862 resultados para Recovery boiler
Resumo:
A 2D steady model for the annular two-phase flow of water and steam in the steam-generating boiler pipes of a liquid metal fast breeder reactor is proposed The model is based on thin-layer lubrication theory and thin aerofoil theory. The exchange of mass between the vapour core and the liquid film due to evaporation of the liquid film is accounted for using some simple thermodynamics models, and the resultant change of phase is modelled by proposing a suitable Stefan problem Appropriate boundary conditions for the now are discussed The resulting non-lineal singular integro-differential equation for the shape of the liquid film free surface is solved both asymptotically and numerically (using some regularization techniques) Predictions for the length to the dryout point from the entry of the annular regime are made The influence of both the traction tau provided by the fast-flowing vapour core on the liquid layer and the mass transfer parameter eta on the dryout length is investigated
Resumo:
The recovery and stability of DNA for the detection and genotyping of HPV in UCM-containing specimens, after exposure to denaturing reagents and stored for up to 2 years were evaluated. Samples were collected from 60 women who had cervical cytology specimens harboring cervical intraepithelial neoplasia (CIN) 2 or 3. All samples were stored in UCM and had been frozen at -20 degrees C following the addition of the denaturing reagent (sodium hydroxide) and the removal of the aliquot required for Hybrid Capture 2 testing for the identification of HPV DNA. The samples had been stored for 6, 12 and 24 months (20 samples for each storage time). HPV DNA extraction was performed according to a protocol designed specifically and the presence and quality of DNA was confirmed by human P-globin detection using the consensus primers G73 and G74. HPV DNA was amplified using the consensus primers PGMY09 and PGMY11, and reverse line-blot hybridization was used to detect type-specific amplicons for 37 HPV types. The DNA extracted from the denatured specimen was recovered in 57/60 (95%) of the samples. HPV DNA was detected in 56/57 (98%) of the recovered samples. Twenty-six of the 56 samples recovered (48%) were genotyped successfully. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Results obtained in a pilot-scale unit designed for COD removal and p-TBC (p-tert-butylcatechol) recovery from a butadiene washing stream (pH 14, 200,000 mg COD L(-1), highly toxic) at a petrochemical industry are presented. By adding H(3)PO(4), phase separation is achieved and p-TBC is successfully recovered (88 g L(-1) of washing stream). Information (time for phase separation and organic phase characterization) was gathered for designing a future industrial unit. The estimated heat generation rate was 990 kJ min(-1) and 15 min were enough to promote phase separation for a liquid column of approximately 1.15 m.
Resumo:
Hot rolling process is heat input process. The heat energy in hot rolled steel coils can be utilized. At SSAB Strip Product Borlänge when the hot rolled steel coils came out of the hot rolling mill they are at the temperature range of 500°C to 800°C. Heat energy contained by the one hot rolled steel coil is about 1981Kwh whereas the total heat energy for the year 2008 is 230 GWh/year.The potential of heat is too much but the heat dissipation rate is too slow. Different factors on which heat dissipation rate depends are discussed.Three suggestions are proposed to collect the waste heat from hot rolled steel coils.The 2nd proposal in which water basin is suggested would help not only to collect the waste heat but to decrease in the cooling time.
Resumo:
I detta examensarbete undersöktes möjligheten att installera värmeåtervinningssystem för ett flerfamiljehus i Hovgården som ligger en bit utanför Borlänge. I rapporten redovisas två olika sätt för energibesparingar som är aktuella för att ersätta borttagning av oljepannan som används i huset i dag. En rad svårigheter dök upp under undersökningen för installation av nytt värmesystem. Lämpliga lösningar kunde hittas efter mycket analys. Syftet med rapporten var att undersöka möjligheten och lönsamheten för installation av något av följande system; FVP eller VBX-modul som kan återvinna värme ur frånluften. Undersökningen visade att varken VBX eller FVP kan ersätta oljepannans värmeavgivning på ett tillfredsställande sätt. Med VBX ökas COP från 2,8 till 3,11 vilket leder till 17 MWh/år elbesparing. Däremot FVP kan försörja huset med 59 MWh/år men kan inte täcka effektbehovet för gården under kallaste dagarna. Resultatet blev att de båda undersökta systemen inte har möjlighet att ersätta oljeeldning.
Resumo:
Gaseous and particulate emissions from a residential pellet boiler and a stove are measured at a realistic 6-day operation sequence and during steady state operation. The aim is to characterize the emissions during each phase in order to identify when the major part of the emissions occur to enable actions for emission reduction where the savings can be highest. The characterized emissions comprised carbon monoxide (CO), nitrogen oxide (NO), total organic carbon (TOC) and particulate matter (PM 2.5). In this study, emissions were characterised by mass concentration and emissions during start-up and stop phases were also presented in accumulated mass. The influence of start-up and stop phases on the emissions, average emission factors for the boiler and stove were analysed using the measured data from a six-days test. The share of start-up and stop emissions are significant for CO and TOC contributing 95% and 89% respectively at the 20kW boiler and 82% and 89% respectively at the 12 kW stove. NO and particles emissions are shown to dominate during stationary operation.
Resumo:
With the building sector accounting for around 40% of the total energy consumption in the EU, energy efficiency in buildings is and continues to be an important issue. Great progress has been made in reducing the energy consumption in new buildings, but the large stock of existing buildings with poor energy performance is probably an even more crucial area of focus. This thesis deals with energy efficiency measures that can be suitable for renovation of existing houses, particularly low-temperature heating systems and ventilation systems with heat recovery. The energy performance, environmental impact and costs are evaluated for a range of system combinations, for small and large houses with various heating demands and for different climates in Europe. The results were derived through simulation with energy calculation tools. Low-temperature heating and air heat recovery were both found to be promising with regard to increasing energy efficiency in European houses. These solutions proved particularly effective in Northern Europe as low-temperature heating and air heat recovery have a greater impact in cold climates and on houses with high heating demands. The performance of heat pumps, both with outdoor air and exhaust air, was seen to improve with low-temperature heating. The choice between an exhaust air heat pump and a ventilation system with heat recovery is likely to depend on case specific conditions, but both choices are more cost-effective and have a lower environmental impact than systems without heat recovery. The advantage of the heat pump is that it can be used all year round, given that it produces DHW. Economic and environmental aspects of energy efficiency measures do not always harmonize. On the one hand, lower costs can sometimes mean larger environmental impact; on the other hand there can be divergence between different environmental aspects. This makes it difficult to define financial subsidies to promote energy efficiency measures.
Resumo:
Regression analysis has shown that recovery rates are determined by a variety of conditions at the time of default. These conditions can be broken into five major categories: (1) a security's seniority within the capital structure of the defaulting firm, (2) the type of default event, (3) firm-specific factors, (4) industry-specific factors, and (5) macroeconomic factors. Expectations of these inputs determine the expected recovery rate if default were to occur, thereby determining credit ratings and security prices. Although it is widely understood how recovery rate estimates influence credit rating assignments (the higher the expected recovery rate, the higher the assigned credit rating), no research, to the best of my knowledge, has investigated the reasons why higher rated securities recover more than lower rated securities in the event of default. Specifically, this paper will empirically investigate why securities originally rated investment grade, fallen angels, recover more than securities originally rated high yield in the event of default.
Resumo:
Contrary to previous research, training may improve exercise performance in a lizard, the brown anole. A brief, two-week training period resulted in increased performance speed and distance before exhaustion in trained lizards. Trained lizards were also able to more effectively use leg glycogen stores, however each of these improvements were not found in lizards treated with alcohol. Liver glycogen concentrations were also lower in alcohol-treated lizards, and patterns of liver glycogen concentrations during recovery indicate some hepatic lactate gluconeogenesis.
Resumo:
This work explores how Argentina overcame the Great Depression and asks whether active macroeconomic interventions made any contribution to the recovery. In particular, we study Argentine macroeconomic policy as it deviated from gold-standard orthodoxy after the final suspension of convertibility in 1929. As elsewhere, fiscal policy in Argentina was conservative, and had little power to smooth output. Monetary policy became heterodox after 1929. The first and most important stage of institutional change took place with the switch from a metallic monetary regime to a fiduciary regime in 1931; the Caja de Conversión (Conversion Office, a currency board) began rediscounting as a means to sterilize gold outflows and avoid deflationary pressures, thus breaking from orthodox "mIes of the game." However, the actual injections of liquidity were small' and were not enough to fully offset the incipient monetary contractions: the "Keynes" effect was weak or negative. Rather, recovery derived from changes in beliefs and expectations surrounding the shift in the monetary and exchange-rate regime,and the delinking of gold flows and the money base. Agents perceivod a new regime, as shown by the path of consumption, investment, and estimated ex ante real interest rates: the "Mundell" effect was dominant. Notably, this change of regime predated a later, and supposedly more significant, stage of institutional reform, namely the creation of the central bank in 1935. Still, the extent of intervention was weak, and insufficient to fully offset externaI shocks to prices and money. Argentine macropolicy was heterodox in terms of the change of regime, but still conservative in terms of the tentative scope of the measures taken .