998 resultados para Secondary Electrons Emission
Resumo:
Transarterial radioembolization consist in delivering small particles loaded with Yttrium90, a pure beta emitter, in order to treat primary and secondary liver tumors. This treatment needs precaution since inadequate delivery of these beads can lead to severe complications. Moreover, a precise radiation dosing is crucial to achieve a good clinical success and to avoid complications such as radioembolization-induced liver disease. This review describes all the precautions and highlights clinical and technical considerations that need to be taken to avoid complications.
Resumo:
Inverted ductal papilloma of the oral cavity is an infrequent benign neoplasm of papillary appearance that originates in the secretory duct of a salivary gland. The etiology is unknown, though some authors have related it to human papillomavirus (HPV) infection. We present the case of a 40-year-old woman with a tumor of the lower lip mucosa. Histopathological study of the lesion diagnosed inverted ductal papilloma of the oral cavity. Human papillomavirus DNA detection and typing based on tumor lesion DNA amplification and posterior hybridization, revealed no presence of viral DNA. The antecedents of trauma reported by the patient could have played an important role in the development of this tumor
Resumo:
By exciting at 940 nm, we have characterized the 1.84 m near infrared emission of trivalent thulium ions in Yb3+, Tm3+:KGd WO4 2 single crystals as a function of the dopant concentration and temperature, from 10 K to room temperature. An overall 3H6 Stark splitting of 470 cm−1 for the Tm3+ ions in the Yb3+, Tm3+:KGd WO4 2 was obtained. We also studied the blue emission at 476 nm Tm3+ and the near infrared emissions at 1.48 m Tm3+ and 1 m Yb3+ as a function of the dopant concentration. Experimental decay times of the 1G4, 3H4, and 3F4 Tm3+ and 2F5/2 Yb3+ excited states have been measured as a function of Yb3+ and Tm3+ ion concentrations. For the 3F4 →3H6 transition of Tm3+ ions, we used the reciprocity method to calculate the maximum emission cross section of 3.07 10−20 cm2 at 1.84 m for the polarization parallel to the Nm principal optical direction.
Resumo:
The main goal of this paper is to obtain a granular material formulated with Municipal Solid Waste Incinerarion (MSWI) bottom ash (BA) and air pollution control (APC) ash to be used as secondary building material. Previously, an optimum concrete mixture using both MSWI residues as aggregates was formulated. A compromise between the environmental behaviour and the economy of the process was considered. Unconfined compressive strength and abrasion resistance values were measured in order to evaluate the mechanical properties. From these results, the granular mixture was not suited for certain applications owing to the high BA/APC content and low cement percentages used to reduce the costs of the final product. Nevertheless, the leaching test performed showed that the concentrations of all heavy metals were below the limits established by the current Catalan legislation for their reutilization. Therefore, the material studied might be mainly used in embankments, where high mechanical properties are not needed and environmental safety is assured.
Trigeminal Neuralgia Secondary to Intracranial Lesions: A Prospective Series of 17 Consecutive Cases
Resumo:
Object: The purpose of the study was to assess the role of Gamma Knife surgery (GKS) in secondary trigeminal neuralgia (TN) caused by space-occupying lesions. Methods: From July 2010 till January 2015, 17 patients had GKS for secondary TN caused by intracranial lesions. The primary outcome was tumor control. The secondary outcomes were the alleviation of pain and the eventual secondary effects. Covariates were the age, duration of symptoms, duration till alleviation etc. Results: The mean age in this series was 63.3 years (range 39-79). The mean follow-up period was 1.85 years (range 0.5-3). Nine (52.9%) were meningiomas, five (29.4%) trigeminal schwannomas, two (11.8%) brain metastases and one (5.9%) arteriovenous malformation (AVM). Eight were located on the right side and nine on the left side. The mean duration of TN was 13.5 months (range 0.5-160). Follow-up was available for 16 patients (94.1%). Pain alleviation appeared after a mean time of 4.6 months (1-11) in 15 patients (88.2%). Five (29.4%) patients completely stopped medication in a mean time of 7 months (range 1-13) and three (17.6%) decreased it at half of the initial doses. No patient developed new hypoesthesia or other cranial nerve complication. The marginal doses for meningiomas and trigeminal schwannomas were 12 Gy (12-14), for metastasis 20 (20-20) and for AVM 24 Gy. The mean target volume was 1.84 cc (range 0.12-8.10). The mean prescription isodose volume was 2.65 cc (0.19-11.90). The mean maximal diameter was 19.9 (range 9-36). The mean number of isocenters was 14.2 (4-27). The mean duration was 76.9 minutes (range 25-172). The mean conformity, selectivity, Paddick and gradient index were: 0.99 (range 0.955-1), 0.701 (range 0.525-0.885), 0.694 (range 0.525-0.885) and 2.904 (range 2.654-3.371). At last follow-up, tumor decreased in 10 (58.8%) patients, was stable in 6 (35.3%) and increased in one (5.9%), the latest at 6 months. Conclusions: Gamma Knife surgery is safe and effective in treating intracranial lesions presenting with secondary TN. The initial pain freedom response was close to 90%, while having no secondary effect. Pain alleviation is achieved even in the absence of a volume variation of the lesions.
Short Report: Spinal Cord Stimulation in Thromboangiitis Obliterans and Secondary Raynaud's-Syndrome
Resumo:
Introduction: Spinal cord stimulation (SCS) may be a treatment option in limb ischemia occurring as a result of Thromboangiitis obliterans (TAO) or secondary Raynaud's-Syndrome (SRS). The impact of SCS on disease progression and micro-perfusion was prospectively evaluated during a follow-up (FU) of 4 years. Report: Under SCS, a significant increase in trans-cutaneous oxygen tension (tcpO2) was observed in TAO and a significant increase in systolic perfusion pressure at plethysmography was observed in SRS. Complete limb preservation was achieved in all patients who had reduced tobacco consumption. Discussion: SCS is an efficient therapeutic tool in TAO and SRS. Patient selection criteria are crucial for success.
Resumo:
We present a sample of three large near-relativistic (>50 keV) electron events observed in 2001 by both the ACE and the Ulysses spacecraft, when Ulysses was at high-northern latitudes (>60°) and close to 2 AU. Despite the large latitudinal distance between the two spacecraft, electrons injected near the Sun reached both heliospheric locations. All three events were associated with large solar flares, strong decametric type II radio bursts and accompanied by wide (>212°) and fast (>1400 km s-1) coronal mass ejections (CMEs). We use advanced interplanetary transport simulations and make use of the directional intensities observed in situ by the spacecraft to infer the electron injection profile close to the Sun and the interplanetary transport conditions at both low and high latitudes. For the three selected events, we find similar interplanetary transport conditions at different heliolatitudes for a given event, with values of the mean free path ranging from 0.04 AU to 0.27 AU. We find differences in the injection profiles inferred for each spacecraft. We investigate the role that sector boundaries of the heliospheric current sheet (HCS) have on determining the characteristics of the electron injection profiles. Extended injection profiles, associated with coronal shocks, are found if the magnetic footpoints of the spacecraft lay in the same magnetic sector as the associated flare, while intermittent sparse injection episodes appear when the spacecraft footpoints are in the opposite sector or a wrap in the HCS bounded the CME structure.
Resumo:
The secondary thickening of plant organs in extant dicotyledons is a massive growth process that constitutes the major carbon sink in perennial, woody plants. Yet, our understanding of its molecular genetic control has been mostly obtained by its analysis in an herbaceous annual model, Arabidopsis. Recent years have seen increased interest in this somewhat under-researched topic, and various (non-)cell autonomous factors that guide the extent and vascular patterning of secondary growth have been identified. Concomitantly, a more detailed understanding of vascular differentiation processes has been obtained through analyses of primary growth, mostly in the root meristem. A future challenge will be the integration of these patterning and differentiation modules together with cambial activity into the 4-dimensional frame of secondary thickening.
Bilateral breast swelling secondary to superior vena cava obstruction and subclavian vein thrombosis
Resumo:
Superior vena cava syndrome is defined by a set of signs and symptoms secondary to superior vena cava obstruction caused principally by malignant diseases. The present report describes the case of an unusual clinical manifestation of this syndrome with bilateral breast swelling, and emphasizes the relevance of knowledge on mammographic signs of systemic diseases.
Ambient radiation levels in positron emission tomography/computed tomography (PET/CT) imaging center
Resumo:
Objective: To evaluate the level of ambient radiation in a PET/CT center. Materials and Methods: Previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT center and in adjacent buildings. After the exposure period the dosimeters were collected and processed to determine the radiation level. Results: In none of the points selected for measurements the values exceeded the radiation dose threshold for controlled area (5 mSv/year) or free area (0.5 mSv/year) as recommended by the Brazilian regulations. Conclusion: In the present study the authors demonstrated that the whole shielding system is appropriate and, consequently, the workers are exposed to doses below the threshold established by Brazilian standards, provided the radiation protection standards are followed.
Resumo:
Nanoantennae show potential for photosynthesis research for two reasons; first by spatially confining light for experiments which require high spatial resolution, and second by enhancing the photon emission of single light-harvesting complexes. For effective use of nanoantennae a detailed understanding of the interaction between the nanoantenna and the light-harvesting complex is required. Here we report how the excitation and emission of multiple purple bacterial LH2s (light-harvesting complex 2) are controlled by single gold nanorod antennae. LH2 complexes were chemically attached to such antennae, and the antenna length was systematically varied to tune the resonance with respect to the LH2 absorption and emission. There are three main findings. (i) The polarization of the LH2 emission is fully controlled by the resonant nanoantenna. (ii) The largest fluorescence enhancement, of 23 times, is reached for excitation with light at λ = 850 nm, polarized along the long antenna-axis of the resonant antenna. The excitation enhancement is found to be 6 times, while the emission efficiency is increased 3.6 times. (iii) The fluorescence lifetime of LH2 depends strongly on the antenna length, with shortest lifetimes of [similar]40 ps for the resonant antenna. The lifetime shortening arises from an 11 times resonant enhancement of the radiative rate, together with a 2–3 times increase of the non-radiative rate, compared to the off-resonant antenna. The observed length dependence of radiative and non-radiative rate enhancement is in good agreement with simulations. Overall this work gives a complete picture of how the excitation and emission of multi-pigment light-harvesting complexes are influenced by a dipole nanoantenna.
Resumo:
The generation of "cold light", visible to the human eye, by chemical reactions has attracted the attention of the scientific community since the beginning of this century. Besides the academic interest in the elucidation of the mechanisms of excited state formations, many chemiluminescence reactions have found widespread analytical applications. Moreover, the phenomenon of chemiluminescence can also be used as a tool in undergraduate and college teaching. In this article, we describe several known chemiluminescence demonstrations, which are suitable for school teaching. The main objective of this work is to produce didactic material in Portuguese to stimulate Brazilian secondary and high school teachers to use these experiments in the classroom. The demonstrations include singlet oxygen emission, the luminol reaction, oscillating chemiluminescence and the peroxyoxalate reaction.
Resumo:
Performance standards for Positron emission tomography (PET) were developed to be able to compare systems from different generations and manufacturers. This resulted in the NEMA methodology in North America and the IEC in Europe. In practices, the NEMA NU 2- 2001 is the method of choice today. These standardized methods allow assessment of the physical performance of new commercial dedicated PET/CT tomographs. The point spread in image formation is one of the factors that blur the image. The phenomenon is often called the partial volume effect. Several methods for correcting for partial volume are under research but no real agreement exists on how to solve it. The influence of the effect varies in different clinical settings and it is likely that new methods are needed to solve this problem. Most of the clinical PET work is done in the field of oncology. The whole body PET combined with a CT is the standard investigation today in oncology. Despite the progress in PET imaging technique visualization, especially quantification of small lesions is a challenge. In addition to partial volume, the movement of the object is a significant source of error. The main causes of movement are respiratory and cardiac motions. Most of the new commercial scanners are in addition to cardiac gating, also capable of respiratory gating and this technique has been used in patients with cancer of the thoracic region and patients being studied for the planning of radiation therapy. For routine cardiac applications such as assessment of viability and perfusion only cardiac gating has been used. However, the new targets such as plaque or molecular imaging of new therapies require better control of the cardiac motion also caused by respiratory motion. To overcome these problems in cardiac work, a dual gating approach has been proposed. In this study we investigated the physical performance of a new whole body PET/CT scanner with NEMA standard, compared methods for partial volume correction in PET studies of the brain and developed and tested a new robust method for dual cardiac-respiratory gated PET with phantom, animal and human data. Results from performance measurements showed the feasibility of the new scanner design in 2D and 3D whole body studies. Partial volume was corrected, but there is no best method among those tested as the correction also depends on the radiotracer and its distribution. New methods need to be developed for proper correction. The dual gating algorithm generated is shown to handle dual-gated data, preserving quantification and clearly eliminating the majority of contraction and respiration movement