855 resultados para Retaining


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Population growth, together with the gradual social ascent in Brazil, reflects at the growing need for better use of urban spaces. In this context, the amount of new buildings to meet the demand in property market, the needs for creating new roads and highways, among others, make the use of geotechnical works and, more specifically, retaining walls, more and more common. One of the simplest solutions for underground works is the use of retaining structures using tie back walls for soil support, therefore, the present work deals with this kind of structures. This paper proposes the use of FTOOL software testing in predicting deformations in tie back walls, by comparing simulations of the presented model to a real and measured deformation case in Guabirotuba Formation (PR). The results showed the importance of defining the parameters such as stiffness and curtain geometry, as well as the definition of representative loads acting on it. Also, it was pointed out that the passive response of the steel rods depends on the horizontal displacement of the wall. The study concluded that the program generates very representative results when compared to field data and seems to be a promising tool for tie back structures displacement predictions

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During the retaining wall project in soil reinforced with geogrids and face milling system for segmental blocks is essential to determine the maximum connection resistance between the block and the geogrid. Thus, the aim of this study was to analyze the connection resistance based on ASTM D- 6638-01 between the segmental block model MW of Muros Terrae® company with the geogrids model Fortrac® M 35 / 20x20, Fortrac® M 55 / 30x20, Fortrac® M 80 / 30x20 and Fortrac® M 110 / 30x20 of HUESKER Synthetic GmbH using gravel 1 as a filling material. As a result, the resistance curves were obtained for the four models of geogrids and was described how it fracture. An additional investigation was the average gain connection resistance percentage when it is applied to geogrid a second layer instead of a single layer. The average percentage gains in the connection resistance to the geogrids model Fortrac® M 35 / 20x20, Fortrac® M 55 / 30x20, Fortrac® M 80 / 30x20 and Fortrac® M 110 / 30x20 were, respectively, 63.20 %, 63, 47%, 62.23 % and 51.34 %. Finally, we made a comparative analysis of the results of this study with those obtained by Guimarães (2006), Urashima et. al (2008) and Almeida and Toma (2011) to evaluate which combinations offered higher connection resistance

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As an alternative to improve the adaptation of prefabricated posts in flared canals and weakened roots, the option is for relining prefabricated pin, known as a technique of anatomical post. This technique, which can be made with composite resin increases the adjustment post to the walls of the canal and reduces the cementing line, causing the retaining post is less dependent on the mechanical properties of the cementing agent. This article aims to provide an overview of anatomical posts, specifically in the last two decades, based on studies extracted from Scielo, Scopus and Pubmed, referring to the following terms of MeSH Data Base: custom made fiber post, indirect fiber glass posts, root canal therapy and post and core tecnique. According to the literature review in this article, it can be concluded that this technique has been used by several authors and has been shown effective and promising, it creates an individualized retainer with better adaptation and decreased mechanical imbrication cementing line .

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The large number of dentists in Brazilian job market has increased the competitiveness in the dentistry field, leading the professional to use different strategies in an attempt to attract more patients. This study aimed to report different forms of dental marketing, showing how they can strengthen the bond between professional and patient, making it an alternative to face the competitive market. It was concluded that there are various marketing tools that can be applied in an effective and simple manner; since supported on ethics, it can make the dentist be highlighted, attracting and retaining patients and ensuring their professional success.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Curcumin possesses wide-ranging anti-inflammatory and anti-cancer properties and its biological activity can be correlated to its potent antioxidant capacity. Novel maghemite (gamma-Fe3O4) nanoparticles, characterized by a diameter of about 10 nm and possessing peculiar colloidal properties and surface interactions, called Surface Active Maghemite Nanoparticles (SAMN), were superficially modified with curcumin by simple incubation, due to the presence of under-coordinated Fe(III) atoms on nanoparticle surface. The resulting curcumin-modified SAMNs (SAMN@curcumin) were characterized by transmission electron microscopy (TEM), FTIR, Mossbauer, EPR and UV-Vis spectroscopy. The redox properties of bound curcumin were tested by electrochemistry. Finally, SAMN@curcumin was studied in the presence of different electroactive substances, namely hydroquinone, NADH and ferrocyanide, in order to assess its electrochemical behavior. Moreover, SAMN@curcumin was electrochemically tested in the presence of one of the most diffuse reactive oxygen specie, such as hydrogen peroxide, demonstrating its stability. SAMN@curcumin in which curcumin is firmly bound, but still retaining its redox features represents a feasible adduct: a magnetically drivable nano-bio-conjugate mimicking free Curcumin redox behavior. The proposed nanostructured material could be exploited as magnetic drivable curcumin vehicle for biomedical applications.