for RBC of the same donor and previously published figures. A DHM equipped with a laser diode (lambda = 663 nm) was used to record holograms in an off-axis geometry. Measurements of both RBC refractive indices and volumes were achieved via monitoring the quantitative phase map of RBC by means of a sequential perfusion of two isotonic solutions with different refractive indices obtained by the use of Nycodenz (decoupling procedure). Volume of RBCs labeled by membrane dye Dil was analyzed by confocal microscopy. The mean cell volume (MCV), red blood cell distribution width (RDW), and mean cell hemoglobin concentration (MCHC) were also measured with an impedance volume analyzer. DHM yielded RBC refractive index n = 1.418 +/- 0.012, volume 83 +/- 14 fl, MCH = 29.9 pg, and MCHC 362 +/- 40 g/l. Erythrocyte MCV, MCH, and MCHC achieved by an impedance volume analyzer were 82 fl, 28.6 pg, and 349 g/l, respectively. Confocal microscopy yielded 91 +/- 17 fl for RBC volume. In conclusion, DHM in combination with a decoupling procedure allows measuring noninvasively volume, refractive index, and hemoglobin content of single-living RBCs with a high accuracy.
Resumo:
Background: Previous studies reported an increase of mean platelet volume (MPV) in patients with acute ischemic stroke. However, its correlation with stroke severity has not been investigated. Moreover, studies on the association of MPV with functional outcome yielded inconsistent results. Methods: We included all consecutive ischemic stroke patients admitted to CHUV (Centre Hospitalier Universitaire Vaudois) Neurology Service within 24 h after stroke onset who had MPV measured on admission. The association of MPV with stroke severity (NIHSS score at admission and at 24 h) and outcome (Rankin Scale score at 3 and 12 months) was analyzed in univariate analysis. The chi(2) test was performed to compare the frequency of minor strokes (NIHSS score </=4) and good functional outcome (Rankin Scale score </=2) across MPV quartiles. The ANOVA test was used to compare MPV between stroke subtypes according to the TOAST classification. Student's two-tailed unpaired t test was performed to compare MPV between lacunar and nonlacunar strokes. MPV was generated at admission by the Sysmex XE-2100 automated cell counter (Sysmex Corporation, Kobe, Japan) from EDTA blood samples. Results: There was no significant difference in the frequency of minor strokes (p = 0.46) and good functional outcome (p = 0.06) across MPV quartiles. MPV was not associated with stroke severity or outcome in univariate analysis. There was no significant difference in MPV between stroke subtypes according to the TOAST classification (p = 0.173) or between lacunar and nonlacunar strokes (10.50 +/- 0.91 vs. 10.40 +/- 0.81 fl, p = 0.322). Conclusions: MPV, assessed within 24 h after ischemic stroke onset, is not associated with stroke severity or functional outcome.
Resumo:
Still nowadays amputations are frequently performed in our country. In diabetic patients the incidence of an amputation is 25 times higher than in the normal population. All possibilities of revascularisation or limb salvage must be excluded by a multidisciplinary approach before choosing an amputation. Once the decision is taken the good level of amputation and the correct technique have to determined. The goal of this article is to describe which clinical and paraclinical parameters will help the surgeon to choose the best level of amputation, which techniques are to be used for the amputation and to finally give some information about re-education and the fitting of an orthesis or prosthesis.
Resumo:
BACKGROUND: Increasing the appropriateness of use of upper gastrointestinal (GI) endoscopy is important to improve quality of care while at the same time containing costs. This study explored whether detailed explicit appropriateness criteria significantly improve the diagnostic yield of upper GI endoscopy. METHODS: Consecutive patients referred for upper GI endoscopy at 6 centers (1 university hospital, 2 district hospitals, 3 gastroenterology practices) were prospectively included over a 6-month period. After controlling for disease presentation and patient characteristics, the relationship between the appropriateness of upper GI endoscopy, as assessed by explicit Swiss criteria developed by the RAND/UCLA panel method, and the presence of relevant endoscopic lesions was analyzed. RESULTS: A total of 2088 patients (60% outpatients, 57% men) were included. Analysis was restricted to the 1681 patients referred for diagnostic upper GI endoscopy. Forty-six percent of upper GI endoscopies were judged to be appropriate, 15% uncertain, and 39% inappropriate by the explicit criteria. No cancer was found in upper GI endoscopies judged to be inappropriate. Upper GI endoscopies judged appropriate or uncertain yielded significantly more relevant lesions (60%) than did those judged to be inappropriate (37%; odds ratio 2.6: 95% CI [2.2, 3.2]). In multivariate analyses, the diagnostic yield of upper GI endoscopy was significantly influenced by appropriateness, patient gender and age, treatment setting, and symptoms. CONCLUSIONS: Upper GI endoscopies performed for appropriate indications resulted in detecting significantly more clinically relevant lesions than did those performed for inappropriate indications. In addition, no upper GI endoscopy that resulted in a diagnosis of cancer was judged to be inappropriate. The use of such criteria improves patient selection for upper GI endoscopy and can thus contribute to efforts aimed at enhancing the quality and efficiency of care. (Gastrointest Endosc 2000;52:333-41).
Resumo:
The objective of this work is to present a multitechnique approach to define the geometry, the kinematics, and the failure mechanism of a retrogressive large landslide (upper part of the La Valette landslide, South French Alps) by the combination of airborne and terrestrial laser scanning data and ground-based seismic tomography data. The advantage of combining different methods is to constrain the geometrical and failure mechanism models by integrating different sources of information. Because of an important point density at the ground surface (4. 1 points m?2), a small laser footprint (0.09 m) and an accurate three-dimensional positioning (0.07 m), airborne laser scanning data are adapted as a source of information to analyze morphological structures at the surface. Seismic tomography surveys (P-wave and S-wave velocities) may highlight the presence of low-seismic-velocity zones that characterize the presence of dense fracture networks at the subsurface. The surface displacements measured from the terrestrial laser scanning data over a period of 2 years (May 2008?May 2010) allow one to quantify the landslide activity at the direct vicinity of the identified discontinuities. An important subsidence of the crown area with an average subsidence rate of 3.07 m?year?1 is determined. The displacement directions indicate that the retrogression is controlled structurally by the preexisting discontinuities. A conceptual structural model is proposed to explain the failure mechanism and the retrogressive evolution of the main scarp. Uphill, the crown area is affected by planar sliding included in a deeper wedge failure system constrained by two preexisting fractures. Downhill, the landslide body acts as a buttress for the upper part. Consequently, the progression of the landslide body downhill allows the development of dip-slope failures, and coherent blocks start sliding along planar discontinuities. The volume of the failed mass in the crown area is estimated at 500,000 m3 with the sloping local base level method.
Resumo:
In this paper we propose a stabilized conforming finite volume element method for the Stokes equations. On stating the convergence of the method, optimal a priori error estimates in different norms are obtained by establishing the adequate connection between the finite volume and stabilized finite element formulations. A superconvergence result is also derived by using a postprocessing projection method. In particular, the stabilization of the continuous lowest equal order pair finite volume element discretization is achieved by enriching the velocity space with local functions that do not necessarily vanish on the element boundaries. Finally, some numerical experiments that confirm the predicted behavior of the method are provided.