814 resultados para Sensor noise


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polymeric materials that conduct electricity are highly interesting for fundamental studies and beneficial for modern applications in e.g. solar cells, organic field effect transistors (OFETs) as well as in chemical and bio‐sensing. Therefore, it is important to characterize this class of materials with a wide variety of methods. This work summarizes the use of electrochemistry also in combination with spectroscopic methods in synthesis and characterization of electrically conducting polymers and other π‐conjugated systems. The materials studied in this work are intended for organic electronic devices and chemical sensors. Additionally, an important part of the presented work, concerns rational approaches to the development of water‐based inks containing conducting particles. Electrochemical synthesis and electroactivity of conducting polymers can be greatly enhanced in room temperature ionic liquids (RTILs) in comparison to conventional electrolytes. Therefore, poly(para‐phyenylene) (PPP) was electrochemically synthesized in the two representative RTILs: bmimPF6 and bmiTf2N (imidazolium and pyrrolidinium‐based salts, respectively). It was found that the electrochemical synthesis of PPP was significantly enhanced in bmimPF6. Additionally, the results from doping studies of PPP films indicate improved electroactivity in bmimPF6 during oxidation (p‐doping) and in bmiTf2N in the case of reduction (n‐doping). These findings were supported by in situ infrared spectroscopy studies. Conducting poly(benzimidazobenzophenanthroline) (BBL) is a material which can provide relatively high field‐effect mobility of charge carriers in OFET devices. The main disadvantage of this n‐type semiconductor is its limited processability. Therefore in this work BBL was functionalized with poly(ethylene oxide) PEO, varying the length of side chains enabling water dispersions of the studied polymer. It was found that functionalization did not distract the electrochemical activity of the BBL backbone while the processability was improved significantly in comparison to conventional BBL. Another objective was to study highly processable poly(3,4‐ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS) water‐based inks for controlled patterning scaled‐down to nearly a nanodomain with the intention to fabricate various chemical sensors. Developed PEDOT:PSS inks greatly improved printing of nanoarrays and with further modification with quaternary ammonium cations enabled fabrication of PEDOT:PSS‐based chemical sensors for lead (II) ions with enhanced adhesion and stability in aqueous environments. This opens new possibilities for development of PEDOT:PSS films that can be used in bio‐related applications. Polycyclic aromatic hydrocarbons (PAHs) are a broad group of π‐conjugated materials consisting of aromatic rings in the range from naphthalene to even hundred rings in one molecule. The research on this type of materials is intriguing, due to their interesting optical properties and resemblance of graphene. The objective was to use electrochemical synthesis to yield relatively large PAHs and fabricate electroactive films that could be used as template material in chemical sensors. Spectroscopic, electrochemical and electrical investigations evidence formation of highly stable films with fast redox response, consisting of molecules with 40 to 60 carbon atoms. Additionally, this approach in synthesis, starting from relatively small PAH molecules was successfully used in chemical sensor for lead (II).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recent emergence of low-cost RGB-D sensors has brought new opportunities for robotics by providing affordable devices that can provide synchronized images with both color and depth information. In this thesis, recent work on pose estimation utilizing RGBD sensors is reviewed. Also, a pose recognition system for rigid objects using RGB-D data is implemented. The implementation uses half-edge primitives extracted from the RGB-D images for pose estimation. The system is based on the probabilistic object representation framework by Detry et al., which utilizes Nonparametric Belief Propagation for pose inference. Experiments are performed on household objects to evaluate the performance and robustness of the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Denna avhandling handlar om metoder för att hitta begränsningar för det asymptotiska beteendet hos en förväntad uthoppstid från ett område omkring en xpunkt för processer som har normalfördelad störning. I huvudsak behandlas olika typer av autoregressiva processer. Fyra olika metoder används. En metod som använder principen för stora avvikelser samt en metod som jämför uthoppstiden med en återkomsttid ger övre begränsningar för den förväntade uthoppstiden. En martingalmetod och en metod för normalfördelade stokastiska variabler ger undre begränsningar. Metoderna har alla både förtjänster och nackdelar. Genom att kombinera de olika metoderna får man de bästa resultaten. Vi får fram gränsvärdet för det asymptotiska beteendet hos en uthoppstid för den multivariata autoregressiva processen, samt motsvarande gränsvärde för den univariata autoregressiva processen av ordning n.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tool center point calibration is a known problem in industrial robotics. The major focus of academic research is to enhance the accuracy and repeatability of next generation robots. However, operators of currently available robots are working within the limits of the robot´s repeatability and require calibration methods suitable for these basic applications. This study was conducted in association with Stresstech Oy, which provides solutions for manufacturing quality control. Their sensor, based on the Barkhausen noise effect, requires accurate positioning. The accuracy requirement admits a tool center point calibration problem if measurements are executed with an industrial robot. Multiple possibilities are available in the market for automatic tool center point calibration. Manufacturers provide customized calibrators to most robot types and tools. With the handmade sensors and multiple robot types that Stresstech uses, this would require great deal of labor. This thesis introduces a calibration method that is suitable for all robots which have two digital input ports free. It functions with the traditional method of using a light barrier to detect the tool in the robot coordinate system. However, this method utilizes two parallel light barriers to simultaneously measure and detect the center axis of the tool. Rotations about two axes are defined with the center axis. The last rotation about the Z-axis is calculated for tools that have different width of X- and Y-axes. The results indicate that this method is suitable for calibrating the geometric tool center point of a Barkhausen noise sensor. In the repeatability tests, a standard deviation inside robot repeatability was acquired. The Barkhausen noise signal was also evaluated after recalibration and the results indicate correct calibration. However, future studies should be conducted using a more accurate manipulator, since the method employs the robot itself as a measuring device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energian kulutuksen vähentäminen ja sen tutkiminen on kasvavan kiinnostuksen kohteena. Syntyneen lämmön mittaaminen on yksi tapa mitata energian siirtymistä. Lämpötilan mittaaminen on yleistä, vaikka usein on merkittävämpää selvittää missä ja miten lämpöenergia on siirtynyt. Tästä syystä tarvitaan lämpövuoantureita, jotka reagoivat suoraan lämpövuohon eli lämpöenergian siirtymiseen. Tässä tutkimuksessa suunnitellaan ja toteutetaan lämpövuoanturin mittauselektroniikka vaativaan käyttöympäristöön. Työssä käytettävän gradienttilämpövuoanturin tuottama jännitesignaali on mikrovolttiluokkaa ja ympäristön aiheuttama kohina voi olla huomattavasti suurempi. Tämän takia anturin tuottamaa signaalia on vahvistettava, jotta sitä voidaan mitata luotettavasti. Tutkimuksessa keskitytään vahvistimen suunnitteluun, mutta suunnittelussa on otettava huomioon koko järjestelmä. Anturin sähköiset ominaisuudet ja ympäristö asettavat rajoitteita vahvistimelle. Tavoitteena on selvittää miten voidaan mitata mikrovolttien jännitesignaalia mahdollisimman suurella taajuuskaistalla vaativassa käyttöympäristössä. Työn tuloksena syntyi mittalaite, jota voidaan käyttää vaativassa ympäristössä lämpövuon mittaamiseen. Suunnitteluparametrien mukainen vahvistus ja päästökaista sekä offset-jännitteen ryömintä saavutettiin suunnitellulla mittalaitteella, mutta offsetjännite ja kohina olivat hieman suunniteltua suuremmat. Mittalaitteella ja lämpövuoanturilla havaittiin selvästi lämpövuon muutoksia keinotekoisilla herätteillä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Functional MRI (fMRI) resting-state experiments are aimed at identifying brain networks that support basal brain function. Although most investigators consider a ‘resting-state’ fMRI experiment with no specific external stimulation, subjects are unavoidably under heavy acoustic noise produced by the equipment. In the present study, we evaluated the influence of auditory input on the resting-state networks (RSNs). Twenty-two healthy subjects were scanned using two similar echo-planar imaging sequences in the same 3T MRI scanner: a default pulse sequence and a reduced “silent” pulse sequence. Experimental sessions consisted of two consecutive 7-min runs with noise conditions (default or silent) counterbalanced across subjects. A self-organizing group independent component analysis was applied to fMRI data in order to recognize the RSNs. The insula, left middle frontal gyrus and right precentral and left inferior parietal lobules showed significant differences in the voxel-wise comparison between RSNs depending on noise condition. In the presence of low-level noise, these areas Granger-cause oscillations in RSNs with cognitive implications (dorsal attention and entorhinal), while during high noise acquisition, these connectivities are reduced or inverted. Applying low noise MR acquisitions in research may allow the detection of subtle differences of the RSNs, with implications in experimental planning for resting-state studies, data analysis, and ergonomic factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent advances in Information and Communication Technology (ICT), especially those related to the Internet of Things (IoT), are facilitating smart regions. Among many services that a smart region can offer, remote health monitoring is a typical application of IoT paradigm. It offers the ability to continuously monitor and collect health-related data from a person, and transmit the data to a remote entity (for example, a healthcare service provider) for further processing and knowledge extraction. An IoT-based remote health monitoring system can be beneficial in rural areas belonging to the smart region where people have limited access to regular healthcare services. The same system can be beneficial in urban areas where hospitals can be overcrowded and where it may take substantial time to avail healthcare. However, this system may generate a large amount of data. In order to realize an efficient IoT-based remote health monitoring system, it is imperative to study the network communication needs of such a system; in particular the bandwidth requirements and the volume of generated data. The thesis studies a commercial product for remote health monitoring in Skellefteå, Sweden. Based on the results obtained via the commercial product, the thesis identified the key network-related requirements of a typical remote health monitoring system in terms of real-time event update, bandwidth requirements and data generation. Furthermore, the thesis has proposed an architecture called IReHMo - an IoT-based remote health monitoring architecture. This architecture allows users to incorporate several types of IoT devices to extend the sensing capabilities of the system. Using IReHMo, several IoT communication protocols such as HTTP, MQTT and CoAP has been evaluated and compared against each other. Results showed that CoAP is the most efficient protocol to transmit small size healthcare data to the remote servers. The combination of IReHMo and CoAP significantly reduced the required bandwidth as well as the volume of generated data (up to 56 percent) compared to the commercial product. Finally, the thesis conducted a scalability analysis, to determine the feasibility of deploying the combination of IReHMo and CoAP in large numbers in regions in north Sweden.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydrogen (H2) fuel cells have been considered a promising renewable energy source. The recent growth of H2 economy has required highly sensitive, micro-sized and cost-effective H2 sensor for monitoring concentrations and alerting to leakages due to the flammability and explosiveness of H2 Titanium dioxide (TiO2) made by electrochemical anodic oxidation has shown great potential as a H2 sensing material. The aim of this thesis is to develop highly sensitive H2 sensor using anodized TiO2. The sensor enables mass production and integration with microelectronics by preparing the oxide layer on suitable substrate. Morphology, elemental composition, crystal phase, electrical properties and H2 sensing properties of TiO2 nanostructures prepared on Ti foil, Si and SiO2/Si substrates were characterized. Initially, vertically oriented TiO2 nanotubes as the sensing material were obtained by anodizing Ti foil. The morphological properties of tubes could be tailored by varying the applied voltages of the anodization. The transparent oxide layer creates an interference color phenomena with white light illumination on the oxide surface. This coloration effect can be used to predict the morphological properties of the TiO2 nanostructures. The crystal phase transition from amorphous to anatase or rutile, or the mixture of anatase and rutile was observed with varying heat treatment temperatures. However, the H2 sensing properties of TiO2 nanotubes at room temperature were insufficient. H2 sensors using TiO2 nanostructures formed on Si and SiO2/Si substrates were demonstrated. In both cases, a Ti layer deposited on the substrates by a DC magnetron sputtering method was successfully anodized. A mesoporous TiO2 layer obtained on Si by anodization in an aqueous electrolyte at 5°C showed diode behavior, which was influenced by the work function difference of Pt metal electrodes and the oxide layer. The sensor enabled the detection of H2 (20-1000 ppm) at low operating temperatures (50–140°C) in ambient air. A Pd decorated tubular TiO2 layer was prepared on metal electrodes patterned SiO2/Si wafer by anodization in an organic electrolyte at 5°C. The sensor showed significantly enhanced H2 sensing properties, and detected hydrogen in the range of a few ppm with fast response/recovery time. The metal electrodes placed under the oxide layer also enhanced the mechanical tolerance of the sensor. The concept of TiO2 nanostructures on alternative substrates could be a prospect for microelectronic applications and mass production of gas sensors. The gas sensor properties can be further improved by modifying material morphologies and decorating it with catalytic materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The microenvironment within the tumor plays a central role in cellular signaling. Rapidly proliferating cancer cells need building blocks for structures as well as nutrients and oxygen for energy production. In normal tissue, the vasculature effectively transports oxygen, nutrient and waste products, and maintains physiological pH. Within a tumor however, the vasculature is rarely sufficient for the needs of tumor cells. This causes the tumor to suffer from lack of oxygen (hypoxia) and nutrients as well as acidification, as the glycolytic end product lactate is accumulated. Cancer cells harbor mutations enabling survival in the rough microenvironment. One of the best characterized mutations is the inactivation of the von Hippel-Lindau protein (pVHL) in clear cell renal cell carcinoma (ccRCC). Inactivation causes constitutive activation of hypoxia-inducible factor HIF which is an important survival factor regulating glycolysis, neovascularization and apoptosis. HIFs are normally regulated by HIF prolyl hydroxylases (PHDs), which in the presence of oxygen target HIF α-subunit to ubiquitination by pVHL and degradation by proteasomes. In my thesis work, I studied the role of PHDs in the survival of carcinoma cells in hypoxia. My work revealed an essential role of PHD1 and PHD3 in cell cycle regulation through two cyclin-dependent kinase inhibitors (CKIs) p21 and p27. Depletion of PHD1 or PHD3 caused a cell cycle arrest and subjected the carcinoma cells to stress and impaired the survival.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Perovskite manganite compounds, Lai-xDxMnOs (D-divalent alkaline earth Ca, Sr or Ba), whose electrical and magnetic properties were first investigated nearly a half century ago, have attracted a great deal of attention due to their rich phase diagram. From the point of view of designing a future application, the strong pressure dependence of the resistivity and the accompanying effects in thin films have potential for application in pressure sensing and electronic devices. In this study we report our experimental investigations of pressure dependence of the resistivity of Lao.siSvo^iQMnOs and Lai-xSvxMnOs (LSMO) epitaxial films with x= 0.15, 0.20, 0.25, 0.30, 0.35, on SrTiOs substrates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Maestro en Ciencias Químicas con Especialidad en Química Analítica) U.A.N.L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RÉSUMÉ - Les images satellitales multispectrales, notamment celles à haute résolution spatiale (plus fine que 30 m au sol), représentent une source d’information inestimable pour la prise de décision dans divers domaines liés à la gestion des ressources naturelles, à la préservation de l’environnement ou à l’aménagement et la gestion des centres urbains. Les échelles d’étude peuvent aller du local (résolutions plus fines que 5 m) à des échelles régionales (résolutions plus grossières que 5 m). Ces images caractérisent la variation de la réflectance des objets dans le spectre qui est l’information clé pour un grand nombre d’applications de ces données. Or, les mesures des capteurs satellitaux sont aussi affectées par des facteurs « parasites » liés aux conditions d’éclairement et d’observation, à l’atmosphère, à la topographie et aux propriétés des capteurs. Deux questions nous ont préoccupé dans cette recherche. Quelle est la meilleure approche pour restituer les réflectances au sol à partir des valeurs numériques enregistrées par les capteurs tenant compte des ces facteurs parasites ? Cette restitution est-elle la condition sine qua non pour extraire une information fiable des images en fonction des problématiques propres aux différents domaines d’application des images (cartographie du territoire, monitoring de l’environnement, suivi des changements du paysage, inventaires des ressources, etc.) ? Les recherches effectuées les 30 dernières années ont abouti à une série de techniques de correction des données des effets des facteurs parasites dont certaines permettent de restituer les réflectances au sol. Plusieurs questions sont cependant encore en suspens et d’autres nécessitent des approfondissements afin, d’une part d’améliorer la précision des résultats et d’autre part, de rendre ces techniques plus versatiles en les adaptant à un plus large éventail de conditions d’acquisition des données. Nous pouvons en mentionner quelques unes : - Comment prendre en compte des caractéristiques atmosphériques (notamment des particules d’aérosol) adaptées à des conditions locales et régionales et ne pas se fier à des modèles par défaut qui indiquent des tendances spatiotemporelles à long terme mais s’ajustent mal à des observations instantanées et restreintes spatialement ? - Comment tenir compte des effets de « contamination » du signal provenant de l’objet visé par le capteur par les signaux provenant des objets environnant (effet d’adjacence) ? ce phénomène devient très important pour des images de résolution plus fine que 5 m; - Quels sont les effets des angles de visée des capteurs hors nadir qui sont de plus en plus présents puisqu’ils offrent une meilleure résolution temporelle et la possibilité d’obtenir des couples d’images stéréoscopiques ? - Comment augmenter l’efficacité des techniques de traitement et d’analyse automatique des images multispectrales à des terrains accidentés et montagneux tenant compte des effets multiples du relief topographique sur le signal capté à distance ? D’autre part, malgré les nombreuses démonstrations par des chercheurs que l’information extraite des images satellitales peut être altérée à cause des tous ces facteurs parasites, force est de constater aujourd’hui que les corrections radiométriques demeurent peu utilisées sur une base routinière tel qu’est le cas pour les corrections géométriques. Pour ces dernières, les logiciels commerciaux de télédétection possèdent des algorithmes versatiles, puissants et à la portée des utilisateurs. Les algorithmes des corrections radiométriques, lorsqu’ils sont proposés, demeurent des boîtes noires peu flexibles nécessitant la plupart de temps des utilisateurs experts en la matière. Les objectifs que nous nous sommes fixés dans cette recherche sont les suivants : 1) Développer un logiciel de restitution des réflectances au sol tenant compte des questions posées ci-haut. Ce logiciel devait être suffisamment modulaire pour pouvoir le bonifier, l’améliorer et l’adapter à diverses problématiques d’application d’images satellitales; et 2) Appliquer ce logiciel dans différents contextes (urbain, agricole, forestier) et analyser les résultats obtenus afin d’évaluer le gain en précision de l’information extraite par des images satellitales transformées en images des réflectances au sol et par conséquent la nécessité d’opérer ainsi peu importe la problématique de l’application. Ainsi, à travers cette recherche, nous avons réalisé un outil de restitution de la réflectance au sol (la nouvelle version du logiciel REFLECT). Ce logiciel est basé sur la formulation (et les routines) du code 6S (Seconde Simulation du Signal Satellitaire dans le Spectre Solaire) et sur la méthode des cibles obscures pour l’estimation de l’épaisseur optique des aérosols (aerosol optical depth, AOD), qui est le facteur le plus difficile à corriger. Des améliorations substantielles ont été apportées aux modèles existants. Ces améliorations concernent essentiellement les propriétés des aérosols (intégration d’un modèle plus récent, amélioration de la recherche des cibles obscures pour l’estimation de l’AOD), la prise en compte de l’effet d’adjacence à l’aide d’un modèle de réflexion spéculaire, la prise en compte de la majorité des capteurs multispectraux à haute résolution (Landsat TM et ETM+, tous les HR de SPOT 1 à 5, EO-1 ALI et ASTER) et à très haute résolution (QuickBird et Ikonos) utilisés actuellement et la correction des effets topographiques l’aide d’un modèle qui sépare les composantes directe et diffuse du rayonnement solaire et qui s’adapte également à la canopée forestière. Les travaux de validation ont montré que la restitution de la réflectance au sol par REFLECT se fait avec une précision de l’ordre de ±0.01 unités de réflectance (pour les bandes spectrales du visible, PIR et MIR), même dans le cas d’une surface à topographie variable. Ce logiciel a permis de montrer, à travers des simulations de réflectances apparentes à quel point les facteurs parasites influant les valeurs numériques des images pouvaient modifier le signal utile qui est la réflectance au sol (erreurs de 10 à plus de 50%). REFLECT a également été utilisé pour voir l’importance de l’utilisation des réflectances au sol plutôt que les valeurs numériques brutes pour diverses applications courantes de la télédétection dans les domaines des classifications, du suivi des changements, de l’agriculture et de la foresterie. Dans la majorité des applications (suivi des changements par images multi-dates, utilisation d’indices de végétation, estimation de paramètres biophysiques, …), la correction des images est une opération cruciale pour obtenir des résultats fiables. D’un point de vue informatique, le logiciel REFLECT se présente comme une série de menus simples d’utilisation correspondant aux différentes étapes de saisie des intrants de la scène, calcul des transmittances gazeuses, estimation de l’AOD par la méthode des cibles obscures et enfin, l’application des corrections radiométriques à l’image, notamment par l’option rapide qui permet de traiter une image de 5000 par 5000 pixels en 15 minutes environ. Cette recherche ouvre une série de pistes pour d’autres améliorations des modèles et méthodes liés au domaine des corrections radiométriques, notamment en ce qui concerne l’intégration de la FDRB (fonction de distribution de la réflectance bidirectionnelle) dans la formulation, la prise en compte des nuages translucides à l’aide de la modélisation de la diffusion non sélective et l’automatisation de la méthode des pentes équivalentes proposée pour les corrections topographiques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectif : Déterminer la fiabilité et la précision d’un prototype d’appareil non invasif de mesure de glucose dans le tissu interstitiel, le PGS (Photonic Glucose Sensor), en utilisant des clamps glycémiques multi-étagés. Méthodes : Le PGS a été évalué chez 13 sujets avec diabète de type 1. Deux PGS étaient testés par sujet, un sur chacun des triceps, pour évaluer la sensibilité, la spécificité, la reproductibilité et la précision comparativement à la technique de référence (le Beckman®). Chaque sujet était soumis à un clamp de glucose multi-étagé de 8 heures aux concentrations de 3, 5, 8 et 12 mmol/L, de 2 heures chacun. Résultats : La corrélation entre le PGS et le Beckman® était de 0,70. Pour la détection des hypoglycémies, la sensibilité était de 63,4%, la spécificité de 91,6%, la valeur prédictive positive (VPP) 71,8% et la valeur prédictive négative (VPN) 88,2%. Pour la détection de l’hyperglycémie, la sensibilité était de 64,7% et la spécificité de 92%, la VPP 70,8% et la VPN : 89,7%. La courbe ROC (Receiver Operating Characteristics) démontrait une précision de 0,86 pour l’hypoglycémie et de 0,87 pour l’hyperglycémie. La reproductibilité selon la « Clark Error Grid » était de 88% (A+B). Conclusion : La performance du PGS était comparable, sinon meilleure que les autres appareils sur le marché(Freestyle® Navigator, Medtronic Guardian® RT, Dexcom® STS-7) avec l’avantage qu’il n’y a pas d’aiguille. Il s’agit donc d’un appareil avec beaucoup de potentiel comme outil pour faciliter le monitoring au cours du traitement intensif du diabète. Mot clés : Diabète, diabète de type 1, PGS (Photonic Glucose Sensor), mesure continue de glucose, courbe ROC, « Clark Error Grid».

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cette thèse porte sur la capacité à détecter des compagnons de faible intensité en présence de bruit de tavelures dans le contexte de l’imagerie à haute gamme dynamique pour l’astronomie spatiale. On s’intéressera plus particulièrement à l’imagerie spectrale différentielle (ISD) obtenue en utilisant un étalon Fabry-Pérot comme filtre accordable. Les performances d’un tel filtre accordable sont présentées dans le cadre du Tunable Filter Imager (TFI), instrument conçu pour le télescope spatial James Webb (JWST). La capacité de l’étalon à supprimer les tavelures avec ISD est démontrée expérimentalement grâce à un prototype de l’étalon installé sur un banc de laboratoire. Les améliorations de contraste varient en fonction de la séparation, s’étendant d’un facteur 10 pour les séparations supérieures à 11 lambda/D jusqu’à un facteur 60 à 5 lambda/D. Ces résultats sont cohérents avec une étude théorique qui utilise un modèle basé sur la propagation de Fresnel pour montrer que les performances de suppression de tavelures sont limitées par le banc optique et non pas par l’étalon. De plus, il est démontré qu’un filtre accordable est une option séduisante pour l’imagerie à haute gamme dynamique combinée à la technique ISD. Une seconde étude basée sur la propagation de Fresnel de l’instrument TFI et du télescope, a permis de définir les performances de la technique ISD combinée avec un étalon pour l’astronomie spatiale. Les résultats prévoient une amélioration de contraste de l’ordre de 7 jusqu’à 100, selon la configuration de l’instrument. Une comparaison entre ISD et la soustraction par rotation a également été simulée. Enfin, la dernière partie de ce chapitre porte sur les performances de la technique ISD dans le cadre de l’instrument Near-Infrared Imager and Slitless Spectrograph (NIRISS), conçu pour remplacer TFI comme module scientifique à bord du Fine Guidance Sensor du JWST. Cent quatre objets localisés vers la région centrale de la nébuleuse d’Orion ont été caractérisés grâce à un spectrographe multi-objet, de basse résolution et multi-bande (0.85-2.4 um). Cette étude a relevé 7 nouvelles naines brunes et 4 nouveaux candidats de masse planétaire. Ces objets sont utiles pour déterminer la fonction de masse initiale sous-stellaire et pour évaluer les modèles atmosphériques et évolutifs futurs des jeunes objets stellaires et sous-stellaires. Combinant les magnitudes en bande H mesurées et les valeurs d’extinction, les objets classifiés sont utilisés pour créer un diagramme de Hertzsprung-Russell de cet amas stellaire. En accord avec des études antérieures, nos résultats montrent qu’il existe une seule époque de formation d’étoiles qui a débuté il y a environ 1 million d’années. La fonction de masse initiale qui en dérive est en accord avec des études antérieures portant sur d’autres amas jeunes et sur le disque galactique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new PVC membrane sensor, which is highly selective towards Ni (II) ions, has been developed using a thiophene-derivative Schiff base as the ionophore. The best performance was exhibited by the membrane having the composition percentage ratio of 5:3:61:31 (ionophore:NaTPB:DBP:PVC) (w=w), where NaTPB is the anion excluder, sodium tetraphenylborate and DBP is the plasticizing agent (dibutyl phthalate). The membrane exhibited a good Nernstian response for nickel ions over the concentration range of 1.0 10 1– 5.0 10 6M (limit of detection is 1.8 10 6 M) with a slope of 29.5 1.0mV per decade of activity. It has a fast response time of<20 s and can be used for a period of 4 months with good reproducibility. The sensor is suitable for use in aqueous solutions of a wide pH range of 3.2–7.9. The sensor shows high selectivity to nickel ions over a large number of mono-, bi- and trivalent cations. It has been successfully used as an indicator electrode in the potentiometric titration of nickel ions against EDTA and also for direct determination of nickel content in real samples – wastewater samples from electroplating industries and Indian chocolates.