939 resultados para Platelet adhesion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effects of the platelet-rich plasma (PRP) when used in combination with autogenous bone graft and bioabsorbable membrane (Resolut® ) in the treatment of Class  III furcation defects in dogs. Material and method: Class III furcation defects (5 mm in height and in depth) were surgically created in the mandibular third premolars of five mongrel dogs. After nine weeks, the lesions were treated with scaling and root planning and each defect received one of the following treatments: autogenous bone graft + membrane (group C) or PRP + autogenous bone graft + membrane (group T). After a healing period of 90 days, the animals were sacrificed. Routine histological processing and staining with hematoxilyn and eosin and Masson trichrome were performed and a histomorphometric analysis determined the effect of the treatments on periodontal tissue regereneration. Data were analyzed by Hotelling’s T-squared (p < 0.05). Result: No statistically significant difference between C and T groups was observed by the histomorphometric analysis of the furcation area. Both treatment groups demonstrated similar regenerative results with the furcation defects partially filled and periodontal regeneration limited to the experimental notches of the lesions. (p > 0.05). Conclusion: According to the present results, PRP does not enhance the periodontal regeneration in class III furcation defects treated with autogenous bone graft and bioabsorbable membrane.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: The role of saliva on Candida adhesion to biomaterials has not been clearly defined. The present study investigates whether different periods of preconditioning with saliva would influence the adhesion of Candida albicans to a denture base resin. Methods: Ninety samples of acrylic resin with smooth surfaces were made and then divided into five groups: one control without saliva, and four experimental groups conditioned in saliva for periods of 30 min, 1, 3, or 12 h. Candida adhesion was evaluated by crystal violet staining and 2,3-bis(2-methoxy-4-nitro-5-sulfophenyl)-5-([phenylamino] carbonyl)-2H-tetrazolium-hydroxide assay. Results: The one-way analysis of variance revealed that there were no significant differences among the mean number of adherent cells or among the mean absorbance for all groups. No significant correlation was found between the two methods used for assessing Candida albicans adhesion. Conclusion: The different periods of preconditioning with saliva had no significant influence on the adhesion of Candida albicans to the denture base acrylic resin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective In studies on Candida albicans adhesion to surfaces, diverse protocols have been used for collection and preparation of saliva samples. Thus, this study investigated whether variations in the centrifugation parameters and number of donors of saliva would influence the adhesion of C. albicans to a denture base resin. Methods Resin acrylic samples (n = 72) were made and then divided into four groups: (a) control – specimens were left without preconditioning in saliva; (b) three experimental groups, in which the specimens were preconditioned with saliva collected from 15 volunteers and centrifuged at 12 000 g for 5 min (G1); from 15 volunteers and centrifuged at 18 000 g for 30 min (G2); and from one volunteer and centrifuged at 12 000 g for 5 min (G3). Candida adhesion was evaluated by both the 2,3-bis(2-methoxy-4-nitro-5-sulfophenyl)-5-[(phenylamino) carbonyl]-2H-tetrazolium hydroxide (XTT) reduction method and crystal violet staining. Data were analyzed by one-way analyses of variance (P = 0.05). Results For XTT reduction assay, groups G2, G3, and control were not significantly different, whereas group G1 showed significantly higher absorbance value than control. For crystal violet staining there were no significant differences among all groups. Conclusion Variations in the centrifugation parameters and number of donors of saliva may influence C. albicans adhesion to denture base resins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical use of platelet-rich plasma (PRP) is based on the increase in the concentration of growth factors and in the secretion of proteins which are able to maximize the healing process at the cellular level. Since PRP is an autologous biologic material, it involves a minimum risk of immune reactions and transmission of infectious and contagious diseases, and it has been widely used for the recovery of musculoskeletal lesions. Despite the great potential for applicability, the implementation of the therapeutic employment of PRP as a clinical alternative has become difficult, due to the lack of studies related to the standardization of the techniques and/or insufficient description of the adopted procedures. Therefore, it is required establish standard criteria to be followed for obtaining a PRP of high quality, as well as a larger number of studies which should establish the proper concentration of platelets for the different clinical conditions. In this context, the purpose of this review is to discuss some methodological aspects used for achieving the PRP, as well as to discuss the bioactive properties of PRP, and to point out its therapeutic use in different fields of regenerative medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To evaluate the adherence of Streptococcus mutans to the surface of the amalgam and copper/aluminum alloy samples and also evaluate the release of metallic ions. METHODS: The prepared medium was changed every 72 h and analyzed by atomic absorption spectrophotometer. Samples were removed from the prepared medium at 15, 30, 48 and 60 days. RESULTS: The result shows that ions released were statistically different among all groups, and so were both biofilm and pits formation and the corrosion induced by the S. mutans in both types of samples. SEM observation of the samples immersed in the prepared medium with S. mutans showed adherence of microorganisms on the whole surface, in all groups. CONCLUSIONS: The S. mutans adhere to both amalgam and copper/aluminum alloy causing corrosion of those restorations. S. mutans produced a greater ions release in Cu/Al alloy; in amalgam, the ions release was not influenced by exposure to S. mutans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine whether universal primers alone can deliver similar levels of adhesion of resin cement to zirconia ceramic when compared to their application in conjunction with airborne-particle abrasion.Materials and Methods: Sintered zirconia blocks (N = 160) (Lava, 3M ESPE), (5.25 x 5.25 x 3 mm(3)) were embedded in acrylic resin, polished, and randomly distributed into 16 groups (n = 10 per group), according to the factors "universal primer" (8 levels) and "air-particle abrasion" (2 levels): 1. ctr: control, without application of a universal primer; 2. AP: Alloy Primer; 3. MP: Monobond Plus; 4. MZP: Metal Zirconia Primer; 5. MZ: MZ Primer; 6. Sg: Signum Zirconia Bond; 7. SbU: Singlebond Universal; 8. ZP: Z Prime Plus. The universal primers were also used after air abrasion (A) of zirconia to form the following 8 groups: Ctr-A, AP-A, MP-A, MZP-A, MZ-A, Sg-A, SbU-A, and ZP-A. After ultrasonic cleaning, air abrasion was performed using Al2O3 particles (110 mu m, 2.5 bar, 20 s at 10 mm) in a chairside air-abrasion device. After ultrasonic cleaning again, universal primers were applied according to each manufacturer's recommendation. The resin cement (RelyX ARC, 3M ESPE) was built up incrementally and photo-polymerized on the zirconia surface using a silicone mold (empty set = 3.5, height = 3 mm). All specimens were stored in distilled water (60 days at 37 degrees C) and then subjected to shear bond strength testing (SBS) in a universal testing machine (1 mm/min). On a separate set of zirconia specimens, contact angle measurements were made using the sessile drop technique with a goniometer after the application of universal primers on control and air-abraded zirconia surfaces. Data (MPa) were analyzed using one-way ANOVA, Tukey's test, and Student's t-test (alpha = 0.05).Results: When universal primers were used alone, SbU presented significantly higher mean SBS (19.5 +/- 5.8) that did the other primers (0 to 9.9 +/- 6.6) (p = 0.001). When air abraded, the groups AP-A (14.1 +/- 6.1), MP-A (15.9 +/- 5.4), ZP-A (16.9 +/- 7.3), SG-A (19.1 +/- 2.1), SbU-A (12 +/- 1.5) showed significant differences (p = 0.03). Adhesive performance of all universal primers was enhanced after air abrasion, with the exception of the SbU and MZ primers. After air abrasion, contact angle measurements were lower for the each primer (without air abrasion: 28.9 to 83.9; with air abrasion: 27.1 to 63.0), except for MZP.Conclusion: Air abrasion with 110 mu m Al2O3 followed by universal primer application increased the bond strength of tested resin cement to zirconia, with the exception of SbU and MZ.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare the quantity and quality of platelets in platelet-rich plasma (PRP) samples prepared using either the single- or the double-centrifugation protocol. Ten adult white New Zealand rabbits were used. Ten ml of blood were drawn from each animal via cardiac puncture. Each blood sample was divided into two equal parts for PRP preparation: 5 ml of blood were centrifuged according to a single-centrifugation protocol (Group I), and 5 ml were centrifuged according to a double-centrifugation protocol (Group II). Manual platelet counts were performed on the whole blood and PRP samples of each group. Smears were also done on all samples in order to see the morphology of the platelets. The data obtained in the manual platelet count were submitted to statistical analysis (repeated measures ANOVA, Tukey, P<.05). The average whole blood platelet count was 446,389/μl. The PRP samples in Group II presented an average platelet amount significantly higher than that of Group I (1,986,875 ± 685,020/μl and 781,875 ± 217,693/μl, respectively). The PRP smears from Group II were the only one to present platelets with altered morphology (75% of the smears). A few lymphocytes with increased cytoplasm were observed in the PRP smears of both Groups I (25% of the smears) and II (62.5% of the smears). Within the limits of this study, it can be concluded that the double-centrifugation protocol resulted in higher platelet concentrations than did the single-centrifugation protocol. However, the double-centrifugation protocol caused alterations in platelet morphology and was more sensitive to small processing errors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the associations of HPA polymorphisms -1, -3, and -5 with HIV/HCV coinfection were included in this study 60 HIV/HCV-coinfected patients from the Sao Paulo State health service centers. Data reported by Verdichio-Moraes et al. (2009: J. Med Virol 81:757-759) were used as the non-infected and HCV monoinfected groups. Human Platelet Polymorphism genotyping was performed in 60 Patients co-infected with HIV/HCV by PCR-SSP or PCR-RFLP. HIV subtyping and HCV genotyping was performed by RT-PCR followed sequencing. The data analyses were performed using the χ2 test or Fisher's Exact Test and the logistic regression model. Patients coinfected with HIV/HCV presented HCV either genotype 1 (78.3%) or non-1 (21.7%) and HIV either subtype B (85.0%) or non-B (15%). The Human Platelet Polymorphism-1a/1b genotype was more frequent (P < 0.05) in HIV/HCV coinfection than in HCV monoinfection and the allelic frequency of Human Platelet Polymorphism-5b in the Patients coinfected with HIV/HCV was higher (P < 0.05) than in HCV monoinfected cases and non-infected individuals. These data suggest that the presence of specific HPA allele on platelets could favor the existence of coinfection. On the other hand, Human Platelet Polymorphism-5a/5b was more frequent (P < 0.05) in HIV/HCV coinfected and HCV monoinfected groups than in the non-infected individuals, suggesting that this platelet genotype is related to HCV infection, regardless of HIV presence. Results suggest that the Human Platelet Polymorphism profile in HIV/HCV coinfected individuals differs from the one of both HCV monoinfected and non-infected population. So, the Human Platelet Polymorphism can be a genetic marker associated with HIV/HCV coinfection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the influence of different forms of heat treatment on a pre-hydrolyzed silane to improve the adhesion of phosphate monomer-based (MDP) resin cement to glass ceramic. Resin and feldspathic ceramic blocks (n=48, n=6 for bond test, n=2 for microscopy) were randomly divided into 6 groups and subject to surface treatments: G1: Hydrofluoric acid (HF) 9.6% for 20 s + Silane + MDP resin cement (Panavia F); G2: HF 9.6% for 20 s + Silane + Heat Treatment (oven) + Panavia F; G3: Silane + Heat Treatment (oven) + Panavia F; G4: HF 9.6% for 20 s + Silane + Heat Treatment (hot air) + Panavia F; G5: Silane + Heat Treatment (hot air) + Panavia F; G6: Silane + Panavia F. Microtensile bond strength (MTBS) test was performed using a universal testing machine (1 mm/min). After debonding, the substrate and adherent surfaces were analyzed using stereomicroscope and scanning electron microscope (SEM) to categorize the failure types. Data were analyzed statistically using two-way test ANOVA and Tukey's test (=0.05). Heat treatment of the silane containing MDP, with prior etching with HF (G2: 13.15 ± 0.89a; G4: 12.58 ± 1.03a) presented significantly higher bond strength values than the control group (G1: 9.16 ± 0.64b). The groups without prior etching (G3: 10.47 ± 0.70b; G5: 9.47 ± 0.32b) showed statistically similar bond strength values between them and the control group (G1). The silane application without prior etching and heat treatment resulted in the lowest mean bond strength (G6: 8.05 ± 0.37c). SEM analysis showed predominantly adhesive failures and EDS analysis showed common elements of spectra (Si, Na, Al, K, O, C) characterizing the microstructure of the glass-ceramic studied. Heat treatment of the pre-hydrolyzed silane containing MDP in an oven at 100 °C for 2 min or with hot air application at 50 ± 5 ºC for 1 min, was effective in increasing the bond strength values between the ceramic and resin cement containing MDP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the efficacy of platelet-rich plasma regarding healing, pain and hemostasis after total knee arthroplasty, by means of a blinded randomized controlled and blinded clinical study. Forty patients who were going to undergo implantation of a total knee prosthesis were selected and randomized. In 20 of these patients, platelet-rich plasma was applied before the joint capsule was closed. The hemoglobin (mg/dL) and hematocrit (%) levels were assayed before the operation and 24 and 48 h afterwards. The Womac questionnaire and a verbal pain scale were applied and knee range of motion measurements were made up to the second postoperative month. The statistical analysis compared the results with the aim of determining whether there were any differences between the groups at each of the evaluation times. The hemoglobin (mg/dL) and hematocrit (%) measurements made before the operation and 24 and 48 h afterwards did not show any significant differences between the groups (p > 0.05). The Womac questionnaire and the range of motion measured before the operation and up to the first two months also did not show any statistical differences between the groups (p > 0.05). The pain evaluation using the verbal scale showed that there was an advantage for the group that received platelet-rich plasma, 24 h, 48 h, one week, three weeks and two months after the operation (p < 0.05). In the manner in which the platelet-rich plasma was used, it was not shown to be effective for reducing bleeding or improving knee function after arthroplasty, in comparison with the controls. There was an advantage on the postoperative verbal pain scale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prevention of adhesion of Candida cells to acrylic surfaces can be regarded as an alternative to prevent denture stomatitis. The use of quorum sensing molecules, such as tyrosol, could potentially interfere with the adhesion process. Therefore, the aim of this study was to assess the effect of tyrosol on adhesion of single and mixed cultures of Candida albicans and Candida glabrata to acrylic resin surfaces. Tyrosol was diluted in each yeast inoculum (10(7) cells/ml in artificial saliva) at 25, 50, 100, and 200 mM. Then, each dilution was added to wells of 24-well plates containing the acrylic specimens, and the plates were incubated at 37°C for 2 h. After, the effect of tyrosol was determined by total biomass quantification, metabolic activity of the cells and colony-forming unit counting. Chlorhexidine gluconate (CHG) was used as a positive control. Data were analyzed using analysis of variance (ANOVA) and the Holm-Sidak post hoc test (α = 0.05). The results of total biomass quantification and metabolic activity revealed that the tyrosol promoted significant reductions (ranging from 22.32 to 86.16%) on single C. albicans and mixed cultures. Moreover, tyrosol at 200 mM and CHG significantly reduced (p < 0.05) the number of adhered cells to the acrylic surface for single and mixed cultures of both species, with reductions ranging from 1.74 to 3.64-log10. In conclusion, tyrosol has an inhibitory effect on Candida adhesion to acrylic resin, and further investigations are warranted to clarify its potential against Candida infections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effects of homogenous demineralized dentin matrix (HDDM) slices and platelet-rich plasma (PRP) in surgical defects created in the parietal bones of alloxan-induced diabetic rabbits, treated with a guided bone regeneration technique. Biochemical, radiographic, and histological analyses were performed. Sixty adult New Zealand rabbits were divided into five groups of 12: normoglycaemic (control, C), diabetic (D), diabetic with a PTFE membrane (DM), diabetic with a PTFE membrane and HDDM slices (DM-HDDM), and diabetic with PTFE membrane and PRP (DM-PRP). The quantity and quality of bone mass was greatest in the DM-HDDM group (respective radiographic and histological analyses: at 15 days, 71.70±16.50 and 50.80±1.52; 30 days, 62.73±16.51 and 54.20±1.23; 60 days, 63.03±11.04 and 59.91±3.32; 90 days, 103.60±24.86 and 78.99±1.34), followed by the DM-PRP group (respective radiographic and histological analyses: at 15 days 23.00±2.74 and 20.66±7.45; 30 days 31.92±6.06 and 25.31±5.59; 60 days 25.29±16.30 and 46.73±2.07; 90 days 38.10±14.04 and 53.38±9.20). PRP greatly enhanced vascularization during the bone repair process. Abnormal calcium metabolism was statistically significant in the DM-PRP group (P<0.001) for all four time intervals studied, especially when compared to the DM-HDDM group. Alkaline phosphatase activity was significantly higher in the DM-HDDM group (P<0.001) in comparison to the C, D, and DM-PRP groups, confirming the findings of intense osteoblastic activity and increased bone mineralization. Thus, HDDM promoted superior bone architectural microstructure in bone defects in diabetic rabbits due to its effective osteoinductive and osteoconductive activity, whereas PRP stimulated angiogenesis and red bone marrow formation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)