822 resultados para Radiological safety


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Linezolid is used off-label to treat multidrug-resistant tuberculosis (MDR-TB) in absence of systematic evidence. We performed a systematic review and meta-analysis on efficacy, safety and tolerability of linezolid-containing regimes based on individual data analysis. 12 studies (11 countries from three continents) reporting complete information on safety, tolerability, efficacy of linezolid-containing regimes in treating MDR-TB cases were identified based on Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Meta-analysis was performed using the individual data of 121 patients with a definite treatment outcome (cure, completion, death or failure). Most MDR-TB cases achieved sputum smear (86 (92.5%) out of 93) and culture (100 (93.5%) out of 107) conversion after treatment with individualised regimens containing linezolid (median (inter-quartile range) times for smear and culture conversions were 43.5 (21-90) and 61 (29-119) days, respectively) and 99 (81.8%) out of 121 patients were successfully treated. No significant differences were detected in the subgroup efficacy analysis (daily linezolid dosage ≤600 mg versus >600 mg). Adverse events were observed in 63 (58.9%) out of 107 patients, of which 54 (68.4%) out of 79 were major adverse events that included anaemia (38.1%), peripheral neuropathy (47.1%), gastro-intestinal disorders (16.7%), optic neuritis (13.2%) and thrombocytopenia (11.8%). The proportion of adverse events was significantly higher when the linezolid daily dosage exceeded 600 mg. The study results suggest an excellent efficacy but also the necessity of caution in the prescription of linezolid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background: Tigecycline, an expanded broad-spectrum glycylcycline, exhibits in vitro activity against many common pathogens associated with community-acqui red pneumonia (CAP), as well as penetration into lung tissues that suggests effectiveness in ho spitalized CAP patients. The aim of the present study was to compare the efficacy and safety of intravenous (IV) tigecycline with IV levofloxacin in hospitalized adults with CAP. Methods: In this prospective, double-blin d, non-inferiority phase 3 trial, eligible patients with a clinical diagnosis of CAP supported by radiographic evidence were stratified by Fine Pneumonia Severity Index and randomized to tigecycline or levofloxacin for 7-14 days of therapy. Co-primary efficacy endpoints were clinical response in the clinically evaluable (CE) and clinical modified intent- to-treat (c-mITT) populations at te st-of-cure (Day 10-21 post-therapy). Results: Of the 428 patients who received at least on e dose of study drug, 79% had CAP of mild-moderate severity according to their Fine score. Clinical cure rates for the CE population were 88.9% for tigecycline and 85.3% for levofloxac in. Corresponding c-mITT population rates were 83.7% and 81.5%, respectively. Eradication rates for Streptococcus pneumoniae were 92% for tigecycline and 89% for levofloxac in. Nausea, vomiting, and diarrhoea were the most frequently reported adverse events. Rates of premature disc continuation of study drug or study withdrawal because of any adverse event were similar for both study drugs. Conclusion: These findings suggest that IV tigecycline is non-inferior to IV levofloxacin and is generally well-tolerated in the treatment of hospitalized adults with CAP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: To ensure vaccines safety, given the weaknesses of the national pharmacovigilance system in Cameroon, there is a need to identify effective interventions that can contribute to improving AEFI reporting. OBJECTIVE: To assess the effect of: (i) sending weekly SMS, or (ii) weekly supervisory visits on AEFI reporting rate during a meningitis immunization campaign conducted in Cameroon in 2012 using the meningitis A conjugate vaccine (MenAfriVac?). METHODS: Health facilities that met the inclusion criteria were randomly assigned to receive: (i) a weekly standardized SMS, (ii) a weekly standardized supervisory visits or (iii) no intervention. The primary outcome was the reported AEFI incidence rate from week 5 to 8 after the immunization campaign. Poisson regression model was used to estimate the effect of interventions after adjusting for health region, type of health facility, type and position of health workers as well as the cumulative number of AEFI reported from weeks 1 to 4. RESULTS: A total of 348 (77.2%) of 451 health facility were included, and 116 assigned to each of three groups. The incidence rate of reported AEFI per 100 health facility per week was 20.0 (15.9-24.1) in the SMS group, 40.2 (34.4-46.0) in supervision group and 13.6 (10.1-16.9) in the control group. Supervision led to a significant increase of AEFI reporting rate compared to SMS [adjusted RR=2.1 (1.6-2.7); p<0.001] and control [RR=2.8(2.1-3.7); p<0.001)] groups. The effect of SMS led to some increase in AEFI reporting rate compared to the control group, but the difference was not statistically significant [RR=1.4(0.8-1.6); p=0.07)]. CONCLUSION: Supervision was more effective than SMS or routine surveillance in improving AEFI reporting rate. It should be part of any AEFI surveillance system. SMS could be useful in improving AEFI reporting rates but strategies need to be found to improve its effectiveness, and thus maximize its benefits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ydinvoimalaitokset on suunniteltu ja rakennettu niin, että niillä on kyky selviytyä erilaisista käyttöhäiriöistä ja onnettomuuksista ilman laitoksen vahingoittumista sekä väestön ja ympäristön vaarantumista. On erittäin epätodennäköistä, että ydinvoimalaitosonnettomuus etenee reaktorisydämen vaurioitumiseen asti, minkä seurauksena sydänmateriaalien hapettuminen voi tuottaa vetyä. Jäädytyspiirin rikkoutumisen myötä vety saattaa kulkeutua ydinvoimalaitoksen suojarakennukseen, jossa se voi muodostaa palavan seoksen ilman hapen kanssa ja palaa tai jopa räjähtää. Vetypalosta aiheutuvat lämpötila- ja painekuormitukset vaarantavat suojarakennuksen eheyden ja suojarakennuksen sisällä olevien turvajärjestelmien toimivuuden, joten tehokas ja luotettava vedynhallintajärjestelmä on tarpeellinen. Passiivisia autokatalyyttisiä vetyrekombinaattoreita käytetäänyhä useammissa Euroopan ydinvoimaitoksissa vedynhallintaan. Nämä rekombinaattorit poistavat vetyä katalyyttisellä reaktiolla vedyn reagoidessa katalyytin pinnalla hapen kanssa muodostaen vesihöyryä. Rekombinaattorit ovat täysin passiivisiaeivätkä tarvitse ulkoista energiaa tai operaattoritoimintaa käynnistyäkseen taitoimiakseen. Rekombinaattoreiden käyttäytymisen tutkimisellatähdätään niiden toimivuuden selvittämiseen kaikissa mahdollisissa onnettomuustilanteissa, niiden suunnittelun optimoimiseen sekä niiden optimaalisen lukumäärän ja sijainnin määrittämiseen suojarakennuksessa. Suojarakennuksen mallintamiseen käytetään joko keskiarvoistavia ohjelmia (Lumped parameter (LP) code), moniulotteisia virtausmalliohjelmia (Computational Fluid Dynamics, CFD) tai näiden yhdistelmiä. Rekombinaattoreiden mallintaminen on toteutettu näissä ohjelmissa joko kokeellisella, teoreettisella tai yleisellä (eng. Global Approach) mallilla. Tämä diplomityö sisältää tulokset TONUS OD-ohjelman sisältämän Siemens FR90/1-150 rekombinaattorin mallin vedynkulutuksen tarkistuslaskuista ja TONUS OD-ohjelmalla suoritettujen laskujen tulokset Siemens rekombinaattoreiden vuorovaikutuksista. TONUS on CEA:n (Commissariat à 1'En¬ergie Atomique) kehittämä LP (OD) ja CFD -vetyanalyysiohjelma, jota käytetään vedyn jakautumisen, palamisenja detonaation mallintamiseen. TONUS:sta käytetään myös vedynpoiston mallintamiseen passiivisilla autokatalyyttisillä rekombinaattoreilla. Vedynkulutukseen vaikuttavat tekijät eroteltiin ja tutkittiin yksi kerrallaan. Rekombinaattoreiden vuorovaikutuksia tutkittaessa samaan tilavuuteen sijoitettiin eri kokoisia ja eri lukumäärä rekombinaattoreita. Siemens rekombinaattorimalli TONUS OD-ohjelmassa laskee vedynkulutuksen kuten oletettiin ja tulokset vahvistavat TONUS OD-ohjelman fysikaalisen laskennan luotettavuuden. Mahdollisia paikallisia jakautumia tutkitussa tilavuudessa ei voitu havaita LP-ohjelmalla, koska se käyttäälaskennassa suureiden tilavuuskeskiarvoja. Paikallisten jakautumien tutkintaan tarvitaan CFD -laskentaohjelma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Influenza vaccines are recommended for administration by the intramuscular route. However, many physicians use the subcutaneous route for patients receiving an oral anticoagulant because this route is thought to induce fewer hemorrhagic side effects. Our aim is to assess the safety of intramuscular administration of influenza vaccine in patients on oral anticoagulation therapy. Methods: Design: Randomised, controlled, single blinded, multi-centre clinical trial. Setting: 4 primary care practices in Barcelona, Spain. Participants: 229 patients on oral anticoagulation therapy eligible for influenza vaccine during the 20032004 season. Interventions: intramuscular administration of influença vaccine in the experimental group (129 patients) compared to subcutaneous administration in the control group (100 patients). Primary outcome: change in the circumference of the arm at the site of injection at 24 hours. Secondary outcomes: appearance of local reactions and pain at 24 hours and at 10 days; change in INR (International Normalized Ratio) at 24 hours and at 10 days. Analysis was by intention to treat using the 95% confidence intervals of the proportions or mean differences. Results: Baseline variables in the two groups were similar. No major side effects or major haemorrhage during the follow-up period were reported. No significant differences were observed in the primary outcome between the two groups. The appearance of local adverse reactions was more frequent in the subcutaneous administration group (37,4% vs. 17,4%, 95% confidence interval of the difference 8,2% to 31,8%). Conclusion: This study shows that the intramuscular administration route of influenza vaccine in patients on anticoagulant therapy does not have more side effects than the subcutaneous administration route

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Institute of Radiation Physics (IRA) is attached to the Department of Medical Radiology at the Vaud University Hospital Center (CHUV) in Lausanne. The Institute's main tasks are strongly linked to the medical activities of the Department: radiotherapy, radiodiagnostics, interventional radiology and nuclear medicine. The Institute also works in the fields of operational radiation protection, radiation metrology and radioecology. In the case of an accident involving radioactive materials, the emergency services are able to call on the assistance of radiation protection specialists. In order to avoid having to create and maintain a specific structure, both burdensome and rarely needed, Switzerland decided to unite all existing emergency services for such events. Thus, the IRA was invited to participate in this network. The challenge is therefore to integrate a university structure, used to academic collaborations and the scientific approach, to an interventional organization accustomed to strict policies, a military-style command structure and "drilled" procedures. The IRA's solution entails mobilizing existing resources and the expertise developed through professional experience. The main asset of this solution is that it involves the participation of committed collaborators who remain in a familiar environment, and are able to use proven materials and mastered procedures, even if the atmosphere of an accident situation differs greatly from regular laboratory routines. However, this solution requires both a commitment to education and training in emergency situations, and a commitment in terms of discipline by each collaborator in order to be integrated into a response plan supervised by an operational command center.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis gives an overview of the validation process for thermal hydraulic system codes and it presents in more detail the assessment and validation of the French code CATHARE for VVER calculations. Three assessment cases are presented: loop seal clearing, core reflooding and flow in a horizontal steam generator. The experience gained during these assessment and validation calculations has been used to analyze the behavior of the horizontal steam generator and the natural circulation in the geometry of the Loviisa nuclear power plant. The cases presented are not exhaustive, but they give a good overview of the work performed by the personnel of Lappeenranta University of Technology (LUT). Large part of the work has been performed in co-operation with the CATHARE-team in Grenoble, France. The design of a Russian type pressurized water reactor, VVER, differs from that of a Western-type PWR. Most of thermal-hydraulic system codes are validated only for the Western-type PWRs. Thus, the codes should be assessed and validated also for VVER design in order to establish any weaknesses in the models. This information is needed before codes can be used for the safety analysis. Theresults of the assessment and validation calculations presented here show that the CATHARE code can be used also for the thermal-hydraulic safety studies for VVER type plants. However, some areas have been indicated which need to be reassessed after further experimental data become available. These areas are mostly connected to the horizontal stem generators, like condensation and phase separation in primary side tubes. The work presented in this thesis covers a large numberof the phenomena included in the CSNI code validation matrices for small and intermediate leaks and for transients. Also some of the phenomena included in the matrix for large break LOCAs are covered. The matrices for code validation for VVER applications should be used when future experimental programs are planned for code validation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Cardiac arrest causes ischaemic brain injury. Arterial carbon dioxide tension (PaCO2) is a major determinant of cerebral blood flow. Thus, mild hypercapnia in the 24 h following cardiac arrest may increase cerebral blood flow and attenuate such injury. We describe the Carbon Control and Cardiac Arrest (CCC) trial. METHODS/DESIGN: The CCC trial is a pilot multicentre feasibility, safety and biological efficacy randomized controlled trial recruiting adult cardiac arrest patients admitted to the intensive care unit after return of spontaneous circulation. At admission, using concealed allocation, participants are randomized to 24 h of either normocapnia (PaCO2 35 to 45 mmHg) or mild hypercapnia (PaCO2 50 to 55 mmHg). Key feasibility outcomes are recruitment rate and protocol compliance rate. The primary biological efficacy and biological safety measures are the between-groups difference in serum neuron-specific enolase and S100b protein levels at 24 h, 48 h and 72 h. Secondary outcome measure include adverse events, in-hospital mortality, and neurological assessment at 6 months. DISCUSSION: The trial commenced in December 2012 and, when completed, will provide clinical evidence as to whether targeting mild hypercapnia for 24 h following intensive care unit admission for cardiac arrest patients is feasible and safe and whether it results in decreased concentrations of neurological injury biomarkers compared with normocapnia. Trial results will also be used to determine whether a phase IIb study powered for survival at 90 days is feasible and justified. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry ACTRN12612000690853 .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This study aimed to survey current practices in European epilepsy monitoring units (EMUs) with emphasis on safety issues. METHODS: A 37-item questionnaire investigating characteristics and organization of EMUs, including measures for prevention and management of seizure-related serious adverse events (SAEs), was distributed to all identified European EMUs plus one located in Israel (N=150). RESULTS: Forty-eight (32%) EMUs, located in 18 countries, completed the questionnaire. Epilepsy monitoring unit beds are 1-2 in 43%, 3-4 in 34%, and 5-6 in 19% of EMUs; staff physicians are 1-2 in 32%, 3-4 in 34%, and 5-6 in 19% of EMUs. Personnel operating in EMUs include epileptologists (in 69% of EMUs), clinical neurophysiologists trained in epilepsy (in 46% of EMUs), child neurologists (in 35% of EMUs), neurology and clinical neurophysiology residents (in 46% and in 8% of EMUs, respectively), and neurologists not trained in epilepsy (in 27% of EMUs). In 20% of EMUs, patients' observation is only intermittent or during the daytime and primarily carried out by neurophysiology technicians and/or nurses (in 71% of EMUs) or by patients' relatives (in 40% of EMUs). Automatic detection systems for seizures are used in 15%, for body movements in 8%, for oxygen desaturation in 33%, and for ECG abnormalities in 17% of EMUs. Protocols for management of acute seizures are lacking in 27%, of status epilepticus in 21%, and of postictal psychoses in 87% of EMUs. Injury prevention consists of bed protections in 96% of EMUs, whereas antisuffocation pillows are employed in 21%, and environmental protections in monitoring rooms and in bathrooms are implemented in 38% and in 25% of EMUs, respectively. The most common SAEs were status epilepticus reported by 79%, injuries by 73%, and postictal psychoses by 67% of EMUs. CONCLUSIONS: All EMUs have faced different types of SAEs. Wide variation in practice patterns and lack of protocols and of precautions to ensure patients' safety might promote the occurrence and severity of SAEs. Our findings highlight the need for standardized and shared protocols for an effective and safe management of patients in EMUs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the years, transfusion medicine has been faced to many different problems, notably those related to transmission of pathogens. Major progresses have been accomplished in terms of security. However, nowadays, the discipline is confronted to the day-to-day variability and availability of blood products. More and more donors are excluded from blood donation due to various reasons, and the donor selection criteria have increased over the years, influencing the number of donors able to give blood. This paradox represents one of the constraints that transfusion medicine should resolve in the future. This paper presents some aspects either common or different between France and Switzerland.