981 resultados para Ten commandments (Motion picture : 1956)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Imaging during a period of minimal myocardial motion is of paramount importance for coronary MR angiography (MRA). The objective of our study was to evaluate the utility of FREEZE, a custom-built automated tool for the identification of the period of minimal myocardial motion, in both a moving phantom at 1.5 T and 10 healthy adults (nine men, one woman; mean age, 24.9 years; age range, 21-32 years) at 3 T. CONCLUSION: Quantitative analysis of the moving phantom showed that dimension measurements approached those obtained in the static phantom when using FREEZE. In vitro, vessel sharpness, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were significantly improved when coronary MRA was performed during the software-prescribed period of minimal myocardial motion (p < 0.05). Consistent with these objective findings, image quality assessments by consensus review also improved significantly when using the automated prescription of the period of minimal myocardial motion. The use of FREEZE improves image quality of coronary MRA. Simultaneously, operator dependence can be minimized while the ease of use is improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Height of individuals has long been considered as a significant index of nutrition and health of a population; still, there is little information regarding the trends of height and weight among developing or transitional countries. We assessed the secular trends in height and weight in children of the Seychelles, a rapidly developing island state in the Indian Ocean (African region). METHODS: Height and weight were measured in all students of all schools in four selected school grades (kindergarten, 4th, 7th and 10th grades) for the periods 1998-9 (6391 children) and 2005-6 (8582 children). Data for 1956-7 was extracted from a previously published report. RESULTS: At age 15.5 years, boys/girls were on average 10/13 cm taller and 15/9 kg heavier in 2005-6 than in 1956-7. Height increased in boys/girls by 1.62/0.93 cm/decade between 1956-7 and 1998-9 and by 1.14/1.82 cm/decade between 1998-9 and 2005-6. For weight, the linear increase in boys/girls was 1.38/1.10 kg/decade between 1956-7 and 1998-9 and 2.21/2.50 kg/decade between 1998-9 and 2005-6. Overall, the relative increase in weight between 1956-7 and 2005-6 was 5-fold higher than the relative increase in height. CONCLUSION: Height and weight increased markedly over time in children aged <16 years in the Seychelles, consistent with large changes in socio-economic and nutritional indicators in the considered 50-year interval. The markedly steeper increase in weight than height over time is consistent with an epidemic of overweight and obesity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a realistic simulator for the Computed Tomography (CT) scan process for motion analysis. In fact, we are currently developing a new framework to find small motion from the CT scan. In order to prove the fidelity of this framework, or potentially any other algorithm, we present in this paper a simulator to simulate the whole CT acquisition process with a priori known parameters. In other words, it is a digital phantom for the motion analysis that can be used to compare the results of any related algorithm with the ground-truth realistic analytical model. Such a simulator can be used by the community to test different algorithms in the biomedical imaging domain. The most important features of this simulator are its different considerations to simulate the best the real acquisition process and its generality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gait analysis methods to estimate spatiotemporal measures, based on two, three or four gyroscopes attached on lower limbs have been discussed in the literature. The most common approach to reduce the number of sensing units is to simplify the underlying biomechanical gait model. In this study, we propose a novel method based on prediction of movements of thighs from movements of shanks. Datasets from three previous studies were used. Data from the first study (ten healthy subjects and ten with Parkinson's disease) were used to develop and calibrate a system with only two gyroscopes attached on shanks. Data from two other studies (36 subjects with hip replacement, seven subjects with coxarthrosis, and eight control subjects) were used for comparison with the other methods and for assessment of error compared to a motion capture system. Results show that the error of estimation of stride length compared to motion capture with the system with four gyroscopes and our new method based on two gyroscopes was close ( -0.8 ±6.6 versus 3.8 ±6.6 cm). An alternative with three sensing units did not show better results (error: -0.2 ±8.4 cm). Finally, a fourth that also used two units but with a simpler gait model had the highest bias compared to the reference (error: -25.6 ±7.6 cm). We concluded that it is feasible to estimate movements of thighs from movements of shanks to reduce number of needed sensing units from 4 to 2 in context of ambulatory gait analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RAPPORT DE SYNTHESE : BUT : Le but de ce sujet de recherche est d'évaluer le taux de succès et les complications à long terme de la sclérectomie profonde non pénétrante avec implant de collagène (SPIC) chez les patients atteints de glaucome à angle ouvert. METODES ET PATIENTS : Il s'agit d'une étude clinique, prospective, monocentrique, non-randomisée, effectuée sur 105 patients atteints d'un glaucome à angle ouvert médicalement non-contrôlé. Ces patients ont tous bénéficiés d'une SPIC, effectuée selon le geste chirurgicale standard (technique décrite dans l'article). Dans le cadre de cette étude, nous avons effectué un bilan ophtalmologique complet avant l'acte chirurgical puis un suivi postopératoire à 1 et 7 jours ; 1,2,3,6,9,12 mois et ensuite tous les 6 mois durant les dix années suivantes. RESULTATS : Le suivit moyen de cette étude s'étend sur 101.5 ± 43.1, [3-144] mois (moyenne ± écart type, [étendue]). La pression intraoculaire (PIO) préopératoire était élevée à 26.8 ± 7.7, (14-52] mmHg, et l'acuité visuelle corrigée à 0.71 ± 0.33, [0.02-1.5]. Au terme des dix années après le traitement chirurgical, le nombre de patients suivit était de 52 avec une pression intraoculaire abaissée à 12.2 ± 4.7, [6-20] mmHg et une acuité visuelle corrigée de 0.63 ± 0.34, [0.01-1.2]. Le nombre de médicaments par patient a diminué de 2.3 ± 0.7, [ 1-4] à 1.3 ± 1.1, [0-3]. Dix ans après la SPIC, une pression intraoculaire <_ 21 mmHg sans médicaments (succès complet) était obtenue chez 47.7 % des patients et 89 % avec ou sans traitement médicamenteux (succès relatif). Les gestes postopératoires additionnels par gonioponcture ont été effectués sur 61 yeux (59.8%) et les injections sous-conjonctival de 5-fluorouracil ont été pratiquées sur 25 yeux dont 5 incluant un needling. CONCLUSIONS : Le suivit à long terme sur une période de dix ans, démontre que la sclérectomie profonde avec implant de collagène (SPIC) est efficace dans le contrôle de la pression intraoculaire et présente peu de complications postopératoires.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This brochure contains numerous picturesque photos and written descriptions of Iowa with the intent of inviting the film industry to do film production in Iowa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Greene County, Iowa, overlay project, completed in October, 1973, was evaluated in October, 1978, after five years of service and most recently in October, 1983, after ten years of service. The 33 fibrous concrete sections, four CRCP sections, two mesh reinforced and two plain concrete sections with doweled reinforcement were rated relative to each other on a scale of 0 to 100. The rating was conducted by original members of the Project Planning Committee, Iowa DOT, Iowa County, Federal Highway Administration, University of Illinois and industry representatives. In all, there were 23 and 24 representatives who rated the project in 1978 and 1983 respectively. The 23 or 24 values were then averaged to provide a final rating number for each section or variable. All experimental overlay sections had performed quite well in the period from five through 10 years, experiencing only limited additional deterioration. Based upon this relatively good performance through 10 years, the sections will be maintained for further research with another evaluation at 15 years. The 4" thick nonfibrous mesh reinforced continuous reinforced concrete pavement overlay sections provided the best performance in this research project. Another nonfibrous 5" thick bar reinforced overlay section performed almost as well. The best performance of a fibrous reinforced concrete section was obtained with 160 pounds of fiber per cubic yard.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report documents work undertaken in the demonstration of a low-cost Automatic Weight and Classification System (AWACS). An AWACS procurement specification and details of the results of the project are also included. The intent of the project is to support and encourage transferring research knowledge to state and local agencies and manufacturers through field demonstrations. Presently available, Weigh-in-Motion and Classification Systems are typically too expensive to permit the wide deployment necessary to obtain representative vehicle data. Piezo electric technology has been used in the United Kingdom and Europe and is believed to be the basic element in a low-cost AWACS. Low-cost systems have been installed at two sites, one in Portland Cement Concrete (PCC) pavement in Iowa and the other in Asphaltic Cement Concrete (ACC) pavement in Minnesota to provide experience with both types of pavement. The systems provide axle weights, gross vehicle weight, axle spacing, vehicle classification, vehicle speed, vehicle count, and time of arrival. In addition, system self-calibration and a method to predict contact tire pressure is included in the system design. The study has shown that in the PCC pavement, the AWACS is capable of meeting the needs of state and federal highway agencies, producing accuracies comparable to many current commercial WIM devices. This is being achieved at a procurement cost of substantially less than currently available equipment. In the ACC pavement the accuracies were less than those observed in the PCC pavement which is concluded to result from a low pavement rigidity at this site. Further work is needed to assess the AWACS performance at a range of sites in ACC pavements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The velocity of a liquid slug falling in a capillary tube is lower than predicted for Poiseuille flow due to presence of menisci, whose shapes are determined by the complex interplay of capillary, viscous, and gravitational forces. Due to the presence of menisci, a capillary pressure proportional to surface curvature acts on the slug and streamlines are bent close to the interface, resulting in enhanced viscous dissipation at the wedges. To determine the origin of drag-force increase relative to Poiseuille flow, we compute the force resultant acting on the slug by integrating Navier-Stokes equations over the liquid volume. Invoking relationships from differential geometry we demonstrate that the additional drag is due to viscous forces only and that no capillary drag of hydrodynamic origin exists (i.e., due to hydrodynamic deformation of the interface). Requiring that the force resultant is zero, we derive scaling laws for the steady velocity in the limit of small capillary numbers by estimating the leading order viscous dissipation in the different regions of the slug (i.e., the unperturbed Poiseuille-like bulk, the static menisci close to the tube axis and the dynamic regions close to the contact lines). Considering both partial and complete wetting, we find that the relationship between dimensionless velocity and weight is, in general, nonlinear. Whereas the relationship obtained for complete-wetting conditions is found in agreement with the experimental data of Bico and Quere [J. Bico and D. Quere, J. Colloid Interface Sci. 243, 262 (2001)], the scaling law under partial-wetting conditions is validated by numerical simulations performed with the Volume of Fluid method. The simulated steady velocities agree with the behavior predicted by the theoretical scaling laws in presence and in absence of static contact angle hysteresis. The numerical simulations suggest that wedge-flow dissipation alone cannot account for the entire additional drag and that the non-Poiseuille dissipation in the static menisci (not considered in previous studies) has to be considered for large contact angles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Agafant com a premissa l’elevat grau de poblament disseminat de la plana de Vic i la forta interrelació entre els diferents assentaments, el present treball caracteritza l’actual model urbà dispers de la conurbació vigatana (Osona). L’estudi elabora dos mapes, mitjan segle xx i actual (2009), a través d’un Sistema d’Informació Geogràfica (SIG), i interpreta els resultats partint del concepte de ciutat difusa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Image registration has been proposed as an automatic method for recovering cardiac displacement fields from Tagged Magnetic Resonance Imaging (tMRI) sequences. Initially performed as a set of pairwise registrations, these techniques have evolved to the use of 3D+t deformation models, requiring metrics of joint image alignment (JA). However, only linear combinations of cost functions defined with respect to the first frame have been used. In this paper, we have applied k-Nearest Neighbors Graphs (kNNG) estimators of the -entropy (H ) to measure the joint similarity between frames, and to combine the information provided by different cardiac views in an unified metric. Experiments performed on six subjects showed a significantly higher accuracy (p < 0.05) with respect to a standard pairwise alignment (PA) approach in terms of mean positional error and variance with respect to manually placed landmarks. The developed method was used to study strains in patients with myocardial infarction, showing a consistency between strain, infarction location, and coronary occlusion. This paper also presentsan interesting clinical application of graph-based metric estimators, showing their value for solving practical problems found in medical imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In response to an increasing need for ever-shorter personality instruments, Gosling, Rentfrow, and Swann (2003) developed the Ten-Item-Personality Inventory (TIPI), which measures the dimensions of the Five Factor Model (FFM) using 10 items (two for each dimension) and can be administered in about one minute. In two studies and using a multi-judge (self and observer) and multi-instrument design, we develop Spanish (Castilian) and Catalan versions of the TIPI and evaluate them in terms of internal consistency, test-retest reliability, convergent, discriminant, and content validity, as well as self-observer correlations. Test-retest correlations were strong, and convergence with the NEO-PI-R factors was significant. There were also strong correlations between observer ratings and the participants’ self-ratings. Despite some inconsistencies with respect to the Agreeableness scale, the Catalan translation and both translations into Spanish of the original TIPI demonstrated sufficient psychometric properties to warrant use as a Five Factor personality measure when the use of longer instruments is not convenient or possible. Furthermore, as the first translation of a brief standard Big Five Instrument into Catalan, this work should facilitate future research on personality in the Catalan-speaking population.