962 resultados para PCR Arrays


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ectrodactyly-ectodermal dysplasiaclefting syndrome is a rare autosomal dominant disorder caused by heterozygous mutations in the p63 gene, a transcription factor belonging to the p53 family. The majority of cases of ectrodactyly-ectodermal dysplasia syndrome are caused by de novo mutations and are therefore sporadic in approximately 60% of patients. The substitution of arginine to histidine (R279H), due to a c.836G>A mutation in exon 7 of the p63 gene, represents 55% of the identified mutations and is considered a mutational hot spot. A quantitative and sensitive real-time PCR was performed to quantify both wild-type and R279H alleles in DNA extracted from peripheral blood and RNA from cultured epithelial cells. Standard curves were constructed for both wild-type and mutant probes. The sensitivity of the assay was determined by generating serial dilutions of the DNA isolated from heterozygous patients (50% of alleles mutated) with wild-type DNA, thus obtaining decreasing percentages of p63 R279H mutant allele (50%, 37.5%, 25%, 12.5%, 10%, 7.5%, 5%, 2.5%, and 0.0%). The assay detected up to 1% of the mutant p63. The high sensitivity of the assay is of particular relevance to prenatal diagnosis and counseling and to detect therapeutic effects of drug treatment or gene therapy aimed at reducing the amount of mutated p63. © 2012 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chemists are now able to emulate the ideas and instruments of mathematics and computer science with molecules. The integration of molecular logic gates into small arrays has been a growth area during the last few years. The design principles underlying a collection of these cases are examined. Some of these computing molecules are applicable in medical- and biotechnologies. Cases of blood diagnostics, 'lab-on-a-molecule' systems, and molecular computational identification of small objects are included.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

False-positive PCR results usually occur as a consequence of specimen-to-specimen or amplicon-to-specimen contamination within the laboratory. Evidence of contamination at time of specimen collection linked to influenza vaccine administration in the same location as influenza sampling is described. Clinical, circumstantial and laboratory evidence was gathered for each of five cases of influenza-like illness (ILI) with unusual patterns of PCR reactivity for seasonal H1N1, H3N2, H1N1 (2009) and influenza B viruses. Two 2010 trivalent influenza vaccines and environmental swabs of a hospital influenza vaccination room were also tested for influenza RNA. Sequencing of influenza A matrix (M) gene amplicons from the five cases and vaccines was undertaken. Four 2009 general practitioner (GP) specimens were seasonal H1N1, H3N2 and influenza B PCR positive. One 2010 GP specimen was H1N1 (2009), H3N2 and influenza B positive. PCR of 2010 trivalent vaccines showed high loads of detectable influenza A and B RNA. Sequencing of the five specimens and vaccines showed greatest homology with the M gene sequence of Influenza A/Puerto Rico/8/1934 H1N1 virus (used in generation of influenza vaccine strains). Environmental swabs had detectable influenza A and B RNA. RNA detection studies demonstrated vaccine RNA still detectable for at least 66 days. Administration of influenza vaccines and clinical sampling in the same room resulted in the contamination with vaccine strains of surveillance swabs collected from patients with ILI. Vaccine contamination should therefore be considered, particularly where multiple influenza virus RNA PCR positive signals (e.g. H1N1, H3N2 and influenza B) are detected in the same specimen.