746 resultados para Radiografia intervencionista
Resumo:
The atlantoaxial subluxation or luxation is an instability of this articulation that produces excessive flexion of this joint causing the cranial aspect of the axis to rotate dorsally into the vertebral channel with subsequent spinal cord compression. This disorder is most commonly found in young small breed dogs. The diagnosis of this disease is done by survey radiographs, where there is a larger distance between the atlas dorsal arch and the axis spinal process characterize the atlantoaxial subluxation. Surgical stabilization is the treatment of choice and multiple implants show the best results to stabilize the atlantoaxial joint. The main complications are sudden death or implant failure. The sudden death happens because of cardiorespiratory arrest and it is most likely caused by brainstem iatrogenic trauma. However, a larger study comparing different surgical stabilization techniques should be performed to evaluate relative success rates in dogs that have the same initial neurologic status
Resumo:
O uso de radiações ionizantes (R.I.), nas mais variadas atividades tem aumentado nas últimas décadas. Com o avanço tecnológico, novos e sofisticados equipamentos emissores de R.I. tem surgido no cenário nacional, o que torna imperativo a difusão do conhecimento sobre os conceitos de proteção radiológica junto à comunidade em geral, e neste sentido, o curso de física médica desenvolve um importante papel, quer seja no aspecto informativo quanto formativo de cidadãos e profissionais críticos e politicamente corretos, que possam contribuir com as Políticas Públicos dos órgãos normatizadores e fiscalizadores das atividades de vigilância sanitária. Conforme a legislação atual (Resolução SS-625 de 14/12/1994, da Secretaria de Estado da Saúde, e Portaria 453 de 01/06/1998 da Vigilância Sanitária do Ministério da Saúde), todos os serviços que utilizam radiações ionizantes devem realizar testes de avaliação dos parâmetros radiométricos dos equipamentos emissores de R.I., sendo exigidos as medidas de Levantamento Radiométrico das instalações, o Teste de Radiação de Fuga do cabeçote emissor e a implementação de Programa de Garantia de Qualidade dos equipamentos e dos procedimentos radiológicos. Este procedimento tem como objetivo principal a obtenção de imagens radiográficas com qualidade e a segurança de pacientes e profissionais, evitando a exposição desnecessária à radiação de pacientes e profissionais. A correta realização de procedimentos radiológicos além de reduzir a dose nos pacientes também promove significativa diminuição nos custos, por não haver necessidade da repetição dos exames. No Brasil, conforme dados da Secretaria de Atenção à Saúde SAS/MS, atualmente existem instalados 4.469 mamógrafos, 25.930 aparelhos de raios-x médicos, 39.438 aparelhos de raios-x odontológicos e...(Resumo completo, clicar acesso eletrônico abaixo)
Resumo:
It is imortant to be able to evaluate the cardiact size . In 1995, was proposed by Buchanan and Bücheler a new way to measure the dimensions of the cardiac silhouette. This study aims to gather several studies of the cardiac dimensions by VHS method in the right lateral recumbency of of different breeds of dogs in a single work, facilitating the assess to information. Deep chest breeds have a smaller mean VHS value than the barrel chest breeds, showing that there is a variation of the VHS values acoording to the thoracic conformation of each breed, which indicates that there is a need to recognize the specific VHS values according to the breed standard to not to interpret the cardiac measurement in a wrong way through not compatible reference values for the animal. There is the individual variation that should be taken into accont at the time of measurement. The VHS is a helper method to a radiographic evaluation of the heart, and the ultrasonography remains the gold standard for the evaluation of the cardiac chambers and other changes of the heart
Resumo:
Legg-Calvé-Perthes disease is a non-inflammatory aseptic necrosis of the head of the femur that is found in both young animals and humans before the gap in the femur head closes. In the fields of both human and veterinary medicine the cause of this condition is not known for certain. Various factors have been put forward in the literature as being responsible for the incidence of this condition such as: abnormalities in coagulation, changes in blood flow in the arteries, a septic obstruction in the draining of the epiphysis or the upper parts of the femur, trauma, growth cycle, hyperactivity in a child, genetic influences and dietary factors. Case histories in dogs show that the first stages of the condition progress slowly but that limping or putting weight on the limb worsens at 6 to 8 weeks. Some owners talk about a sharp onset in clinical lameness. Other clinical symptoms may include irritability, loss of appetite and knawing at the hair surrounding the affected hip. In the course of physical examination manipulating the hip joint will cause pain to the animal. The advanced stages of the disease may result in restricted amplitude of movement, muscular atrophy and fracturing. In humans the clinical signs are similar, although progression of the disease is slower so that it can be diagnosed at an earlier stage. In veterinary medicine the diagnosis is, in the main, based on case history, clinical symptoms, physical examination and certain related procedures such as radiography. The various diagnoses include physical trauma and dislocation of the medial patella. In human medicine many people have been correctly diagnosed. Whatsmore, there is a range of related procedures that are virtually not available to veterinary medicine such as magnetic nuclear resonance, that show up necroses with great clarity before radiography and cintilography do, and is considered... (Complete abstract click electronic access below)
Resumo:
The best way to detect breast cancer is by screening mammography. The mammography equipments are dedicated and require a rigorous quality control in order to have a good quality image and to early detect this disease. The digital equipment is relatively new in the market and there isn’t a national rule for quality control for several types of digital detectors. This study has proposed to compare two different tests manuals for quality control provided by the manufacturers of digital mammography equipments, and also compare them to the “European guidelines for quality assurance in breast cancer screening and diagnosis “(2006). The studied equipments were: Senographe 2000D from General Electric (GE) and the Hologic Selenia Lorad. Both were digital mammography equipments, the GE unit presents an indirect digital system and the other presents a direct digital system. Physical parameters of the image have been studied, such as spatial resolution, contrast resolution, noise, signal-tonoise ratio, contrast-to-noise ratio and modulation transfer function. After that, a study of the importance of quality control and the requirement to implement a Quality Assurance Program has been done. One data collection was done to compare those manual, it was done by checking which tests are indicated and the minimum frequency which they should be conducted in accordance with each manufacturer. The tests were performed by different methodologies and the results were compared. The examined tests were: the breast entrance skin dose, mean glandular dose, contrast-to-noise ratio, signal-to-noise ratio, automatic exposure control and automatic control of density, modulation transfer function, equipment resolution, homogeneity and ghost
Resumo:
Introduction: This study is about the training of community health agents (CHA) in the municipality of Araraquara SP about the topic of sickle cell disease which this purpose is improving the knowledge and care provided by these professionals. Method: Educational intervention with CHA for training in sickle cell disease and using as indicator qualitative and quantitative, a questionnaire to assessment before and after the intervention process. Results: The process of training increased significantly the knowledge of CHA in sickle cell disease. In the questionnaire before, 30% of participants scored above 40 points, while after 97% achieved grades above 40 points. Moreover, it was possible to assessment the development of skills through the solution of a simulated case. Processes interventionist educational are great validity in the process of Pharmaceutical Care Conclusion: The Health Education for CHA may contribute to the improvement of care and treatment of patients with sickle cell disease through humanized health care
Resumo:
This work aims to synthesize the manganese and zinc ferrite, by the polymeric precursor method, in order to obtain materials with appropriate characteristics for the application in medical diagnosis techniques. The manganese and zinc ferrite powders with the composition of Mn(1-x)ZnxFe2O4, where x=0,23, were prepared and calcined in air at different times and temperatures. The X-ray diffraction (XRD) data show that the sample calcined at 400°C crystallize as ferrite (monophase), but in an inverted spinel structure (high content of iron occupying manganese tetrahedral site and manganese occupying the iron octahedral site). The samples calcined at temperatures between 600°C and 900°C shows the secondary phase of hematite and the sample calcined at 1100oC shows to be monophase in ferrite with normal spinel structure. The monophase powders of ferrite showed a reduction in the surface area and an increasing in the pore size for higher calcination temperatures. The magnetic analysis show that the sample calcined at 400°C presents satisfactory magnetization at room temperature, however, it behaves as diamagnetic material at low temperatures (10K). The powder containing hematite, without the partial substitution of iron ions by manganese, showed to have low transition temperature, and consequently low magnetization at room temperature. The hematite, when partially substituted, provides materials with irregular magnetization at the saturation region. The powder calcined at 1100°C shows high magnetization either at room temperature or low temperature (10K)
Resumo:
The Biosusceptometry AC (BAC) is a research tool that has been extensively explored by the group Biomagnetism IBB-UNESP for monitoring of the gastrointestinal tract, its response to a known drug or in vivo performance of solid dosage forms. During this period the BAC, which has the characteristics of high sensitivity and low cost, has been developed primarily for recording signals contraction of activity and traffic human gastrointestinal tract. With the possibility of producing images with this instrumentation, it was possible to evaluate different situations in vitro and in vivo for physiological studies and pharmaceuticals. Considering the good performance of this system to produce planar images, the first aim of the BAC system tomography (TBAC) was to evaluate the system performance of BAC to produce tomographic images of phantoms ferromagnetic for a single channel system. All these applications were only possible because of their sensitivity to materials of high magnetic suscepitibility as ferrite, which allow to produce an electrical signal proportional to the variation of the magnetic flux generated by the presence of magnetic marker next to a first-order gradiometer. Measuring this variation at various points was possible to generate planar images that recently came to be produced in systems with multiple detectors, said multi-channels. From planar images, also producing tomographic images of simulators BAC bars in a system of 13 channels using only the center channel, with good results when applied to simple objects as one and two bars. When testing the resolution of the system with more elaborate forms the quality and resolution of images reconstructed is not satisfactory, which would be solved by increasing the spatial sampling rate and hence the acquisition time. The present system works with an acquisition time of about five hours. Whereas this system will be applied for in vivo experiments, the acquisition time became a ...
Resumo:
Radiography is currently an important method of diagnosis, both medical, dental and veterinary. The image in this type of survey is obtained using an X-ray beam, where the radiologist can possibly view structures of interest. It isn't always possible to get the desired images due to various factors, such as equipment limitations. The Administrative Law 453/98, the State Resolution SS 625/94, and other standards require testing and quality control acceptance limits that guarantee a good performance of the equipment for the security and quality of care, giving service users greater effectiveness in exams. This study were performed in the accompaniment of testing procedures for quality control established by Administrative Law 453/98 in several X-ray equipment to make a comparison and optimization in the descriptions of the procedures used by the Institute for Electrical Energy and the University of São Paulo (IEE / USP / SP).The optimization of the procedures were performed with the aid of a current literature, the Resolution 453/98, State Resolution SS 625/94 and other international standards. On this basis it was possible to observe the importance of regular monitoring of tests for an update, following the technological development of instruments used in the service
Resumo:
Imaging diagnosis is a medical specialty that uses imaging techniques to perform diagnosis. In diagnostic imaging various methods are used such as direct absorption of photons - SPA and DPA, radiographic photometry, the dual-energy radiographic absorptiometry - DEXA, ultrasound, magnetic resonance imaging, computed tomography and optical densitometry in radiographic image. The dog can be considered one of the most widely used animals in the study of bone diseases and searching for a reliable diagnosis, although not an ideal model for the study of osteoporosis, because these animals tend not to develop a decrease in bone mineral density. The objective of this study was to analyze bone density in mongrel dogs from the determination of the variation of density along the radio-ulna bone and also the mean value related to gender, weight and age of individuals. The density analysis carried out showed that for this data set, there is a significant difference in the case of gender and age of the animal and may generalize according to these variables. The only significant difference was found in the weight, which increases bone mass is related to weight gain through the growth of the animal
Resumo:
This project aims the verification of doses in canines and felines to chest and coxal exams due to the transition from screen-film to computed radiography system. It also seeks a possible optimization of the new techniques employed in this new system. The study was carried out in Diagnostic Imaging service in Hospital Veterinário da Faculdade de Medicina Veterinária e Zootecnia da Universidade de São Paulo using a conventional x-ray equipment. Initially, data about the physical characteristics of animals and the technique currently used in computed radiography was collected for each of 80 chest and 16 coxal X-ray examinations. The animals were divided into different groups according to the body weight. For each group, were calculated the averages of each item: thickness of the region to be imaged, voltage, current, exposure time, current-time product, size of film used, presence or absence of bucky and focus (small or large). The techniques have been reproduced in phantoms (representative of the thickness of the animal) in order to collect the air kerma entrance. Based on the average of intermediate size M group (weights less than 5 kg for cats and from 10.1 kg and 20 kg for dogs) analysis of image quality using three devices test patterns were made consisting of the evaluation of spatial resolution, low-contrast resolution and contrast-detail. In general, the results showed the dose animals decreased with the use of computed radiography and was possible to preliminary optimization of some techniques used currently in CR
Resumo:
Computed Radiography (CR) is a term used to describe the system that electronically records a radiographic image. CR systems use receivers or IP (imaging plate) to capture the analog signals and then allow the readers to do the image processing and converted into digital information. With the increasing expansion of the CR for medical diagnostics it is necessary that these systems receive the same type of monitoring related to Quality Control and Acceptance to the conventional processing systems. The current legislation fails to specify the parameters and procedures to be tested, allowing that somehow, some equipment is not fully able to use in clinical routine. In this project we used the standard AAPM Report Number 93, which is already fully established outside the country and displays all test parameters in CR. From there were chosen three types of tests that were performed in a satisfactory sampling of IP´s. With this procedure it was possible to establish which of those IP's should be out of use, which reveals the important purpose of the study, demonstrating the need for Quality Control Testing and Acceptance in Computerized Radiography as soon as possible are included in the legislation regulator in the country
Resumo:
The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public
Resumo:
A proposta desse trabalho surgiu da possibilidade de unir metodologias eficientes para estabelecer valores mais precisos de densitometria óssea. A densidade óssea é um parâmetro biofísico de grande importância experimental e clínica, que permite avaliar o processo de mineralização óssea. O objetivo deste trabalho foi determinar a densidade óssea e o coeficiente de atenuação de massa da radiação gama com o radioisótopo 241Am com fotopico de 59,6 keV em rádios de cães SRD (Sem Raça Definida). Conclui-se a que a densidade média das amostras foi de 1,91 g/cm³ com um desvio padrão de 0,0599. Para o coeficiente de atenuação de massa, o valor médio foi de 0,241 cm2/g, com desvio padrão de 0,0151. Para ambos os parâmetros o coeficiente de variação foi pequeno implicando em uma baixa dispersão. Isso também demonstra que os métodos aplicados foram eficientes e de fácil aplicabilidade
Resumo:
In a globalized world, organizations face an increasingly dynamic, innovative and competitive environment, so that this condition requires continuous adaptation to market developments. Intense competition requires organizations to further improve their performance, making productive efficiency a key factor for survival. A methodology that has added value to the product through a reconfiguration of the production method is the implementation of a management philosophy called Lean Six Sigma. The main objective of this work is, in the light of the Lean Six Sigma philosophy, intervene in a critical-collaborative way to develop procedures for analyzing the profitability of products in a company specializing in steel processing. To achieve this goal, were applied the method of action-research to intervene in a group of professionals for the study of the profitability of products in a auto parts industry. The interaction of practical and theoretical knowledge provided by the action-research allowed the business program was enhanced. The procedures proposed in this study were able to identify the current profitability of the product, the main causes of inefficiency and productive for solutions to reduce production inefficiencies, when the productive systems planned and actual production system were compared. The results indicate that current profitability of -3%, while the parameter provided during budget was 10%. Thus, it is concluded that the low profitability of the products may compromise the company's financial results and affect their competitiveness in the market. To address this problem, the Lean Six Sigma presents itself as a versatile and high applicability philosophy, providing relevant results for characterization and troubleshooting. It was also observed that the evidence presented in this paper can be adapted to other companies in the metal auto parts segment to identify and recover the profitability of products