769 resultados para PES
Resumo:
Several countries have invested in technologies for Smart Grids. Among such protocols designed cover this area, highlights the DNP3 (Distributed Network Protocol version 3). Although the DNP3 be developed for operation over the serial interface, there is a trend in the literature to the use of other interfaces. The Zigbee wireless interface has become more popular in the industrial applications. In order to study the challenges of integrating of these two protocols, this article is presented the analysis of DNP3 protocol stack through state machines The encapsulation of DNP3 messages in P2P (point-to-point) ZigBee Network, may assist in the discovery and solution of failures of availability and security of this integration. The ultimate goal is to merge the features of DNP3 and Zigbee stacks, and display a solution that provides the benefits of wireless environment, without impairment of security required for Smart Grid applications.
Resumo:
Usually, ancillary services are provided by large conventional generators; however, with the growing interest in distributed generation to satisfy energy and environmental requirements, it seems reasonable to assume that these services could also be provided by distributed generators in an economical and efficient way. In this paper, a proposal for enhancement of the capacity of active power reserve for frequency control using distributed generators is presented. The goal is to minimize the payments done by the transmission system operator to conventional and distributed generators for this ancillary service and for the energy needed to satisfy loads and system losses, subject to a set of constraints. In order to perform analysis, the proposal was implemented using data of the IEEE 30-bus transmission test system. Comparisons were performed considering conventional generators without and with distributed generators installed in the system.
Resumo:
BackgroundAcute pulmonary embolism (PE) is a common cause of death, accounting for 50,000 to 200,000 deaths annually. It is the third most common cause of mortality among the cardiovascular diseases, after coronary artery disease and stroke.The advent of multi-detector computed tomographic pulmonary angiography (CTPA) has allowed better assessment of PE regarding visualisation of the peripheral pulmonary arteries, increasing its rate of diagnosis. More cases of peripheral PEs, such as isolated subsegmental PE (SSPE) and incidental PE, have thereby been identified. These two conditions are usually found in patients with few or none of the classic PE symptoms such as haemoptysis or pleuritic pain, acute dyspnoea or circulatory collapse. However, in patients with reduced cardio-pulmonary (C/P) reserve the classic PE symptoms can be found with isolated SSPEs. Incidental SSPE is found casually in asymptomatic patients, usually by diagnostic imaging performed for other reasons (for example routine CT for cancer staging in oncologic patients).Traditionally, all PEs are anticoagulated in a similar manner independent of the location, number and size of the thrombi. It has been suggested that many patients with SSPE may be treated without benefit, increasing adverse events by possible unnecessary use of anticoagulants.Patients with isolated SSPE or incidental PE may have a more benign clinical presentation compared with those with proximal PEs. However, the clinical significance in patients and their prognosis have to be studied to evaluate whether anticoagulation therapy is required.ObjectivesTo assess the effectiveness and safety of anticoagulation therapy versus no intervention in patients with isolated subsegmental pulmonary embolism (SSPE) or incidental SSPE.Search methodsThe Cochrane Peripheral Vascular Diseases Group Trials Search Co-ordinator searched the Specialised Register (last searched October 2013) and CENTRAL (2013, Issue 9). MEDLINE, EMBASE, LILACS and clinical trials databases were also searched (October 2013).Selection criteriaRandomised controlled trials of anticoagulation therapy versus no intervention in patients with SSPE or incidental SSPE.Data collection and analysisTwo review authors inspected all citations to ensure reliable selection. We planned for two review authors to independently extract data and to assess the methodological quality of identified trials using the criteria recommended in the Cochrane Handbook for Systematic Reviews of Interventions.Main resultsNo studies were identified that met the inclusion criteria.Authors' conclusionsThere is no randomised controlled trial evidence for the effectiveness and safety of anticoagulation therapy versus no intervention in patients with isolated subsegmental pulmonary embolism (SSPE) or incidental SSPE, and therefore we can not draw any conclusions. Well-conducted research is required before informed practice decisions can be made.
Resumo:
It has become evident that policies aimed at mitigating the growing water resources and water use conflicts in Brazil are crucial. The municipality of Extrema in Minas Gerais state in Brazil pioneered the first Brazilian municipal PES initiative (Conservador das Aguas program), based on the relationship between forests and the benefits they provide. This study aimed to assess soil loss in the Posses sub-basin, where the Conservador das Aguas program began. Additionally, we aimed to determine the potential that this PES initiative has for soil conservation, as well as to minimize the soil losses as a function of forest area size and location in order to propose a technical approach for implementing PES. In this sense, considering the prescribed conservation practices, land use situation, and soil cover in the Posses sub-basin, we analyzed the effectiveness of the Conservador das Aguas program before and after implementation in relation to reduced soil loss under 36 different land use and soil cover scenarios. We used a geographic information system (GIS) for spatializing and producing different information plans and the Revised Universal Soil Loss Equation (RUSLE) for estimating soil loss. As a result, we found that minimization of soil loss may be obtained by adopting pasture conservation practices. Additionally the expected average soil loss in the Posses sub-basin under conditions of land use and soil cover, before and after implementing the water conservation program was 30.63 and 7.06 Mg ha(-1) year(-1), respectively. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
In this paper, the optimal reactive power planning problem under risk is presented. The classical mixed-integer nonlinear model for reactive power planning is expanded into two stage stochastic model considering risk. This new model considers uncertainty on the demand load. The risk is quantified by a factor introduced into the objective function and is identified as the variance of the random variables. Finally numerical results illustrate the performance of the proposed model, that is applied to IEEE 30-bus test system to determine optimal amount and location for reactive power expansion.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Engenharia Civil e Ambiental - FEB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The present literature review aimed to describe biodisel’s physicochemical properties obtained from different raw materials. Were studied data concerning viscosity, density, cetane number, fl ash point, pour point and calorifi c power of biodiesel produced from soybean oil, coconut, rice bran, cotton, pequi, babassu, mamona, palm, castor, sunfl ower, corn, canola, jatropha and karanja. Considering the diversity of vegetal and animal sources that can be used on the biodiesel production, it is noteworthy the lack of data concerning physicochemical properties of unexplored raw materials. This work may contribute for the creation of database about physicochemical properties of oil and biodiesel from different sources which will allow design and scale-up, both the necessary equipment to the production line and reciprocating engines.
Resumo:
Indiscriminate and inappropriate use of pesticides in agriculture has been pointed out for increasing health problems and environmental damage. Considering that water resources are the principal destiny of those compounds after application, the present study presents optimization and validation of two simple and effi cient analytical methods for pesticides quantifi cation in both surface and groundwater. Were selected the pesticides more commonly used at Dourados (MS - Brazil), region with intense agricultural activity. Pesticides were preconcentrated by solid-phase extraction using C18 (500 mg) cartridges and then divided in two groups for elution and quantifi cation: 2.4-D and 2.4-DCP were eluted with methanol and quantifi ed by high performance liquid chromatography with ultra-violet detector (HPLC-UV) while atrazine, DIA, DEA, trifl uralin and methyl parathion were eluted with ethylacetate (1:1, v/v) and quantifi ed by gas chromatography with thermionic specifi c detector (GC-TSD). The methods showed satisfactory accuracy (76-107%) and precision (<12%) for the substances analyzed at the fortifi ed levels selected for the study, except for DIA (<51%). Study of pesticide stability also presented good results: C18 cartridges could be stored for at least for 21 days at -20ºC with no signs of the compounds degradability. Both methods limits of quantifi cation of the pesticides (0.22 - 0.48 μg L-1) are in accordance to the levels currently established by the Brazilian national legislation for pesticides in water. Although only the pesticide 2.4-D has been detected in two distinct collection points in the study period of time, this work warns for the requirement of systematical analysis of pesticides presence in water destined to human consume, principally in areas of intense agriculture activity. Such monitoring can provide subsidies for public environmental policies.
Resumo:
Pós-graduação em Biotecnologia Animal - FMVZ
Resumo:
Finney claims that we did not include transaction costs while assessing the economic costs of a set-aside program in Brazil and that accounting for them could potentially render large payments for environmental services (PES) projects unfeasible. We agree with the need for a better understanding of transaction costs but provide evidence that they do not alter the feasibility of the set-aside scheme we proposed.
Resumo:
A new mixed-integer linear programming (MILP) model is proposed to represent the plug-in electric vehicles (PEVs) charging coordination problem in electrical distribution systems. The proposed model defines the optimal charging schedule for each division of the considered period of time that minimizes the total energy costs. Moreover, priority charging criteria is taken into account. The steady-state operation of the electrical distribution system, as well as the PEV batteries charging is mathematically represented; furthermore, constraints related to limits of voltage, current and power generation are included. The proposed mathematical model was applied in an electrical distribution system used in the specialized literature and the results show that the model can be used in the solution of the PEVs charging problem.
Resumo:
This paper presents a mixed-integer convex-optimization-based approach for optimum investment reactive power sources in transmission systems. Unlike some convex-optimization techniques for the reactive power planning solution, in the proposed approach the taps settings of under-load tap-changing of transformers are modeled as a mixed-integer linear set equations. Are also considered the continuous and discrete variables for the existing and new capacitive and reactive power sources. The problem is solved for three significant demand scenarios (low demand, average demand and peak demand). Numerical results are presented for the CIGRE-32 electric power system.