915 resultados para Uniform Gâteaux Smooth Norms
Resumo:
Although there has been a significant decrease in caries prevalence in developed countries, the slower progression of dental caries requires methods capable of detecting and quantifying lesions at an early stage. The aim of this study was to evaluate the effectiveness of fluorescence-based methods (DIAGNOdent 2095 laser fluorescence device [LF], DIAGNOdent 2190 pen [LFpen], and VistaProof fluorescence camera [FC]) in monitoring the progression of noncavitated caries-like lesions on smooth surfaces. Caries-like lesions were developed in 60 blocks of bovine enamel using a bacterial model of Streptococcus mutans and Lactobacillus acidophilus . Enamel blocks were evaluated by two independent examiners at baseline (phase I), after the first cariogenic challenge (eight days) (phase II), and after the second cariogenic challenge (a further eight days) (phase III) by two independent examiners using the LF, LFpen, and FC. Blocks were submitted to surface microhardness (SMH) and cross-sectional microhardness analyses. The intraclass correlation coefficient for intra- and interexaminer reproducibility ranged from 0.49 (FC) to 0.94 (LF/LFpen). SMH values decreased and fluorescence values increased significantly among the three phases. Higher values for sensitivity, specificity, and area under the receiver operating characteristic curve were observed for FC (phase II) and LFpen (phase III). A significant correlation was found between fluorescence values and SMH in all phases and integrated loss of surface hardness (ΔKHN) in phase III. In conclusion, fluorescence-based methods were effective in monitoring noncavitated caries-like lesions on smooth surfaces, with moderate correlation with SMH, allowing differentiation between sound and demineralized enamel.
Resumo:
BACKGROUND Viral load and CD4% are often not available in resource-limited settings for monitoring children's responses to antiretroviral therapy (ART). We aimed to construct normative curves for weight gain at 6, 12, 18, and 24 months following initiation of ART in children, and to assess the association between poor weight gain and subsequent responses to ART. DESIGN Analysis of data from HIV-infected children younger than 10 years old from African and Asian clinics participating in the International epidemiologic Databases to Evaluate AIDS. METHODS The generalized additive model for location, scale, and shape was used to construct normative percentile curves for weight gain at 6, 12, 18, and 24 months following ART initiation. Cox proportional models were used to assess the association between lower percentiles (< 50th) of weight gain distribution at the different time points and subsequent death, virological suppression, and virological failure. RESULTS Among 7173 children from five regions of the world, 45% were underweight at baseline. Weight gain below the 50th percentile at 6, 12, 18, and 24 months of ART was associated with increased risk of death, independent of baseline characteristics. Poor weight gain was not associated with increased hazards of virological suppression or virological failure. CONCLUSION Monitoring weight gain on ART using age-specific and sex-specific normative curves specifically developed for HIV-infected children on ART is a simple, rapid, sustainable tool that can aid in the identification of children who are at increased risk of death in the first year of ART.
Resumo:
Introduction: In team sports the ability to use peripheral vision is essential to track a number of players and the ball. By using eye-tracking devices it was found that players either use fixations and saccades to process information on the pitch or use smooth pursuit eye movements (SPEM) to keep track of single objects (Schütz, Braun, & Gegenfurtner, 2011). However, it is assumed that peripheral vision can be used best when the gaze is stable while it is unknown whether motion changes can be equally well detected when SPEM are used especially because contrast sensitivity is reduced during SPEM (Schütz, Delipetkose, Braun, Kerzel, & Gegenfurtner, 2007). Therefore, peripheral motion change detection will be examined by contrasting a fixation condition with a SPEM condition. Methods: 13 participants (7 male, 6 female) were presented with a visual display consisting of 15 white and 1 red square. Participants were instructed to follow the red square with their eyes and press a button as soon as a white square begins to move. White square movements occurred either when the red square was still (fixation condition) or moving in a circular manner with 6 °/s (pursuit condition). The to-be-detected white square movements varied in eccentricity (4 °, 8 °, 16 °) and speed (1 °/s, 2 °/s, 4 °/s) while movement time of white squares was constant at 500 ms. 180 events should be detected in total. A Vicon-integrated eye-tracking system and a button press (1000 Hz) was used to control for eye-movements and measure detection rates and response times. Response times (ms) and missed detections (%) were measured as dependent variables and analysed with a 2 (manipulation) x 3 (eccentricity) x 3 (speed) ANOVA with repeated measures on all factors. Results: Significant response time effects were found for manipulation, F(1,12) = 224.31, p < .01, ηp2 = .95, eccentricity, F(2,24) = 56.43; p < .01, ηp2 = .83, and the interaction between the two factors, F(2,24) = 64.43; p < .01, ηp2 = .84. Response times increased as a function of eccentricity for SPEM only and were overall higher than in the fixation condition. Results further showed missed events effects for manipulation, F(1,12) = 37.14; p < .01, ηp2 = .76, eccentricity, F(2,24) = 44.90; p < .01, ηp2 = .79, the interaction between the two factors, F(2,24) = 39.52; p < .01, ηp2 = .77 and the three-way interaction manipulation x eccentricity x speed, F(2,24) = 3.01; p = .03, ηp2 = .20. While less than 2% of events were missed on average in the fixation condition as well as at 4° and 8° eccentricity in the SPEM condition, missed events increased for SPEM at 16 ° eccentricity with significantly more missed events in the 4 °/s speed condition (1 °/s: M = 34.69, SD = 20.52; 2 °/s: M = 33.34, SD = 19.40; 4 °/s: M = 39.67, SD = 19.40). Discussion: It could be shown that using SPEM impairs the ability to detect peripheral motion changes at the far periphery and that fixations not only help to detect these motion changes but also to respond faster. Due to high temporal constraints especially in team sports like soccer or basketball, fast reaction are necessary for successful anticipation and decision making. Thus, it is advised to anchor gaze at a specific location if peripheral changes (e.g. movements of other players) that require a motor response have to be detected. In contrast, SPEM should only be used if a single object, like the ball in cricket or baseball, is necessary for a successful motor response. References: Schütz, A. C., Braun, D. I., & Gegenfurtner, K. R. (2011). Eye movements and perception: A selective review. Journal of Vision, 11, 1-30. Schütz, A. C., Delipetkose, E., Braun, D. I., Kerzel, D., & Gegenfurtner, K. R. (2007). Temporal contrast sensitivity during smooth pursuit eye movements. Journal of Vision, 7, 1-15.
Resumo:
Few studies have investigated causal pathways linking psychosocial factors to each other and to screening mammography. Conflicting hypotheses exist in the theoretic literature regarding the role and importance of subjective norms, a person's perceived social pressure to perform the behavior and his/her motivation to comply. The Theory of Reasoned Action (TRA) hypothesizes that subjective norms directly affect intention; while the Transtheoretical Model (TTM) hypothesizes that attitudes mediate the influence of subjective norms on stage of change. No one has examined which hypothesis best predicts the effect of subjective norms on mammography intention and stage of change. Two statistical methods are available for testing mediation, sequential regression analysis (SRA) and latent variable structural equation modeling (LVSEM); however, software to apply LVSEM to dichotomous variables like intention has only recently become available. No one has compared the methods to determine whether or not they yield similar results for dichotomous variables. ^ Study objectives were to: (1) determine whether the effect of subjective norms on mammography intention and stage of change are mediated by pros and cons; and (2) compare mediation results from the SRA and LVSEM approaches when the outcome is dichotomous. We conducted a secondary analysis of data from a national sample of women veterans enrolled in Project H.O.M.E. (H&barbelow;ealthy O&barbelow;utlook on the M&barbelow;ammography E&barbelow;xperience), a behavioral intervention trial. ^ Results showed that the TTM model described the causal pathways better than the TRA one; however, we found support for only one of the TTM causal mechanisms. Cons was the sole mediator. The mediated effect of subjective norms on intention and stage of change by cons was very small. These findings suggest that interventionists focus their efforts on reducing negative attitudes toward mammography when resources are limited. ^ Both the SRA and LVSEM methods provided evidence for complete mediation, and the direction, magnitude, and standard errors of the parameter estimates were very similar. Because SRA parameter estimates were not biased toward the null, we can probably assume negligible measurement error in the independent and mediator variables. Simulation studies are needed to further our understanding of how these two methods perform under different data conditions. ^
Resumo:
Thoracic Aortic Aneurysms and Dissections (TAAD) are the fifteenth leading cause of death in the United States. About 15% of TAAD patients have family history of the disease. The most commonly mutated gene in these families is ACTA2, encoding smooth muscle-specific α-actin. ACTA2 missense mutations predispose individuals both to TAAD and to vascular occlusive disease of small, muscular arteries. Mice carrying an Acta2 R258C mutant transgene with a wildtype Acta2 promoter were generated and bred with Acta2-/- mice to decrease the wildtype: mutant Acta2 ratio. Acta2+/+ R258C TGmice have decreased aortic contractility without aortic disease. Acta2+/- R258C TG mice, however, have significant aortic dilatations by 12 weeks of age and a hyperproliferative response to injury. We characterized smooth muscle cells (SMCs) from bothmouse models under the hypothesis that mutant α-actin has a dominant negative effect, leading to impaired contractile filament formation/stability, improper focal adhesion maturation and increased proliferation. Explanted aortic SMCs from Acta2+/+ R258C TG mice are differentiated - they form intact filaments, express higher levels of contractile markers compared to wildtype SMCs and have predominantly nuclear Myocardin-Related Transcription Factor A (MRTF-A) localization. However, ultracentrifugation assays showed large unpolymerized actin fractions, suggesting that the filaments are brittle. In contrast, Acta2+/- R258C TG SMCs are less well-differentiated, with pools of unpolymerized actin, more cytoplasmic MRTF-A and decreased contractile protein expression compared to wildtype cells. Ultracentrifugation assays after treating Acta2+/- R258C TGSMCs with phalloidin showed actin filament fractions, indicating that mutant α-actin can polymerize into filaments. Both Acta2+/+ R258C TGand Acta2+/- R258C TGSMCs have larger and more peripheral focal adhesions compared to wildtype SMCs. Rac1 was more activated in Acta2+/+ R258C TGSMCs; both Rac1 and RhoA were less activated in Acta2+/- R258C TG SMCs, and FAK was more activated in both transgenic SMC lines compared to wildtype. Proliferation in both cell lines was significantly increased compared to wildtype cells and could be partially attenuated by inhibition of FAK or PDGFRβ. These data support a dominant negative effect of the Acta2 R258C mutation on the SMC phenotype, with increasing phenotypic severity when wildtype: mutant α-actin levels are decreased.
Resumo:
CIPWFULL is a user-friendly, stand-alone FORTRAN software program that is designed to calculate the comprehensive CIPW normative mineral composition of igneous rocks and strictly adheres to the original formulation of the CIPW protocol. This faithful adherence alleviates inaccuracies in normative mineral calculations by programs commonly used by petrologists. Additionally, several of the most important petrological and mineralogical parameters of igneous rocks are calculated by the program. Along with all the regular major oxide elements, all the significant minor elements whose contents can potentially effect the CIPW normative mineral composition are included. CIPWFULL also calculates oxidation ratios for igneous rock samples that have only one oxidation state of iron reported in the specimen analysis. It also provides an option for normalization of analyses to unity on a hydrous-free basis in order to facilitate comparison of norms among rock groups. Other capabilities of the program cater for rare situations, like the presence of cancrinite or exclusion from the norm calculation of rare rocks like carbonatite. Several mineralogical, petrological and discriminatory parameters and indexes are additionally calculated by the CIPWFULL program. The CIPWFULL program is very efficient and flexible and allows for a user-defined free-format input of all the chemical species, and it permits feeding of minor elements as parts per million or oxide percentages. Results of calculations are printed in a formatted ASCII text file and may be optionally casted into a space-delimited text files that are ready to be imported to general spreadsheet programs. CIPWFULL is DOS-based and is implemented on WINDOWS and mainframe platforms.
Resumo:
We present ice thickness and bed topography maps with a high spatial resolution (250-500 m) of a land-terminating section of the Greenland Ice Sheet derived from ground-based and airborne radar surveys. The data have a total area of ~12 000 km^2 and cover the whole ablation area of the outlet glaciers of Isunnguata Sermia, Russell, Leverett, Ørkendalen and Isorlersuup up to the long-term mass balance equilibrium line altitude at ~1600 m above sea level. The bed topography shows highly variable subglacial trough systems, and the trough of Isunnguata Sermia Glacier is overdeepened and reaches an elevation of ~500 m below sea level. The ice surface is smooth and only reflects the bedrock topography in a subtle way, resulting in a highly variable ice thickness. The southern part of our study area consists of higher bed elevations compared to the northern part. The compiled data sets of ground-based and airborne radar surveys cover one of the most studied regions of the Greenland Ice Sheet and can be valuable for detailed studies of ice sheet dynamics and hydrology.
Resumo:
On Leg 85, 16 holes were cored at five sites. Thirteen of the holes were cored with the hydraulic piston corer (HPC) or the variable-length hydraulic piston corer (VLHPC) or both; the remainder were rotary drilled. Partially duplicating stratigraphic sections were successfully recovered by hydraulic piston coring at Sites 572 to 575. Sub-bottom penetration was deepest (about 210 m) at HPC Hole 575A, which bottomed in lower Miocene sediments. Penetration by hydraulic piston coring was limited at all sites not by the failure of the corer to stroke out but by the excessive force (overpull) necessary to retrieve the core barrel from the hole. The sediments recovered are relatively uniform siliceous-calcareous oozes to calcareous ooze-chalks. Paleomagnetic measurements were made at all stratigraphic levels, but magnetostratigraphic sequences could be resolved only for the Pleistocene-Pliocene and for brief upper, middle, and lower Miocene sections. In the younger and less consolidated sediments, the declination often shows large-scale azimuthal rotations downcore. These smooth trends vary from core to core, indicating either rotation between the sediment and the core liner or the rotation of the core barrel during the coring or retrieval process. Thus, azimuthal orientation of the samples was impossible even though a Kuster azimuthal orientation tool was used during the hydraulic piston coring. At all sites, the downhole shift from mainly siliceous to mainly calcareous ooze-chalk coincided with a decrease in NRM intensity of at least one order of magnitude, to 1.0*10**-8 G. Diagenesis is the probable reason for this behavior, although the dilution of magnetic carriers as the result of higher accumulation rates may also be a factor. A tectonic analysis using data from samples with stable remanence indicates a northward plate motion of about 0.3 deg/m.y. during the last 18 m.y., a rate that agrees with most previous reconstructions of Pacific Plate motion.