781 resultados para Surgery, Plastic
Resumo:
Purpose: To evaluate the influence of socioeconomic factors on visual acuity before cataract surgery. ?Methods: The medical case notes of 240 consecutive patients listed for cataract surgery from January 1, 2010, at Grampian University Hospital, Aberdeen, were reviewed retrospectively. Patients with ocular comorbidity were excluded. Demographics, postal codes, and visual acuity were recorded. Scottish Index of Multiple Deprivation was used to determine the deprivation rank. Home location was classified as urban or rural. The effect of these parameters on preoperative visual acuity was investigated using chi-square tests or Fisher exact test as appropriate. ?Results: A total of 184 patients (mean 75 years) were included. A total of 127 (69%) patients had visual acuity of 6/12 or better. An association was found between affluence and preoperative visual acuity of 6/12 or better (?2trend = 4.97, p = 0.03), with a significant rising trend across quintile of deprivation. There was no evidence to suggest association between geographical region and preoperative visual acuity (p = 0.63). ?Conclusion: Affluence was associated with good visual acuity (6/12 or better) before cataract surgery. There was no difference in preoperative visual acuity between rural and urban populations.
Resumo:
Plastic wastes, and particularly plastic bags and sachets, are a major concern for urban and rural environment in African countries. In the last years some actions have been started for the plastic recycling like the artisanal production of paving blocks with melted plastic bags and sand, albeit with differences in production processes. Nevertheless, the environmental and economic impact of such activities is still to be confirmed. The aim of this study is to propose a methodology for assessing and comparing the environmental and energetic performances of artisanal methods, and for defining the overall quality of the produced blocks. This methodology has been shaped through the analysis of
production processes operated by artisans/small enterprises in West Africa and through physic-mechanical tests on the blocks. A questionnaire which allows an insight into the process and on the product has been developed and tested over five processes. Results show that a high input energy level is observed through all the processes, while considerable savings of energy could be achieved. Moreover, tests results confirmed the importance of the utilised plastic concerning thermal dilatation, mechanical resistance at higher temperature and cooling-shrinkage effects. In conclusion, doubts remain about the technical and environmental effectiveness of the sampled experiences, durability of the products and sustainability of this approach. Nevertheless, being the collection and recycling of plastic wastes a potential income generation activity for marginalised social groups in urban environment, a process optimisation could improve the impact of blocks production. Alternative recycling activities should also be considered.
Resumo:
The paired adrenal (suprarenal) glands are flattened retroperitoneal endocrine glands closely applied to the medial aspect of the superior pole of each kidney. The internal structure of these pale yellow glands are incongruous in that the adrenal gland is composed of two discrete parts, namely an outer cortex enveloping a central medulla. The adrenal cortex and medulla contain distinct endocrine tissues that secrete different hormones and are regulated by separate control systems.
Resumo:
A number of constitutive models that account for creep or secondary compression and rate dependent behaviour of soil have been reviewed in terms of their strengths and weaknesses. Some results of numerical analysis of some embankments have been discussed and an effort has been made to find out their strengths and limitations.
Resumo:
BACKGROUND: PET/CT scanning can determine suitability for curative therapy and inform decision making when considering radical therapy in patients with non-small cell lung cancer (NSCLC). Metastases to central mediastinal lymph nodes (N2) may alter such management decisions. We report a 2 year retrospective series assessing N2 lymph node staging accuracy with PET/CT compared to pathological analysis at surgery.
METHODS: Patients with NSCLC attending our centre (excluding those who had induction chemotherapy) who had staging PET/CT scans and pathological nodal sampling between June 2006 and June 2008 were analysed. For each lymph node assessed pathologically, the corresponding PET/CT status was determined. 64 patients with 200 N2 lymph nodes were analysed.
RESULTS: Sensitivity of PET/CT scans for indentifying involved N2 lymph nodes was
39%, specificity 96% and overall accuracy 90%. For individual lymph node analysis, logistic regression demonstrated a significant linear association between PET/CT sensitivity and time from scanning to surgery (p=0.031) but not for specificity and accuracy. Those scanned <9 weeks before pathological sampling were significantly more sensitive (64% >9 weeks, 0% ≥ 9 weeks, p=0.013) and more accurate (94% <9 weeks, 81% ≥ 9 weeks, p=0.007). Differences in specificity were not seen (97% <9 weeks, 91% ≥ 9 weeks, p=0.228). No significant difference in specificity was found at any time point.
CONCLUSIONS: We recommend that if a PET/CT scan is older than 9 weeks, and management would be altered by the presence of N2 nodes, re-staging of the
mediastinum should be undertaken.
Resumo:
This study aims to investigate drilling process in carbon-fiber reinforced plastic (CFRP) composites with multilayer TiAlN/TiN PVD-coated tungsten carbide drill. The effect of process parameters have been investigated in drilling of Hexcel M21-T700GC. Thrust force and torque were measured online throughout the drilling experiments. Delamination were observed using optical microscope and analyzed via a developed algorithm based on digital image processing technique. Surface roughness of each hole was measured using a surface profilometer. In addition, the progression of tool wear in various surfaces of drill was observed using tool microscope and measured using image software. Our results indicate that the thrust force and torque increased with the increasing cutting speed and feed rate. Delamination and average surface roughness that rose with the increase in feed rate, however, decreased with the increasing cutting speed. The average surface roughness tended to increase with the increase in feed rate and decrease with the increasing cutting speed in drilling of carbon-fiber reinforced plastic (CFRP). Feed rate was found as the predominant factor on the drilling outputs. Abrasive wear was observed on both flank and relief surfaces, which created edge wear on cutting edges. No sign of chipping or plastic deformation has been observed on the surfaces of drills. © 2012 The Author(s).
Resumo:
Background: Cataract extraction is the most commonly performed surgery in the National Health Service. Myopia increases the risk of postoperative rhegmatogenous retinal detachment (RRD). The aim of this study was to determine the incidence and rate of RRD seven years after cataract extraction in highly myopic eyes. Methods: Retrospective review was performed of notes of all high myopes (axial length 26.0 mm or more) who underwent cataract extraction during the study period in one centre. Results: 84 eyes met the study criteria. Follow-up time from surgery was 93 to 147 months (median 127 months). The average axial length was 28.72 mm (sd 1.37). Two eyes developed post-operative RRD; the incidence was 2.4% and the rate one RRD per 441.6 person-years. The results of 15 other studies on the incidence of RRD after cataract extraction in high myopia were pooled and combined with our estimate. Conclusion: Both patients in our study who developed RRD had risk factors for this complication as well as high myopia. Risk factors are discussed in the light of our results and the pooled estimate. Our follow-up time is longer than most. Future case series should calculate rates to allow meaningful comparison of case series. © The Ulster Medical Society, 2009.
Resumo:
Introduction: Immediate reconstruction following mastectomy for breast cancer has been shown to be oncologically safe and associated with improved psychosocial outcomes for patients. Bostwick described a technique for one-stage implant based reconstruction, combining skin-sparing mastectomy with concurrent reduction of the skin envelope. This report reviews the experience of a single centre using skin-reducing mastectomy and one-stage implant reconstruction in both early stage breast cancer and risk-reducing mastectomy, with specific reference to frequency of complications, implant loss and oncological outcomes.
Methods and results: A retrospective review was undertaken to identify women who had undergone skin-reducing mastectomy and one-stage implant reconstruction using a de-epithelialised dermal flap, between October 2008 and October 2012. One hundred and four consecutive mastectomies, with reconstruction, were performed by two surgeons on 64 patients. No complications were seen in 43.8% of patients. At three months, four implants were lost (3.8% of breast reconstructions, 6.3% of patients), due to either peri-implant infection or mastectomy skin flap necrosis. One patient required unplanned return to theatre for evacuation of a haematoma. Minor mastectomy skin flap necrosis was seen in 10 breasts (9.6% of reconstructed breasts) and superficial wound infection in 8 breasts (7.7% of reconstructed breasts). All of these complications were managed conservatively and none required operative intervention. At a median follow up of 35 months (4-53 months) there had been one episode of ipsilateral axillary nodal recurrence.
Conclusion: One-stage implant reconstruction using a myo-dermal flap technique following skin-reducing mastectomy is safe and should be considered in selected patients. Most complications are minor and will resolve with conservative management. Major complications such as implant failure or immediate reoperation, were relatively uncommon (6.3% patients, 3.8% of reconstructed breasts). Early follow-up suggests that oncological outcomes are satisfactory, but longer follow-up is required to substantiate this. (C) 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Resumo:
Breast augmentation for cosmetic purposes is an increasingly common procedure in the USA and UK. In the USA in 2003, a total of 254 140 breast augmentation procedures were carried out [American Society of Plastic Surgeons, http://www.plasticsurgery.org/newsroom/ Procedural-Statistics-Press-Kit-Index.cfm9-1-2005; 2006.(1)]. It has been previously estimated that between 1 and 1.5 million women in the USA have prosthetic breast implants [Cook RR, Delongchamp RR, Woodbury M, et at. The prevalence of women with breast implants in the United States, 1989. J Clin Epidemiol 1995;48:519-25.(2)]. The UK National Breast Implant Registry has recorded a rise in the numbers of women receiving breast implants, with over 13 000 procedures registered in 2001; an estimated 77% of these were for cosmetic purposes. No association has been found between the presence of breast implants in a breast and an increased risk of breast cancer, and this subject has been comprehensively reviewed elsewhere [Hoshaw SJ, Klein PJ, Clark BD, et al. Breast implants and cancer: causation, delayed detection, and survival. Plast Reconstr Surg 2001; 107:1393-407.(3)]. However, as the population of women with breast implants ages, an increasing number of them will develop breast cancer; a reflection of the fact that the incidence of the disease increases with increasing age. Debate continues on the effect of breast implants on the efficacy of mammography in diagnosing breast cancer, and the role of other imaging techniques for this purpose, as well as the limitations that the presence of implants place on percutaneous biopsy techniques. We review the Literature on the radiological and tissue diagnosis of breast cancer in women with a history of previous augmentation mammaplasty. (c) 2007 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.