944 resultados para Snow removal.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the enamel loss and composite remnants after debonding and clean-up. The tested null hypothesis is that there are no differences between different polishing systems regarding removing composite remnants without damaging the tooth surface. Brackets were bonded to 75 extracted human molars and removed after a storage period of 100 hours. The adhesive remnant index (ARI) was evaluated. The clean-up was carried out with five different procedures: 1. carbide bur; 2. carbide bur and Brownie and Greenie silicone polishers; 3. carbide bur and Astropol polishers; 4. carbide bur and Renew polishers; and 5. carbide bur, Brownie, Greenie and PoGo polishers. Silicone impressions were made at baseline (T0) and after debonding (T1) and polishing (T2) to produce plaster replicas. The replicas were analysed with a three-dimensional laser scanner and measured with analytical software. Statistical analysis was performed with the Kruskal-Wallis test and pairwise Wilcoxon tests with Bonferroni-Holm adjustment (α = 0.05). Enamel breakouts after debonding were detectable in 27 per cent of all cases, with a mean volume loss of 0.02 mm(3) (±0.03 mm(3)) and depth of 44.9 μm (±48.3 μm). The overall ARI scores was 3 with a few scores of 1 and 2. The composite remnants after debonding had a mean volume of 2.48 mm(3) (±0.92 mm(3)). Mean volume loss due to polishing was 0.05 mm(3) (±0.26 mm(3)) and the composite remnants had a mean volume of 0.22 mm(3) (±0.32 mm(3)). There were no statistically significant differences in volumetric changes after polishing (P = 0.054) between the different clean-up methods. However, sufficient clean-up without enamel loss was difficult to achieve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quantification of the structural properties of snow is traditionally based on model-based stereology. Model-based stereology requires assumptions about the shape of the investigated structure. Here, we show how the density, specific surface area, and grain boundary area can be measured using a design-based method, where no assumptions about structural properties are necessary. The stereological results were also compared to X-ray tomography to control the accuracy of the method. The specific surface area calculated with the stereological method was 19.8 ± 12.3% smaller than with X-ray tomography. For the density, the stereological method gave results that were 11.7 ± 12.1% larger than X-ray tomography. The statistical analysis of the estimates confirmed that the stereological method and the sampling used are accurate. This stereological method was successfully tested on artificially produced ice beads but also on several snow types. Combining stereology and polarisation microscopy provides a good estimate of grain boundary areas in ice beads and in natural snow, with some limitatio

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The variant Creutzfeldt-Jakob disease incidence peaked a decade ago and has since declined. Based on epidemiologic evidence, the causative agent, pathogenic prion, has not constituted a tangible contamination threat to large-scale manufacturing of human plasma-derived proteins. Nonetheless, manufacturers have studied the prion removal capabilities of various manufacturing steps to better understand product safety. Collectively analyzing the results could reveal experimental reproducibility and detect trends and mechanisms driving prion removal. STUDY DESIGN AND METHODS Plasma Protein Therapeutics Association member companies collected more than 200 prion removal studies on plasma protein manufacturing steps, including precipitation, adsorption, chromatography, and filtration, as well as combined steps. The studies used a range of model spiking agents and bench-scale process replicas. The results were grouped based on key manufacturing variables to identify factors impacting removal. The log reduction values of a group are presented for comparison. RESULTS Overall prion removal capacities evaluated by independent groups were in good agreement. The removal capacity evaluated using biochemical assays was consistent with prion infectivity removal measured by animal bioassays. Similar reduction values were observed for a given step using various spiking agents, except highly purified prion protein in some circumstances. Comparison between combined and single-step studies revealed complementary or overlapping removal mechanisms. Steps with high removal capacities represent the conditions where the physiochemical differences between prions and therapeutic proteins are most significant. CONCLUSION The results support the intrinsic ability of certain plasma protein manufacturing steps to remove prions in case of an unlikely contamination, providing a safeguard to products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Following vitrectomy for PVR-associated retinal detachment, placement of an encircling band, filling with silicone oil (SO) and successful retinal reattachment, a recurrence of PVR can develop. Retinal redetachment after SO removal is usually due to secondary or residual PVR. We wanted to ascertain whether the anatomical and functional outcomes of surgery in patients with a reattached retina and recurrent PVR can be improved by delaying the removal of SO. PATIENTS AND METHODS: 112 consecutive patients with PVR-associated retinal detachment who had undergone vitrectomy with SO filling, were monitored for at least 6 months after SO removal. Prior to SO removal, the retina posterior to the encircling band had to be completely reattached. Patients who developed PVR after SO filling were divided into two groups according to the duration of SO retention: 12 - 18 months (group 2: n = 48); > 18 months (group 3: n = 21). Individuals without PVR recurrence after SO filling and in whom the SO was consequently removed within 4 - 12 months served as control (group 1: n = 43). Anatomical success, intraocular pressure (IOP) and best-corrected visual acuity (BCVA) served as the primary clinical outcome parameters. RESULTS: Six months after SO removal, the anatomical success rates (86.3 %, 88.8 % and 84.6 %, in groups 1, 2 and 3, respectively; log rank = 0.794) and the BCVAs (p = 0.861) were comparable in the three groups. Mean IOP (p = 0.766), and the frequency of complications such as PVR recurrence (p = 0.936), bullous keratopathy (p = 0.981) and macular pucker (p = 0.943) were likewise similar. Patients in whom SO was retained for more than 18 months had the highest IOPs and required the heaviest dosage with anti-glaucoma drugs. CONCLUSIONS: In patients who develop a recurrence of PVR after vitrectomy and SO filling the surgeon can observe and treat retinal changes for up to 18 months without impairing the anatomical and functional outcomes. The retention of SO for more than 18 months does not improve the anatomical outcome. However, it can impair the functional outcome by precipitating the development of a persisting secondary glaucoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The three-dimensional documentation of footwear and tyre impressions in snow offers an opportunity to capture additional fine detail for the identification as present photographs. For this approach, up to now, different casting methods have been used. Casting of footwear impressions in snow has always been a difficult assignment. This work demonstrates that for the three-dimensional documentation of impressions in snow the non-destructive method of 3D optical surface scanning is suitable. The new method delivers more detailed results of higher accuracy than the conventional casting techniques. The results of this easy to use and mobile 3D optical surface scanner were very satisfactory in different meteorological and snow conditions. The method is also suitable for impressions in soil, sand or other materials. In addition to the side by side comparison, the automatic comparison of the 3D models and the computation of deviations and accuracy of the data simplify the examination and delivers objective and secure results. The results can be visualized efficiently. Data exchange between investigating authorities at a national or an international level can be achieved easily with electronic data carriers.