1000 resultados para Ultra-sonografia doppler em cores


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultra-rapid opioid detoxification (UROD) involves the acceleration of opioid withdrawal hv administering thp opioid receptor antagonist naltrexone under general anaesthesia. There is evidence from uncontrolled and a few controlled studies that UROD accelerates opioid withdrawal and that it achieves high rates of completion of acute opioid withdrawal. However, there is clear evidence that the use of a general anaesthetic is not required to accelerate withdrawal or to achieve high rates of completion of acute opioid withdrawal. These goals can be achieved by using naltrexone or naloxone to accelerate withdrawal under light sedation, a procedure known as rapid opioid detoxification under sedation (ROD). There is also evidence that use of an opioid antagonist is not required to achieve a high rate of completion of acute opioid withdrawal. The mixed agonist-antagonist buprenorphine has achieved comparable rates of completion in similarly selected patients with fewer withdrawal symptoms. There is no evidence from controlled trials that either UROD or ROD increases the rate of abstinence from opioids 6 or 12 months after withdrawal. UROD and ROD may increase the number of patients who are inducted onto naltrexone maintenance (NM) therapy but extensive experience with NM therapy suggests that it only has a limited role in selected patients. Given the lack of evidence of substantially increased rates of abstinence, and the need for anaesthetists and high dependency beds, UROD has at best a very minor role in the treatment of a handful of opioid dependent patients who are unable to complete withdraw in any other way. ROD may have more of a role as one option for opioid withdrawal in well motivated patients who want to be rapidly inducted onto NM therapy or who want to enter other types of abstinence-oriented treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have used the 2dF spectrograph on the Anglo-Australian Telescope to obtain a complete spectroscopic sample of all objects in the magnitude range, 16.5 < bj < 19.8, regardless of morphology, in an area centred on the Fornax Cluster of galaxies. Among the unresolved targets are five objects which are members of the Fornax Cluster. They are extremely compact stellar systems with scale lengths less than 40 parsecs. These ultra-compact dwarfs are unlike any known type of stellar system, being more compact and significantly less luminous than other compact dwarf galaxies, yet much brighter than any globular cluster.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the impact of systematic use of intraoperative Doppler ultrasound during microsurgical subinguinal varicocele repair. Design: Prospective clinical study. Setting: Andrology laboratory and male infertility section of the urology department of a tertiary care hospital. Patient(s): Two hundred and thirteen men with clinical varicocele. Intervention(s): Subinguinal microsurgical varicocele ligation using an intraoperative vascular Doppler flow detector. Main Outcome Measure(s): Number of veins ligated, lymphatic spared, arteries identified or accidentally ligated. Result(s): A statistically significant greater number of arteries were identified and preserved when intraoperative vascular Doppler was used. In addition, the average number of internal spermatic veins ligated was statistically significantly greater in the same group. Accidental artery ligation occurred in two cases (1.1%) in which the Doppler was not applied. There was no statistically significant difference in number of lymphatics spared between groups. Conclusion(s): Our findings showed that concomitant use of intraoperative vascular Doppler during microsurgical varicocelectomy allows more arterial branches to be preserved, and more internal spermatic veins are likely to be ligated. This device should be considered an attractive tool to improve surgical outcomes and safety. (Fertil Steril (R) 2010; 93: 2396-9. (C)2010 by American Society for Reproductive Medicine.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The aim of this study was to determine the correlation between ductus venosus (DV) Doppler velocimetry and fetal cardiac troponin T (cTnT). Study design: Between March 2007 and March 2008, 89 high-risk pregnancies were prospectively studied. All patients delivered by cesarean section and the Doppler exams were performed on the same day. Multiple regression included the following variables: maternial age, parity, hypertension, diabetes, gestational age at delivery, umbilical artery (UA) S/D ratio, diagnosis of absent or reversed end-diastolic flow velocity (AREDV) in the UA, middle cerebral artery (MCA) pulsatility index (131), and DV pulsatility index for veins (PIV). Immediately after delivery, UA blood samples were obtained for the measurement of pH and cTnT levels. Statistical analysis included the Kruskal-Wallis test and multiple regressions. Results: The results showed a cTnT concentration at birth >0.05 ng/ml in nine (81.8%) of AREDV cases, a proportion significantly higher than that observed in normal UA S/D ratio and UA S/D ratio >p95 with positive diastolic blood flow (7.7 and 23.1%, respectively, p < 0.001). A positive correlation Was found between abnormal DV-PIV and elevated cTnT levels in the UA. Multiple regression identified DV-PIV and a diagnosis of AREDV as independent factors associated with abnormal fetal cTnT levels (p < 0.0001, F(2.86) = 63.5, R = 0.7722). Conclusion: DV-PIV was significantly correlated with fetal cTnT concentrations at delivery. AREDV and abnormal DV flow represent severe cardiac compromise, with increased systemic venous pressure, and a rise in right ventricular afterload, demonstrated by myocardial damage and elevated fetal cTnT. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Understanding the role of multiple colour signals during sexual signalling is a central theme in animal communication. We quantified the role of multiple colour signals (including ultraviolet, UV), measures of body size and testosterone levels in settling disputes between male rivals in an elaborately ornamented, African lizard, played out in a large 'tournament' in the wild. The hue and brightness (total reflectance) of the UV throat in Augrabies flat lizards, Platysaurus broadleyi, as well as body size, were consistent and strong predictors of 'fighting ability'. Males with high fighting ability were larger and displayed a UV throat with low total reflectance. In contrast, males with low fighting ability were smaller and had violet throats with broader spectral reflectance curves (higher total reflectance). As fighting ability is associated with alternative reproductive tactics in this system (territorial versus floater), we also examined the role of colour signals in predicting male reproductive tactic. Territorial males had UV throats with higher chroma but had poorer body condition than floater males, probably because of the energetic costs of maintaining a territory. Although testosterone was not a significant predictor of fighting ability or reproductive tactic, it was correlated with the hue of the UV throat, suggesting that testosterone may impose some constraint on signal expression. Lastly, we show that within the context of the natural signalling environment, UV-reflective throats constitute a conspicuous, effective signal that male Augrabies flat lizards use to advertise their status honestly to rivals. (c) 2006 The Association for the Study of Animal Behaviour. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine reference values for tissue Doppler imaging (TDI) and pulsed Doppler echocardiography for left ventricular diastolic function analysis in a healthy Brazilian adult population. Observations were based on a randomly selected healthy population from the city of Vitoria, Espirito Santo, Brazil. Healthy volunteers (n = 275, 61.7% women) without prior histories of cardiovascular disease underwent transthoracic echocardiography. We analyzed 175 individuals by TDI and evaluated mitral annulus E`- and A`-waves from the septum (S) and lateral wall (L) to calculate E`/A` ratios. Using pulsed Doppler echocardiography, we further analyzed the mitral E- and A-waves, E/A ratios, isovolumetric relaxation times (IRTs), and deceleration times (DTs) of 275 individuals. Pulsed Doppler mitral inflow mean values for men were as follows: E-wave: 71 +/- 16 cm/sec, A-wave: 68 +/- 15 cm/sec, IRT: 74.8 +/- 9.2 ms, DT: 206 +/- 32.3 ms, E/A ratio: 1.1 +/- 0.3. Pulsed Doppler mitral inflow mean values for women were as follows: E-wave: 76 +/- 17, A-wave: 69 +/- 14 cm/sec, IRT: 71.2 +/- 10.5 ms, DT: 197 +/- 33.3 ms, E/A ratio: 1.1 +/- 0.3. IRT and DT values were higher in men than in women (P = 0.04 and P = 0.007, respectively). TDI values in men were as follows: E`S: 11 +/- 3 cm/sec, A`S: 13 +/- 2 cm/sec, E`S/A`S: 0.89 +/- 0.2, E`L: 14 +/- 3 cm/sec, A`L: 14 +/- 2 cm/sec, E`L/A`L: 1.1 +/- 0.4. E-wave/ E`S ratio: 6.9 +/- 2.2; E-wave / E`L ratio: 4.9 +/- 1.7. In this study, we determined pulsed Doppler and TDI derived parameters for left ventricular diastolic function in a large sample of healthy Brazilian adults. (Echocardiography 2010;27:777-782).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Accurate diagnosis of portal vein (PV) stenosis by real-time and color Doppler US (CD-US) after segmental liver transplantation in children can decrease morbidity by avoiding unnecessary biopsy, PV hypertension, thrombosis and loss of the graft. Objective To evaluate CD-US parameters for the prediction of PV stenosis after segmental liver transplantation in children. Materials and methods We retrospectively reviewed 61 CD-US examinations measuring the diameter at the PV anastomosis, velocities at the anastomosis (PV1) and in the segment proximal to the anastomosis (PV2), and the PV1/PV2 velocity ratio. The study group comprised patients with stenosis confirmed by angiography and the control group comprised patients with a good clinical outcome. Results PV stenosis was seen in 12 CD-US examinations. The mean PV diameter was smaller in the study group (2.6 mm versus 5.7 mm) and a PV diameter of < 3.5 mm was highly predictive of stenosis (sensitivity 100%, specificity 91.8%). Conclusion A PV diameter of < 3.5 mm is a highly predictive CD-US parameter for the detection of hemodynamically significant stenosis on angiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dysplasia and esophageal adenocarcinoma may arise in patients with Barrett`s esophagus after fundoplication esophageal pH monitoring showing no acid in esophagus. This suggests the need to develop methodology to evaluate the occurrence of ultra-distal reflux (1 cm above the LES). The objective of the study was to compare acid exposition in three different levels: 5 cm above the upper border of the LES, 1 cm above the LES and in the intrasphincteric region. Eleven patients with Barrett`s esophagus after Nissen fundoplication with no clinical, endoscopic and radiologic evidence of reflux were selected. Four-channel pH monitoring took place: channel A, 5 cm above the upper border of the LES; channel B, 1 cm above the LES; channel C, intrasphincteric; channel D, intragastric. The results of channels A, B and C were compared. There was significant increase in number of reflux episodes and a higher fraction of time with pH <4.0 in channel B compared to channel A. There was significant decrease in fraction of time with pH <4.0 in channel B compared to channel C. Two cases of esophageal adenocarcinoma were diagnosed in the studied patients. The region 1 cm above the upper border of the LES is more exposed to acid than the region 5 cm above the upper border of the LES, although this exposure occurred in reduced levels. The region 1 cm above the upper border of the LES is less exposed to acid than the intrasphincteric region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare color Doppler imaging (CDI) parameters of the superior ophthalmic vein (SOV) in patients with Graves` orbitopathy (GO) and in normal controls. Forty-three GO patients and 14 normal controls underwent CDI of the SOV. Patients had either fibrotic (lipogenic or myogenic) or congestive orbitopathy. The findings for each group were compared. Fifty-eight orbits with fibrotic orbitopathy, 28 with congestive orbitopathy, and 28 from controls, were studied. In the congestive group, SOV flow was detected in 13, undetectable in 11, and reversed in four orbits; in the fibrotic group, it was present in 41 and undetectable in 17 orbits. In normal controls, SOV flow was detected in 25 and undetectable in three orbits. The differences among the three groups were significant. There was also a significant difference between controls and the congestive GO orbits but not between the fibrotic group and the other two groups. Fibrotic myogenic orbitopathy patients displayed a significantly smaller SOV flow than patients with lipogenic orbitopathy. SOV was significantly reduced in orbits with congestive GO or with myogenic fibrotic GO, but not in orbits with fibrotic lipogenic orbitopathy. SOV congestion may be a contributing pathogenic factor in both congestive and fibrotic myogenic Graves` orbitopathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluate the distribution and variation of placental vascular indices according to gestational age and placental volume. From March to November 2007, three-dimensional (3D)-power Doppler ultrasound was performed in 295 normal pregnancies from 12 to 40 weeks of gestation. Using the same preestablished settings for all patients, power Doppler was applied to the placenta and placental Volume was obtained by the rotational technique (VOCAL(TM)). The 3D-power histogram was used to determine the placental vascular indices: vascularization index (VI), flow index (FI) and vascularization-flow index (VFI). The placental vascular indices were then plotted against gestational age and placental volume. All placental vascular indices showed constant distribution throughout gestation. A tendency for a reduction in placental vascular indices with increased placental volume was observed, but was only statistically significant when placental FI was considered (p < 0.05). All placental vascular indices estimated by 3D-power Doppler ultrasonography presented constant distribution throughout gestation, despite the increase in placental volume according to gestational age. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To correlate Doppler results with hematological indices at birth in small-for-gestational-age (SGA) fetuses. Design. Prospective study. Setting. Tertiary teaching hospital, Sao Paulo, Brazil. Population. One hundred singleton pregnancies with SGA fetuses of > 27 weeks gestational age. Methods. All women had Doppler velocimetry of the umbilical arteries, middle cerebral artery, and ductus venosus within < 72 hours prior to delivery. After birth, umbilical artery blood was collected for hematological analysis. Main outcome measures. The association between fetal Doppler velocimetry pulsatility index (PI) and some hematological indices. Results. Umbilical artery PI showed a positive correlation with nucleated red blood cell count in the umbilical cord (r = 0.46; p<0.01), and a negative correlation with platelet count (r = -0.53; p<0.01) and white blood cell count (r = -0.42; p<0.01). Middle cerebral artery PI was positively correlated with platelet count (r = 0.43; p<0.01) and white blood cell count (r = 0.38; p<0.01), and was negatively correlated with nucleated red blood cell count (r = -0.39; p<0.01). The ductus venosus pulsatility index showed a positive correlation with nucleated red blood cell count (r = 0.36; p<0.01), and a negative correlation with platelet count (r = -0.37; p<0.01) and white blood cell count (r = -0.26; p<0.01). Conclusion. A significant positive or negative correlation between nucleated red blood cell, platelet and white blood cell counts, and Doppler indices suggests an association between placental insufficiency and the fetal hematological response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the relationship between ductus venosus Doppler findings on the day of delivery and postnatal outcomes in pregnancies with absent or reversed end-diastolic (ARED) flow in the umbilical arteries. Study design: Postnatal outcomes of 103 newborns of pregnancies with a diagnosis of ARED flow on Doppler velocimetry of the umbilical arteries were analyzed retrospectively between January 1997 and December 2004. Single pregnancies and fetuses without malformations were included. The cases were divided into two groups according to the flow during atrial contraction (a-wave) in the ductus venosus on the day of delivery: group A, 20 cases with absent or reversed flow in the ductus venosus and group B, 83 cases with positive flow. The results were analyzed statistically using the chi-square test, Fisher`s exact test and the Mann-Whitney U test with the level of significance set at 5%. Results: All newborns were delivered by cesarean section. Gestational age was similar in the two groups (group A: 30 weeks and group B: 30.9 weeks, P = 0.23). Absent or reversed ductus venosus flow was associated with the following adverse postnatal outcomes: lower birthweight (P < 0.001), lower Apgar scores in the first (P = 0.001) and fifth minute (P = 0.001), a higher frequency of orotracheal intubation (P = 0.001) and pH at birth less than 7.20 (P < 0.001), pulmonary hemorrhage (P = 0.03), thrombocytopenia (P = 0.02), hypoglycemia (P = 0.01), intracranial hemorrhage (P = 0.02), and postnatal death (P = 0.007). Conclusion: The study of ductus venosus flow may provide additional information regarding the best time for interruption of pregnancies with ARED flow in the umbilical arteries characterized by extreme prematurity. (C) 2008 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives/Hypothesis: Blood supply to the Hadad-Bassagasteguy pedicled nasoseptal flap may be interrupted by surgery of the pterygopalatine fossa, posterior septectomy, or large sphenoidotomies. This would preclude its use for reconstruction of skull base defects after expanded endonasal approaches (EEA). We present a novel method to ascertain the patency of the nasoseptal artery after prior surgery, and consequently the availability of the nasoseptal flap, using acoustic Doppler sonography. Study Design: Retrospective clinical review. Methods: Four patients who underwent EEAs were evaluated intraoperatively with acoustic Doppler sonography. The mucosa that covers the inferior aspect of the rostrum of the sphenoid sinus was scanned with the tip of the probe. Reflection of sound waves representing intravascular blood flow was assessed. Results: In three patients, the artery was identified in at least one side. One remaining patient showed no acoustic signal suggesting loss of the nasoseptal artery bilaterally, therefore necessitating the use of a fat graft for the reconstruction. Conclusions: Acoustic Doppler sonography seems to be a feasible and effective way to ascertain the availability of the nasoseptal artery. It is a relatively inexpensive and simple technique that can be performed by any endoscopic surgeon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To determine normal blood flow velocities across the fetal tricuspid valve (TV) at 11-13 weeks and 6 days of gestation and to examine the reproducibility of these measurements. Methods A prospective study involving 166 normal singleton pregnancies examined at 11-13 weeks and 6 days was carried out. Descriptive analysis of E- and A-waves` maximum velocities, E/A ratio, duration of the cardiac cycle (C) and diastole (D) and D/C ratio were calculated. Intraobserver and interobserver agreement analysis was performed in a subgroup of 12 cases. Results Average (+/- SD) flow velocities were: E-wave, 25.0 (+/- 4.6) cm/s; A-wave. 42.9 (+/- 5.9) cm/s; E/A, 0.58 (+/- 0.07); cardiac cycle, 390 (+/- 21.1) ms; diastole, 147 (+/- 18) ms and D/C, 0.38 (+/- 0.04). Significant correlation was observed between all parameters (except A-wave) and gestational age but not with nuchal translucency (NT). Intraclass correlation coefficients (interobserver, intraobsever examiner I and intraobserver examiner 2) were: E-wave, 0.53, 0.53 and 0.64; A-wave, 0.45, 0.46 and 0.49; cardiac cycle, 0.70, 0.79 and 0.84 and diastole, 0.63, 0.85 and 0.82, respectively. Conclusions The present study establishes normal Doppler parameters for blood flow across the TV at 11 - 13 weeks and 6 days and demonstrates that these parameters do not correlate with NT measurement and have good/moderate reproducibility. Copyright (C) 2010 John Wiley & Sons, Ltd.