874 resultados para Subjective and objective hearing protection evaluation method
Resumo:
Primary objective: To trial the method of email-facilitated qualitative interviewing with people with traumatic brain injury (TBI). Research design: Qualitative semi-structured email-facilitated interviews. Procedures: Nineteen people (17 severe diagnosis) with a TBI participated in email interviews. Main outcomes and results: Findings indicate that this method facilitates the participation of people with TBI in qualitative interviews. Advantages include increased time for reflection, composing answers and greater control of the interview setting. In addition, the data indicates that people with a TBI are capable of greater insight, reflection and humour than indicated by previous research. Conclusion: Findings indicate that new technologies may advance data collection methods for people with cognitive-linguistic impairments who face participation barriers in face-to-face interviews.
Resumo:
Cyclothialidine, a natural product isolated from Streptomyces .filipinensis NR0484, has been proven to be a potent and selective inhibitor of the bacterial enzyme DNA gyrase. Gyrase inhibition results in cell death, the enzyme being the target of several currently used antibiotics. Cyclothialidine showed poor activity against whole bacterial cells, highlighting scope for improvement regarding cell membrane pemeability in order for the full potential of this new class of antibiotics to be realised, Structurally, cyclothialidine contains a 12-membered lactone ring which is partly integrated into a pentapeptide chain, with a substituted aromatic moiety bordering the lactone, Retrosynthetically it can be traced back to cis-3-hydroxyproline, 3,5-dihydroxy-2,6-dimethylbenzoic acid and four commercially available amino acids; two serine, one cysteine and one alanine. In this work, a model of cyclothialidine was synthesised in order to establish the methodology for more complex compounds. Analogues with hydroxy, dihydroxy and dihydroxymethyl substituted aromatic moieties were then prepared to ensure successful protection methods could be performed and the pharmacophore synthesised. The key aromatic moiety, 2,6-dimethyl-3,5-dihydroxybenzoic acid was produced via two successive Mannich reaction/reduction steps. Acid protection using 4-nitrobenzyl bromide and TBDMS hydroxyl protection followed by bromination of one methyl afforded the desired intermediate. Reaction with a serine/cysteine dipeptide, followed by deprotection and cyclisation under Mitsunobu conditions lead to the 12-membered lactone. An amine substituted aromatic analogue and also replacement of the cysteine sulphur by oxygen were attempted but without success. In an effort to improve cell permeability, a conjugate was synthesised between the pharmacophore and a cholesterol moiety. It was hoped the steroid fragment would serve to increase potency by escorting the molecule through the lipid environment of the cell membrane. The pharmacophore and conjugate were tested against a variety of bacterial strains but the conjugate failed to improve activity.
Resumo:
Background: The aim was to evaluate the validity and repeatability of the auto-refraction function of the Nidek OPD-Scan III (Nidek Technologies, Gamagori, Japan) compared with non-cycloplegic subjective refraction. The Nidek OPD-Scan III is a new aberrometer/corneal topographer workstation based on the skiascopy principle. It combines a wavefront aberrometer, topographer, autorefractor, auto keratometer and pupillometer/pupillographer. Methods: Objective refraction results obtained using the Nidek OPD-Scan III were compared with non-cycloplegic subjective refraction for 108 eyes of 54 participants (29 female) with a mean age of 23.7±9.5 years. Intra-session and inter-session variability were assessed on 14 subjects (28 eyes). Results: The Nidek OPD-Scan III gave slightly more negative readings than results obtained by subjective refraction (Nidek mean difference -0.19±0.36 DS, p<0.01 for sphere; -0.19±0.35 DS, p<0.01 for mean spherical equivalent; -0.002±0.23 DC, p=0.91 for cylinder; -0.06±0.38 DC, p=0.30 for J0 and -0.36±0.31 DC for J45, p=0.29). Auto-refractor results for 74 per cent of spherical readings and 60 per cent of cylindrical powers were within±0.25 of subjective refraction. There was high intra-session and inter-session repeatability for all parameters; 90 per cent of inter-session repeatability results were within 0.25 D. Conclusion: The Nidek OPD-Scan III gives valid and repeatable measures of objective refraction when compared with non-cycloplegic subjective refraction. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.
Resumo:
Internal quantum efficiency (IQE) of a high-brightness blue LED has been evaluated from the external quantum efficiency measured as a function of current at room temperature. Processing the data with a novel evaluation procedure based on the ABC-model, we have determined separately IQE of the LED structure and light extraction efficiency (LEE) of UX:3 chip. Full text Nowadays, understanding of LED efficiency behavior at high currents is quite critical to find ways for further improvement of III-nitride LED performance [1]. External quantum efficiency ηe (EQE) provides integral information on the recombination and photon emission processes in LEDs. Meanwhile EQE is the product of IQE ηi and LEE ηext at negligible carrier leakage from the active region. Separate determination of IQE and LEE would be much more helpful, providing correlation between these parameters and specific epi-structure and chip design. In this paper, we extend the approach of [2,3] to the whole range of the current/optical power variation, providing an express tool for separate evaluation of IQE and LEE. We studied an InGaN-based LED fabricated by Osram OS. LED structure grown by MOCVD on sapphire substrate was processed as UX:3 chip and mounted into the Golden Dragon package without molding. EQE was measured with Labsphere CDS-600 spectrometer. Plotting EQE versus output power P and finding the power Pm corresponding to EQE maximum ηm enables comparing the measurements with the analytical relationships ηi = Q/(Q+p1/2+p-1/2) ,p = P/Pm , and Q = B/(AC) 1/2 where A, Band C are recombination constants [4]. As a result, maximum IQE value equal to QI(Q+2) can be found from the ratio ηm/ηe plotted as a function of p1/2 +p1-1/2 (see Fig.la) and then LEE calculated as ηext = ηm (Q+2)/Q . Experimental EQE as a function of normalized optical power p is shown in Fig. 1 b along with the analytical approximation based on the ABCmodel. The approximation fits perfectly the measurements in the range of the optical power (or operating current) variation by eight orders of magnitude. In conclusion, new express method for separate evaluation of IQE and LEE of III-nitride LEDs is suggested and applied to characterization of a high-brightness blue LED. With this method, we obtained LEE from the free chip surface to the air as 69.8% and IQE as 85.7% at the maximum and 65.2% at the operation current 350 rnA. [I] G. Verzellesi, D. Saguatti, M. Meneghini, F. Bertazzi, M. Goano, G. Meneghesso, and E. Zanoni, "Efficiency droop in InGaN/GaN blue light-emitting diodes: Physical mechanisms and remedies," 1. AppL Phys., vol. 114, no. 7, pp. 071101, Aug., 2013. [2] C. van Opdorp and G. W. 't Hooft, "Method for determining effective non radiative lifetime and leakage losses in double-heterostructure lasers," 1. AppL Phys., vol. 52, no. 6, pp. 3827-3839, Feb., 1981. [3] M. Meneghini, N. Trivellin, G. Meneghesso, E. Zanoni, U. Zehnder, and B. Hahn, "A combined electro-optical method for the determination of the recombination parameters in InGaN-based light-emitting diodes," 1. AppL Phys., vol. 106, no. II, pp. 114508, Dec., 2009. [4] Qi Dai, Qifeng Shan, ling Wang, S. Chhajed, laehee Cho, E. F. Schubert, M. H. Crawford, D. D. Koleske, Min-Ho Kim, and Yongjo Park, "Carrier recombination mechanisms and efficiency droop in GalnN/GaN light-emitting diodes," App/. Phys. Leu., vol. 97, no. 13, pp. 133507, Sept., 2010. © 2014 IEEE.
Resumo:
Objectives: To develop a tool for the accurate reporting and aggregation of findings from each of the multiple methods used in a complex evaluation in an unbiased way. Study Design and Setting: We developed a Method for Aggregating The Reporting of Interventions in Complex Studies (MATRICS) within a gastroenterology study [Evaluating New Innovations in (the delivery and organisation of) Gastrointestinal (GI) endoscopy services by the NHS Modernisation Agency (ENIGMA)]. We subsequently tested it on a different gastroenterology trial [Multi-Institutional Nurse Endoscopy Trial (MINuET)]. We created three layers to define the effects, methods, and findings from ENIGMA. We assigned numbers to each effect in layer 1 and letters to each method in layer 2. We used an alphanumeric code based on layers 1 and 2 to every finding in layer 3 to link the aims, methods, and findings. We illustrated analogous findings by assigning more than one alphanumeric code to a finding. We also showed that more than one effect or method could report the same finding. We presented contradictory findings by listing them in adjacent rows of the MATRICS. Results: MATRICS was useful for the effective synthesis and presentation of findings of the multiple methods from ENIGMA. We subsequently successfully tested it by applying it to the MINuET trial. Conclusion: MATRICS is effective for synthesizing the findings of complex, multiple-method studies.
Resumo:
Objective: The Any Qualified Provider framework in the National Health Service has changed the way adult audiology services are offered in England. Under the new rules, patients are being offered a choice in geographical location and audiology provider. This study aimed to explore how choices in treatment are presented and to identify what information patients need when they are seeking help with hearing loss. Design: This study adopted qualitative methods of ethnographic observations and focus group interviews to identify information needed prior to, and during, help-seeking. Observational data and focus group data were analysed using the constant comparison method of grounded theory. Study sample: Participants were recruited from a community Health and Social Care Trust in the west of England. This service incorporates both an Audiology and a Hearing Therapy service. Twenty seven participants were involved in focus groups or interviews. Results: Participants receive little information beyond the detail of hearing aids. Participants report little information that was not directly related to uptake of hearing aids. Conclusions: Participant preferences were not explored and limited information resulted in decisions that were clinician-led. The gaps in information reflect previous data on clinician communication and highlight the need for consistent information on a range of interventions to manage hearing loss.
Resumo:
With the progress of computer technology, computers are expected to be more intelligent in the interaction with humans, presenting information according to the user's psychological and physiological characteristics. However, computer users with visual problems may encounter difficulties on the perception of icons, menus, and other graphical information displayed on the screen, limiting the efficiency of their interaction with computers. In this dissertation, a personalized and dynamic image precompensation method was developed to improve the visual performance of the computer users with ocular aberrations. The precompensation was applied on the graphical targets before presenting them on the screen, aiming to counteract the visual blurring caused by the ocular aberration of the user's eye. A complete and systematic modeling approach to describe the retinal image formation of the computer user was presented, taking advantage of modeling tools, such as Zernike polynomials, wavefront aberration, Point Spread Function and Modulation Transfer Function. The ocular aberration of the computer user was originally measured by a wavefront aberrometer, as a reference for the precompensation model. The dynamic precompensation was generated based on the resized aberration, with the real-time pupil diameter monitored. The potential visual benefit of the dynamic precompensation method was explored through software simulation, with the aberration data from a real human subject. An "artificial eye'' experiment was conducted by simulating the human eye with a high-definition camera, providing objective evaluation to the image quality after precompensation. In addition, an empirical evaluation with 20 human participants was also designed and implemented, involving image recognition tests performed under a more realistic viewing environment of computer use. The statistical analysis results of the empirical experiment confirmed the effectiveness of the dynamic precompensation method, by showing significant improvement on the recognition accuracy. The merit and necessity of the dynamic precompensation were also substantiated by comparing it with the static precompensation. The visual benefit of the dynamic precompensation was further confirmed by the subjective assessments collected from the evaluation participants.
Resumo:
Stroke is a leading cause of death and permanent disability worldwide, affecting millions of individuals. Traditional clinical scores for assessment of stroke-related impairments are inherently subjective and limited by inter-rater and intra-rater reliability, as well as floor and ceiling effects. In contrast, robotic technologies provide objective, highly repeatable tools for quantification of neurological impairments following stroke. KINARM is an exoskeleton robotic device that provides objective, reliable tools for assessment of sensorimotor, proprioceptive and cognitive brain function by means of a battery of behavioral tasks. As such, KINARM is particularly useful for assessment of neurological impairments following stroke. This thesis introduces a computational framework for assessment of neurological impairments using the data provided by KINARM. This is done by achieving two main objectives. First, to investigate how robotic measurements can be used to estimate current and future abilities to perform daily activities for subjects with stroke. We are able to predict clinical scores related to activities of daily living at present and future time points using a set of robotic biomarkers. The findings of this analysis provide a proof of principle that robotic evaluation can be an effective tool for clinical decision support and target-based rehabilitation therapy. The second main objective of this thesis is to address the emerging problem of long assessment time, which can potentially lead to fatigue when assessing subjects with stroke. To address this issue, we examine two time reduction strategies. The first strategy focuses on task selection, whereby KINARM tasks are arranged in a hierarchical structure so that an earlier task in the assessment procedure can be used to decide whether or not subsequent tasks should be performed. The second strategy focuses on time reduction on the longest two individual KINARM tasks. Both reduction strategies are shown to provide significant time savings, ranging from 30% to 90% using task selection and 50% using individual task reductions, thereby establishing a framework for reduction of assessment time on a broader set of KINARM tasks. All in all, findings of this thesis establish an improved platform for diagnosis and prognosis of stroke using robot-based biomarkers.
Resumo:
Situational awareness is achieved naturally by the human senses of sight and hearing in combination. Automatic scene understanding aims at replicating this human ability using microphones and cameras in cooperation. In this paper, audio and video signals are fused and integrated at different levels of semantic abstractions. We detect and track a speaker who is relatively unconstrained, i.e., free to move indoors within an area larger than the comparable reported work, which is usually limited to round table meetings. The system is relatively simple: consisting of just 4 microphone pairs and a single camera. Results show that the overall multimodal tracker is more reliable than single modality systems, tolerating large occlusions and cross-talk. System evaluation is performed on both single and multi-modality tracking. The performance improvement given by the audio–video integration and fusion is quantified in terms of tracking precision and accuracy as well as speaker diarisation error rate and precision–recall (recognition). Improvements vs. the closest works are evaluated: 56% sound source localisation computational cost over an audio only system, 8% speaker diarisation error rate over an audio only speaker recognition unit and 36% on the precision–recall metric over an audio–video dominant speaker recognition method.
Resumo:
Objectivos: O presente estudo avaliou a relação entre diversos aspectos objectivos e subjectivos inerentes às experiências de combate/guerra e sintomatologia associada à Perturbação Pós-Stress Traumático. Os instrumentos de auto-resposta utilizados na colheita dos dados foram analisados quanto às suas principais propriedades psicométricas. Métodos: A amostra foi composta por 105 combatentes da Guerra Colonial Portuguesa. Foram utilizados os seguintes instrumentos de avaliação: um questionário sóciodemográfico de auto-resposta para a caracterização da amostra, o Posttraumatic Stress Disorder Checklist (para militares), o Peritraumatic Dissociative Experiences Questionnaire, o Questionário de Experiências de Combate e duas escalas do Deployment Risk and Resilience Inventory, nomeadamente a Difficult Livings and Working Environment Scale e a Perceived Threat Scale. Resultados: O estudo das qualidades psicométricas dos instrumentos apresenta uma consistência interna superior a .86 e uma estabilidade temporal superior a .79. A análise factorial do Peritraumatic Dissociative Experiences Questionnaire apresenta bons valores na medida de Kaiser-Meyer-Olkin e no teste de esfericidade de Bartlett. Na rotação de Varimax é extraído um factor, predizendo a sua unidimensionalidade, que explica cerca de 70% da variância total do questionário. Os resultados relativos à validade divergentediscriminante indicam, por si só, que esta se apresenta de forma clara entre os instrumentos estudados (PCL-M, PDEQ, DLWES e PTS) no subgrupo com PTSD, com excepção da verificada entre o PCL-M e o PDEQ.. Quanto à validade de critério, constatam-se diferenças entre os subgrupos com e sem PTSD. Através do método da regressão linear múltipla, duas das seis variáveis têm, isoladamente, um peso preditivo significativo para a PTSD, nomeadamente a frequência de exposição a situações típicas e objectivas de combate/ guerra e os desconfortos diários durante a(s) comissão(ões). Ao considerarmos as variáveis no seu conjunto, aquelas que mais contribuem são a dissociação peritraumática e os desconfortos diários durante a(s) comissão(ões). Conclusão: Constata-se que os factores peritraumáticos em estudo desempenham um importante papel no desenvolvimento da sintomatologia inerente à PTSD. /
Resumo:
Surface flow types (SFT) are advocated as ecologically relevant hydraulic units, often mapped visually from the bankside to characterise rapidly the physical habitat of rivers. SFT mapping is simple, non-invasive and cost-efficient. However, it is also qualitative, subjective and plagued by difficulties in recording accurately the spatial extent of SFT units. Quantitative validation of the underlying physical habitat parameters is often lacking, and does not consistently differentiate between SFTs. Here, we investigate explicitly the accuracy, reliability and statistical separability of traditionally mapped SFTs as indicators of physical habitat, using independent, hydraulic and topographic data collected during three surveys of a c. 50m reach of the River Arrow, Warwickshire, England. We also explore the potential of a novel remote sensing approach, comprising a small unmanned aerial system (sUAS) and Structure-from-Motion photogrammetry (SfM), as an alternative method of physical habitat characterisation. Our key findings indicate that SFT mapping accuracy is highly variable, with overall mapping accuracy not exceeding 74%. Results from analysis of similarity (ANOSIM) tests found that strong differences did not exist between all SFT pairs. This leads us to question the suitability of SFTs for characterising physical habitat for river science and management applications. In contrast, the sUAS-SfM approach provided high resolution, spatially continuous, spatially explicit, quantitative measurements of water depth and point cloud roughness at the microscale (spatial scales ≤1m). Such data are acquired rapidly, inexpensively, and provide new opportunities for examining the heterogeneity of physical habitat over a range of spatial and temporal scales. Whilst continued refinement of the sUAS-SfM approach is required, we propose that this method offers an opportunity to move away from broad, mesoscale classifications of physical habitat (spatial scales 10-100m), and towards continuous, quantitative measurements of the continuum of hydraulic and geomorphic conditions which actually exists at the microscale.
Resumo:
Aims: To improve engagement of Health Visitors and Community Practitioners delivering the Healthy Child Programme with fathers. To evaluate a one-day, father-focused workshop with a supporting handbook for Practitioners. To identify institutional and organisational barriers to engagement with fathers. Background: The UK government policy encourages health professionals to engage with fathers. This derives from robust evidence that fathers’ early involvement with their children impacts positively on emotional, behavioural and educational development. Yet, there is little evidence that the importance of engaging fathers is reflected in Health Visitor training or that primary-care services are wholly embracing father-inclusive practice. The Fatherhood Institute (FI), a UK charity, has developed a workshop for Practitioners delivering the Healthy Child Programme. Method: A ‘before and after’ evaluation study, comprising a survey followed by telephone interviews, evaluated the impact of the FI workshop on Health Visitors’ and Community Practitioners’ knowledge, attitudes and behaviour in practice. A total of 134 Health Visitors and Community Practitioners from eight NHS Trusts in England attended the workshop from November 2011 to January 2014 at 12 sites. A specially constructed survey, incorporating a validated questionnaire, was administered before the workshop, immediately afterwards and three months later. Telephone interviews further explored participants’ responses. Findings: Analysis of the questionnaire data showed that the workshop and handbook improved participants’ knowledge, attitudes and behaviour in practice. This was sustained over a three-month period. In telephone interviews, most participants said that the workshop had raised their awareness of engaging fathers and offered them helpful strategies. However, they also spoke of barriers to engagement with fathers. NHS Trusts need to review the training and education of Health Visitors and Community Practitioners and take a more strategic approach towards father-inclusive practice and extend services to meet the needs of fathers.
Resumo:
Thesis (Master's)--University of Washington, 2016-08
Resumo:
The mixing performance of three passive milli-scale reactors with different geometries was investigated at different Reynolds numbers. The effects of design and operating characteristics such as mixing channel shape and volume flow rate were investigated. The main objective of this work was to demonstrate a process design method that uses on Computational Fluid Dynamics (CFD) for modeling and Additive Manufacturing (AM) technology for manufacture. The reactors were designed and simulated using SolidWorks and Fluent 15.0 software, respectively. Manufacturing of the devices was performed with an EOS M-series AM system. Step response experiments with distilled Millipore water and sodium hydroxide solution provided time-dependent concentration profiles. Villermaux-Dushman reaction experiments were also conducted for additional verification of CFD results and for mixing efficiency evaluation of the different geometries. Time-dependent concentration data and reaction evaluation showed that the performance of the AM-manufactured reactors matched the CFD results reasonably well. The proposed design method allows the implementation of new and innovative solutions, especially in the process design phase, for industrial scale reactor technologies. In addition, rapid implementation is another advantage due to the virtual flow design and due to the fast manufacturing which uses the same geometric file formats.
Resumo:
There is still a lack of an engineering approach for building Web systems, and the field of measuring the Web is not yet mature. In particular, there is an uncertainty in the selection of evaluation methods, and there are risks of standardizing inadequate evaluation practices. It is important to know whether we are evaluating the Web or specific website(s). We need a new categorization system, a different focus on evaluation methods, and an in-depth analysis that reveals the strengths and weaknesses of each method. As a contribution to the field of Web evaluation, this study proposes a novel approach to view and select evaluation methods based on the purpose and platforms of the evaluation. It has been shown that the choice of the appropriate evaluation method(s) depends greatly on the purpose of the evaluation.