974 resultados para Ultrafine Particles, Laser Printer, Indoor Air Quality, Aerosol Formation
Resumo:
The impact of mycotoxins on human and animal health is well recognized. Aflatoxin B1 (AFB1) is by far the most prevalent and the most potent natural carcinogen and is usually the major aflatoxin produced by toxigenic fungal strains. Data available, points to an increasing frequency of poultry feed contamination by aflatoxins. Since aflatoxin residues may accumulate in body tissues, this represents a high risk to human health. Samples from commercial poultry birds have already presented detectable levels of aflatoxin in liver. A descriptive study was developed in order to assess fungal contamination by species from Aspergillus flavus complex in seven Portuguese poultry units. Air fungal contamination was studied by conventional and molecular methods. Air, litter and surfaces samples were collected. To apply molecular methods, air samples of 300L were collected using the Coriolis μ air sampler (Bertin Technologies), at 300 L/min airflow rate. For conventional methodologies, all the collected samples were incubated at 27ºC for five to seven days. Through conventional methods, Aspergillus flavus was the third fungal species (7%) most frequently found in 27 indoor air samples analysed and the most commonly isolated species (75%) in air samples containing only the Aspergillus genus...
Resumo:
OBJECTIVE: To analyze the impact of intra-urban atmospheric conditions on circulatory and respiratory diseases in elder adults. METHODS: Cross-sectional study based on data from 33,212 hospital admissions in adults over 60 years in the city of São Paulo, southeastern Brazil, from 2003 to 2007. The association between atmospheric variables from Congonhas airport and bioclimatic index, Physiological Equivalent Temperature, was analyzed according to the district's socioenvironmental profile. Descriptive statistical analysis and regression models were used. RESULTS: There was an increase in hospital admissions due to circulatory diseases as average and lowest temperatures decreased. The likelihood of being admitted to the hospital increased by 12% with 1ºC decrease in the bioclimatic index and with 1ºC increase in the highest temperatures in the group with lower socioenvironmental conditions. The risk of admission due to respiratory diseases increased with inadequate air quality in districts with higher socioenvironmental conditions. CONCLUSIONS: The associations between morbidity and climate variables and the comfort index varied in different groups and diseases. Lower and higher temperatures increased the risk of hospital admission in the elderly. Districts with lower socioenvironmental conditions showed greater adverse health impacts.
Resumo:
Dissertation submitted in partial fulfilment of the requirements for the Degree of Master of Science in Geospatial Technologies
Resumo:
Aims: The main aims of this work were the study of cork slabs moulds colonization and the evaluation of the moulds diversity during cork processing steps, in different cork stoppers factories. Simultaneously, it was envisaged to perform an evaluation of the air quality. Methods and Results: Moulds were isolated and identified from cork slabs and cork samples in four cork stoppers factories. The identification was based on morphological characters and microscopic observation of the reproductive structures. Airborne spore dispersion was assessed using a two stage Andersen sampler. It was observed that Chrysonilia sitophila was always present on cork slabs during the maturing period, but mould diversity appeared to be associated to the different factory configurations and processing steps. Conclusions: Spatial separation of the different steps of the process, including physical separation of the maturation step, is essential to guarantee high air quality and appropriate cork slabs colonization, i.e. C. sitophila dominance. The sorting and cutting of the edges of cork slabs after boiling and before the maturing step is also recommended. Significance and Impact of the Study: This study is very important for the cork stopper industry as it gives clear indications on how to keep high quality manufacturing standards and how to avoid occupational health problems.
Resumo:
Aims: The main aims of this work were the study of cork slabs moulds colonization and the evaluation of the moulds diversity during cork processing steps, in different cork stoppers factories. Simultaneously, it was envisaged to perform an evaluation of the air quality. Methods and Results: Moulds were isolated and identified from cork slabs and cork samples in four cork stoppers factories. The identification was based on morphological characters and microscopic observation of the reproductive structures. Airborne spore dispersion was assessed using a two stage Andersen sampler. It was observed that Chrysonilia sitophila was always present on cork slabs during the maturing period, but mould diversity appeared to be associated to the different factory configurations and processing steps. Conclusions: Spatial separation of the different steps of the process, including physical separation of the maturation step, is essential to guarantee high air quality and appropriate cork slabs colonization, i.e. C. sitophila dominance. The sorting and cutting of the edges of cork slabs after boiling and before the maturing step is also recommended. Significance and Impact of the Study: This study is very important for the cork stopper industry as it gives clear indications on how to keep high quality manufacturing standards and how to avoid occupational health problems.
Resumo:
Dissertação apresentada como requisito parcial para obtenção do grau de Mestre em Ciência e Sistemas de Informação Geográfica
Resumo:
This paper describes the methodology adopted to assess local air quality impact in the vicinity of a coal power plant located in the south of Portugal. Two sampling areas were selected to assess the deposition flux of dust fallout and its potential spatial heterogeneity. The sampling area was divided into two subareas: the inner, with higher sampling density and urban and suburban characteristics, inside a 6-km circle centered on the stacks, and an outer subarea, mainly rural, with lower sampling density within a radius of 20 km. Particulate matter deposition was studied in the vicinity of the coal fired power plant during three seasonal sampling campaigns. For the first one, the average annual flux of dust fallout was 22.51 g/(m2 yr), ranging from 4.20 to 65.94 g/(m2 yr); for the second one was 9.47 g/(m2 yr), ranging from 0.78 to 32.72 g/(m2 yr) and for the last one was 38.42 g/(m2 yr), ranging from 1.41 to 117.48 g/(m2 yr). The fallout during the second campaign turned out to be much lower than for others. This was in part due to meteorological local patterns but mostly due to the fact that the power plant was not working at full power during the second sampling campaign.155
Resumo:
Environmental management is a complex task. The amount and heterogeneity of the data needed for an environmental decision making tool is overwhelming without adequate database systems and innovative methodologies. As far as data management, data interaction and data processing is concerned we here propose the use of a Geographical Information System (GIS) whilst for the decision making we suggest a Multi-Agent System (MAS) architecture. With the adoption of a GIS we hope to provide a complementary coexistence between heterogeneous data sets, a correct data structure, a good storage capacity and a friendly user’s interface. By choosing a distributed architecture such as a Multi-Agent System, where each agent is a semi-autonomous Expert System with the necessary skills to cooperate with the others in order to solve a given task, we hope to ensure a dynamic problem decomposition and to achieve a better performance compared with standard monolithical architectures. Finally, and in view of the partial, imprecise, and ever changing character of information available for decision making, Belief Revision capabilities are added to the system. Our aim is to present and discuss an intelligent environmental management system capable of suggesting the more appropriate land-use actions based on the existing spatial and non-spatial constraints.
Resumo:
A eficiência energética e a preocupação com a sustentabilidade têm vindo a ganhar preponderância na sociedade moderna. Este trabalho é uma contribuição para esta tendência onde se pretendeu avaliar e sugerir alterações ao sistema de climatização do edifício Biorama do Parque Biológico de Vila Nova de Gaia (PBG). Procedeu-se em primeiro lugar a uma caracterização física, química e geográfica dos 5 biomas constituintes do Biorama. Para isso, recorreu-se a documentos fornecidos pelo próprio PBG, visitas ao local e registo de medições de alguns parâmetros (temperatura, humidade relativa, qualidade do ar). Posteriormente foi realizado o balanço térmico dos edifícios, de acordo com a legislação em vigor, recorrendo a expressões e conceitos teóricos. Foram determinados valores dos ganhos térmicos de aquecimento de 15811, 10694, 7939, 9233, e 6621 kWh/ano para Floresta tropical, Mesozoico, Dunas, Savana e Deserto, respetivamente. Foram igualmente determinados valores dos ganhos térmicos no verão de 7093, 4798, 3560, 4144 e 2971 kWh na Floresta tropical, no Mesozoico, nas Dunas, na Savana e no Deserto, respetivamente. As cargas térmicas de aquecimento foram 149, 125, 47, 60 e 51 kW na Floresta tropical, no Mesozoico, nas Dunas, na Savana e no Deserto, respetivamente. As cargas térmicas de arrefecimento foram iguais a 59, 57, 47, 35 e 36 kW na Floresta tropical, no Mesozoico, nas Dunas, na Savana e no Deserto, respetivamente. Algumas soluções são avançadas, bem como alternativas comportamentais de modo a corrigir alguns problemas identificados. Uma proposta é a da instalação de painéis solares e acumuladores de calor, com os quais se estima um ganho médio conjunto de 500 W em cada bioma, e representam um investimento de 1050 euros e terão um retorno de 1 ano. Em relação à humidade é sugerido a utilização mais eficaz dos aspersores existentes e a utilização de esponjas, para fazer subir a humidade relativa para valores superiores a 80%. Em sentido inverso, no inverno, propõem-se a utilização de material higroscópico para fazer baixar a humidade relativa em cerca de 5%. Os custos com os suportes e o material higroscópico rondam os 250 €. Por fim, é sugerido a instalação de um aparelho de ar condicionado de 16 000 BTU no corredor de ligação, pois é a única forma de garantir condições de conforto térmico. Esta proposta de arrefecimento com ar condicionado e ainda o recurso a uma cortina de lâminas de plástico, que servem para efetuar uma separação mais eficiente entre ar frio e ar quente, têm um custo aproximado de 350 €. É ainda sugerida a utilização de lonas ou de uma planta trepadeira com um custo por planta de 5€, nas coberturas dos telhados virados a sul, sendo que a zona do corredor deverá ser totalmente coberta, a fim de evitar a exposição solar direta.
Resumo:
This work aims to characterize levels and phase distribution of polycyclic aromatic hydrocarbons (PAHs) in indoor air of preschool environment and to assess the impact of outdoor PAH emissions to indoor environment. Gaseous and particulate (PM1 and PM2.5) PAHs (16 USEPA priority pollutants, plus dibenzo[a,l]pyrene, and benzo[j]fluoranthene) were concurrently sampled indoors and outdoors in one urban preschool located in north of Portugal for 35 days. The total concentration of 18 PAHs (ΣPAHs) in indoor air ranged from 19.5 to 82.0 ng/m3; gaseous compounds (range of 14.1–66.1 ng/m3) accounted for 85% ΣPAHs. Particulate PAHs (range 0.7–15.9 ng/m3) were predominantly associated with PM1 (76% particulate ΣPAHs) with 5-ring PAHs being the most abundant. Mean indoor/outdoor ratios (I/O) of individual PAHs indicated that outdoor emissions significantly contributed to PAH indoors; emissions from motor vehicles and fuel burning were the major sources.
Resumo:
Nos últimos anos tem-se assistido à introdução de novos dispositivos de medição da poluição do ar baseados na utilização de sensores de baixo custo. A utilização menos complexa destes sistemas, possibilita a obtenção de dados com elevada resolução temporal e espacial, abrindo novas oportunidades para diferentes metodologias de estudos de monitorização da poluição do ar. Apesar de apresentarem capacidades analíticas distantes dos métodos de referência, a utilização destes sensores tem sido sugerida e incentivada pela União Europeia no âmbito das medições indicativas previstas na Diretiva 2008/50/CE, com uma incerteza expandida máxima de 25%. O trabalho desenvolvido no âmbito da disciplina de Projeto consistiu na escolha, caracterização e utilização em medições reais de um sensor de qualidade do ar, integrado num equipamento protótipo desenvolvido com esse fim, visando obtenção uma estimativa da incerteza de medição associada à utilização deste dispositivo através da aplicação da metodologia de demonstração de equivalência de métodos de medição de qualidade do ar definida pela União Europeia. A pesquisa bibliográfica realizada permitiu constatar que o monóxido de carbono é neste momento o parâmetro de qualidade do ar que permite ser medido de forma mais exata através da utilização de sensores, nomeadamente o sensor eletroquímico da marca Alphasense, modelo COB4, amplamente utilizado em projetos de desenvolvimento neste cotexto de monitorização ambiental. O sensor foi integrado num sistema de medição com o objetivo de poder ser utlizado em condições de autonomia de fornecimento de energia elétrica, aquisição interna dos dados, tendo em consideração ser o mais pequeno possível e de baixo custo. Foi utlizado um sistema baseado na placa Arduino Uno com gravação de dados em cartão de memória SD, baterias e painel solar, permitindo para além do registo das tensões elétricas do sensor, a obtenção dos valores de temperatura, humidade relativa e pressão atmosférica, com um custo global a rondar os 300 euros. Numa primeira fase foram executados um conjunto de testes laboratoriais que permitiram a determinação de várias características de desempenho em dois sensores iguais: tempo de resposta, a equação modelo do sensor, avaliação da repetibilidade, desvio de curto e longo termo, interferência da temperatura e histerese. Os resultados demonstraram um comportamento dos sensores muito linear, com um tempo de resposta inferior a um minuto e com uma equação modelo do sensor dependente da variação da temperatura. A estimativa da incerteza expandida laboratorial ficou, para ambos os sensores, abaixo dos 10%. Após a realização de duas campanhas reais de medição de CO em que os valores foram muito baixos, foi realizada uma campanha de quinze dias num parque de estacionamento subterrâneo que permitiu a obtenção de concentrações suficientemente elevadas e a comparação dos resultados dos sensores com o método de referência em toda a gama de medição (0 a 12 mol.mol-1). Os valores de concentração obtidos pelos dois sensores demonstraram uma excelente correlação com o método de referência (r2≥0,998), obtendo-se resultados para a estimativa da incerteza expandida de campo inferiores aos obtidos para a incerteza laboratorial, cumprindo o objetivo de qualidade de dados definido para as medições indicativas de incerteza expandida máxima de 25%. Os resultados observados durante o trabalho realizado permitiram confirmar o bom desempenho que este tipo de sensor pode ter no âmbito de medições de poluição do ar com um caracter mais indicativo.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Dissertação apresentada para obtenção do Grau de Doutor em Engenharia do Ambiente, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Economics from the NOVA – School of Business and Economics
Resumo:
RESUMO - A legionella em meio hospitalar tem sido alvo de preocupação e de várias discussões, sendo esta uma bactéria patogénica que coloniza vários tipos de ambientes aquáticos (naturais e artificiais). Estas bactérias têm a particularidade de se desenvolver em meio aquático mas a infeção apenas é transmitida através de aerossóis de água contaminada, ou seja, por via aérea. Não se transmitindo de pessoa para pessoa. Pelas suas características os sistemas de arrefecimento de ar, nomeadamente as torres de arrefecimento, condensadores evaporativos, humidificadores e sistemas de ar condicionado, são fontes importantes de disseminação da legionella. Assim surge a necessidade da existência de programas de prevenção, que deverão ter em conta uma adequada manutenção, limpeza e desinfeção. Dada a quantidade de frequentadores assim como da especificidade dos mesmos, em meio hospitalar é particularmente importante a eficácia destes sistemas. Ou seja, os sistemas de arrefecimento em hospitais devem, para além de garantir o conforto térmico, ser responsáveis por manter a qualidade do ar e reduzir os riscos existentes a ele associados. O presente estudo pretende conhecer a verdadeira eficácia dos programas de manutenção e vigilância da Legionella, apenas nos sistemas de arrefecimento. Trata-se então de um estudo exploratório, descritivo recolha desta informação in-loco dos sistemas em estudo, de X hospitais da cidade de Lisboa. Na metodologia serão utilizadas grelhas de observação e resultados de colheita de água dos locais de maior risco. A realização deste estudo visa obter um retrato do panorama existente e contribuir para o início de novos estudos epidemiológicos.