995 resultados para Plasma mixture
Resumo:
The new-generation nebulizers are commonly used for the administration of salbutamol in mechanically ventilated patients. The different modes of administration and new devices have not been compared. We developed a liquid chromatography-tandem mass spectrometry method for the determination of concentrations as low as 0.05 ng/mL of salbutamol, corresponding to the desired plasma concentration after inhalation. Salbutamol quantification was performed by reverse-phase HPLC. Analyte quantification was performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection ESI in the positive mode. The method was validated over concentrations ranging from 0.05 to 100 ng/mL in plasma and from 0.18 to 135 ng/mL in urine. The method is precise, with mean inter-day coefficient of variation (CV%) within 3.1-8.3% in plasma and 1.3-3.9% in urine, as well as accurate. The proposed method was found to reach the required sensitivity for the evaluation of different nebulizers as well as nebulization modes. The present assay was applied to examine whether salbutamol urine levels, normalized with the creatinine levels, correlated with the plasma concentrations. A suitable, convenient and noninvasive method of monitoring patients receiving salbutamol by mechanical ventilation could be implemented. Copyright © 2011 John Wiley & Sons, Ltd.
Resumo:
In 63 patients with histologically proved gynecologie carcinoma, circulating carcinoembryonic antigen (CEA) was determined by radioimmunoassay before and at two intervals after treatment. Thirty-one patients of 63 had CEA values over 2.5 ng. per milliliter before treatment. In general, the CEA levels were low compared to those found in endodermal carcinoma. The percentage of elevated CEA values was slightly higher in cases of carcinoma of the cervix and corpus uteri than in those of carcinoma of the ovary. All patients with CEA levels greater than 2.5 ng. per milliliter treated by complete surgical resection of tumor showed a drop of CEA levels to below 2.5 ng. per milliliter seven weeks after operation. In contrast, patients with palliative therapy showed no change in CEA values. About half of the patients treated with a complete course of internal and external radiotherapy showed a drop of CEA levels to below 2.5 ng. per milliliter, whereas the other patients showed fluctuating CEA values. No correlation between clinical status and evolution of CEA levels in these patients could be drawn at the present time. The CEA test seems to be of little value for the earl of diagnosis of gynecologie carcinoma but appears to be interesting for the evaluation of therapy and the follow-up of patients with diagnosed cases.
Resumo:
The role of busulfan (Bu) metabolites in the adverse events seen during hematopoietic stem cell transplantation and in drug interactions is not explored. Lack of availability of established analytical methods limits our understanding in this area. The present work describes a novel gas chromatography-tandem mass spectrometric assay for the analysis of sulfolane (Su) in plasma of patients receiving high-dose Bu. Su and Bu were extracted from a single 100 μL plasma sample by liquid-liquid extraction. Bu was separately derivatized with 2,3,5,6-tetrafluorothiophenolfluorinated agent. Mass spectrometric detection of the analytes was performed in the selected reaction monitoring mode on a triple quadrupole instrument after electronic impact ionization. Bu and Su were analyzed with separate chromatographic programs, lasting 5 min each. The assay for Su was found to be linear in the concentration range of 20-400 ng/mL. The method has satisfactory sensitivity (lower limit of quantification, 20 ng/mL) and precision (relative standard deviation less than 15 %) for all the concentrations tested with a good trueness (100 ± 5 %). This method was applied to measure Su from pediatric patients with samples collected 4 h after dose 1 (n = 46), before dose 7 (n = 56), and after dose 9 (n = 54) infusions of Bu. Su (mean ± SD) was detectable in plasma of patients 4 h after dose 1, and higher levels were observed after dose 9 (249.9 ± 123.4 ng/mL). This method may be used in clinical studies investigating the role of Su on adverse events and drug interactions associated with Bu therapy.
Resumo:
A gas chromatographic-mass spectrometric (GC-MS) method has been developed, for the determination of trimipramine (TRI), desmethyltrimipramine (DTRI), didesmethyltrimipramine (DDTRI), 2-hydroxytrimipramine (2-OH-TRI) and 2-hydroxydesmethyltrimipramine (2-OH-DTRI). The method includes two derivatization steps with trifluoroacetic acid anhydride and N-methyl-N-(tert.-butyldimethyl silyl)trifluoroacetamide and the use of an SE-54 capillary silica column. The limits of quantitation were found to be 2 ng/ml for DTRI and 4 ng/ml for all other substances. Besides, methods have been optimized for the hydrolysis of the glucuronic acid conjugated metabolites. This specific detection method is useful, as polymedication is a usual practice in clinical situations, and its sensitivity allows its use for single-dose pharmacokinetic studies.
Resumo:
Raltegravir (RAL), maraviroc (MVC), darunavir (DRV), and etravirine (ETV) are new antiretroviral agents with significant potential for drug interactions. This work describes a sensitive and accurate liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of plasma drug levels. Single-step extraction of RAL, MVC, DRV, ETV and RTV from plasma (100 microl) is performed by protein precipitation using 600 microl of acetonitrile, after the addition of 100 microl darunavir-d(9) (DRV-d(9)) at 1000 ng/ml in MeOH/H(2)O 50/50 as internal standard (I.S.). The mixture is vortexed, sonicated for 10 min, vortex-mixed again and centrifuged. An aliquot of supernatant (150 microl) is diluted 1:1 with a mixture of 20 mM ammonium acetate/MeOH 40/60 and 10 microl is injected onto a 2.1 x 50 mm Waters Atlantis-dC18 3 microm analytical column. Chromatographic separations are performed using a gradient program with 2 mM ammonium acetate containing 0.1% formic acid and acetonitrile with 0.1% formic acid. Analytes quantification is performed by electrospray ionisation-triple quadrupole mass spectrometry using the selected reaction monitoring detection in the positive mode. The method has been validated over the clinically relevant concentrations ranging from 12.5 to 5000 ng/ml, 2.5 to 1000 ng/ml, 25 to 10,000 ng/ml, 10 to 4000 ng/ml, and 5 to 2000 ng/ml for RAL, MRV, DRV, ETV and RTV, respectively. The extraction recovery for all antiretroviral drugs is always above 91%. The method is precise, with mean inter-day CV% within 5.1-9.8%, and accurate (range of inter-day deviation from nominal values -3.3 to +5.1%). In addition our method enables the simultaneous assessment of raltegravir-glucuronide. This is the first analytical method allowing the simultaneous assay of antiretroviral agents targeted to four different steps of HIV replication. The proposed method is suitable for the Therapeutic Drug Monitoring Service of these new regimen combinations administered as salvage therapy to patients having experienced treatment failure, and for whom exposure, tolerance and adherence assessments are critical.
Resumo:
The antifungal agent fluconazole (FLC) is widely used in clinical practice. Monitoring FLC levels is useful in complicated clinical settings and in experimental infection models. A bioassay using Candida pseudotropicalis, a simple and cost-effective method, is validated only for FLC levels ranging from 5 to 40 mg/liter. An extension of the analytical range is needed to cover most yeast MICs. A new bioassay in RPMI agar containing methylene blue was developed using C. albicans DSY1024, a mutant rendered hypersusceptible to FLC constructed by the deletion of the multidrug efflux transporter genes CDR1, CDR2, CaMDR1, and FLU1. Reproducible standard curves were obtained with FLC concentrations in plasma ranging from 1 to 100 mg/liter (quadratic regression coefficient > 0.997). The absolute sensitivity was 0.026 microg of FLC. The method was internally validated according to current guidelines for analytical method validation. Both accuracy and precision lied in the required +/-15% range. FLC levels measured by bioassay and by high-performance liquid chromatography (HPLC) performed with 62 plasma samples from humans and rats showed a strong correlation (coefficients, 0.979 and 0.995, respectively; percent deviations of bioassay from HPLC values, 0.44% +/- 15.31% and 2.66% +/- 7.54%, respectively). In summary, this newly developed bioassay is sensitive, simple, rapid, and inexpensive. It allows nonspecialized laboratories to determine FLC levels in plasma to within the clinically relevant concentration range and represents a useful tool for experimental treatment models.
Genome-wide association study identifies loci influencing concentrations of liver enzymes in plasma.
Resumo:
Concentrations of liver enzymes in plasma are widely used as indicators of liver disease. We carried out a genome-wide association study in 61,089 individuals, identifying 42 loci associated with concentrations of liver enzymes in plasma, of which 32 are new associations (P = 10(-8) to P = 10(-190)). We used functional genomic approaches including metabonomic profiling and gene expression analyses to identify probable candidate genes at these regions. We identified 69 candidate genes, including genes involved in biliary transport (ATP8B1 and ABCB11), glucose, carbohydrate and lipid metabolism (FADS1, FADS2, GCKR, JMJD1C, HNF1A, MLXIPL, PNPLA3, PPP1R3B, SLC2A2 and TRIB1), glycoprotein biosynthesis and cell surface glycobiology (ABO, ASGR1, FUT2, GPLD1 and ST3GAL4), inflammation and immunity (CD276, CDH6, GCKR, HNF1A, HPR, ITGA1, RORA and STAT4) and glutathione metabolism (GSTT1, GSTT2 and GGT), as well as several genes of uncertain or unknown function (including ABHD12, EFHD1, EFNA1, EPHA2, MICAL3 and ZNF827). Our results provide new insight into genetic mechanisms and pathways influencing markers of liver function.
Resumo:
Biomaterials releasing silver (Ag) are of interest because of their ability to inhibit pathogenic bacteria including antibiotic-resistant strains. In order to investigate the potential of nanometre-thick Ag polymer (Ag/amino-hydrocarbon) nanocomposite plasma coatings, we studied a comprehensive range of factors such as the plasma deposition process and Ag cation release as well as the antibacterial and cytocompatible properties. The nanocomposite coatings released most bound Ag within the first day of immersion in water yielding an antibacterial burst. The release kinetics correlated with the inhibitory effects on the pathogens Pseudomonas aeruginosa or Staphylococcus aureus and on animal cells that were in contact with these coatings. We identified a unique range of Ag content that provided an effective antibacterial peak release, followed by cytocompatible conditions soon thereafter. The control of the in situ growth conditions for Ag nanoparticles in the polymer matrix offers the possibility to produce customized coatings that initially release sufficient quantities of Ag ions to produce a strong adjacent antibacterial effect, and at the same time exhibit a rapidly decaying Ag content to provide surface cytocompatibility within hours/days. This approach seems to be favourable with respect to implant surfaces and possible Ag-resistance/tolerance built-up.
Resumo:
Thioridazine is a commonly prescribed phenothiazine drug administered as a racemate and it is believed that its antipsychotic effect is mainly associated with (R)-thioridazine. A method based on high-performance liquid chromatography has been developed for the determination of the enantiomers of thioridazine and thioridazine 2-sulfone (THD 2-SO2 or sulforidazine) and of the enantiomers of the diastereoisomeric pairs of thioridazine 2-sulfoxide (THD 2-SO or mesoridazine) and thioridazine 5-sulfoxide (THD 5-SO) in the plasma of thioridazine-treated patients. The method involves sequential achiral and chiral HPLC. The limits of quantitation for total (R) + (S) concentrations were found to be 15 ng/ml for thioridazine and 5 ng/ml for its metabolites. The limits for the determination of the (R)/(S) ratios were found to be 60 ng/ml for racemic THD and 10 ng/ml for racemic THD 2-SO, THD 2-SO2, THD 5-SO (FE) and THD 5-SO (SE). The method has been used to determine the concentrations of the enantiomers of thioridazine and of its metabolites in the plasma of a patient treated with 100 mg of racemic thioridazine hydrochloride per os per day for 14 days. The results show a high enantioselectivity in the metabolism of this drug: the (R)/(S) ratios for THD, THD 2-SO (FE), THD 2-SO (SE), THD 2-SO2, THD 5-SO (FE) and THD 5-SO (SE) were found to be 3.90, 1.22, 6.10, 4.10, 0.09 and 28.0, respectively.
Resumo:
Valganciclovir and ganciclovir are widely used for the prevention of cytomegalovirus (CMV) infection in solid organ transplant recipients, with a major impact on patients' morbidity and mortality. Oral valganciclovir, the ester prodrug of ganciclovir, has been developed to enhance the oral bioavailability of ganciclovir. It crosses the gastrointestinal barrier through peptide transporters and is then hydrolysed into ganciclovir. This review aims to describe the current knowledge of the pharmacokinetic and pharmacodynamic characteristics of this agent, and to address the issue of therapeutic drug monitoring. Based on currently available literature, ganciclovir pharmacokinetics in adult solid organ transplant recipients receiving oral valganciclovir are characterized by bioavailability of 66 +/- 10% (mean +/- SD), a maximum plasma concentration of 3.1 +/- 0.8 mg/L after a dose of 450 mg and of 6.6 +/- 1.9 mg/L after a dose of 900 mg, a time to reach the maximum plasma concentration of 3.0 +/- 1.0 hours, area under the plasma concentration-time curve values of 29.1 +/- 5.3 mg.h/L and 51.9 +/- 18.3 mg.h/L (after 450 mg and 900 mg, respectively), apparent clearance of 12.4 +/- 3.8 L/h, an elimination half-life of 5.3 +/- 1.5 hours and an apparent terminal volume of distribution of 101 +/- 36 L. The apparent clearance is highly correlated with renal function, hence the dosage needs to be adjusted in proportion to the glomerular filtration rate. Unexplained interpatient variability is limited (18% in apparent clearance and 28% in the apparent central volume of distribution). There is no indication of erratic or limited absorption in given subgroups of patients; however, this may be of concern in patients with severe malabsorption. The in vitro pharmacodynamics of ganciclovir reveal a mean concentration producing 50% inhibition (IC(50)) among CMV clinical strains of 0.7 mg/L (range 0.2-1.9 mg/L). Systemic exposure of ganciclovir appears to be moderately correlated with clinical antiviral activity and haematotoxicity during CMV prophylaxis in high-risk transplant recipients. Low ganciclovir plasma concentrations have been associated with treatment failure and high concentrations with haematotoxicity and neurotoxicity, but no formal therapeutic or toxic ranges have been validated. The pharmacokinetic parameters of ganciclovir after valganciclovir administration (bioavailability, apparent clearance and volume of distribution) are fairly predictable in adult transplant patients, with little interpatient variability beyond the effect of renal function and bodyweight. Thus ganciclovir exposure can probably be controlled with sufficient accuracy by thorough valganciclovir dosage adjustment according to patient characteristics. In addition, the therapeutic margin of ganciclovir is loosely defined. The usefulness of systematic therapeutic drug monitoring in adult transplant patients therefore appears questionable; however, studies are still needed to extend knowledge to particular subgroups of patients or dosage regimens.
Resumo:
Newly synthesized glucose transporter 4 (GLUT4) enters into the insulin-responsive storage compartment in a process that is Golgi-localized γ-ear-containing Arf-binding protein (GGA) dependent, whereas insulin-stimulated translocation is regulated by Akt substrate of 160 kDa (AS160). In the present study, using a variety of GLUT4/GLUT1 chimeras, we have analyzed the specific motifs of GLUT4 that are important for GGA and AS160 regulation of GLUT4 trafficking. Substitution of the amino terminus and the large intracellular loop of GLUT4 into GLUT1 (chimera 1-441) fully recapitulated the basal state retention, insulin-stimulated translocation, and GGA and AS160 sensitivity of wild-type GLUT4 (GLUT4-WT). GLUT4 point mutation (GLUT4-F5A) resulted in loss of GLUT4 intracellular retention in the basal state when coexpressed with both wild-type GGA and AS160. Nevertheless, similar to GLUT4-WT, the insulin-stimulated plasma membrane localization of GLUT4-F5A was significantly inhibited by coexpression of dominant-interfering GGA. In addition, coexpression with a dominant-interfering AS160 (AS160-4P) abolished insulin-stimulated GLUT4-WT but not GLUT4-F5A translocation. GLUT4 endocytosis and intracellular sequestration also required both the amino terminus and large cytoplasmic loop of GLUT4. Furthermore, both the FQQI and the SLL motifs participate in the initial endocytosis from the plasma membrane; however, once internalized, unlike the FQQI motif, the SLL motif is not responsible for intracellular recycling of GLUT4 back to the specialized compartment. Together, we have demonstrated that the FQQI motif within the amino terminus of GLUT4 is essential for GLUT4 endocytosis and AS160-dependent intracellular retention but not for the GGA-dependent sorting of GLUT4 into the insulin-responsive storage compartment.
Resumo:
Conjugated linoleic acid (CLA) has been reported to exert beneficial physiological effects on body composition and the immune system. However, little information is available on the influence of CLA on immune function during early life periods. The present study evaluates the effect of feeding an 80:20 mixture of cis-9,trans-11- and trans-10,cis-12-CLA isomers duringgestation, suckling and early infancy on the systemic and mucosal immune responses of Wistar rats at three different time points: at the end of the suckling period (21-day-old rats), in early infancy (28-day-old rats), and later in life (adulthood). Cis-9,trans-11- and trans-10,cis-12-CLA isomers were detected in the milk of CLA-fed dams and in the plasma of all CLA-supplemented pups, and the highest content was achieved in those rats supplemented over the longest period. Dietary supplementation with that CLA mix enhances the systemic production of the main in vivo and ex vivo immunoglobulin (Ig) isotypes in 21- and 28-day-old rats. Moreover, CLA supplementation during suckling and early infancy also enhances the humoral immune defenses at intestinal level, by means of mucosal IgA increase, whereas down-regulates thesystemic lymphoproliferative response. Finally, we described herein how feeding a diet enriched with the same isomer mix of cis9,trans11- and trans10,cis12-CLA from gestation to adulthood improves the capacity of adult rats to achieve a specific systemic and mucosal immune responses. All these data support the immunomodulatory effects of dietary supplementation of CLA, particularly of the cis9,trans11-CLA isomer, during early stages of life on immune system development, as well as the long-term effects on the specific immune response in adult age.
Resumo:
OBJECTIVE: The major source of hemolysis during cardiopulmonary bypass remains the cardiotomy suction and is primarily due to the interaction between air and blood. The Smart suction system involves an automatically controlled aspiration designed to avoid the mixture of blood with air. This study was set-up to compare this recently designed suction system to a Cell Saver system in order to investigate their effects on blood elements during prolonged intrathoracic aspiration. METHODS: In a calf model (n=10; mean weight, 69.3+/-4.5 kg), a standardized hole was created in the right atrium allowing a blood loss of 100 ml/min, with a suction cannula placed into the chest cavity into a fixed position during 6 h. The blood was continuously aspirated either with the Smart suction system (five animals) or the Cell Saver system (five animals). Blood samples were taken hourly for blood cell counts and biochemistry. RESULTS: In the Smart suction group, red cell count, plasma protein and free hemoglobin levels remained stable, while platelet count exhibited a significant drop from the fifth hour onwards (prebypass: 683+/-201*10(9)/l, 5 h: 280+/-142*10(9)/l, P=0.046). In the Cell Saver group, there was a significant drop of the red cell count from the third hour onwards (prebypass: 8.6+/-0.9*10(12)/l, 6 h: 6.3+/-0.4*10(12)/l, P=0.02), of the platelet count from the first hour onwards (prebypass: 630+/-97*10(9)/l, 1 h: 224+/-75*10(9)/l, P<0.01), and of the plasma protein level from the first hour onwards (prebypass: 61.7+/-0.6 g/l, 1 h: 29.3+/-9.1 g/l, P<0.01). CONCLUSIONS: In this experimental set-up, the Smart suction system avoids damage to red cells and affects platelet count less than the Cell Saver system which induces important blood cell destruction, as any suction device mixing air and blood, as well as severe hypoproteinemia with its metabolic, clotting and hemodynamic consequences.
Resumo:
This literature review focuses on factors influencing drying shrinkage of concrete. Although the factors are normally interrelated, they can be categorized into three groups: paste quantity, paste quality, and other factors.